Loading...
HomeMy WebLinkAboutC200 - Site Development Plan-C200757750755755755751752753754757 753753751 750 748749 751752 753 755757755 756 W WWWWWWWWWWWWWWEX. 10" SDR-26 P.V.C.EX. 12" WATERMAINEX. MH. #705 T.C.=756.32 10" S.D.R. 26 P.V.C N INV.=736.96 10" S.D.R. 26 P.V.C S INV.=736.94 8" S.D.R. 26 P.V.C W INV.=747.46 EX. MH. #706 T.C.=756.82 10" S.D.R. 26 P.V.C S INV.=738.08 EX. MH. #736 T.C.=755.93 8" S.D.R. 35 P.V.C S INV.=750.50 EX. MH. #727 T.C.=755.19 8" S.D.R. 26 P.V.C S INV.=745.62 8" S.D.R. 35 P.V.C E INV.=747.53 8" S.D.R. 35 P.V.C W INV.=745.83 EX. MH. #726 T.C.=758.49 8" S.D.R. 26 P.V.C N INV.=744.62 8" S.D.R. 26 P.V.C S INV.=744.52 8" S.D.R. 26 P.V.C W INV.=746.23 EX. MH. #734 T.C.=757.89 8" S.D.R. 35 P.V.C S INV.=748.92 8" S.D.R. 26 P.V.C E INV.=748.82 8" S.D.R. 35 P.V.C N INV.=749.70 EX. YARD INLET #800 T.C.=755.77 15" R.C.P. N INV.=751.41 18" R.C.P. S INV.=751.31 EX. YARD INLET #799 T.C.=755.68 15" R.C.P. S INV.=752.05 12" R.C.P. N INV.=752.65 EX. END SECTION #800A 12" R.C.P. S INV.=753.15 WWWWWWWW EX. YARD INLET #836 T.C.=756.37 ADJUST TC = 755.40 12" R.C.P. W INV.=752.50EX. END SECTION #830 36" R.C.P. E INV.=749.79 EX. MH. #726 T.C.=756.32 8" S.D.R. 35 P.V.C S INV.=746.22 8" S.D.R. 35 P.V.C E INV.=746.32 EX. MH. #727 T.C.=756.66 8" S.D.R. 35 P.V.C N INV.=747.36 8" S.D.R. 35 P.V.C S INV.=747.14 8" S.D.R. 35 P.V.C W INV.=747.04 > o o o > o o o > o o o > o o o> o o o> o o o > o o o > o o oVAR. D.U.S.S.&756751 752 753 754 PICKETT PLACE SPURR LANE(PRIVATE)(PRIVATE)EX. 8" WATER MAIN EX. FIRE HYDRANT EX. FIRE HYDRANT756.45WWWWWWW W W W W W W W W W W WWWW WWEX. CURB INLET #831 T.C.=756.34 12" R.C.P. E INV.=752.46 EX. MANHOLE #832 T.C.=756.25 12" R.C.P. W INV.=752.05 18" R.C.P. S INV.=751.67 15" R.C.P. E INV.=751.77 EX. YARD INLET #864 T.C.=756.06 15" R.C.P. W INV.=752.11 12" R.C.P. E INV.=752.11 EX. YARD INLET #864A T.C.=756.26 12" R.C.P. E INV.=752.62 12" R.C.P. W INV.=752.52 EX. YARD INLET #835 T.C.=757.09 12" R.C.P. W INV.=753.72 EX. MH. #725 T.C.=757.98 8" S.D.R. 26 P.V.C E INV.=748.98 8" S.D.R. 35 P.V.C W INV.=749.08 EX. MH. #791 T.C.=758.54 8" S.D.R. 35 P.V.C W INV.=750.60 8" S.D.R. 35 P.V.C E INV.=750.50 EX. MH. #790 T.C.=758.69 8" S.D.R. 35 P.V.C E INV.=751.59 EX. MANHOLE #826 T.C.=755.94 27" R.C.P. SW INV.=751.16 18" R.C.P. S INV.=751.25 15" R.C.P. E INV.=751.16 EX. MH. #769 T.C.=756.93 8" S.D.R. 35 P.V.C S INV.=748.45 8" S.D.R. 35 P.V.C N INV.=748.55 EX. MH. #774 T.C.=756.49 8" S.D.R. 35 P.V.C S INV.=748.22 8" S.D.R. 35 P.V.C N INV.=748.32 757 750 749 751752 753 750749 751 752 750 748 749 751 752748 750 748 749 751 752 753 754747750749751752750 748749 751752 EXISTING PATH 12' ASPHALT PATHWWWWWWWWWWWWWWWWWWW W W W W W W W W W W W W W W W W W W W W W W W W W L.C.A. #7 1,869 sq.ft. 10' B.L.10' B.L.10' B.L. 10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L. 10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.10' B.L.VAR. D.U.