Loading...
HomeMy WebLinkAbout400130-IN-512459-REV02CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 20/OCT/20 ISSUED FOR PERMITTING 1 18/FEB/21 ISSUED FOR PERMITTING 2 13/MAY/21 ISSUED FOR PERMITTING - REVISED PER AHJ COMMENTS 02/14/2017 04:16 PM 20/OCT/20 DESIGNER 2R J.P. MORGAN CHASE 10495 N MICHIGAN RD, CARMEL, IN 46032-7939 COVER PAGE 512459: 26.63 kWp J.P. MORGAN CHASE 10495 N Michigan Rd CARMEL, IN 46032-7939 ASSESSOR'S #: 29-13-07-019-002.000-018 AUTHORITIES HAVING JURISDICTION BUILDING: CITY OF CARMEL ZONING: CITY OF CARMEL UTILITY: INDIANAPOLIS POWER & LIGHT (IPL) DESIGN SPECIFICATIONS OCCUPANCY: B CONSTRUCTION: COMMERCIAL / INDUSTRIAL GROUND SNOW LOAD: 20 PSF WIND SPEED: 106 MPH DESIGN SPECIFICATIONS RISK CATEGORY: II SITE CLASS: D (DEFAULT) SEISMIC IMPORTANCE FACTOR: 1.0 SEISMIC DESIGN CATEGORY: B SS: 0.173 S1: 0.082 SDS: 0.184 SD1: 0.131 ANALYSIS PROCEDURE: NONSTRUCTURAL COMPONENTS DESIGN CODES & STANDARDS BUILDING: 2018 INTERNATIONAL BUILDING CODE (SEE NOTE 1) ELECTRICAL: 2008 NEC FIRE: 2018 INTERNATIONAL FIRE CODE (SEE NOTE 2) PROJECT INFORMATION IN-512459-G10 KKT KKT TDG TDG SBJ SBJ DRAWING INDEX DRAWING NUMBER SHEET TITLE G10 COVER PAGE G20 SITE PLAN E10 ELECTRICAL ROOF PLAN E20 THREE LINE DIAGRAM & BILL OF MATERIALS E21 ONE LINE DIAGRAM E30 PLACARDS REQUIRED STANDARD DRAWING INDEX DRAWING NUMBER SHEET TITLE SG10 COVER PAGE SG20 GENERAL NOTES SG21 GENERAL NOTES SS20 PITCHED ROOF CONNECTION DETAILS SS21 PITCHED ROOF CONNECTION DETAILS SE10 ELECTRICAL DETAILS SE11 ELECTRICAL DETAILS NEC 2008 SE20 METERING AND SURGE PROTECTION DETAILS 3-PHASE SE21 AC PANEL DETAILS SR10 THREE PHASE SYSTEM CUTSHEETS SR25 ELECTRICAL DATA CUTSHEETS SR26 ELECTRICAL DATA CUTSHEETS SR30 STRUCTURAL COMPONENT CUTSHEETS 01 AERIAL PHOTO NOT TO SCALE 02 VICINITY MAP NOT TO SCALE INDIANA CLB CAMERON L. BRYANT 10505919CLB20/OCT/20 NOTE 1 : INTERNATIONAL BUILDING CODE 2018 REFERENCES THE MOST CURRENT DESIGN PRACTICES RELATED TO STRUCTURAL ANALYSIS AND DESIGN OF ROOFTOP SOLAR MODULE SYSTEMS. ANALYSIS AND DESIGN OF ROOFTOP SOLAR MODULE SYSTEMS WAS PERFORMED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE 2018 AND MEETS 2014 INDIANA BUILDING CODE REQUIREMENTS. NOTE 2 : INTERNATIONAL FIRE CODE 2018 REFERENCES THE MOST CURRENT DESIGN PRACTICES RELATED TO DESIGN OF ROOFTOP SOLAR MODULE SYSTEMS. ANALYSIS AND DESIGN OF ROOFTOP SOLAR MODULE SYSTEMS WAS PERFORMED IN ACCORDANCE WITH INTERNATIONAL FIRE CODE 2018 AND MEETS 2014 INDIANA FIRE CODE REQUIREMENTS. KKT TDG SBJ CLB CLB SS30 TRANSFORMER FOUNDATION KKT TDG SBJ CLB CLB 13-May-2021 06/08/21 SW2 T PNL2 GTR1 PNL1 INV1 CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 20/OCT/20 ISSUED FOR PERMITTING 1 18/FEB/21 ISSUED FOR PERMITTING 2 13/MAY/21 ISSUED FOR PERMITTING - REVISED PER AHJ COMMENTS 02/14/2017 04:16 PM 20/OCT/20 DESIGNER 2R IN-512459-G20 J.P. MORGAN CHASE 10495 N MICHIGAN RD, CARMEL, IN 46032-7939 SITE PLAN ROOF DESIGN CLEARANCE TABLE (SEE LEGEND FOR APPLICABLE HATCH) ITEM MINIMUM CLEARANCE DIMENSIONS FLAT ROOF 4'-0" PITCHED ROOF: ALONG RIDGE 6'-0" (3'-0" MINIMUM EACH SIDE) PITCHED ROOF: ALONG HIPS/VALLEY 3'-0" (18" MINIMUM EACH SIDE) PITCHED ROOF: ALONG EAVE/FREE EDGE 0'-10" PITCHED ROOF: OTHER CLEARANCE ON ROOF PLANE 3'-0" ROOF CONNECTION DETAIL TABLE DRAWING DETAIL ROOF SLOPE FRAMING TYPE ROOF TYPE CONNECTION LOCATION NOTES SS10 1 FLAT ROOF DECK VARIES SEE SITE PLAN SEE RACKING SITE SPECIFIC DRAWING PACKAGE IF APPLICABLE. SS10 2 FLAT ROOF DECK LOOSE GRAVEL SS21 1 PITCHED WOOD MEMBERS ASPHALT SHINGLE SEE DRAWING SS20 SS21 2 PITCHED ROOF DECK SINGLE-PLY MEMBRANE SEE DRAWING SS20 SS21 3 PITCHED NA METAL STANDING SEAM SEE DRAWING SS20 SS21 4 