HomeMy WebLinkAboutNina Price - Planset6 KW SYSTEM SIZE :7.92 KW DC STC VICINITY MAP SITE MAP (N.T.S) A-00 SITE MAP & VICINITY MAP NINA PRICE NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM DC SYSTEM SIZE (7.92 KW) 32°C -22°C 20 PSF 106MPH II B 25 A (1) SE6000H-US SOLAREDGE INVERTER BACKFEED BREAKER IN THE MSP WIND FLOW MAP (2) BRANCHES OF 11 MODULES SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.DC RATING OF SYSTEM AC RATING OF SYSTEM AC OUTPUT CURRENT NO. OF MODULES NO. OF INVERTERS POINT OF CONNECTION ARRAY STRINGING DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE SYSTEM DETAILS GOVERNING CODES INDIANA RESIDENTIAL CODE (IRC) 2020 INDIANA BUILDING CODE (IBC) 2014 INDIANA FIRE CODE (IFC) 2014 NATIONAL ELECTRIC CODE, NEC 2008 CODE BOOK, NFPA 70 SITE MAP & VICINITY MAPA - 00 SINGLE LINE DIAGRAM WIRING CALCULATIONS SYSTEM LABELING MODULE DATASHEET E - 01 E - 02 E - 03 STRUCTURAL ATTACHMENT DETAIL INVERTER DATASHEET OPTIMIZER DATASHEET ATTACHMENT DATASHEET DS - 01 DS - 02 DS - 03 DS - 04 S - 02 SHEET INDEX SHEET NO. SHEET NAME ARRAY LAYOUT S - 03 RACKING DATASHEETDS - 05 SITE DETAILS ASHRAE EXTREME LOW ASHRAE 2% HIGH GROUND SNOW LOAD WIND SPEED RISK CATEGORY WIND EXPOSURE CATEGORY (22) REC360AA BLACK MODULES (22) P370 SOLAREDGE OPTIMIZERSNO. OF OPTIMIZERS ROOF PLAN & MODULES S - 01 PV ARRAY ROOF 1 241 ' -9 " 78'-8"161'-10"191'-11" 138' 23'-4 " 25'-1"6 8 ' - 7 " 77'-2 "HA ZELWOOD DRDRIVE WA Y MSPUMACD INV (N) SE6000H-USSOLAREDGE INVERTER (N) AC DISCONNECT (E) UTILITY METER (OUTSIDE HOUSE) (E) MAIN SERVICE PANEL (INSIDE HOUSE) 3' SETBACK 06/23/21 S-01 & MODULES ROOF PLAN MODULE TYPE, DIMENSIONS & WEIGHT SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH IBC: RESIDENTIAL CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFT WIND LOADS, AND EQUIPMENT DEAD LOADS. * GENERAL INSTALLATION PLAN NOTES: 1) ROOF ATTACHMENTS TO TRUSSES SHALL BE INSTALLED AS SHOWN IN SHEET S-01 AND AS FOLLOWS FOR EACH WIND ZONE:. WIND ZONE 1: MAX SPAN 6'-0" O.C. WIND ZONE 2: MAX SPAN 4'-0" O.C. WIND ZONE 3: MAX SPAN 2'-0" O.C. 2) EXISTING RESIDENTIAL BUILDING IS AN ASPHALT SHINGLE ROOF WITH MEAN ROOF HEIGHT 15 FT AND 2"x4" WOOD ROOF RAFTER SPACED 24" O.C. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS. LEGENDS UM ACD PM MSP - UTILITY METER JB - AC DISCONNECT - PRODUCTION METER - MAIN SERVICE PANEL - VENT, ATTIC FAN (ROOF OBSTRUCTION) - JUNCTION BOX CP - COMBINER PANEL - CONDUIT - OPTIMIZER - FIRE SETBACK NUMBER OF MODULES = 22 MODULES MODULE TYPE = REC360AA BLACK MODULES WEIGHT = 43 LBS / 19.5 KG. MODULE DIMENSIONS = 67.8" X 40" = 18.83 SF NUMBER OF OPTIMIZER = 22 OPTIMIZER TYPE = P370 SOLAREDGE OPTIMIZERS NUMBER OF INVERTER = 1 INVERTER TYPE = SE6000H-US SOLAREDGE INVERTER DC SYSTEM SIZE: 7.92 KW AC SYSTEM SIZE: 6 KW INV - INVERTER M - METER MAIN COMBO PV ARRAY ROOF 1 MSP U M A CD INV (N) SE6000H-US SOLAREDGE INVERTER (N) AC DISCONNECT (E) UTILITY METER (OUTSIDE HOUSE) (E) MAIN SERVICE PANEL (INSIDE HOUSE) 3' SETBACK(E) BACK YARD (E) FRONT YA RDJBCONDUIT RUN ROOF ACCESS POINT ROOF ACCESS POINT 06/23/21 S-02 ARRAY LAYOUT (ROOF #1) ROOF DESCRIPTION: SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.MODULES - 22 ROOF TILT - 25° ROOF AZIMUTH - 134° TRUSSES SIZE - 2"X4" @ 24" O.C. LEGENDS - VENT, ATTIC FAN (ROOF OBSTRUCTION) - PV ROOF ATTACHMENT - RAIL - COUPLING - FIRE SETBACK - WIND ZONE II - WIND ZONE III - WIND ZONE I - RAFTERS / TRUSSES SOLAR MODULE 3' SETBACK ROOF #1 39'-6"18'-1"30'-5" 25'-10"9'06/23/21 PHOTOVOLTAIC MODULE GENERAL NOTES: 1. APPLICABLE CODE: 2020 INDIANA BUILDING CODE 7TH ED. & ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURERS' MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. 8. ALL RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURERS' INSTRUCTIONS. 9. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH IBC:BUILDING CHAPTER 16 AND IRC:RESIDENTIAL CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS. S-03 STRUCTURAL ATTACHMENT DETAILS STRUCTURAL ATTACHMENT DETAILS SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.IRONRIDGE XR100 SOLAR MODULE 5/16"x4" STAINLESS STEEL LAG SCREW WOOD SHEATHING RAFTERS RAFTERS IRONRIDGE XR100 WOOD SHEATHING IRONRIDGE (L MOUNT) IRONRIDGE FLASHFOOT2 IRONRIDGE (L MOUNT) IRONRIDGE FLASHFOOT2 06/23/21 NOTE: 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2008, NFPA 70 AND INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE. 2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTER SPACE IS