& L.M.A.E.15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E. 15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E.15' D&U.E.* ** * *** * * * * * * ** * * * **10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.&U.E.10' D.&U.E. 10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.U.&S.S.E.10' D.U.&S.S.E. 10' D.&U.E.10' D.&U.E.10' D.&U.E.10' D.&U.E.10' D.&U.E.10' D.&U.E.10' D.&U.E.10' B.L.VAR. D.U.PA, L.M.A.E. & B.M.P.E. 5' WALK (BY BUILDER)5' WALK (BY BUILDER)5' WALK (BY BUILDER) * G.C.A. #15 77,300 sq.ft. G.C.A. #16 23,700 sq.ft. VAR. D.U.PA, L.M.A.E. & B.M.P.E. > o o o > o o o > o o o > o o o> o o o> o o o > o o o > o o o> o o o> o o o10+50 754.99 0+50 754.91 1+00 755.35 1+50 755.78 2+00 756.22 2+50 756.23 3+00 755.63 3+50 755.02 4+00 754.42 4+50 753.99 5+00 754.27 5+50 754.83 6+00 755.37 6+50 755.36 7+00 755.01 7+50 754.66 9+00 754.07 9+50 753.86 10+00 754.39 0+00756.771+00755.370+50756.076+00756.665+50756.366+89752.843+59756.704+00756.094+50755.345+00754.725+50754.236+00753.736+50753.2311+18754.558+00756.088+50755.489+00754.889+50754.7410+00755.0410+50755.3311+00754.88818317 L.F. 18" R.C.P. @ 0.33%100 L.F. 21" R.C.P. @ 0.44%820 30 L.F. 21" R.C.P. @ 0.47% 821 60 L.F. 21" R.C.P. @ 0.47% 857 13 L.F. 12" R.C.P. @ 0.32%78 L.F. 12" R.C.P. @ 0.72%860 15 L.F. 21" R.C.P. @ 0.27% 866 15 L.F. 15" R.C.P. @ 0.53%5+22.37756.27LP6+15.22756.75GRD.CHG.4+55.66 753.98 LP 6+23.01 755.49 HP 7+77.15 754.56 LP 9+37.32 753.83 LP8+23.00 754.98 GRD.CHG.8+36.37 754.70 GRD.CHG.8+09.62 754.70 GRD.CHG.0+13.38 754.59 GRD.CHG.2+26.32 756.36 HP9+32.35754.69LP10+55.79755.34HP874 873 15 L.F. 12" R.C.P. @ 0.60% 161 L.F. 15" R.C.P. @ 0.61% 875 31 L.F. 12" R.C.P. @ 2.72% 730 729 728 LARSON DRIVE(PUBLIC)LARSON DRIVE(PRIVATE)WILBUR ROAD(PRIVATE)EVERETT DRIVE (PRIVATE) EVERETT DRIVE (PRIVATE) EVERETT DRIVE (PRIVATE) EVERETT DRIVE (PRIVATE)SPURR LANE(PRIVATE)50' I.E.E. 50' I.E.E. V.A.R. R/W BIKE PROMENADE 50' I.E.E.50' I.E.E.50' I.E.E.50' R/W T.C.=755.50 731T.C.=754.80 T.C.=755.10 > o o o10' D.&U.E.V.A.R. R/W BIKE PROMENADE 3940414243 101102103104105106107108 109110111112113114115116117118119120121122123124125126 127 128 129 130 131 162 163164 165 44 45 38 37 817 JAMES DEAN DRIVE(PUBLIC)JAMES DEAN DRIVE(PUBLIC)1.20% -2.08% -1.00%-1.40%2.08% -0.70%1.10%-1.21%0.60%L.C.A. #5A 3,237 sq.ft. VAR. D.U.& L.M.A.E. 50' R/W 757.6755.6756.0755.1756.2755.1756.3756.6 756.6 757.1756.0756.6755.7754.8754.4755.3755.7755.1756.6757.1 755.0755.0755.0755.0755.0755.0755.0755.0755.0755.0755.0755.0754.3754.5755.2756.3 757.1 H.P. 756.3 757.1 757.1757.1756.0755.6 758.3757.9757.9757.9757.9757.9 756.0756.1755.6755.5756.2757.4757.4756.9 755.4 755.9755.3 758.3 757.2757.2756.0756.0755.6 755.0757.0756.7757.5757.4756.9757.4756.0756.9757.4756.2755.5755.4755.6755.9755.6755.6755.4755.3757.0 757.1 755.6756.3 757.5 H.P. 757.3 H.P.754.8755.0757.7757.630' B-B 30' B-B 30' B-B 30' B-B 30' B-B30' B-B30' B-B-1.20%0.60%0.87%-1.49%-1.00%121 L.F. SWALE @ 1.00% 80 L.F. SWALE @ 1.00%80 L.F. SWALE @ 1.00%120 L.F. SWALE @ 1.00%40 L.F. SWALE @ 1.00% 859 25' 858A 857A 31 L.F. 12" R.C.P. @ 0.30% 7.82% EXISTING WESTERN DITCH (BUILT BY OTHERS) BOTTOM ELEV.