PITCHED WOOD MEMBERS CORRUGATED METAL SEE DRAWING SS20 SS21 5 PITCHED STEEL MEMBERS ASPHALT SHINGLE SEE DRAWING SS20 SS22 1 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20 SS22 2 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20 SS22 3 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20 SS22 4 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20 SS22 5 PITCHED WOOD MEMBERS TILE SEE DRAWING SS20 NOTES: 1. ROOFS WITH SLOPE LESS THAN 7 DEGREES ARE CONSIDERED "FLAT". ROOFS WITH SLOPE GREATER THAN 7 DEGREES ARE CONSIDERED "PITCHED". REFER TO SITE SPECIFIC DWG E10 FOR ROOF SLOPE. 2. FRAMING TYPE AND ROOF TYPE SHALL BE VERIFIED ON SITE PRIOR TO INSTALLATION. 01 SITE PLAN NOT TO SCALE PARCEL DATA FROM LANDGRID.COM KKT KKT TDG TDG SBJ SBJ INDIANA CLB CAMERON L. BRYANT 10505919CLB20/OCT/20 LEGEND: FLAT ROOF CLEARANCE AREA PITCHED ROOF CLEARANCE AREA (E) EXISTING (E) PROPERTY LINE NEW TREE NOTES: 1. CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS AND ROOF SLOPES AND COORDINATE WITH ALL REFERENCE DRAWINGS AS REQUIRED. IF THE CONTRACTOR ENCOUNTERS CONDITIONS OTHER THAN WHAT IS SHOWN ON THE DRAWINGS, CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD PRIOR TO START OF CONSTRUCTION. 2. SEE SHEET SG20 AND SG21 FOR GENERAL NOTES, LEGEND AND SYMBOLS. 4. OBSTRUCTIONS IN CLEARANCE AREA PATHWAYS SHALL BE KEPT TO A MINIMUM. 5. SOLAR ASSEMBLY DOES NOT INCREASE EXISTING BUILDING HEIGHT FOR PITCHED ROOFS. FOR FLAT ROOFS, SOLAR ASSEMBLY EXTENDS 11 3/8" MAXIMUM ABOVE ROOF SURFACE WITH UNIRAC RMDT RACKING AND EXTENDS 1'-1 7/8" MAXIMUM ABOVE ROOF SURFACE WITH IRONRIDGE BX RACKING. 3. EVEREST RACKING RAIL MAXIMUM ALLOWABLE SPAN SHALL BE 4'-0" UNLESS NOTED OTHERWISE. ROOF MEMBRANE: ASPHALT SHINGLES ROOF DECK: PLYWOOD CONNECTION DETAIL: SS21-1 RACKING TYPE: EVEREST CROSSRAIL SHARED – 48-X MAXIMUM CONNECTION SPACING: 4'-0" KKT TDG SBJ CLB CLB 32'-6" NOTES: 1. THE PROVISIONS OF THE INTERNATIONAL FIRE CODE 2018, SEC. 1204.2.1 PERTAINING TO GROUP R-3 BUILDINGS (ONE OR TWO FAMILY DWELLINGS) SPECIFIES SETBACKS AND PATHWAYS FOR PITCHED ROOFS. EXCEPTION TO SEC. 1204.3 STATES THAT IF THE FIRE CODE OFFICIAL DETERMINES THAT THE ROOF CONFIGURATION FOR A BUILDING OTHER THAN GROUP R-3 IS SIMILAR TO THAT OF A GROUP R-3 OCCUPANCY, THE RESIDENTIAL ACCESS REQUIREMENTS IN SEC. 1204.2.1 ARE A SUITABLE ALTERNATIVE. THEREFORE, CONSIDERING FIREFIGHTING OPERATIONS, BUILDINGS WITH A PITCHED ROOF HAVE BEEN CONSIDERED SIMILAR TO THAT OF A GROUP R-3 BUILDING AND THE PROVISIONS OF SEC. 1204.2.1 WERE USED. KKT TDG SBJ CLB CLB 13-May-2021 06/08/21 SW2 T PNL 2 GT R1 PN L1 INV 1 CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 20/OCT/20 ISSUED FOR PERMITTING 1 18/FEB/21 ISSUED FOR PERMITTING 2 13/MAY/21 ISSUED FOR PERMITTING - REVISED PER AHJ COMMENTS 02/14/2017 04:16 PM 20/OCT/20 DESIGNER 2R IN-512459-E10 J.P. MORGAN CHASE 10495 N MICHIGAN RD, CARMEL, IN 46032-7939 ELECTRICAL ROOF PLAN ROOF DESIGN CLEARANCE TABLE (SEE LEGEND FOR APPLICABLE HATCH) ITEM MINIMUM CLEARANCE DIMENSIONS FLAT ROOF 4'-0" PITCHED ROOF: ALONG RIDGE 6'-0" (3'-0" MINIMUM EACH SIDE) PITCHED ROOF: ALONG HIPS/VALLEY 3'-0" (18" MINIMUM EACH SIDE) PITCHED ROOF: ALONG EAVE/FREE EDGE 0'-10" PITCHED ROOF: OTHER CLEARANCE ON ROOF PLANE 3'-0" 01 ELECTRICAL ROOF PLAN NOT TO SCALE SBJ SBJ APN APN SBJ SBJ JDL JASON D. LEIMBACK 11100106 INDIANA JDL 20/OCT/20 LEGEND: FLAT ROOF CLEARANCE AREA PITCHED ROOF CLEARANCE AREA (E) EXISTING NOTES: 1. CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS AND ROOF SLOPES AND COORDINATE WITH ALL REFERENCE DRAWINGS AS REQUIRED. IF THE CONTRACTOR ENCOUNTERS CONDITIONS OTHER THAN WHAT IS SHOWN ON THE DRAWINGS, CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD PRIOR TO START OF CONSTRUCTION. 