HomeMy WebLinkAbout2100575 ADAMS RES 2ND FL LO BID16" &18" DEEPFLOORTRUSSES @16" O.C.
IMPORTANT
THISDRAWINGISFORFIELD PLACEMENT OF INDIVIDUAL
COMPONENTSONLY, AND DOESNOT CONSTITUTE AN
ENGINEERED DOCUMENT.
NOTE
PROPER BEARINGANDBEARINGDESIGN INCLUDING
ANCHORAGE, ISTHERESPONSIBILITY OF THE BUILDING
DESIGNER, ARCHITECT AND /OR BUILDINGENGINEER. REFER
TO INDIVIDUAL TRUSSDESIGNSFOR REACTIONS, MINIMUM
REQUIRED BEARINGSIZE, UPLIFT, AND ADDITIONAL LOADS.
84COMPONENTSDOESNOT ASSUME RESPONSIBILITYIN
THESE AREASOF CONCERN.
BRACING
ERECTION, TEMPORARY, AND PERMANENT BRACINGISTHE
RESPONSIBILITY OFTHE CONTRACTOR AND / OR BUILDING
DESIGNER. REFER TOINDIVIDUAL TRUSSDESIGNSFOR
ADDITIONAL BRACINGREQUIREMENTS. REFERTO BCSI-B1
SUMMARY SHEET. THE STRUCTURAL BUILDINGCOMPONENTS
ASSOCIATION COMMENTARY, AND RECOMMENDATIONSFOR
HANDLING, INSTALLING&BRACINGMETALPLATECONNECTED
WOOD TRUSSES. www.sbcindustry.com
INSTALLATION
DO NOT CUT, DRILL, OR ALTER TRUSSES. ANYQUESTIONS
CALL 84COMPONENTS. PROPER INSTALLATION, AND
HANDLINGOF COMPONENTSISTHE RESPONSIBILITY OF THE
ERECTINGCONTRACTOR. 84COMPONENTSMUST BE
NOTIFIED OF ANYPROBLEMS, AND AFFORDED THE
OPPORTUNITY TO REVIEW, AND MAKE NECESSARY
CORRECTIONS, OR NO BACK CHARGESWILL BE ACCEPTED
ORAPPROVED.
WARNING
WARNINGS, AND INSTRUCTIONSFORERECTION
OF COMPONENTSARE INCLUDED IN THE DELIVERY PACKAGE.
KEEP THISINFORMATION ON THE JOB SITE. THESE
DOCUMENTSWILLALSO BENEEDEDFORJOB SITE
INSPECTION. MISUSE AND IMPROPER INSTALLATION OF
COMPONENTSMAYRESULT IN FAILURE, BODILY INJURY, LOSS
OFPROPERTY, AND / ORLIFE.
FloorArea:
FloorSheathing:
4265.13SF
153.28 Sheets
FLOOR DATA
Job#: 2100575
PO#:
Date: 3/11/2021
Drawn By: BH
Designed By: BH
Checked By:
FLOOR LOADS:
TCLL: 40.0 lb/ft²
TCDL: 10.0 lb/ft²
BCDL: 5.0 lb/ft²
Live Load Deflection: L/480.000
Total Load Deflection: L/360.000
On-CenterSpacing: 24" U.N.O.
SHEETNUMBER:
F1.1
FloorTruss
Placement Plan
SCALE: NTS1850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-0916ADAMS RESIDENCE,2nd FLOOR TRUSSPLACEMENT PLAN2100575PRELIMINARY - NOT FOR CONSTRUCTIONTHIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDINGCONSTRUCTION.
06/22/21