Loading...
HomeMy WebLinkAboutElectrical Roof PlanCHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x22020/OCT/20 ISSUED FOR PERMITTING 118/FEB/21 ISSUED FOR PERMITTING 02/14/2017 04:16 PM 20/OCT/20 DESIGNER 1R IN-512459-E10 J.P. MORGAN CHASE 10495 N MICHIGAN RD, CARMEL, IN 46032-7939 ELECTRICAL ROOF PLAN ROOF DESIGN CLEARANCE TABLE (SEE LEGEND FOR APPLICABLE HATCH) ITEM MINIMUM CLEARANCE DIMENSIONS FLAT ROOF 4'-0" PITCHED ROOF: ALONG RIDGE 6'-0" (3'-0" MINIMUM EACH SIDE) PITCHED ROOF: ALONG HIPS/VALLEY 3'-0" (18" MINIMUM EACH SIDE) PITCHED ROOF: ALONG EAVE/FREE EDGE 0'-10" PITCHED ROOF: OTHER CLEARANCE ON ROOF PLANE 3'-0" 01 ELECTRICAL ROOF PLAN NOT TO SCALE SBJ SBJ APN APN SBJ SBJ JDL JASON D. LEIMBACK 11100106 INDIANA JDL 20/OCT/20 LEGEND: FLAT ROOF CLEARANCE AREA PITCHED ROOF CLEARANCE AREA (E) EXISTING NOTES: 1. CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS AND ROOF SLOPES AND COORDINATE WITH ALL REFERENCE DRAWINGS AS REQUIRED. IF THE CONTRACTOR ENCOUNTERS CONDITIONS OTHER THAN WHAT IS SHOWN ON THE DRAWINGS, CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD PRIOR TO START OF CONSTRUCTION. 2. SEE SHEET SG20 AND SG21 FOR GENERAL NOTES, LEGEND AND SYMBOLS. 3. SEE SHEETS SE10 AND SE11 FOR ELECTRICAL DETAILS. 4. FOR THREE PHASE SYSTEMS, MODULES OF SIMILAR ORIENTATION SHALL BE PAIRED WITH ONE OPTIMIZER WHERE POSSIBLE. 5. OBSTRUCTIONS IN CLEARANCE AREA PATHWAYS SHALL BE KEPT TO A MINIMUM. WHERE CONDUIT INTERSECTS CLEARANCE AREA PATHWAYS, CONDUIT SHALL BE PLACED TRANSVERSE TO CLEARANCE AREA PATHWAYS. 6. GROUNDING TRANSFORMER SHALL BE GROUND MOUNTED PER DETAILS ON SS30. 7. SUBCONTRACTOR SHALL MAINTAIN MINIMUM 3' RADIAL CLEARANCE FROM GAS RISER METER.INV1 PNL1 GTR1 PNL 2 T 1-1 1-1 1-2 1-2 M UDS (N) INVERTER ARRAY 1 - 10.875 kW [x29] (N) MODULES TILT: 26.5 DEGREES ROOF PITCH: 6:12 AZIMUTH: 162 DEGREES SOUTHEAST (N) GROUNDING TRANSFORMER NOTE 6 (N) PV EFFECTIVE GROUNDING AC PANEL (N) METERING AND SURGE PROTECTION CABINET (N) TRANSFORMER ARRAY 2 - 7.50 kW [x20] (N) MODULES TILT: 26.5 DEGREES ROOF PITCH: 6:12 AZIMUTH: 72 DEGREES NORTHEAST (E) ELECTRICAL ROOM WITH ELECTRICAL SERVICE PANEL (N) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH (E) COMBINATION CT ENCLOSURE AND UTILITY METER ARRAY 3 - 3.75 kW [x10] (N) MODULES TILT: 25 DEGREES ROOF PITCH: 5.6:12 AZIMUTH: 162 DEGREES SOUTHEAST ARRAY 4 - 4.50 kW [x12] (N) MODULES TILT: 25.74 DEGREES ROOF PITCH: 5.8:12 AZIMUTH: 162 DEGREES SOUTHEAST S W2 (N) INVERTER DISCONNECT SWITCH G (E) GAS RISER METER NOTE 7 (N) NEMA 3R LOCKABLE WIREWAY SBJ APNSBJ JDL JDL 03 ELECTRICAL EQUIPMENT ELEVATION VIEW NOT TO SCALE (N) INVERTER (N) INVERTER DISCONNECT SWITCH (N) GROUNDING TRANSFORMER NOTE 6 (N) PV EFFECTIVE GROUNDING AC PANEL (N) METERING AND SURGE PROTECTION CABINET (N) TRANSFORMER (N) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH 02 ELECTRICAL EQUIPMENT ELEVATION VIEW NOT TO SCALE 18-FEB-2021 06/08/21