=747.40 (AT EAST END) TOP OF BANK ELEV.=752.00 10-YEAR ELEV.=749.92 100-YEAR ELEV. (WITH NO WHITE RIVER TAILWATER)=751.87 STORAGE PROVIDED @ 751.87=4.10 ACRE-FEET WHITE RIVER 100-YR=752.00 EXISTING EASTERN DITCH (BUILT BY OTHERS) BOTTOM ELEV.=745.00 (AT EAST END) TOP OF BANK ELEV.=752.00 10-YEAR ELEV.=749.34 100-YEAR ELEV. (WITH NO WHITE RIVER TAILWATER)=751.26 STORAGE PROVIDED @ 751.26=3.40 ACRE-FEET WHITE RIVER 100-YR=752.00 12' ASPHALT PATH*** * 858 819 755 755756757756756756 757 756 75 5 755 755 756 755 754 750 748749 751752 750749 751 752 750 748 749 751 752 753 754 750 747748749 751752 750749 751 752753754750749751752 750 749 751752 753 755755755 754755 7 5 6 757 755 755756 75 6 757 756 757 753757756755756 756 756756 757 25' 756.5756.5 44 L.F. 12" R.C.P. @ 0.95% MLAG 758.1 MLAG 758.1 MLAG 758.1 MLAG 758.1 MLAG 758.1 MLAG 758.5 MLAG 758.5 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 754.0 MLAG 755.1MLAG 755.1MLAG 755.1 MLAG 756.4MLAG 756.4MLAG 755.8 MLAG 757.3MLAG 757.3MLAG 757.3MLAG 757.3MLAG 756.0MLAG 756.0MLAG 757.4MLAG 757.4MLAG 755.3 MLAG 755.3 MLAG 755.3 MLAG 755.8 MLAG 755.8 MLAG 755.3 MLAG 755.3 MLAG 755.3 MLAG 756.0 MLAG 756.0 MFF 756.5 MFF 757.2 MFF 757.6 MFF 757.5 MFF 756.6 MFF 755.8 MFF 756.3 MFF 756.3MFF 756.7 MFF 756.6 MFF 758.6 MFF 758.6 MFF 758.6 MFF 758.6 MFF 758.6 MFF 759.0 MFF 759.0 MFF 755.6 MFF 755.6 MFF 756.6 MFF 757.9MFF 757.9MFF 757.6MFF 757.6MLAG 756.4MLAG 756.4MFF 755.8MFF 757.2MFF 757.2MFF 755.8DATEMARKREVISIONSBYCERTIFIED:S & A JOB NO.THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RETRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY OR A SURVEYOR LOCATIONREPORT.S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942SHEET NO. DRAWN BY:CHECKED BY:SITE DEVELOPMENT PLANSECTION FIVEC200 VEGETATIVE COVER EXISTING SITE CONSIST MOSTLY OF GRASS AND WEEDS ON THE SITE. LAND USE ADJACENT PROPERTIES NORTH: GRASS/WEEDS EAST: RESIDENTIAL SOUTH: RESIDENTIAL WEST: GRASS/WEEDS TO CONVERT THE 1929 BENCHMARK TO NAVD88, SUBTRACT 0.43 FEET FROM ALL ELEVATIONS. NGVD29 - 0.43' = NAVD88" DRAINAGE SUMMARY Site Acreage = 5.103 ac. Offsite/Upstream Acreage= 0 ac. Allowable Release Rate Eastern System: 10yr =29.86 cfs 100yr = 87.18 cfs Post Developed Release Rates: 10yr= 22.0 cfs 100yr= 32.7 cfs This section drains to existing detention basins built with previous sections (Detention Basin CW1 & VS6). These existing basins are part of the overall Eastern Drainage System per the approved Post Construction Storm Water Master Plan (Sept. 2012). Basin CW1 drains to VS6, which outlets to DD6, DD6 also outlets to DD11, DD11 outlets from the site into the White River. Post-Developed Conditions comply with the Allowable Conditions stated in the Legacy Master Drainage Plan. NOTES TO CONTRACTOR 1 ALL PADS SHOULD BE TESTED TO ASSURE A COMPACTION OF AT LEAST 95 PERCENT OF THE MAXIMUM DRY DENSITY USING THE STANDARD PROCTOR TEST METHOD. 