HomeMy WebLinkAboutA101 Floor Plan118HALL
115ABREAKRM
119OFFICE
117RECOVERYCAGES
103EXAM
104EXAM
105EXAM
107HALL
109LAB/PHARM
108LAB/PHARM
111SURGERY
113X-RAY
110TREATMENTAREA
106EXAM
114OFFICE 112ISO
101EXAM
116STOR.
5
A8206
A820
7
A820
100WAITING AREA
4
A820
2
A820
1
A820
115BEXSTTLT
EXST BLDG FIRERISER (NIC)
3
A820
3
A820
3
A820
3
A820
3
A820
8
A820
18
A820
102TLT
2
A101
W1A
W1A
W1AW1AW1A W1AW2AW1AW1AW1AW1A W1AW1A W3A100B101B
101C
102
106B 101A106A
105A
104A
103A
105B
104B
103B
100A
112111113114119115A116115BW1A
W1A
W1A
W1A
W3A
W1A
W2A
W1A
W1A
W1A
118
1
10'-6"
77'-11 14" (VIF)
8'-134" 9'-6" 9'-6" 28'-4" 10'-3 12"8'-112" +/- 3'-8"12'-1 12"7'-412" 9'-9"8'-0" 11'-0"
20'-0"
6'-1134"
9'-0"
21'-4"
4'-8" 6'-6" 10'-5 12"
22'-5 12"
9"9"11"
22'-5 12"16'-4" 19'-4" 14'-4 14"
2'-8"4'-7 34"3'-1" +/-12'-10 34"7'-10" 7'-10" 7'-10" 7'-10"4'-6" 7'-2"2
4
3
TYP
6
6
3
5
SIM
5
5
6 7
7
TYP
7
7
TYP7
8
8
8
12
TYP
10
13
14
15
18
17
18
18
21
16
3'-8"
18
20
19
11
W3A102TLT
GB1 GB2
TT1
GB1
M1
SD1
TD1
ND1
9
10
11
1 FLOOR PLAN
1/4"=1'-0"
A. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL
DIMENSIONS AND JOB CONDITIONS. ANY DEVIATION FROM
WHAT IS NOTED IN DRAWINGS SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT IMMEDIATELY.
B. ALL DIMENSIONS SHOWN ARE FACE OF BRICK, MASONRY OR
METAL STUD FRAMING, UNLESS OTHERWISE NOTED.
C. PROVIDE DEEP LEG DEFLECTION TRACK AT ALL METAL STUD
CONNECTIONS WITH STRUCTURE ABOVE, TYPICAL.
D. PROVIDE FIRE RATED WOOD BLOCKING IN METAL STUD WALLS
FOR ANY WALL SUPPORTED ITEMS.
E. PROVIDE APPROVED FIRE RATED STOPPING MATERIALS IN ANY
OPENINGS IN FIRE RATED ASSEMBLIES.
F. REFER TO DOOR AND WINDOW SCHEDULES FOR ALL MATERIALS,
FINISHES, AND HARDWARE INFORMATION.
G. REFER TO EXTERIOR ELEVATIONS FOR ALL BRICK, MASONRY, AND
OTHER EXPANSION JOINT LOCATIONS.
H. ALL MATERIALS LOCATED IN CEILING PLENUM SHALL BE RATED
FOR SUCH INSTALLATION OR PROTECTED TO PROVIDE
COMPLIANCE. THIS INCLUDES BUT IS NOT LIMITED TO
INSULATION (FHC 25/50) POWER AND LOW VOLTAGE WIRING,
TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY AND DRAIN
LINES AND SUPPORTING BRACKETS AND/OR BLOCKING FOR
CEILING HUNG ITEMS.
I. PRIOR TO ORDERING ANY PRODUCTS, CONTRACTOR SHALL
SUBMIT SAMPLES TO THE ARCHITECT OF ALL FINISH MATERIALS
TO BE USED ON THE PROJECT. THE CONTRACTOR SHALL BEAR
SOLE RESPONSIBILITY FOR ANY MATERIALS ORDERED
INCORRECTLY WHEN THAT MATERIAL WAS NOT REVIEWED BY
THE ARCHITECT.
J. PROVIDE CONCRETE FILLED STEEL PIPE BOLLARDS AT ALL
REQUIRED UTILITY EQUIPMENT LOCATIONS SUCH AS GAS METERS,
ELECTRICAL TRANSFORMER PANELS, ETC., COORDINATE WITH
UTILITY COMPANY AND CONTRACTORS, WHEN APPLICABLE, FOR
NECESSARY LOCATIONS. REFER TO CIVIL DRAWINGS FOR
BOLLARD SPECIFICATIONS AND ADDITIONAL INFORMATION.
K. ALL DOORS, UNLESS OTHERWISE NOTED, TO HAVE HINGE SIDE
SET 4" FROM CORNER SHOWN TO OUTSIDE OF FRAME.
L. UNLESS SPECIFIED ELSEWHERE, ALL INTERIOR SLABS AND SLAB
INFILLS TO BE FF-50/FL-35 OVERALL AND FF-35/FL-25 LOCAL.