2. SEE SHEET SG20 AND SG21 FOR GENERAL NOTES, LEGEND AND SYMBOLS. 3. SEE SHEETS SE10 AND SE11 FOR ELECTRICAL DETAILS. 4. FOR THREE PHASE SYSTEMS, MODULES OF SIMILAR ORIENTATION SHALL BE PAIRED WITH ONE OPTIMIZER WHERE POSSIBLE. 5. OBSTRUCTIONS IN CLEARANCE AREA PATHWAYS SHALL BE KEPT TO A MINIMUM. WHERE CONDUIT INTERSECTS CLEARANCE AREA PATHWAYS, CONDUIT SHALL BE PLACED TRANSVERSE TO CLEARANCE AREA PATHWAYS. 6. GROUNDING TRANSFORMER SHALL BE GROUND MOUNTED PER DETAILS ON SS30. 7. SUBCONTRACTOR SHALL MAINTAIN MINIMUM 3' RADIAL CLEARANCE FROM GAS RISER METER. 8. SUBCONTRACTOR SHALL PAINT CONDUIT, IF VISIBLE FROM GRADE, TO MATCH THE BUILDING SURFACE IT IS ATTACHED TO (EAVE PORTION SHOULD BE PAINTED TO MATCH EAVE; BRICK PORTION SHOULD BE PAINTED TO MATCH BRICK). SUBCONTRACTOR SHALL PAINT TRANSFORMER ENCLOSURE, INVERTER DISCONNECT SWITCH ENCLOSURE, GROUNDING TRANSFORMER ENCLOSURE, PV EFFECTIVE GROUNDING AC PANEL ENCLOSURE, METERING AND SURGE PROTECTION CABINET, IF VISIBLE FROM GRADE, TO MATCH THE BUILDING SURFACE IT IS ATTACHED TO. SUBCONTRACTOR SHALL ENSURE THAT EQUIPMENT NAMEPLATES AND LABELS ARE NOT PAINTED. THE INVERTER SHALL REMAIN UNPAINTED. 9. SEE G10 FOR LANDSCAPING DETAILS. 1-1 1-1 1-2 1-2 M UDS (N) INVERTER NOTE 8 ARRAY 1 - 10.875 kW [x29] (N) MODULES TILT: 26.5 DEGREES ROOF PITCH: 6:12 AZIMUTH: 162 DEGREES SOUTHEAST (N) GROUNDING TRANSFORMER NOTE 6 (N) PV EFFECTIVE GROUNDING AC PANEL NOTE 8 (N) METERING AND SURGE PROTECTION CABINET NOTE 8 (N) TRANSFORMER NOTE 8 ARRAY 2 - 7.50 kW [x20] (N) MODULES TILT: 26.5 DEGREES ROOF PITCH: 6:12 AZIMUTH: 72 DEGREES NORTHEAST (E) ELECTRICAL ROOM WITH ELECTRICAL SERVICE PANEL (N) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH (E) COMBINATION CT ENCLOSURE AND UTILITY METER ARRAY 3 - 3.75 kW [x10] (N) MODULES TILT: 25 DEGREES ROOF PITCH: 5.6:12 AZIMUTH: 162 DEGREES SOUTHEAST ARRAY 4 - 4.50 kW [x12] (N) MODULES TILT: 25.74 DEGREES ROOF PITCH: 5.8:12 AZIMUTH: 162 DEGREES SOUTHEAST (N) INVERTER DISCONNECT SWITCH NOTE 8 G (E) GAS RISER METER NOTE 7 (N) NEMA 3R LOCKABLE WIREWAY SBJ APN SBJ JDL JDL 03 ELECTRICAL EQUIPMENT ELEVATION VIEW NOT TO SCALE (N) INVERTER (N) INVERTER DISCONNECT SWITCH (N) GROUNDING TRANSFORMER NOTE 6 (N) PV EFFECTIVE GROUNDING AC PANEL (N) METERING AND SURGE PROTECTION CABINET (N) TRANSFORMER (N) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH SBJ APN SBJ JDL JDL 02 ELECTRICAL EQUIPMENT ELEVATION VIEW NOT TO SCALE NOTE 9 13-MAY-2021 06/08/21 L1L2L3G G N (N) MODULESPM IN STRING IN STRING OPT (N) DC OPTIMIZERS INV1 (N) INVERTER 01 01 37 34 LEGEND (N) -NEW EQUIPMENT (E) -EXISTING EQUIPMENT NOTES: 1. THIS CABLE SIZE AND INSTALLATION ALSO APPLIES TO THE CABLE INTERCONNECTING MODULES IN THE SAME STRING WHERE IT IS NOT PROTECTED UNDERNEATH THE PV ARRAY. THE CONDUIT SIZE IS CALCULATED BASED ON THE MAXIMUM SET OF STRINGS ROUTED TO A SINGLE INVERTER. 2. AC SURGE PROTECTOR (SP1) AND OWNER REVENUE GRADE METER (RGM) SHOWN ON THE THREE LINE DIAGRAM ARE INSTALLED IN PNL2. REFER TO SE20D FOR TYPICAL WIRING DIAGRAM DETAILS. 3. SUBCONTRACTOR SHALL PURCHASE AND INSTALL LOCKABLE NEMA 3R WIREWAY BELOW METER BASE AND INTERCONNECT USING POLARIS CONNECTORS OR ENGINEER APPROVED EQUIVALENT. 4. REFER TO ELECTRICAL DETAILS DRAWING SE10 FOR THE COMMUNICATION DETAIL. 5. NEW PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH TO BE LOCATED CLOSE TO EXISTING METER PER UTILITY REQUIREMENTS. 6. SUBCONTRACTOR SHALL USE LOCKS PROVIDED BY DISTRIBUTOR TO LOCK THE PV EFFECTIVE GROUNDING AC PANEL PANEL AND METERING AND SURGE PROTECTION CABINET INVERTER FUSED DISCONNECT SWITCH, PV SYSTEM UTILITY DISCONNECT SWITCH, AND NEMA 3R LOCKABLE WIREWAY. 