Loading...
HomeMy WebLinkAboutVETCHECK comcheckCOMcheck Software Version 4.1.5.1 Interior Lighting Compliance Certificate Project Title: 90.1 (2007) Standard Project Type:Alteration Construction Site: 1374 S. RANGELINE RD. CARMEL, IN 46032 Owner/Agent:Designer/Contractor: JERRY HOFFMAN US ARCHITECTS 9200 W. SMITH ST. YORKTOWN, IN 47396 765-405-1220 jhoff@usarchitectsmuncie.com Project Information Energy Code: INTERIOR ELECTRICAL WORK FOR VETCHECK Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Hospital:Exam/Treatment 1047 1.50 1570 2-Common Space Types:Office - Open Plan 1977 1.10 2175 3745Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Hospital:Exam/Treatment (1047 sq.ft.) 2X4 LED: A: Other:1 20 50 1000 Common Space Types:Office - Open Plan (1977 sq.ft.) 2X4 LED: A: Other:1 25 50 1250 2X2 LED: B: Other:1 1 28 28 LED VANITY FIXTURE: C: Other:1 2 25 50 PENDANT FIXTURE BY OWNER: D: Other:1 3 60 180 LED DOWNLIGHT: E: Other:1 1 21 21 LED SHOWER LIGHT: SH: Other:1 1 60 60 2589Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: INTERIOR ELECTRICAL WORK FOR VETCHECK C:\Users\Whitney\Desktop\T&W_VET-PET\STATE\VETCHECK.cck 04/22/21Report date: 51 ofPage Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.5.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2007) Standard Section # & Req.ID Plan Review Complies?Comments/Assumptions 4.2.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. 8.4.1.1, 8.4.1.2 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: INTERIOR ELECTRICAL WORK FOR VETCHECK C:\Users\Whitney\Desktop\T&W_VET-PET\STATE\VETCHECK.cck 04/22/21Report date: 52 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions 9.4.1.1 [EL1]2 Automatic controls to shut off all building lighting installed in buildings >5,000 ft2. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.2 [EL2]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.1.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.2 [EL5]3 Ballasted one and three lamp fixtures with >30 W/lamp have two lamp tandem wired ballasts when >=2 fixtures in same space on same control. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.4.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.6.2 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: INTERIOR ELECTRICAL WORK FOR VETCHECK C:\Users\Whitney\Desktop\T&W_VET-PET\STATE\VETCHECK.cck 04/22/21Report date: 53 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions 8.7.1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. 8.7.2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. 9.2.2.3 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: INTERIOR ELECTRICAL WORK FOR VETCHECK C:\Users\Whitney\Desktop\T&W_VET-PET\STATE\VETCHECK.cck 04/22/21Report date: 54 ofPage Project Title: Data filename: INTERIOR ELECTRICAL WORK FOR VETCHECK C:\Users\Whitney\Desktop\T&W_VET-PET\STATE\VETCHECK.cck 04/22/21Report date: 55 ofPage