Loading...
HomeMy WebLinkAboutS000.2ELEVATIONS EC2N, HR2Z, HR2I, NC2H ADDED TO IN SET STRUCTURAL REVISIONS2017-12-01 DELTA 7.0{\H0.63636x; (ALL DIVISIONS AFFECTED)}{\LGENERAL REVISIONS (NOT CLOUDED)}COORDINATE ALL STONE LEDGE AND PORCH FTGSCHANGED G.T. TO (2)2x10 IN GARAGE{\L2ND FLOOR FRAMING (S-2.X'S)}COORDINATE ALL STONE LEDGE AND PORCH FTGSREVISED W10x BEAM SIZE AT OPT. SUNROOM{\LOPTIONS FRAMING (SO-X.X'S)}ADDED BLOCKING AT REAR OPTIONS w/ GATH. EXT.ADDED COVERED PORCH OPTIONS2018-02-09 DELTA 7.1{\H0.63636x; (MI DIVISION AFFECTED)}REVISED CANT'D BEAM CALLOUT ON ELEV. HR2V-10{\L2ND FLOOR FRAMING (S-2.X'S)} UPDATED GRADE BRICK GRAPHICS @ ELEVS. CT2T, EC30, HR2H, HR2C, HR2Y, AND PR2H PER ARCH2019-05-10 DELTA 8.0{\H0.63636x; (PCR - ALL DIVISIONS AFFECTED)}{\LGENERAL REVISIONS (NOT CLOUDED)} {\L2ND FLOOR FRAMING (S-2.X'S)}ADDED OPT. FLEX WDWS & SIDE WDW OPT. OH DIVISON: 2018 RCO UPDATE - LATERAL REVISION{\L1ST FLOOR FRAMING FRAMING (S-1.X'S)}IL DIVISON: REMOVED W10x BASEMENT BEAM OPTIONS {\LROOF FRAMING (S-3.X'S)}REVISED WDW LOCATION AT BEDROOM 2 {\LOPTIONS FRAMING (SO-X.X'S)} UPDATED FINISHED BASEMENT STORAGE DOOR (NON-STRUCT) PER ARCHREVISED BEDROOM 4 CLOSET DOOR (NON-STRUCT) PER ARCH OH DIVISIONS: REMOVED W8x BASEMENT BEAM OPTIONS IL DIVISION ONLY: REMOVED ALL LVL/LSL WINDOW HEADER SPECS WHERE MSR OPTION PROVIDEDOH DIVISION ONLY: REMOVED ALL MSR WINDOW HEADER SPECS WHERE LVL/LSL OPTION PROVIDEDOH/MI DIVISIONS ONLY: REMOVED ALL GARAGE DOOR HEADER LINTEL OPTIONS EXCEPT OPTION C (BOLTED BACK LINTEL) IL DIVISION ONLY: REMOVED ALL LVL/LSL WINDOW HEADER SPECS WHERE MSR OPTION PROVIDEDOH DIVISION ONLY: REMOVED ALL MSR WINDOW HEADER SPECS WHERE LVL/LSL OPTION PROVIDED IL/OH/MI DIVISIONS ONLY: REMOVED ALL MSR WINDOW HEADER SPECS WHERE LVL/LSL OPTION PROVIDED @ WALKOUT/DAYLIGHT BASEMENTS IL DIVISION ONLY: REMOVED ALL LVL GARAGE BEAM OPTIONS & ADDED STEEL POST ALTERNATEIN/MI DIVISIONS ONLY: UPDATED ALL 22" LVL TO 24" LVLOH/MI DIVISIONS ONLY: REMOVED ALL STEEL GARAGE BEAM OPTIONS REMOVED MO + KY SETREVISED GENERAL NOTES & DETAILS OHIO DIVISION 2018 RCO UPDATE - LATERAL REVISION OHIO DIVISON: 2018 RCO UPDATE - LATERAL REVISION OHIO DIVISON: 2018 RCO UPDATE - LATERAL REVISION IN/MI DIVISION: UPDATED BASEMENT BEAMS PER REDLINES UPDATED EXTERIOR GARAGE WALL STUD SPECS \A1;REVISED GARAGE BEAM FROM (2)1{\H0.7x;\S3#4;}"x24" LVL DROPPED TO (3)1{\H0.7x;\S3#4;}"x18" LVL DROPPED2019-07-26 DELTA 8.1{\H0.63636x; (MI DIVISION AFFECTED)}{\LGENERAL REVISIONS (NOT CLOUDED)} \A1;OH DIVISION: ADDED ELEVATION HR2F, HR2G-CS01, CR2G-CS01, HR2U-CS01 & EC3M-CS02 2 CAR FRONT, 3 CAR FRONT, 2 CAR SIDE, 3 CAR SIDE GARAGES2019-12-06 DELTA 8.2{\H0.63636x; (IN&OH DIVISIONS AFFECTED)}{\LGENERAL REVISIONS (NOT CLOUDED)} {\L2ND FLOOR FRAMING (S-2.X'S)}IN DIVISON: 2020 CODE UPDATE - LATERAL REVISION{\L1ST FLOOR FRAMING FRAMING (S-1.X'S)} {\LROOF FRAMING (S-3.X'S)}{\LOPTIONS FRAMING (SO-X.X'S)}IN DIVISION 2020 CODE UPDATE - LATERAL REVISIONIN DIVISON: 2020 CODE UPDATE - LATERAL REVISIONIN DIVISON: 2020 CODE UPDATE - LATERAL REVISION (c) Copyright 2019 PulteGroup, Inc.1900 Golf Road - Suite 300Schaumburg, Illinois 60173Midwest Zone Office03/17/2014Rick Starkey GARAGE LEFT ---- Maplevalley 1039.300 12-01-2017 805/10/2019PCR REVISIONS PRODUCT MANAGERINITIAL RELEASEDATE:REV#DATE/DESCRIPTION GARAGE HANDING SHEET PLAN NAME SPECIFICATION LEVEL NPC CHILD NUMBER 8.212/06/2019CS-ADDED ELEV. S-0.1...STRUCTURAL NOTES - IN06/16/21