HomeMy WebLinkAboutOne Line DiagramINV1 (N) INVERTER LEGEND (N) - NEW EQUIPMENT (E) - EXISTING EQUIPMENT 02 01 PHOTOVOLTAIC STRINGS PM OPT 20 12 9 # REFER TO E30 FOR PLACARD LABELING 7 5 NOTES: 1. THIS CABLE SIZE AND INSTALLATION ALSO APPLIES TO THE CABLE INTERCONNECTING MODULES IN THE SAME STRING WHERE IT IS NOT PROTECTED UNDERNEATH THE PV ARRAY. THE CONDUIT SIZE IS CALCULATED BASED ON THE MAXIMUM SET OF STRINGS ROUTED TO A SINGLE INVERTER. 2. AC SURGE PROTECTOR (SP1) AND OWNER REVENUE GRADE METER (RGM) SHOWN ON THE THREE LINE DIAGRAM ARE INSTALLED IN PNL2. REFER TO SE20D FOR TYPICAL WIRING DIAGRAM DETAILS. 3. SUBCONTRACTOR SHALL PURCHASE AND INSTALL LOCKABLE NEMA 3R WIREWAY BELOW METER BASE AND INTERCONNECT USING POLARIS CONNECTORS OR ENGINEER APPROVED EQUIVALENT. 4. REFER TO ELECTRICAL DETAILS DRAWING SE10 FOR THE COMMUNICATION DETAIL. 5. NEW PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH TO BE LOCATED CLOSE TO EXISTING METER PER UTILITY REQUIREMENTS. 6. SUBCONTRACTOR SHALL USE LOCKS PROVIDED BY DISTRIBUTOR TO LOCK THE PV EFFECTIVE GROUNDING AC PANEL PANEL AND METERING AND SURGE PROTECTION CABINET INVERTER FUSED DISCONNECT SWITCH, PV SYSTEM UTILITY DISCONNECT SWITCH, AND NEMA 3R LOCKABLE WIREWAY. 7. SUBCONTRACTOR SHALL INSTALL A SEPARATELY DERIVED GROUND ON 480/277V SIDE OF THE TRANSFORMER AND ENSURE THAT THE NEUTRAL IS GROUNDED ON ONLY ONE SIDE OF THE TRANSFORMER. 8. REFER TO SE20D FOR WIRING DIAGRAM DETAILS. (N) ( KVA) 480/277V - 208/120V TRANSFORMER TR1 30 05 (N) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH SW1 F1 RGM (N) OWNER REVENUE GRADE METER 06 78 6 117 11 F1-R 2 04 CB1 (N) AC SURGE PROTECTOR SP1 (N) PV EFFECTIVE GROUNDING AC PANEL PNL1 22 CB2 6 3 CB-SP2 07 CB3 (N) GROUNDING TRANSFORMER GTR1 (E) MAIN (E) ELECTRICAL SERVICE PANEL 208/120V, 3 PHASE MAIN BUS: 225A MAIN BREAKER: 225A TO UTILITY GRID15 4 3 13 (E) LOADS 03 SW2 F2 2 6 21 (N) INVERTER DISCONNECT GROUND FAULT RELAY N AUX CONTACT/RELAY POWER PNL2 THERMOSTAT AND HEATER 15A CB4 20A CB530A 15A150A 150A CB-RGM 30A (E) CT RATED BI-DIRECTIONAL UTILITY METER (E) COMBINATION CT ENCLOSURE15 23 23 (10 FEET OR LESS) (N) NEMA 3R LOCKABLE WIREWAY 24 CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 20/OCT/20 ISSUED FOR PERMITTING 118/FEB/21 ISSUED FOR PERMITTING 02/14/2017 04:16 PM 20/OCT/20 DESIGNER 1R IN-512459-E21 J.P. MORGAN CHASE 10495 N MICHIGAN RD, CARMEL, IN 46032-7939 ONE LINE DIAGRAM 