7. SUBCONTRACTOR SHALL INSTALL A SEPARATELY DERIVED GROUND ON 480/277V SIDE OF THE TRANSFORMER AND ENSURE THAT THE NEUTRAL IS GROUNDED ON ONLY ONE SIDE OF THE TRANSFORMER. 8. REFER TO SE20D FOR WIRING DIAGRAM DETAILS. 02 G (N) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH NOTE 5 & 7 SW1 F1 RGM (N) OWNER REVENUE GRADE METER NOTES 2, 4 & 6 (10 FEET OR LESS) OUTSIDE INSIDE 06 F1-R CB-SP G N (E) LOADS (E) ELECTRICAL SERVICE PANEL 208/120V, 3 PHASE MAIN BUS: 225A MAIN BREAKER: 225A (E) GROUNDING ELECTRODE L1 L2L3 L2 TO UTILITY GRID (E) MAIN AWG GEC TIED TO BLDG/SITE GROUNDING ELECTRODE SYSTEM 6 S/NG L1N L2 L3 05 PNL1 CB1 CB2 (N) PV EFFECTIVE GROUNDING AC PANEL NOTE 6 (N) AC SURGE PROTECTOR NOTE 2 SP1 N CB3 07 (N) GROUNDING TRANSFORMER GTR1 04 G (N) INVERTER FUSED DISCONNECT SWITCH SW2 F2 CB-RGM 03N NOTE 8 GROUND FAULT RELAY 15A 30A CB4 15A NOTE 8 AUX CONTACT/RELAY POWER CB520A PNL2 THERMOSTAT AND HEATER NOTE 8 30A 150A 150A NOTE 2 (E) CT RATED BI-DIRECTIONAL UTILITY METER (E) COMBINATION CT ENCLOSURE (N) ( KVA) 480/277V - 208/120V TRANSFORMER TR1 30 AWG GEC TIED TO NEW GROUND ROD NOTE 7 6 N NOTE 3 CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 20/OCT/20 ISSUED FOR PERMITTING 1 18/FEB/21 ISSUED FOR PERMITTING 2 13/MAY/21 ISSUED FOR PERMITTING - REVISED PER AHJ COMMENTS 02/14/2017 04:16 PM 20/OCT/20 DESIGNER 2R IN-512459-E20 J.P. MORGAN CHASE 10495 N MICHIGAN RD, CARMEL, IN 46032-7939 THREE LINE DIAGRAM AND BILL OF MATERIALS CONDITIONS OF USE CONDUCTOR EGC CONDUIT CIRCUIT INFORMATION CIRCUIT ID DESCRIPTION NUMBER OF TYPICAL CIRCUITS INSULATION TEMP. RATING RACEWAY LOCATION MODIFIED AMBIENT TEMPERATURE # CURRENT CARRYING CONDUCTORS CONDUIT FILL DERATE FACTOR TEMPERATURE DERATE FACTOR MINIMUM SPECIFICATION MINIMUM SPECIFICATION MIN SIZE # OF CONDUCTORS # OF EGC CONDUIT FILL % CONDUCTOR AMPACITY CONDUCTOR DERATED AMPACITY CONT. CURRENT MAXIMUM CURRENT OCPD ESTIMATED CIRCUIT LENGTH % VOLTAGE DROP % AVERAGE LOSSES 01 STRING TO INVERTER (NOTE 1) 2 90 °C > 0.5" & < 3.5" 54 °C 2 0.8 0.76 8 AWG, COPPER, PV WIRE 10 AWG, COPPER, RHW-2 1", EMT 4 1 39% 55 A 33 A 18.0A 22.5A 25 310 FT 0.91% 0.91% 02 20KW INVERTER TO INVERTER DS 1 90 °C UNDER ROOF 32 °C 3 1 0.96 10 AWG, COPPER, THWN-2 10 AWG, COPPER, THWN-2 0.75", EMT 4 1 20% 40 A 38 A 24.0A 30.0A 30 10 FT 0.10% 0.10% 03 INVERTER DS TO TRANSFORMER 1 90 °C UNDER ROOF 32 °C 3 1 0.96 10 AWG, COPPER, THWN-2 8 AWG, COPPER, THWN-2 0.75", EMT 4 1 23% 40 A 38 A 24.0A 30.0A 30 10 FT 0.10% 0.10% 04 TRANSFORMER TO PV EFFECTIVE GND PNL 1 90 °C UNDER ROOF 32 °C 3 1 0.96 1/0 AWG, COPPER, THWN-2 6 AWG, COPPER, THWN-2 1.5", EMT 3 1 30% 170 A 163 A 55.4A 69.2A 150 10 FT 0.06% 0.06% 05 PV EFFECTIVE GND PNL TO UTILITY DS 1 90 °C UNDER ROOF 32 °C 3 1 0.96 4 AWG, COPPER, THWN-2 8 AWG, COPPER, THWN-2 1.25", EMT 4 1 24% 95 A 91 A 55.4A 69.2A 70 20 FT 0.29% 0.29% 06 UTILITY DS TO POI 1 90 °C UNDER ROOF 32 °C 3 1 0.96 4 AWG, COPPER, THWN-2 NA 1.25", RMC 4 0 22% 95 A 91 A 55.4A 69.2A 70 10 FT 0.14% 0.14% 07 EFFECTIVE GND PNL TO GND XFMR 1 90 °C UNDER ROOF 32 °C 3 1 0.96 10 AWG, COPPER, THWN-2 10 AWG, COPPER, THWN-2 0.75" EMT 4 1 20% 40 A 38 A 0 A 10 A 15 10 FT 0.00``% 0.00% TOTAL 1.68% 1.68% SYSTEM INFORMATION DC WIRING LOSSES AT STC STRING INPUTS MODULES IN SERIES DC POWER (STC) TOTAL DC POWER (STC) INVERTER AC POWER ILR INVERTER OUTPUT CURRENT ESTIMATED CIRCUIT LENGTH % VOLTAGE DROP % STC LOSS INVERTER-1 STRING 1-1 37 13,875 W 26,625 W 20,000 W 1.33 24.0A 327 1.00% 1.00% STRING 1-2 34 12,750 W 292 0.82% 0.82% STRING 1-3 NA NA NA NA NA WEIGHTED AVERAGE 0.91% 0.91% DESIGN PARAMETERS ASHRAE EXTREME LOW -23.8 °C ASHRAE 2% HIGH 