M. ALL EXIT DOORS TO HAVE TACTILE EXIT SIGNAGE PER 703.4 OF
THE ANSI 117.1 2009
GENERAL NOTES
KEYED NOTES
KEY PLAN
210076
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
COPYRIGHT 2021, CURRAN ARCHITECTUREC
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
F :: 317 . 288 . 0753
O :: 317 . 288 . 0681
INDIANAPOLIS, IN 46216
5719 LAWTON LOOP E. DR. #212
VET CHECK CLINIC
1374 S. RANGELINE RD.
CARMEL, IN 46032
N
MEDICAL DR.S. RANGELINE RD.E. 116TH ST.
EXIST. STRUCTURE (NIC)
PROJECT LOCATION
PERMIT SET 4-26-21
FLOOR PLAN
A101
TOILET ACCESSORY SCHEDULE
MARK SYMBOL MFR # DESCRIPTION
TT1 BOBRICK
B-2888 MULTI-ROLL TOILET TISSUE DISPENSER
GB1
BOBRICK
B-5806 X 36
B-5806 X 42
36" AND 42" GRAB BARS
GB2 BOBRICK
B-5806 X 18 18" VERTICAL GRAB BAR
GB3 BOBRICK
B-6861 GRAB BAR FOR SHOWER STALL
M1 BOBRICK
B-165 MIRROR 2'-0" X 4'-0"
TD1 BOBRICK
B-3944 TOWEL DISPENSER / WASTE RECEPTACLE
SD1 BOBRICK
B-2112 SOAP DISPENSER
ND1
BOBRICK
B-353
B-270
B-353: SANITARY NAPKIN DISPOSAL UNIT AT GWB LOCATIONS.
B-270: SURFACE, MOUNT SANITARY NAPKIN DISPOSAL UNIT AT
PARTITIONS
SS1 BOBRICK
B-5181 FOLDING SEAT FOR ADA SHOWER
SH1 NOT APPLICABLE SHOWER HEAD
TP1 GENERAL
PARTITION
TOILET PARTITION AND/OR URINAL SCREEN POWDER COATED URINAL
SCREEN BOTTOM 12" FROM FLOOR AND TOP 60" MAX FROM FLOOR
N
2TOILET PLAN
1/2"=1'-0"
1. NEW PLASTIC LAMINATE COUNTERTOP WITH SOLID SURFACE
TRANSACTION TOP. PROVIDE 2" GROMMETS IN COUNTER AS
REQUIRED. SEE DETAIL 1 & 2/A820.
2. SCALE BY TENANT SEE DETAIL 1/A820.
3. NEW PLASTIC LAMINATE COUNTERTOP AND BASE CABINETRY.
4. NEW PLASTIC LAMINATE COUNTERTOP WITH UPPER SHELVING
CABINETRY.
5. NEW PLASTIC LAMINATE COUNTERTOP. SEE DETAIL 11/A820.
6. NEW PLASTIC LAMINATE COUNTERTOP, BASE & UPPER CABINETRY
WITH SINGLE STAINLESS STEEL SINK.
7. EQUIPMENT PROVIDED BY TENANT AND INSTALLED BY GC.
SHOWN FOR REFERENCE ONLY. COORDINATE WITH TENANT
FOR ANY REQUIRED F.R., BLOCKING , POWER, ETC.
8. REPAIR EXISTING DOORS TO LIKE NEW CONDITION. REPLACE
DOOR/HARDWARE AS REQUIRED.
9. NEW ADA COMPLIANT TOILET.
10. NEW ADA COMPLIANT WALL HUNG LAVATORY. PROVIDE SCALD
GUARD PIPE WRAP ON SUPPLY AND WASTE LINES.
11. CENTER WALL ON STOREFRONT FRAMING. PROVIDE BRAKE
METAL TRIM @ END W/HEMMED EDGES. PROVIDE NEOPRENE
GASKET BETWEEN TRIM AND FRAME.
12. NEW FURNITURE BY TENANT.
13. EXISTING RESTROOM FIXTURES TO BE CLEANED AND INSPECTED.
REPLACE AS REQUIRED IF THEY CAN NOT BE MADE FUNCTIONAL
OR INTO LIKE NEW CONDITION.
14. EXISTING WATER HEATER LOCATION. NEW SINKS TO BE FED
FROM THIS WATER HEATER.
15. NEW WASHER AND DRYER UNIT BY TENANT AND INSTALLED BY
GC. PROVIDE ELECTRIC, PLUMBING, AND VENTILATION
CONNECTIONS AS NEEDED.
16. NEW ADA COMPLIANT, FIBERGLASS SHOWER UNIT. CONNECT
TO EXISTING PLUMBING/DRAIN LINES, AND INSTALL NEW LINES
AND CONNECTIONS AS NEEDED. VERIFY DIMS W/SHOWER UNIT
MFR. PROVIDE GB3, SH1, SS1, AND ROD/CURTAIN. SEE DETAIL
8/A002.
17. EXIST. MOP SINK TO REMAIN.
18. NEW EQUIPMENT BY TENANT.
19. PROVIDE WALL FURRING WITH 3 58" METAL STUDS AND R-11 BATT
INSULATION. COVER W/VAPOR BARRIER AND 58" GYP. BOARD
(FULL HEIGHT) ALIGN FACE OF WALL W/ADJACENT, EXISTING
WALL SYSTEM.
20. ALIGN FINISH FACE OF WALL W/EDGE OF EXISTING OPENING.
21. PROVIDE WATER LINE FOR ICE/WATER DISPENSER IN
REFRIGERATOR.
06/16/21