2 ANY PRIVATE TILES LOCATED ON THIS SITE WILL NEED TO BE LOCATED; BREATHERS SET AT THE DOWNSTREAM PROPERTY LINE AND CRUSHED OR REMOVED ACROSS THIS SITE. IF ANY OF THESE TILES EXTEND BEYOND THE LIMITS OF THIS PROJECT, THEY WILL NEED TO BE PROVIDED A POSITIVE OUTLET AND ALLOWED TO CONTINUE TO FUNCTION, AS IT IS ILLEGAL TO BLOCK OFF A PRIVATE "MUTUAL" TILE. 3 CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE IS NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 4 CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, 5 REQUIRED INSPECTIONS FOR CERTAIN STAGES OF WORK TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY R/W. 6 EXISTING PAVEMENT TO BE SAW CUT TO A CLEAN EDGE ADJACENT TO ANY WIDENING, AUXILIARY LANES, ETC. 7 NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 8 THERE IS TO BE NO DRIVEWAY ENCROACHMENTS INTO EASEMENTS BETWEEN LOTS. 9 IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES , THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN ONE-FOOT OF THE PROPOSED RIGHT-OF-WAY. 10 DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 11 ALL PAVING WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. 12 UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED SHALL BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGH-OF-WAY LINE. 13 DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY A THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WIT THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 14 ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND THE REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. BENCHMARK DATA A STANDARD USGS DISK IN CONCRETE STAMPED "95 RHP 752 1951" AT THE NORTHWEST CORNER OF 146TH STREET AND NORFOLK AND WESTERN RAILROAD, 18.5 FEET NORTH OF THE CENTERLINE OF 146TH STREET. ELEVATION: 751.46' (NGVD 1929) TBM 2 (TSC PROJECT NUMBER 5271.002): TOP OF THE WEST ANCHOR BOLT ON METAL TRAFFIC POLE, SW. QUADRANT OF 146TH STREET AND RIVER ROAD. ELEVATION: 760.79' (NGVD 1929) S & A TEMPORARY BENCHMARKS TBM #1 A BRONZE DISC SET IN THE EASTERN HEADWALL OF A CULVERT, 2.5 FEET SOUTH OF THE NORTH END OF HEADWALL, SAID CULVERT IS ALONG RIVER ROAD AND 1100 FEET + NORTHEAST OF THE ENTRANCE TO PRAIRIE TRACT ELEMENTARY SCHOOL. DISC STAMPED "HAM 25 1964" ELEVATION: 749.52' (NGVD 1929) TBM #2 A COPPERWELD AT THE RADIUS POINT OF ARCADIAN COURT. ELEVATION: 771.54' (NGVD 1929) TBM #3 A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER POLE NUMBER HM 14261, 20 FEET SOUTH OF