HomeMy WebLinkAboutLandscape Pages from Revised Construction Plans 6-16-20 6�Im
Remove any container
NTING DETAI
Aluminum Finial
Refractive Luminaire
Model DI 33 - A028
Dynamic Lighting
Cast Aluminum Pole
Color: Black
NOTE:
For character review only.
Options may include 12'-0" pole height,
dual lamps, banner arms, receptacles,
and street signs.
Remove tags and
PROTOTYPICAL STREET LIGHT FIXTURE
Not To Scale
Capstone —
3" Overhang.
0.5" Minimum Reveal -
Limestone Band
(4" tail by 2.5" thick)
Downiight to be attached to
bottom of cap or column face
under overhang and
directed to illuminate sign.
Engraved Lettering- cut 0.25"
deep and paintediack
- fonts to be chosen by Owner.
Veneer (natural stone, -
or manufactured stone)
- all manufactured stone to
be attached to block with
0.5" Type-S mortar
- grout joints to be
0.375"-0.416" and tooled.
Weep - 2 per side just
above finished grade.
CMU Core
Capstone
CONIFEROUS TREE
i
Remove all wire baskets,
twine and burlap.
Before tree is in the hole,
remove bottom of basket
cutting horizontally.
After tree is in the hole,
remove rest of basket
cutting vertically.
Backfill using existing soil.
Water thoroughly to
eliminate air pockets. —
Add 1-2 inches of
hardwood mulch.
Keep mulch 3 inches
from trunk.
33"
t
l�
1
GROVE ® 101
Limestone Slab Sin 1
(+1- 22"x20" by 2.2T" thick) 1
i
attached with 2" stainless t•"
steel Z Anchors and Tap -Con nto CMU's-
t
t
I
t N
®®� Conduit to be installed •
to accommodate wiring �
for downlighi. f
❑❑® �w
1" t
Limestone Slab Facinj
+!- 13" high by 2.5" thick �.
- 1" chamfer at top.
J I ' I
_1____J
1
I----�i -�L-J
I it I
I J�--
r---- i
I I
I i
Front
33"
Remove tags and
labels.
Prune only dead or
broken branches or
double leaders.
Stake tree
if necessary.
Remove excess soil
to locate and expose
root flare.
Root flare should be
1-2 inches above
finish grade.
Finish grade.
�,gTNBQp�
Limestone Slab Facing
(+1- 18.75" by 2" thick)
rl t
16
# t
1
k t Column Core - 13 standard CMU's high
16 -1.5 standard CMU's square
- horizontal Dura-O-Wall 16" O.C.
}
1...
9'-1" +1
'1�11 I Column Base - 3 standard CMU's high
t__ _ JL_it— _ J - 1.75 to 2 standard CMU's square
_ - - - horizontal Dura-O-Wall 16" O.C.
r--yl lr----1
{ I{ I I
I I
I I
- - - - - - - - - - - - = Bottom of footer 36" below finished grade -
Side
29"
1 --------- - - - -
-I
I l
Concrete Footer- 44"x44"x12" thick
4000 psi with three #4 rebar
reenforcement grid 10" O.C.
centered horzontally in footer 6" from
bottom
no wooden stakes
- must be poured into dry hole on
.�-r l undisturbed soil
- rebar minimum 2 from all surfaces
- Contractor shall submit mix tickets
I_ JJ �J J from concrete supplier to Owner.
I I
I I
Plan Plan
PROTOTYPICAL NEIGHBORHOOD ENTRY MONUMENT
Not To Scale
Remove trunk wrap
If necessary.
Remove all wire baskets,
twine and burlap.
Before tree is in the hole,
remove bottom of basket
cutting horizontally.
After tree is in the hole,
remove rest of basket
cutting vertically.
Backfill using existing soil.
Water thoroughly to
eliminate air pockets. —
Add 1-2 inches of
hardwood mulch.
Keep mulch 3 inches
from trunk.
Remove tags and
labels.
Prune only dead or
broken branches or
double leaders.
Stake tree
if necessary.
Remove excess soil
to locate and expose
root flare.
Root flare should be
1-2 inches above
finish grade.
Finish grade.
60 0 30 60
1 INCH = 60 FEET
al IIIIII�I
w
U_
w
U
2
A�
W
I♦
J
W
I..L
W
O
v�
Q
Z
Q
Z
O
Z
O
J_
V)
=
J_
Q
w
Uli
0
U
W
lti
0-
Q
U
J W
=
0
z
Q
J
a
!Y
_ O
z
W O
Q
a >_
OfJ
0- U
SECTION: I TOWNSHIP: I RANGE
DRAWN BY: DATE:
EWS 03.14.16
SHEET NO.
C91 0
S&AJOB NO.
55115PYT