32.4 °C SERVICE VOLTAGE 208V, 3Ф UTILITY IPL ELECTRICAL CODE NEC 2008 SYSTEM SUMMARY TOTAL DC POWER 26,625 W TOTAL AC POWER 20,000 W WEIGHTED ILR 1.33 INVERTER OUTPUT RATED VOLTAGE 480 V MAX AC CURRENT (480 V) 24.0A TRANSFORMATION VOLTAGE 208 V MAX AC CURRENT (208 V) 55.4A 01 THREE LINE DIAGRAM NOT TO SCALE SBJ SBJ APN APN SBJ SBJ JDL JASON D. LEIMBACK 11100106 INDIANA JDL 20/OCT/20 MODULE MAKE MISSION SOLAR MODEL MSE375SQ9S POWER OUTPUT 375 W SHORT CIRCUIT Isc 9.83 A OPEN CIRCUIT VOLTAGE Voc 48.16 V RATED CURRENT Imp 9.43 A RATED VOLTAGE Vmp 39.76 V TEMPERATURE COEFFICIENT OF Voc -0.28%/C TEMPERATURE COEFFICIENT OF Isc 0.046%/C DISTRIBUTOR BILL OF MATERIAL REF CATEGORY MAKE MODEL QTY UNIT DESCRIPTION PM MODULE MISSION SOLAR MSE375SQ9S 71 EA 375WP, 72 CELL SOLAR MODULE (PROVIDED BY JPMC) OPT DC OPTIMIZER SOLAREDGE P850 36 EA SOLAREDGE POWER OPTIMIZER INV1 20KW INVERTER SOLAREDGE SE20KUS 1 EA UTILITY INTERACTIVE DC-TO-AC INVERTER: 3-PHASE, 4-WIRE, 480/277VAC, NEMA 3R, NEC 2014 and 2017 RAPID SHUTDOWN COMPLIANT CELL1 CELLULAR CDMA KIT SOLAREDGE SE-CELL-B-R05-S-S4 1 EA CDMA MODEM W/SIM, INV≤33.3KVA, 5YRS, HB 15MIN PNL2 METERING AND SURGE PROTECTION CABINET VARIES DETAIL 01 1 EA REFER TO DRAWING SE20D FOR CABINET DESIGN AND BOM TR1 TRANSFORMER HPS 226426 1 EA TRANSFORMER 30kVA, 480/277 WYE-GND/208VAC DELTA, NEMA 3R SW1 PV SYSTEM DISCONNECT EATON DG324NRK 1 EA 240VAC, 200A, 3 POLE GENERAL-DUTY,FUSIBLE, SINGLE-THROW DISCONNECT SWITCH, NEMA 3R F1 PV SYSTEM DISCONNECT FUSE BUSSMANN FRN-R-70 3 EA FUSE, 70A, 250VAC, SCCR 200 kA PNL1 PV EFFECTIVE GROUNDING AC PANEL EATON DETAIL 01-Q 1 EA REFER TO DRAWING SE23 FOR PANEL DESIGN AND BOM F1-R FUSE REDUCER BUSSMANN 2621-R 3 EA 250V CLASS R FUSE REDUCER 65 TO 100A FOR 200A DISCONNECT GTR1 GROUNDING TRANSFORMER HPS TBD 1 EA ZIG-ZAG GROUNDING TRANSFORMER, 30A CONTINUOUS NEUTRAL, NEMA 3R, 150:5 NEUTRAL CURRENT TRANSFORMER SW2 INVERTER DISCONNECT EATON DH361NRK 1 EA 600VAC, 30A, HEAVY-DUTY,FUSIBLE, SINGLE-THROW DISCONNECT F2 INVERTER DISCONNECT FUSE BUSSMANN FRS-R-30 3 EA FUSE, 30A, 600VAC, SCCR, 200kA INVERTER MAKE SOLAREDGE MODEL SE20KUS MAXIMUM AC POWER OUTPUT 20,000 W AC RATED VOLTAGE 480Y/277 V MAX CONTINUOUS OUTPUT CURRENT 24.0 A RATED INPUT VOLTAGE 840 V MAXIMUM INPUT CURRENT 26.5 A MAXIMUM SHORT CIRCUIT CURRENT 45.0 A MAXIMUM INPUT VOLTAGE 980 V TRANSFORMER-LESS, UNGROUNDED YES OPTIMIZER MAKE SOLAR EDGE MODEL P850 RATED INPUT DC POWER 850 W MAXIMUM SYSTEM VOLTAGE 1000 V MAXIMUM OUTPUT CURRENT 18.0 A MAXIMUM OUTPUT VOLTAGE 85 V MAXIMUM INPUT VOLTAGE 120 V MAXIMUM SHORT CIRCUIT CURRENT 12.5 A MINIMUM MODULES IN SERIES 27 MAXIMUM MODULES IN SERIES 40 (N) NEMA 3R LOCKABLE WIREWAY SBJ APN SBJ JDL JDL SBJ APN SBJ JDL JDL 13-MAY-2021 06/08/21 INV1 (N) INVERTER LEGEND (N) - NEW EQUIPMENT (E) - EXISTING EQUIPMENT 02 01 PHOTOVOLTAIC STRINGS PM OPT 20 12 9 # REFER TO E30 FOR PLACARD LABELING 7 5 NOTES: 1. THIS CABLE SIZE AND INSTALLATION ALSO APPLIES TO THE CABLE INTERCONNECTING MODULES IN THE SAME STRING WHERE IT IS NOT PROTECTED UNDERNEATH THE PV ARRAY. THE CONDUIT SIZE IS CALCULATED BASED ON THE MAXIMUM SET OF STRINGS ROUTED TO A SINGLE INVERTER. 2. AC SURGE PROTECTOR (SP1) AND OWNER REVENUE GRADE METER (RGM) SHOWN ON THE THREE LINE DIAGRAM ARE INSTALLED IN PNL2. REFER TO SE20D FOR TYPICAL WIRING DIAGRAM DETAILS. 3. SUBCONTRACTOR SHALL PURCHASE AND INSTALL LOCKABLE NEMA 3R WIREWAY BELOW METER BASE AND INTERCONNECT USING POLARIS CONNECTORS OR ENGINEER APPROVED EQUIVALENT. 4. REFER TO ELECTRICAL DETAILS DRAWING SE10 FOR THE COMMUNICATION DETAIL. 5. NEW PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH TO BE LOCATED CLOSE TO EXISTING METER PER UTILITY REQUIREMENTS. 