HomeMy WebLinkAboutC010.14_SU2.1.UDSEE STRUCTURE DATA TABLE FORCASTING TYPE AND ELEVATIONFINISH GRADEASPHALTICMASTIC OR BUTYLRUBBER SEALBETWEEN JOINTSPRECAST CONCRETE ADJUSTINGRINGS AS NEEDED (12" OF RINGS MAX.)ECCENTRIC CONE OR REDUCERCAP AS REQUIRED BY SITECONDITIONS. CONE TOP TOMATCH ADJUSTING RING PROFILE.48" DIA.5"16"
TYP.PRECAST CONCRETESECTIONSPREFORMED HOLE TO MAX.OF PIPE O.D. + 6" W/ NONSHRINK CEMENT GROUTBENCHWALLS AT MIN. 1/2" PERFOOT SLOPE. BENCHWALLS TOBE CONSTRUCTED TO SPRINGLINE OF PIPE.MANHOLE BASE SET ON6" OF #8 OR #2 STONECOMPACTEDSUBGRADEPLASTIC ENCAPSULATEDSTEEL MANHOLE STEPSO-RING GASKETASPHALTIC MASTICOR BUTYL RUBBERSEAL AT JOINTSBASE 6" OR 8"PER SECTION3"#4 BAR @ 12" o.c.EACH WAY(STEEL MESHAREA = 0.12 SQ.IN./SQ. FT.)STORM MANHOLE TYPE "C" DETAIL1/2" = 1'-0"24" DIA.SEE STRUCTURE DATATABLE FOR PIPE SIZEAND INVERT ELEV.NOTES:1.MANHOLE CONFORMS TO ASTM C478, JOINTS CONFORM TO ASTM C443.2.ALL STORM SEWER CASTINGS SHALL BE MARKED "DUMP NO WASTEDRAINS TO WATERWAYS".3.SEE UTILITY PLAN FOR STORM SEWER STRUCTURE DATA TABLE.VARIES
16" MIN.12" TO 15""A"PIPE SIZE24" X 24"STRUCTURE SIZING CHART"F"30" X 30""M"24" X 36"1" = 1'-0"STORM INLET DETAILINSIDEDIMENSIONSINLETTYPE8"6"CLASS "A" PRECAST REINFORCEDCONCRETE BOXSEE STRUCTURE DATATABLE FOR PIPE SIZEAND INVERT ELEV.INSIDE DIMENSION* SEE SIZING CHART ABOVESEE STRUCTURE DATA TABLE FORCASTING TYPE AND ELEVATIONBASE SET ON 6" OF#8 OR #2 STONECOMPACTEDSUBGRADEINSIDE DIMENSION
* SEE SIZING CHART ABOVE
MAX. NUMBER OFSIDES OF THEINLET WITH PIPES318" TO 24"315" TO 18"3NOTES:1.ALL STORM SEWER CASTINGS SHALL BE MARKED "DUMP NO WASTEDRAINS TO WATERWAYS".2.SEE UTILITY PLAN FOR STORM SEWER STRUCTURE DATA TABLE.FOR PIPE LOCATED IN ANDWITHIN 5' OF PAVED AREASFOR PIPE LOCATEDIN GRASSED AREASSTORM SEWER (PVC & HDPE) TRENCH DETAILNO SCALENOTES:1.ALL BEDDING & INITIAL BACKFILLSHALL BE INSTALLED IN 6" TO 12"BALANCED LIFTS.2.A MIN. 9" CLEARANCE EACH SIDEOR PIPE FOR 42" DIA. AND LESS.BcMIN.