01 ONE LINE DIAGRAM NOT TO SCALE SBJ SBJ APN APN SBJ SBJ JDL JASON D. LEIMBACK 11100106 INDIANA JDL 20/OCT/20 SYSTEM INFORMATION DC WIRING LOSSES AT STC STRING INPUTS MODULES IN SERIES DC POWER (STC) TOTAL DC POWER (STC) INVERTER AC POWER ILR INVERTER OUTPUT CURRENT ESTIMATED CIRCUIT LENGTH % VOLTAGE DROP % STC LOSS INVERTER-1 STRING 1-1 37 13,875 W 26,625 W 20,000 W 1.33 24.0A 327 1.00% 1.00% STRING 1-2 34 12,750 W 292 0.82% 0.82% STRING 1-3 NA NA NA NA NA WEIGHTED AVERAGE 0.91% 0.91% DESIGN PARAMETERS ASHRAE EXTREME LOW -23.8 °C ASHRAE 2% HIGH 32.4 °C SERVICE VOLTAGE 208V, 3Ф UTILITY IPL ELECTRICAL CODE NEC 2008 SYSTEM SUMMARY TOTAL DC POWER 26,625 W TOTAL AC POWER 20,000 W WEIGHTED ILR 1.33 INVERTER OUTPUT RATED VOLTAGE 480 V MAX AC CURRENT (480 V) 24.0A TRANSFORMATION VOLTAGE 208 V MAX AC CURRENT (208 V) 55.4A MODULE MAKE MISSION SOLAR MODEL MSE375SQ9S POWER OUTPUT 375 W SHORT CIRCUIT Isc 9.83 A OPEN CIRCUIT VOLTAGE Voc 48.16 V RATED CURRENT Imp 9.43 A RATED VOLTAGE Vmp 39.76 V TEMPERATURE COEFFICIENT OF Voc -0.28%/C TEMPERATURE COEFFICIENT OF Isc 0.046%/C INVERTER MAKE SOLAREDGE MODEL SE20KUS MAXIMUM AC POWER OUTPUT 20,000 W AC RATED VOLTAGE 480Y/277 V MAX CONTINUOUS OUTPUT CURRENT 24.0 A RATED INPUT VOLTAGE 840 V MAXIMUM INPUT CURRENT 26.5 A MAXIMUM SHORT CIRCUIT CURRENT 45.0 A MAXIMUM INPUT VOLTAGE 980 V TRANSFORMER-LESS, UNGROUNDED YES OPTIMIZER MAKE SOLAR EDGE MODEL P850 RATED INPUT DC POWER 850 W MAXIMUM SYSTEM VOLTAGE 1000 V MAXIMUM OUTPUT CURRENT 18.0 A MAXIMUM OUTPUT VOLTAGE 85 V MAXIMUM INPUT VOLTAGE 120 V MAXIMUM SHORT CIRCUIT CURRENT 12.5 A MINIMUM MODULES IN SERIES 27 MAXIMUM MODULES IN SERIES 40 DISTRIBUTOR BILL OF MATERIAL REF CATEGORY MAKE MODEL QTY UNIT DESCRIPTION PM MODULE MISSION SOLAR MSE375SQ9S 71 EA 375WP, 72 CELL SOLAR MODULE (PROVIDED BY JPMC) OPT DC OPTIMIZER SOLAREDGE P850 36 EA SOLAREDGE POWER OPTIMIZER INV1 20KW INVERTER SOLAREDGE SE20KUS 1 EA UTILITY INTERACTIVE DC-TO-AC INVERTER: 3-PHASE, 4-WIRE, 480/277VAC, NEMA 3R, NEC 2014 and 2017 RAPID SHUTDOWN COMPLIANT CELL1 CELLULAR CDMA KIT SOLAREDGE SE-CELL-B-R05-S-S4 1 EA CDMA MODEM W/SIM, INV≤33.3KVA, 5YRS, HB 15MIN PNL2 METERING AND SURGE PROTECTION CABINET VARIES DETAIL 01 1 EA REFER TO DRAWING SE20D FOR CABINET DESIGN AND BOM TR1 TRANSFORMER HPS 226426 1 EA TRANSFORMER 30kVA, 480/277 WYE-GND/208VAC DELTA, NEMA 3R SW1 PV SYSTEM DISCONNECT EATON DG324NRK 1 EA 240VAC, 200A, 3 POLE