6. SUBCONTRACTOR SHALL USE LOCKS PROVIDED BY DISTRIBUTOR TO LOCK THE PV EFFECTIVE GROUNDING AC PANEL PANEL AND METERING AND SURGE PROTECTION CABINET INVERTER FUSED DISCONNECT SWITCH, PV SYSTEM UTILITY DISCONNECT SWITCH, AND NEMA 3R LOCKABLE WIREWAY. 7. SUBCONTRACTOR SHALL INSTALL A SEPARATELY DERIVED GROUND ON 480/277V SIDE OF THE TRANSFORMER AND ENSURE THAT THE NEUTRAL IS GROUNDED ON ONLY ONE SIDE OF THE TRANSFORMER. 8. REFER TO SE20D FOR WIRING DIAGRAM DETAILS. (N) ( KVA) 480/277V - 208/120V TRANSFORMER TR1 30 05 (N) PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH SW1 F1 RGM (N) OWNER REVENUE GRADE METER 06 78 6 117 11 F1-R 2 04 CB1 (N) AC SURGE PROTECTOR SP1 (N) PV EFFECTIVE GROUNDING AC PANEL PNL1 22 CB2 6 3 CB-SP2 07 CB3 (N) GROUNDING TRANSFORMER GTR1 (E) MAIN (E) ELECTRICAL SERVICE PANEL 208/120V, 3 PHASE MAIN BUS: 225A MAIN BREAKER: 225A TO UTILITY GRID15 4 3 13 (E) LOADS 03 SW2 F2 2 6 21 (N) INVERTER DISCONNECT GROUND FAULT RELAY N AUX CONTACT/RELAY POWER PNL2 THERMOSTAT AND HEATER 15A CB4 20A CB530A 15A150A 150A CB-RGM 30A (E) CT RATED BI-DIRECTIONAL UTILITY METER (E) COMBINATION CT ENCLOSURE15 23 23 (10 FEET OR LESS) (N) NEMA 3R LOCKABLE WIREWAY 24 CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 20/OCT/20 ISSUED FOR PERMITTING 1 18/FEB/21 ISSUED FOR PERMITTING 2 13/MAY/21 ISSUED FOR PERMITTING - REVISED PER AHJ COMMENTS 02/14/2017 04:16 PM 20/OCT/20 DESIGNER 2R IN-512459-E21 J.P. MORGAN CHASE 10495 N MICHIGAN RD, CARMEL, IN 46032-7939 ONE LINE DIAGRAM 01 ONE LINE DIAGRAM NOT TO SCALE SBJ SBJ APN APN SBJ SBJ JDL JASON D. LEIMBACK 11100106 INDIANA JDL 20/OCT/20 SYSTEM INFORMATION DC WIRING LOSSES AT STC STRING INPUTS MODULES IN SERIES DC POWER (STC) TOTAL DC POWER (STC) INVERTER AC POWER ILR INVERTER OUTPUT CURRENT ESTIMATED CIRCUIT LENGTH % VOLTAGE DROP % STC LOSS INVERTER-1 STRING 1-1 37 13,875 W 26,625 W 20,000 W 1.33 24.0A 327 1.00% 1.00% STRING 1-2 34 12,750 W 292 0.82% 0.82% STRING 1-3 NA NA NA NA NA WEIGHTED AVERAGE 0.91% 0.91% DESIGN PARAMETERS ASHRAE EXTREME LOW -23.8 °C ASHRAE 2% HIGH 32.4 °C SERVICE VOLTAGE 208V, 3Ф UTILITY IPL ELECTRICAL CODE NEC 2008 SYSTEM SUMMARY TOTAL DC POWER 26,625 W TOTAL AC POWER 20,000 W WEIGHTED ILR 1.33 INVERTER OUTPUT RATED VOLTAGE 480 V MAX AC CURRENT (480 V) 24.0A TRANSFORMATION VOLTAGE 208 V MAX AC CURRENT (208 V) 55.4A MODULE MAKE MISSION SOLAR MODEL MSE375SQ9S POWER OUTPUT 375 W SHORT CIRCUIT Isc 9.83 A OPEN CIRCUIT VOLTAGE Voc 48.16 V RATED CURRENT Imp 9.43 A RATED VOLTAGE Vmp 39.76 V TEMPERATURE COEFFICIENT OF Voc -0.28%/C TEMPERATURE COEFFICIENT OF Isc 0.046%/C INVERTER MAKE SOLAREDGE MODEL SE20KUS MAXIMUM AC POWER OUTPUT 20,000 W AC RATED VOLTAGE 480Y/277 V MAX CONTINUOUS OUTPUT CURRENT 24.0 A RATED INPUT VOLTAGE 840 V MAXIMUM INPUT CURRENT 26.5 A MAXIMUM SHORT CIRCUIT CURRENT 45.0 A MAXIMUM INPUT VOLTAGE 980 V TRANSFORMER-LESS, UNGROUNDED YES OPTIMIZER MAKE SOLAR EDGE MODEL P850 RATED INPUT DC POWER 850 W MAXIMUM SYSTEM VOLTAGE 1000 V MAXIMUM OUTPUT CURRENT 18.0 A MAXIMUM OUTPUT VOLTAGE 85 V MAXIMUM INPUT VOLTAGE 120 V MAXIMUM SHORT CIRCUIT CURRENT 12.5 A MINIMUM MODULES IN SERIES 27 MAXIMUM MODULES IN SERIES 40 DISTRIBUTOR BILL OF MATERIAL REF CATEGORY MAKE MODEL QTY UNIT DESCRIPTION PM MODULE MISSION SOLAR MSE375SQ9S 71 EA 375WP, 72 CELL SOLAR MODULE (PROVIDED BY JPMC) OPT DC OPTIMIZER SOLAREDGE P850 36 EA SOLAREDGE POWER OPTIMIZER INV1 20KW INVERTER SOLAREDGE SE20KUS 1 EA UTILITY INTERACTIVE DC-TO-AC INVERTER: 3-PHASE, 4-WIRE, 480/277VAC, NEMA 3R, NEC 2014 and 2017 RAPID SHUTDOWN COMPLIANT CELL1 CELLULAR CDMA KIT SOLAREDGE SE-CELL-B-R05-S-S4 1 EA CDMA MODEM W/SIM, INV≤33.3KVA, 5YRS, HB 15MIN PNL2 METERING AND