SOUTH CURB OF 146TH STREET, 1150 FEET + EAST OF CHERRY TREE ROAD. ELEVATION: 785.49' (NGVD 1929) TBM #4 A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER POLE NUMBER HM 14273, 20 FEET SOUTH OF SOUTH CURB OF 146TH STREET, 630 FEET + WEST OF GREYLAN PLACE. ELEVATION: 759.73' (NGVD 1929) TBM #5 A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S RIDGE AND STAGHORN COURT. ELEVATION: 757.78' (NGVD 1929) TBM #6 A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S RIDGE AND PLANTATION LANE. ELEVATION: 773.87' (NGVD 1929) TBM #7 A COPPERWELD AT THE RADIUS POINT OF PECOS COURT. ELEVATION: 770.76' (NGVD 1929) TBM #8 A COPPERWELD AT THE CENTERLINE INTERSECTION OF CHERRY TREE ROAD AND KLINGENSMITH BLVD. ELEVATION: 773.68' (NGVD 1929) EARTHWORK EXCAVATION A EXCAVATED MATERIAL THAT IS SUITABLE MAY BE USED FOR FILLS. ALL UNSUITABLE MATERIAL AND ALL SURPLUS EXCAVATED MATERIAL NOT REQUIRED SHALL BE REMOVED FROM THE SITE. B PROVIDE AND PLACE ANY ADDITIONAL FILL MATERIAL FROM OFFSITE AS MAY BE NECESSARY TO PRODUCE THE GRADES REQUIRED ON PLANS. FILL OBTAINED FROM OFFSITE SHALL BE OF QUALITY AS SPECIFIED FOR FILLS HEREIN AND THE SOURCE APPROVED BY THE DEVELOPER. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR FOR ANY COSTS FOR FILL NEEDED. REMOVAL OF TREES A.ALL TREES AND STUMPS SHALL BE REMOVED FROM AREAS TO BE OCCUPIED BY A ROAD SURFACE OR STRUCTURE AREA. TREES AND STUMPS SHALL NOT BE BURIED ON SITE. PROTECTION OF TREES A THE CONTRACTOR SHALL, AT THE DIRECTION OF THE DEVELOPER, ENDEAVOR TO SAVE AND PROTECT TREES OF VALUE AND WORTH WHICH DO NOT IMPAIR CONSTRUCTION OF IMPROVEMENTS AS DESIGNED. B IN THE EVENT CUT OR FILL EXCEEDS 0.5 FOOT OVER THE ROOT AREA, THE DEVELOPER SHALL BE CONSULTED WITH RESPECT TO PROTECTIVE MEASURE TO BE TAKEN, IF ANY, TO PRESERVE SUCH TREES. REMOVAL OF TOPSOIL A ALL TOPSOIL SHALL BE REMOVED FROM ALL AREAS BENEATH FUTURE PAVEMENTS OR BUILDING. TOPSOIL REMOVAL SHALL BE TO A MINIMUM DEPTH OF 6 INCHES OR TO THE DEPTH INDICATED IN THE GEOTECHMICAL REPORT PROVIDED BY THE DEVELOPER TO BE EXCAVATED OR FILLED. TOPSOIL SHOULD BE STORED AT A LOCATION WHERE IT WILL NOT INTERFERE WITH CONSTRUCTION OPERATIONS. THE TOPSOIL SHALL BE FREE OF DEBRIS AND STONES. UTILITIES A RULES AND REGULATION GOVERNING THE RESPECTIVE UTILITY SHALL BE OBSERVED IN EXECUTING ALL WORK UNDER THIS SECTION. B IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE LOCATION OF EXISTING UNDERGROUND UTILITIES 2 WORKING DAYS PRIOR TO COMMENCING WORK. FOR UTILITY LOCATIONS TO BE MARKED CALL TOLL FREE 1-800-382-5544 WITHIN INDIANA OR 1-800-428-5200 OUTSIDE INDIANA. SITE GRADING A DO ALL CUTTING, FILLING, COMPACTING OF FILLS AND ROUGH GRADING REQUIRED TO BRING ENTIRE PROJECT AREA TO SUBGRADE AS SHOWN ON THE DRAWING. B THE TOLERANCE FOR PAVED AREAS SHALL NOT EXCEED 0.05 FEET ABOVE ESTABLISHED SUBGRADE. ALL OTHER AREAS SHALL