Loading...
Photometric Plan with fixturesS MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 S MH: 9 4.8 0.7 1.8 5.2 3.5 0.8 1.6 5.3 16.7 4.9 0.8 1.9 11.7 5.8 3.4 0.8 1.5 5.7 9.9 4.0 0.7 1.6 8.3 0.6 1.4 0.0 0.0 1.4 0.2 0.4 0.1 0.3 2.1 6.7 4.2 6.6 4.4 5.2 5.1 4.3 6.3 1.5 0.3 0.6 3.8 6.1 3.8 6.8 3.7 6.6 4.6 5.6 4.3 0.7 0.1 0.1 0.4 0.8 0.9 1.2 1.3 1.0 0.8 0.7 0.9 0.6 0.3 0.4 0.8 0.8 0.8 1.0 1.2 1.4 1.0 0.8 0.6 0.2 0.1 0.0 0.1 1.6 0.4 0.8 2.3 0.1 0.0 0.7 1.8 0.0 5.8 3.5 0.8 1.6 5.7 14.1 4.6 0.8 1.8 10.5 7.1 3.5 0.8 1.6 6.5 8.8 3.7 0.7 1.6 7.4 0.6 1.4 0.0 0.0 0.0 0.2 0.4 8.3 4.7 8.2 5.2 6.2 6.2 5.2 7.7 1.7 0.3 0.7 4.5 7.5 4.3 8.5 4.2 8.0 5.4 6.7 5.2 2.3 2.2 2.5 2.2 2.3 2.3 2.1 2.2 1.0 0.3 0.5 1.6 2.4 2.1 2.5 2.1 2.5 2.3 2.3 1.8 10.9 5.2 10.6 6.0 7.8 7.6 6.2 9.9 1.8 0.3 0.7 5.6 9.7 4.7 11.1 4.6 10.3 6.4 8.3 6.6 0.0 0.0 0.0 0.1 0.7 1.6 6.6 3.4 0.7 1.5 6.1 9.3 3.8 0.8 1.6 7.8 10.0 4.0 0.8 1.7 8.2 8.0 3.7 0.8 1.6 7.1 0.7 1.5 Luminaire Schedule Symbol Qty Label Arrangement Lum. Lumens LLF Lum. Watts Description 60 S WALL MOUNT 3536 0.900 34.6 SLIMFC37N Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min Paved Roadways Illuminance Fc 3.38 16.7 0.0 N.A. N.A. All electrical work shall comply with National, State, and Local codes including and not limited to the National Electric Code, NFPA 101 Life Safety Code, ASHREA and /or IECC Energy Codes. The information contained in this document is proprietary to CBMC Lighting Solutions. This document is prepared for a specific site and incorporates calculations based on data available from the client at this time. By accepting and using this document, the recipient agrees to protect its contents from further dissemination, (other than that within the organization necessary to evaluate such specification) without the written permission of CBMC Lighting Solutions. the contents of this document are not to be reproduced or copied in whole or in part without the written permission of CBMC Lighting Solutions. copyright © 2018 CBMC Lighting Solutions all rights reserved.CB17919-SITE 5855 KOPETSKY DR. SUITE G. | INDIANAPOLIS, IN 46217 317-780-8350| WWW.CBMCINC.COM SITE LAYOUTSEE MORE This lighting pattern represents illumination levels calculated from laboratory data taken under controlled conditions in accordance with IESNA approved methods. Actual performance of any manufacturer's luminaire may vary due to variation in electrical voltage, tolerance in lamps and LED lumen package, location adjustments, and other variable field conditions. Contractor to check and verify all dimensions on site before commencing any work shown. Magnolia Project No: Scale: Date: Drawn By: LP1Drawing No: SJM - 1" = 20' 3/17/21 LIGHTING NOTES: - Mounting Height = 9' - Light Loss Factor = 0.90 - Footcandle Values Calculated @ Grade - Reflectance Values - 80/50/20 (office spaces) 50/30/20 (warehouse areas) National Lighting Vendor: For pricing and technical assistance contact: Rob Thomson of CBMC INC, tel# 317-828-4119, rthomson@cbmcinc.com 06/15/21