4"
12"MIN. 1.25 O.D.+12"MIN. 6" TOPSOILOUTSIDE PAVEMENT LIMITSPAVEMENT SECTIONREGULAR BACKFILL -GREATER THAN 5' FROMEDGE OF PAVEMENTCOMPACTED 90%REGULAR BACKFILL-GREATER THAN 5' FROMEDGE OF PAVEMENTCOMPACTED TO 90%#8 CRUSHED STONE OREQUIVALENT CLASS 1MATERIAL HAND TAMPEDOR WALKED INTO PLACE"B" BORROW (INDOT SPEC.) OREQUIVALENT GRANULARMATERIAL COMPACTED TO 95%STANDARD PROCTER DENSITY20 L.F. (MIN,)20 L.F. (MIN,)20 L.F. (MIN,)20 L.F. (MIN,)20 L.F. (MIN,)20 L.F. (MIN,)20 L.F. (MIN,)20 L.F. (MIN,)2'-0"VARIES4" DIA. PERF.PVC SDR-35 PIPE1'-0"4"NON WOVENFILTER CLOTH#8 WASHEDAGGREGATECOMPACTED AGGREGATE BASEPAVEMENTCURB INLETNOTES:1.TAP STRUCTURES IN PAVEMENT AS SHOWNOR AS DIRECTED ON THE PLAN SHEET2.ADJUST UNDERDRAIN AS REQUIRED TOAVOID SEWER LINES AND OTHER UTILITIES.3.GROUT SOLID THE CONNECTION TO STORMSTRUCTUREPAVEMENT UNDERDRAIN DETAILNONESTORM SEWER / WATER LINE CROSSING DETAILNONE1/6 Bc3"4"6"LEGEND MATERIAL BELOW PIPEd = DEPTH OF BEDDINGD = INSIDE DIAMETERBc = OUTSIDE DIAMETER30" TO 60"27" & SMALLER66" & LARGER D (d) MIN. 3/4" = 1'-0"DEPTH OF BEDDINGMATERIAL BELOW PIPENOTES:1.ALL BEDDING & INITIAL BACKFILLSHALL BE INSTALLED IN 6" TO 12"BALANCED LIFTS.2.A MIN. 9" CLEARANCE EACH SIDEOR PIPE FOR 42" DIA. AND LESS.REGULAR BACKFILL -GREATER THAN 5' FROM EDGEOF PAVEMENT COMPACTED 90%MIN. 1.25 O.D.+12"FOR PIPE LOCATED IN ANDWITHIN 5' OF PAVED AREASFOR PIPE LOCATEDIN GRASSED AREASBcMIN. 6" TOPSOILIN NON-PAVED AREASPAVEMENT SECTION"B" BORROW (INDOT SPEC.) OREQUIVALENET GRANULARMATERIAL COMPACTED TO 95%STANDARD PROCTER DENSITY"B" BORROW (INDOT SPEC.) OREQUIVALENET GRANULARMATERIAL COMPACTED TO 95%STANDARD PROCTER DENSITYdSTORM SEWER (RCP) TRENCH DETAILSLOPEMIN.NOTE: CLEANOUTS IN PAVED AREAS TO BE ACCESSIBLE VIA YARDBOXES OR EXTENDED FLUSH WITH THE PAVING. CO VER SHOULD BETHREADED TYPE, WATER TIGHT AND CAPPED.1/2" = 1'-0"CLEANOUT DETAILVARIES FINISH GRADESTORM OR SANITARY SEWER(SIZE SHOWN ON PLANS)SAME SIZE AS MAIN LINE(MAX. 8" REQUIRED ON STORM SEWERS)1'-0"1'-0"MIN.6"1/2"HEAVY DUTY CLEANOUTCASTING - JAY R. SMITH 4253SERIES OR EQUALCONCRETE COLLAR(CONCRETE SHALL NOTBE IN CONTACT w/ PIPE)30"72"60"102"108"96"6"7"9"9"SEE SCHEDULEFOR CASTING TYPEAND ELEVATIONFINISHGRADESTORM MANHOLE TYPE "J - N" DETAIL1/2" = 1'-0"24" DIA.PRECAST CONCRETEADJUSTING RING4" MIN. - 12" MAX. SEE DETAILPLASTIC ENCAPSULATEDSTEEL MANHOLE STEPS48" DIA.STANDARD PRECASTMANHOLE CAP OR CONE3" MIN.
6'-0" MIN.9"8"
MIN.
3" MIN.
16"
TYP.5"5"CONCRETE REDUCER CAP1/2" PER FOOT SLOPEBASE SET ON 6" OF#8 OR #2 STONECOMPACTEDSUBGRADEDIA. "F""H""H"1'-0" MIN. OVERHIGHEST PIPEDIA
.
"G
"ONE COMPLETE UNIT OF PRECASTCONC. MANHOLE BASE AND RISER.SEPARATE BASE IS OPTIONALNOTES:MANHOLE CONFORMS TO ASTM C478.JOINTS CONFORM TO ASTM C443.NO BRICK OR BLOCK WILL BEALLOWED IN MANHOLE.MANHOLETYPE"J""K""L""M""N"MANHOLEDIA "F"MAX. PIPE SIZE@ 90° - DIA "G""H" - WALLTHICKNESS36"48"60"72"9"MAX. PIPE SIZEMAINLINE - DIA "G"36"48"54"72"84"SU2.1UTILITY DETAILSCONSULTANTPROJECT NUMBER: 220114.00CARMEL CLAY SCHOOLSPROJECT ISSUE DATE: 12.15.2020DRAWN BY: HHWREV.NO.DESCRIPTIONDATETAC SUBMITTALWWW.FHAI.COMARCHITECT317-848-0966350 E NEW YORK ST# 300, INDIANAPOLIS, IN 46204COPYRIGHT 2020 BY FANNING/HOWEY ASSOCIATES, INC.CARMEL HIGHSCHOOLPERFORMINGARTS ADDITIONANDRENOVATIONS520 E MAIN STREETCARMEL, IN 46032CARMEL TAC REVIEW01/13/2021A19700317No.