Loading...
HomeMy WebLinkAboutC300CARMEL-CLAY PARKS & RECREATION BOARD TRACT A - INSTR. #9809807935 TRACT B - INSTR. #9809807936 W W WEEEEEEEEEEEEEEC C C C G G G EE EOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU EN00°09'42"W 761.17'S89°59'52"W 775.74'S00°08'28"W 894.61 'N41°05'18"E 1 7 4. 60'W SED D DD DD DDD D D D D D D D D D DD D DDD D D D D DD D D DDD DDDDDDDDDD D DDDD D D D D DD D D D D D D DDD D DDDD DDSPEARS SPEARS SP EA RS SP EA R S SP EA RS POND EMERGENCY SPILLWAY POND SUBDRAIN MONITORING WELL BMP - NATIVE BASIN PLANTINGS BMP - PERMIABLE PAVERS BMP - HOOD AND SUMP IN STRUCTURE 201 ESP E A R S SPEAR SSPEARSSPEARSSPEARS STORM SEWER STRUCTURE DATA TABLE STRUCTURE NUMBER 100 101 200 201 202 203 204 205 206 300 301 302 303 304 TOP OF CASTING Refer to Details 751.66 754.00 753.13 754.48 756.34 757.76 758.10 759.37 759.13 754.12 756.01 756.78 757.49 758.04 STRUCTURE TYPE FLARED END SECTION 2'x2' OUTLET CONTROL STRUCTURE (SEE DETAILS) FLARED END SECTION 30" DIA. NYLOPLAST INLET W/ ENVIROHOOD SUMP ELEV.= 748.86 EXISTING AREA INLET 30" DIA. NYLOPLAST INLET 24" DIA. NYLOPLAST INLET 6" CLEANOUT 6" CLEANOUT FLARED END SECTION 24" DIA. NYLOPLAST INLET 24" DIA. NYLOPLAST INLET 24" DIA. NYLOPLAST INLET 6" CLEANOUT CASTING TYPE ??? NEENAH R-3402-E ??? SOLID NEENAH R-1772 Standard Standard SOLID SOLID ??? Standard Standard Standard SOLID INVERT INV IN (E)= 750.14 (12" HDPE) INV OUT (W)= 750.91 (12" HDPE) INV IN (SE)= 752.00 (15" HDPE) INV IN (NE)= 752.46 (12" HDPE) INV OUT (NW)= 752.36 (15" HDPE) INV IN (N)= 754.46 (12" HDPE) INV OUT (SW)= 754.36 (12" HDPE) INV IN (W)= 754.81 (12" HDPE) INV IN (NW)= 755.25 (6" PVC) INV OUT (S)= 754.71 (12" HDPE) INV OUT (E)= 755.20 (12" HDPE) INV OUT (SE)= 756.18 (6" PVC) INV OUT (S)= 756.62 (6" PVC) INV IN (N)= 752.99 (12" HDPE) INV IN (N)= 753.31 (12" PERFORATED HDPE) INV OUT (S)= 753.21 (12" HDPE) INV IN (NE)= 754.03 (12" PERFORATED HDPE) INV OUT (S)= 753.93 (12" PERFORATED HDPE) INV IN (NE)= 754.89 (6" PERFORATED HDPE) INV OUT (SW)= 754.79 (12" PERFORATED HDPE) INV OUT (SW)= 755.10 (6" PERFORATED HDPE) DETAIL REFERENCE N/A N/A N/A N/A N/A N/A DETAIL 7, SHEET 306 DETAIL 7, SHEET 306 DETAIL 7, SHEET 306 DETAIL 6, SHEET 306 DETAIL 5, SHEET 306 DETAIL 5, SHEET 306 DETAIL 5, SHEET 306 DETAIL 5, SHEET 306 DETAIL 5, SHEET 306 DETAIL 1, SHEET 306 DETAIL 8, SHEET 306 DETAIL 8, SHEET 306 DETAIL 8, SHEET 306 N/A STORM SEWER PIPE DATA TABLE UPSTREAM STRUCTURE 101 201 203 204 301 302 303 DOWNSTREAM STRUCTURE 100 200 202 203 300 301 302 SIZE 12" 15" 12" 12" 12" 12" 12" MATERIAL HDPE HDPE HDPE HDPE HDPE PERFORATED HDPE PERFORATED HDPE LENGTH 61' 66' 80' 126' 20' 138' 139' SLOPE 1.25% 0.54% 0.31% 0.31% 1.15% 0.45% 0.55% 10 9 a b c d 8 7 6 e f g h10 9 8 7 6 REVISIONS AND ISSUES5 4 3 2 1 PREPARED FOR:PROJECT NO. SHEET NO.a b c d 5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYe DATE:1 E N G I N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netf hKnow what'sbelow. before you dig.Call R gSection 1, Township 17 North, Range 3 East, Clay Township, Hamilton County, Indiana W200371CARMEL, IN 46033AQW20037103/05/2020BSAQLAWRENCE W. INLOW PARKPHASE II IMPROVEMENTSRUSSELL L. WEBSTER II, PE No. 11900318 03/23/2021RUSSELLL.WEBST ER IIPROFESSIONA L E NGINEE RRE G I S T ER E DINDIA N A PE11900318 STATE OF NO. C300GRADING PLANW S N E INTERCEPT EX. SEWER LINE AT STRUCTURE 201 REMOVE REMAINING STORM AND SEAL EXISTING AREA INLET PER CITY OF CARMEL STANDARDS CURB SPOT ELEVATIONS 03/22/2021 AMQ1 1 1 ULTIMATE DISCHARGE DISCHARGE SUMMARY PEAK DISCHARGE (CFS) RETURN PERIOD 10 YR. 100 YR. 3.655 3.49 ALLOWABLE ACTUAL W/OFFSITE 7.374 6.74 NET SITE ACREAGE (MINUS ROW) OFF-SITE ACREAGE DETENTION VOLUME REQUIRED DETENTION VOLUME PROVIDED 4.04 ACRES 0.00 ACRES 16,656 CF 16,656 CF 2 2 TYP. CONSTRUCTION LIMITS 2 LIMITS OF DISTURBANCE CLARIFICATION 04/16/2021 AMQ2CONSTRUCTION LIMITS 2 2 3 EMERGENCY OVERFLOW= LEGEND: =PONDING LIMITS FOR A CLOGGED CONDITION 2 TYP. 2 3 REVISED LIMITS OF DISTURBANCE32 06/17/21