Loading...
HomeMy WebLinkAboutC804POST CONNECTION TO BE DESIGNED AS PART OF THE ENGINEERED SHOP DRAWINGS OF PAVILION BRICK VENEER TO MATCH BUILDING BRICK VENER (SEE ARCHITECTURAL PLANS) 1/2" STEEL DOWEL @ 24" O.C. GREASE ONE SIDE 1/2" EXPANSION JOINT TYP. FILL TOP WITH JOINT SEALANT TO MATCH CONC. COLOR #4 REBAR @ 24" O.C. CAST STONE CAP TO MATCH BUILDING CAST STONE (SEE ARCHITECTURAL PLANS) 6" X 8" X 16" CMU, GROUT FILLED CAVITY HORIZONTAL JOINT REINFORCEMENT; EVERY OTHER COURSE, TERMINATE @ CONTROL JOINTS 4" CONC PAD W/ 6X6-10X10 WWM #4 REBAR, CONTINUOUS #4 REBAR, CONTINUOUS #4 TRAVERSE REBAR @ 36" O.C. CONCRETE FOOTING 3,000 MIN. PSI CONCRETE FOOTING 4,000 MIN. PSI #4 TRAVERSE REBAR @ 36" O.C. COMPACTED SUBGRADE COLUMN DIMENSIONS TO BE CONFIRMED BY PAVILION MANUFACTURER 10 9 a b c d 8 7 6 e f g h10 9 8 7 6 REVISIONS AND ISSUES 5 4 3 2 1 PREPARED FOR:PROJECT NO. SHEET NO.a b c d 5 4 3 2 CHECKED BY:DRAWN BY:DESIGNED BY:DWG NAME:PROJECT NO.:DATE BYe DATE:1 ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netf hKnow what'sbelow. before you dig.Call R gSection 1, Township 17 North, Range 3 East, Clay Township, Hamilton County, IndianaW200371CARMEL, IN 46033AQW20037103/05/2020BSAQLAWRENCE W. INLOW PARKPHASE II IMPROVEMENTSRUSSELL L. WEBSTER II, PE No. 11900318 03/23/2021RUSSELLL.WEBST ER IIPROFESSIONA L E NGINEE RRE G I S T ER E DINDIA N A PE11900318 STATE OF NO. C804POLIGON GENERAL DETAILSPOLIGON PAVILION (NO SCALE) 1 C804 PAVILION COLUMN/FOOTER DETAIL (NO SCALE) 2 C804 1 1 POLIGON SHADE STRUCTURE DETAILS 03/22/2021 AQ1 06/17/21