SURGE PROTECTION CABINET VARIES DETAIL 01 1 EA REFER TO DRAWING SE20D FOR CABINET DESIGN AND BOM TR1 TRANSFORMER HPS 226426 1 EA TRANSFORMER 30kVA, 480/277 WYE-GND/208VAC DELTA, NEMA 3R SW1 PV SYSTEM DISCONNECT EATON DG324NRK 1 EA 240VAC, 200A, 3 POLE GENERAL-DUTY,FUSIBLE, SINGLE-THROW DISCONNECT SWITCH, NEMA 3R F1 PV SYSTEM DISCONNECT FUSE BUSSMANN FRN-R-70 3 EA FUSE, 70A, 250VAC, SCCR 200 kA PNL1 PV EFFECTIVE GROUNDING AC PANEL EATON DETAIL 01-Q 1 EA REFER TO DRAWING SE23 FOR PANEL DESIGN AND BOM F1-R FUSE REDUCER BUSSMANN 2621-R 3 EA 250V CLASS R FUSE REDUCER 65 TO 100A FOR 200A DISCONNECT GTR1 GROUNDING TRANSFORMER HPS TBD 1 EA ZIG-ZAG GROUNDING TRANSFORMER, 30A CONTINUOUS NEUTRAL, NEMA 3R, 150:5 NEUTRAL CURRENT TRANSFORMER SW2 INVERTER DISCONNECT EATON DH361NRK 1 EA 600VAC, 30A, HEAVY-DUTY,FUSIBLE, SINGLE-THROW DISCONNECT F2 INVERTER DISCONNECT FUSE BUSSMANN FRS-R-30 3 EA FUSE, 30A, 600VAC, SCCR, 200kA CONDITIONS OF USE CONDUCTOR EGC CONDUIT CIRCUIT INFORMATION CIRCUIT ID DESCRIPTION NUMBER OF TYPICAL CIRCUITS INSULATION TEMP. RATING RACEWAY LOCATION MODIFIED AMBIENT TEMPERATURE # CURRENT CARRYING CONDUCTORS CONDUIT FILL DERATE FACTOR TEMPERATURE DERATE FACTOR MINIMUM SPECIFICATION MINIMUM SPECIFICATION MIN SIZE # OF CONDUCTORS # OF EGC CONDUIT FILL % CONDUCTOR AMPACITY CONDUCTOR DERATED AMPACITY CONT. CURRENT MAXIMUM CURRENT OCPD ESTIMATED CIRCUIT LENGTH % VOLTAGE DROP % AVERAGE LOSSES 01 STRING TO INVERTER (NOTE 1) 2 90 °C > 0.5" & < 3.5" 54 °C 2 0.8 0.76 8 AWG, COPPER, PV WIRE 10 AWG, COPPER, RHW-2 1", EMT 4 1 39% 55 A 33 A 18.0A 22.5A 25 310 FT 0.91% 0.91% 02 20KW INVERTER TO INVERTER DS 1 90 °C UNDER ROOF 32 °C 3 1 0.96 10 AWG, COPPER, THWN-2 10 AWG, COPPER, THWN-2 0.75", EMT 4 1 20% 40 A 38 A 24.0A 30.0A 30 10 FT 0.10% 0.10% 03 INVERTER DS TO TRANSFORMER 1 90 °C UNDER ROOF 32 °C 3 1 0.96 10 AWG, COPPER, THWN-2 8 AWG, COPPER, THWN-2 0.75", EMT 4 1 23% 40 A 38 A 24.0A 30.0A 30 10 FT 0.10% 0.10% 04 TRANSFORMER TO PV EFFECTIVE GND PNL 1 90 °C UNDER ROOF 32 °C 3 1 0.96 1/0 AWG, COPPER, THWN-2 6 AWG, COPPER, THWN-2 1.5", EMT 3 1 30% 170 A 163 A 55.4A 69.2A 150 10 FT 0.06% 0.06% 05 PV EFFECTIVE GND PNL TO UTILITY DS 1 90 °C UNDER ROOF 32 °C 3 1 0.96 4 AWG, COPPER, THWN-2 8 AWG, COPPER, THWN-2 1.25", EMT 4 1 24% 95 A 91 A 55.4A 69.2A 70 20 FT 0.29% 0.29% 06 UTILITY DS TO POI 1 90 °C UNDER ROOF 32 °C 3 1 0.96 4 AWG, COPPER, THWN-2 NA 1.25", RMC 4 0 22% 95 A 91 A 55.4A 69.2A 70 10 FT 0.14% 0.14% 07 EFFECTIVE GND PNL TO GND XFMR 1 90 °C UNDER ROOF 32 °C 3 1 0.96 10 AWG, COPPER, THWN-2 10 AWG, COPPER, THWN-2 0.75" EMT 4 1 20% 40 A 38 A 0 A 10 A 15 10 FT 0.00``% 0.00% TOTAL 1.68% 1.68% SBJ APN SBJ JDL JDL SBJ APN SBJ JDL JDL 13-MAY-2021 06/08/21 SW2 T PNL2 GTR1 PNL1 INV1 CHECKED DATE DRAWN CODE APPPDE CHK DES NO DATE REVISIONS AND RECORD OF ISSUE DRAWING NUMBERPROJECT REV AREADRN ANSI D 34x220 20/OCT/20 ISSUED FOR PERMITTING 1 18/FEB/21 ISSUED FOR PERMITTING 2 13/MAY/21 ISSUED FOR PERMITTING - REVISED PER AHJ COMMENTS 02/14/2017 04:16 PM 20/OCT/20 DESIGNER 2R J.P. MORGAN CHASE 10495 N MICHIGAN RD, CARMEL, IN 46032-7939 PLACARDS SERVICE DISCONNECTING MEANS PV ARRAY !CAUTION! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: IN-512459-E30 PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH SBJ SBJ APN APN SBJ SBJ JDL JASON D. LEIMBACK 11100106 INDIANA JDL 20/OCT/20 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV SYSTEM DISCONNECTING MEANS [NEC 690.4(D)] AT THE SERVICE ENTRANCE (ELECTRICAL SERVICE PANEL) AND PHOTOVOLTAIC SYSTEM DISCONNECT SWITCH OPERATING DC CURRENT: 36 A OPERATING DC VOLTAGE: 840 V MAX SHORT CURRENT: 45 A MAX VOLTAGE: 980 V AT EACH 20 KW INVERTER DC DISCONNECTING MEANS [NEC 690.53] 20 PHOTOVOLTAIC AC DISCONNECT AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS [NEC 690.54] OPERATING AC CURRENT: 55.4A OPERATING AC VOLTAGE: 208V, 3Ф ! WARNING ! ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. AT EACH JUNCTION, COMBINER, DISCONNECT AND DEVICE WHERE ENERGIZED UNGROUNDED CONDUCTORS MAY BE EXPOSED DURING SERVICE [NEC 690.35(F)] ! WARNING ! ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. ! WARNING ! DUAL POWER SOURCES. SECOND SOURCE IS PV SYSTEM PHOTOVOLTAIC DC DISCONNECT PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH WARNING: PHOTOVOLTAIC POWER SOURCE ! CAUTION ! PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! WARNING ! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE PHOTOVOLTAIC SYSTEM METER INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED AT UTILITY METER [NEC 690.56(B)] PLAQUE INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED SOUTHEAST SIDE OF THE BUILDING ! WARNING ! ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ! WARNING ! TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL AT EACH BREAKER PANEL AND MAIN SERVICE DISCONNECT. [NEC 110.27(C)] ! WARNING ! PHOTOVOLTAIC SYSTEM DATA ACQUISITION SYSTEM AUTHORIZED PERSONNEL ONLY THE PV DAS SHALL BE LABELED WITH THE FOLLOWING INFORMATION AT EACH AC DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL AND DISCONNECT. [NEC 110.16] ! WARNING ! ARC FLASH HAZARD. APPROPRIATE PPE REQUIRED. FAILURE TO COMPLY MAY RESULT IN INJURY OR DEATH. REFER TO NFPA 70 E. AT EACH PHOTOVOLTAIC SYSTEM SERVICE DISCONNECT SWITCH. ! DANGER ! ARC FLASH AND SHOCK HAZARD PRESENT DO NOT OPEN DOOR WHILE ENERGIZED INCIDENT ENERGY EXCEEDS MAX PPE PROTECTION PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PHOTOVOLTAIC SYSTEM SERVICE DISCONNECT SWITCH DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS TO THIS PANEL AT DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL (IF APPLICABLE) NET GENERATION OUTPUT METER AT NET GENERATION OUTPUT METER AT THE ELECTRICAL SERVICE PANEL ! WARNING ! A GENERATION SOURCE IS CONNECTED TO THE SUPPLY (UTILITY) SIDE OF THE SERVICE DISCONNECTING MEANS. FOLLOW PROPER LOCKOUT/TAGOUT PROCEDURES TO ENSURE THE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH IS OPENED PRIOR TO PERFORMING WORK ON THE DEVICE. 1 2 3 5 1716 15 14 13 12 9 10 11 6 7 8 419 18 AT EACH AC DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT [NEC 690.17] AT EACH DC DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT [NEC 690.17] AT PHOTOVOLTAIC SYSTEM SERVICE DISCONNECT SWITCH [NEC 690.14(C)(2)] AT PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH [NEC 690.14(C)(2)] AT EACH DC DISCONNECTING MEANS [NEC 690.14(C)(2)] AT EACH DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER. [NEC 705.12(D)(7)] AT POINT OF INTERCONNECTION; LABEL MUST IDENTIFY PHOTOVOLTAIC SYSTEM [NEC 705.12(D)(4)] AT POINT OF INTERCONNECTION; LABEL MUST IDENTIFY PHOTOVOLTAIC SYSTEM [NEC 705.12(D)(4)] AT PHOTOVOLTAIC SYSTEM DISCONNECT SWITCH [NEC 2014 - 690.56(C)]. LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1]. AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. [NEC 690.31(E)] LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1] LABELING NOTES 1.1 LABELING REQUIREMENTS BASED ON THE 2008 NATIONAL ELECTRICAL CODE. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT FOR WHICH THEY ARE INSTALLED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. DEDICATED PV EFFECTIVE GROUNDING AC PANEL AT PV EFFECTIVE GROUNDING AC PANEL 22 PHOTOVOLTAIC SYSTEM INVERTER DISCONNECT SWITCH AT INVERTER DISCONNECT 21 23 24 SBJ APN SBJ JDL JDL SBJ APN SBJ JDL JDL 13-MAY-2021 06/08/21