GENERAL-DUTY,FUSIBLE, SINGLE-THROW DISCONNECT SWITCH, NEMA 3R F1 PV SYSTEM DISCONNECT FUSE BUSSMANN FRN-R-70 3 EA FUSE, 70A, 250VAC, SCCR 200 kA PNL1 PV EFFECTIVE GROUNDING AC PANEL EATON DETAIL 01-Q 1 EA REFER TO DRAWING SE23 FOR PANEL DESIGN AND BOM F1-R FUSE REDUCER BUSSMANN 2621-R 3 EA 250V CLASS R FUSE REDUCER 65 TO 100A FOR 200A DISCONNECT GTR1 GROUNDING TRANSFORMER HPS TBD 1 EA ZIG-ZAG GROUNDING TRANSFORMER, 30A CONTINUOUS NEUTRAL, NEMA 3R, 150:5 NEUTRAL CURRENT TRANSFORMER SW2 INVERTER DISCONNECT EATON DH361NRK 1 EA 600VAC, 30A, HEAVY-DUTY,FUSIBLE, SINGLE-THROW DISCONNECT F2 INVERTER DISCONNECT FUSE BUSSMANN FRS-R-30 3 EA FUSE, 30A, 600VAC, SCCR, 200kA CONDITIONS OF USE CONDUCTOR EGC CONDUIT CIRCUIT INFORMATION CIRCUIT ID DESCRIPTION NUMBER OF TYPICAL CIRCUITS INSULATION TEMP. RATING RACEWAY LOCATION MODIFIED AMBIENT TEMPERATURE # CURRENT CARRYING CONDUCTORS CONDUIT FILL DERATE FACTOR TEMPERATURE DERATE FACTOR MINIMUM SPECIFICATION MINIMUM SPECIFICATION MIN SIZE # OF CONDUCTORS # OF EGC CONDUIT FILL % CONDUCTOR AMPACITY CONDUCTOR DERATED AMPACITY CONT. CURRENT MAXIMUM CURRENT OCPD ESTIMATED CIRCUIT LENGTH % VOLTAGE DROP % AVERAGE LOSSES 01 STRING TO INVERTER (NOTE 1) 2 90 °C > 0.5" & < 3.5" 54 °C 2 0.8 0.76 8 AWG, COPPER, PV WIRE 10 AWG, COPPER, RHW-2 1", EMT 4 1 39% 55 A 33 A 18.0A 22.5A 25 310 FT 0.91% 0.91% 02 20KW INVERTER TO INVERTER DS 1 90 °C UNDER ROOF 32 °C 3 1 0.96 10 AWG, COPPER, THWN-2 10 AWG, COPPER, THWN-2 0.75", EMT 4 1 20% 40 A 38 A 24.0A 30.0A 30 10 FT 0.10% 0.10% 03 INVERTER DS TO TRANSFORMER 1 90 °C UNDER ROOF 32 °C 3 1 0.96 10 AWG, COPPER, THWN-2 8 AWG, COPPER, THWN-2 0.75", EMT 4 1 23% 40 A 38 A 24.0A 30.0A 30 10 FT 0.10% 0.10% 04 TRANSFORMER TO PV EFFECTIVE GND PNL 1 90 °C UNDER ROOF 32 °C 3 1 0.96 1/0 AWG, COPPER, THWN-2 6 AWG, COPPER, THWN-2 1.5", EMT 3 1 30% 170 A 163 A 55.4A 69.2A 150 10 FT 0.06% 0.06% 05 PV EFFECTIVE GND PNL TO UTILITY DS 1 90 °C UNDER ROOF 32 °C 3 1 0.96 4 AWG, COPPER, THWN-2 8 AWG, COPPER, THWN-2 1.25", EMT 4 1 24% 95 A 91 A 55.4A 69.2A 70 20 FT 0.29% 0.29% 06 UTILITY DS TO POI 1 90 °C UNDER ROOF 32 °C 3 1 0.96 4 AWG, COPPER, THWN-2 NA 1.25", RMC 4 0 22% 95 A 91 A 55.4A 69.2A 70 10 FT 0.14% 0.14% 07 EFFECTIVE GND PNL TO GND XFMR 1 90 °C UNDER ROOF 32 °C 3 1 0.96 10 AWG, COPPER, THWN-2 10 AWG, COPPER, THWN-2 0.75" EMT 4 1 20% 40 A 38 A 0 A 10 A 15 10 FT 0.00``% 0.00% TOTAL 1.68% 1.68% SBJ APNSBJ JDL JDL 18-FEB-2021 06/08/21