HomeMy WebLinkAboutA701 1ST FL FINISHOFFICE
108
MEN'S RR
109 OFFICE
111 STOR.
112
OFFICE
113BREAK
110
OFFICE
107
VEST.
101
LOBBY
102
CONFERENCE
104
RECEPTION
103
OFFICE
114
OFFICE
115
WOMEN'S RR
134
WOMEN'S RR
105
WOMEN'S
RESTROOM
124
PFT-1
PWT-1/P-1
PTB-1
BREAK
ROOM
121
SC-1
P-1
VB-1
MEN'S
RESTROOM
123
PFT-1
PWT-1/P-1
PTB-1
VEST
120
CPT-2
P-1
VB-1 P-2STAIR
ST-1
CIRCULATION
214
OPEN
OFFICE/WORKROOM
122
CONC
P-1
VB-1
JAN.
125
CONC
P-1
VB-1
PWT-1
PWT-1
PWT-1
PWT-1
1
ROOM NAME
ROOM #
FLOOR BASE
WALLS
A. ALL GENERAL FINISHES ARE NOTED ON FINISH ROOM TAG U.N.O.
B. REFERENCE REFLECTED CEILING PLAN FOR ADDITIONAL CEILING INFO.
C. ALL NEW INTERIOR FINISHES, INCLUDING FLOOR, WALL, AND CEILING MATERIALS,
SHALL BE IN ACCORDANCE WITH FLAME SPREAD AND SMOKE DEVELOPMENT
REQUIREMENTS FOUND IN THE CURRENT EDITION OF THE INTERNATIONAL BUILDING
CODE.
D. CONTRACTOR TO SUBMIT A MINIMUM OF (3) THREE SAMPLES OF EACH FINISH TO
DESIGNER FOR APPROVAL PRIOR TO ORDERING. ALTERNATES WILL NOT BE
ACCEPTED WITHOUT WRITTEN APPROVAL OF ARCHITECT.
E. CONTRACTOR TO IMMEDIATELY NOTIFY ARCHITECT IF A SPECIFIED FINISH ITEM
BECOMES UNAVAILABLE.
F. THE CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT ALL NEW INTERIOR WALL
AND CEILING FINISHES WILL BE CLASS B MINIMUM, WITH A FLAME SPREAD RATING OF
75 MAXIMUM AND A SMOKE DEVELOPED INDEX OF 450 MAXIMUM PER IBC SECTION 803
G. PREPARE ALL FLOOR AND WALL CONSTRUCTION, NEW AND/OR EXISTING, TO RECEIVE
NEW FINISHES IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDED
INSTALLATION METHODS AND MATERIALS FOR ALL FINISHES.
H. PRIOR TO INSTALLATION OF NEW FINISHES, CONTRACTOR SHALL INSPECT ALL
SUBSTRATES. IF A SUBSTRATE IS DEEMED UNACCEPTABLE, THE CONTRACTOR SHALL
TAKE THE NECESSARY STEPS TO RECTIFY THE SITUATION OR CONTACT THE
ARCHITECT WITH THE CONCERN. PROCEEDING WITH THE INSTALLATION OF FINISHES
WILL BE INDICATION THAT THE INSTALLER / FINISHER ACCEPTS CONDITION OF
SUBSTRATE.
I. USE MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR
ALL FINISHES.
J. ALL NECESSARY TILE FLOORING UNDERLAYMENT TO BE PROVIDED AND INSTALLED BY
FLOORING CONTRACTOR
K. FLOORING CONTRACTOR TO LEVEL SUBSTRATE AS REQUIRED TO ACCEPT NEW
FLOORING MATERIAL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION.
FOR CARPET REQUIRING SEAMING, PROVIDE SEAM DIAGRAM LAYOUT FOR DESIGNER
APPROVAL PRIOR TO INSTALLATION.
L. CARPET SEAMS TO BE LOCATED AT CENTERLINE OF DOOR WHEN DOOR IS IN CLOSED
POSITION
M. ALL FLOORING TRANSITIONS SHALL COMPLY WITH ADA GUIDELINES. FLOORING
CONTRACTOR TO SUBMIT A DIAGRAM SHOWING FLOORING TRANSITION LOCATIONS
FOR DESIGNERS APPROVAL PRIOR TO INSTALLATION.
N. ALL TRANSITION/REDUCER STRIPS AND OTHER THRESHOLDS TO BE LOCATED AT
CENTERLINE OF DOOR WHEN IN CLOSED POSITION
O. ALIGN FLOORING TRANSITIONS WITH FINISH BASE EXCEPT AT DOORS, U.N.O.
P. FINISH LEVEL OF GYP. BD. WALLS AND SOFFITS TO BE LEVEL 4, U.N.O.
Q. ALL PAINTED SURFACES SHALL RECEIVE A MINIMUM OF (1) ONE BASE COAT AND (2)
TWO FINISH COATS
R. PAINTED SHEEN LEVEL TO BE SATIN/EGG-SHELL FOR ALL WALLS, U.N.O. SHEEN FOR
ALL WET AREA WALLS, METAL DOORS AND METAL FRAMES TO BE SEMI-GLOSS.
S. ALL METAL DOORS, STAIR RAILINGS, STRINGERS AND FRAMES TO BE PAINTED P-3.
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:5/21/2021 8:30:44 AMA701
FIRST FLOOR FINISH
PLAN
2021.00173
05/20/2021
CONSTRUCTION DOCUMENTS
ARTISTIC COMPOSITE
PALLETS -PHASE 2
4518 WEST 99TH
STREET CARMEL, IN
46032
N
3/32" = 1'-0"A701
1 FIRST FLOOR FINISH PLAN
FINISH ROOM TAG KEY
GENERAL FINISH NOTES
FINISH KEY PLAN
KEY
NUMBER KEYNOTE DESCRIPTION
1 PAINT NEW CMU WALL. MATCH EXISTING.
REVISION SCHEDULE
NO. DESCRIPTION DATE
06/08/21