NOT EXCEED 0.05 FEET PLUS OR MINUS THE ESTABLISHED GRADE. PROVIDE ROUNDINGS AT TOP AND BOTTOM OF BANKS AND OTHER BREAKS IN GRADE. C THE ENGINEER SHALL BE NOTIFIED WHEN THE CONTRACTOR HAS REACHED THE TOLERANCE AS STATED ABOVE, SO THAT FIELD MEASUREMENTS AND SPOT ELEVATIONS CAN BE VERIFIED BY THE ENGINEER. THE CONTRACTOR SHALL NOT REMOVE HIS EQUIPMENT FROM THE SITE UNTIL THE ENGINEER HAS VERIFIED THAT THE JOB MEETS THE ABOVE TOLERANCE. 55115PYT-S5THE GROVE at THE LEGACYAEC BKR CLAY TOWNSHIPHAMILTON COUNTY, INDIANA03/17/21DP I T E S G E E O TS R P RTE WLE D E HVADIRJ .ADNINAI EEG NIRENOILA NS F EPRO STATE OF S File Name:S:\55115PYT-S5\DWG\C200 - Site Development Plan.dwg - C200Modified / By:May 12, 2021 3:27:35 PM / ecarsonPlotted / By:May 13, 2021 8:37:16 AM / Erik Carson05/11/21REVISED PER CITY OF CAMEL & CLIENT COMMENTSAEC...HORIZONTAL DATUM SHALL BE BASED ON INDIANA STATE PLANE COORDINATES, NAD83. HORIZONTAL CONTROL/COORDINATE: ℄ MONUMENT N: 1728602.73 E: 221845.61 ALICE PAUL LANE & KNIGHTSTOWN WAY ℄ MONUMENT N: 1727940.59 E: 221845.61 JAMES DEAN DRIVE & KNIGHTSTOWN WAY ℄ MONUMENT N: 1727368.59 E: 222151.58 CUL-DE-SAC BEN KINGSLEY COURT REFER TO SHEET C602 FOR STORM SEWER TABLE LEGEND DENOTES CONSTRUCTION LIMITS EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER LINE EXISTING CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED CONTOUR PROPOSED WATER LINE PROPOSED SWALE PROPOSED GRADE ELEVATION PROPOSED 5' SIDEWALK (BY HOME BUILDER) (DEVELOPER SHALL INSTALL SIDEWALKS ALONG ALL COMMON AREAS) Ù ADA RAMP TO BE INSTALLED PROPOSED CURB w/ 6" UNDERDRAIN PROPOSED 6" SUB-SURFACE DRAIN LOT NUMBER PAD GRADE MINIMUM FINISH FLOOR ELEVATION MINIMUM LOWEST ADJACENT GRADE MFF=850.70 MINIMUM FINISH FLOOR ELEVATION IS BASED OFF OF THE FOLLOWING CRITERIA: 1. 12" (1.0') ABOVE THE NEAREST UPSTREAM OR DOWNSTREAM SANITARY MANHOLE, WHICHEVER IS LOWEST. 2. 15" (1.25') ABOVE THE HIGHEST ROAD ELEVATION 3. 6" (0.5') ABOVE THE HIGHEST MLAG MLAG MINIMUM LOWEST ADJACENT GRADE (FLOOD PROTECTION) B.L.BUILDING SETBACK LINE M.E.MATCH EXISTING H.P.HIGH POINT L.P.LOW POINT GRD. CHG.GRADE CHANGE DENOTES REVERSE CURB LOCATIONS STORM SYSTEM STORM SEWERS FOR THIS DEVELOPMENT WILL BE PUBLIC STORM WATER CONTROLS SHOWN ON THE INITIAL SWPPP (C300) SHOULD BE INSTALLED AS SOON AS PRACTICAL. CONTACTS CARMEL UTILITIES FOR WATER LOCATES (317) 571-2648 RISER 300 850.0 MFF=850.70 MLAG=850.2 GRAPHIC SCALE ( IN FEET ) 1" = 50 FT FLOOD STATEMENT BASED ON THE 11/19/2014 FIRM PANEL 180567C0231G A PORTION OF THE PROPOSED DEVELOPMENT LIES WITHIN A ZONE X, 0.2 PERCENT CHANCE (500 YR FLOOD PLAIN) FLOOD HAZARD. BASED ON THE WEST FORK WHITE RIVER PROFILE FOR THIS AREA, THE 0.2 PERCENT CHANCE ELEVATION IS BELOW THE FINISHED GROUND ELEVATION OF THE PROPOSED DEVELOPMENT NOTE: ALL DWELLINGS ARE SLAB ON GRADE CONSTRUCTION. NO SUMP PUMP CONNECTIONS ARE REQUIRED