INADEQUATE. E-01 SINGLE LINE DIAGRAM SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.SE6000H-US 240V 25 V SOLAREDGE INVERTER INVERTER SPECIFICATION MANUFACTURER MODEL NO. MAX. AC OUTPUT VOLTAGE AC OUTPUT CURRENT 6000 WMAX. OUTPUT POWER P370 11 A 15 A SOLAREDGE OPTIMIZER OPTIMIZER SPECIFICATION MANUFACTURER MODEL NO. SHORT CIRCUIT CURRENT(Isc) MAX. AC OUTPUT CURRENT 60VOPEN CIRCUIT VOLTAGE (Voc) ARRAY DETAILS DC SYSTEM SIZE AC SYSTEM SIZE TOTAL NO. OF MODULES 6 KW 22 7.92 KW NO. OF MODULE PER STRING NO. OF STRING 2 2@11 REC360AA BLACK 10.49 REC MODULE SPECIFICATION MANUFACTURER MODEL NO. SHORT CIRCUIT CURRENT(Isc) 43.9OPEN CIRCUIT VOLTAGE (Voc) 9.82RATED CURRENT (Impp) 36.7RATED VOLTAGE (Vmpp) 1 STRING OF 11 MODULES W/OPTIMIZERS 1 STRING OF 11 MODULES W/OPTIMIZERS DC UNGROUNDED G G G 60A AC DISCONNECT UNFUSED SE6000H-US SOLAREDGE INVERTER (3) #10 AWG THWN-2 (1) #10 AWG THWN-2 GND IN 3/4" IMC, RMC, FMC, LFMC, PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUN (2) #10 AWG THWN-2 (1) #6 BARE CONDUCTOR GND IN 3/4" IMC, RMC, FMC, LFMC, PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUN UM NG BACKFEED BREAKER 200A MAIN SERVICE PANEL 120/240V 200A 40A INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200A + 40A = 240 A BUSS RATING x 120% 200A x 120% = 240A 06/23/21 ELECTRICAL NOTES 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR 75 DEGREE C. 3. CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.14 4. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 5. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE . 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). E-02 WIRING CALCULATIONS SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.ELECTRICAL CALCULATIONS: 1. BEFORE INVERTER: AMBIENT TEMPERATURE = 32° CONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(c) TEMPERATURE DERATE FACTOR - (0.96) ..............NEC 310.15(B)(2)(a) GROUPING FACTOR - (0.8) .................................NEC 310.15(B)(3)(a) CONDUCTOR AMPACITY = (OPTIMIZER O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B) = [15 x 1.56] / 0.96 / 0.8 = 30.47 A SELECTED CONDUCTOR - #10 THWN-2 ...NEC 310.15(B)(16) 2. AFTER INVERTER: TEMPERATURE DERATE FACTOR - 0.96 GROUPING FACTOR - 1 CONDUCTOR AMPACITY = (TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B) = [(25 x 1.25] / 0.96 / 1] = 32.55 A SELECTED CONDUCTOR - #10THWN-2 ...NEC 310.15(B)(16) 3. PV OVER CURRENT PROTECTION ...NEC 690.9(B) = TOTAL INVERTER O/P CURRENT x 1.25 = (25) x 1.25 = 31.25A SELECTED OCPD = 40 A SELECTED EQUIPMENT GROUNDING CONDUCTOR (EGC) = #10 THWN-2 ...NEC 250.122(A) 06/23/21 E-03 SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.SYSTEM LABELING WARNING ELECTRIC SHOCK HAZARD ! DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.17(E), CB PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED OPERATING AC CURRENT 25 AMPS NOMINAL AC OPERATING VOLTAGE 240 VOLTS LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.54) WARNING LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: NEC690.31(G)(3)(4) & NEC 690.13(G)(4) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(3) & NEC 690.64) ADHESIVE FASTENED SIGNS: · THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. NEC110.21(B)(3) · WHERE REQUIRED ELSEWHERE IN THIS CODE AND FIELD APPLIED LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4. NEC 110.21(B) FIELD MARKING · ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. IFC 605.11.1.3 INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] LABEL LOCATION: AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.56(C)) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! 855-573-2843 EMERGENCY CONTACT WARNING! INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING! DEDICATED SOLAR PANELS DO NOT CONNECT ANY OTHER LOADS Figure 690.56(C)(1)(a) Label for PV Systems that Shut down the array and the conductors leaving the array SHUTDOWN SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN WARNING PHOTOVOLTAIC POWER SOURCE 06/23/21 DS-01 DATASHEET MODULE SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.06/23/21 DS-02 DATASHEET OPTIMIZER SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.06/23/21 DS-03 DATASHEET INVERTER SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.06/23/21 DS-04 DATASHEET ATTACHMENT SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.06/23/21 DS-05 DATASHEET RACKING SHEET NUMBER SHEET NAMEDESCRIPTION REV REVISIONSDATE PERMIT DEVELOPER OSI 08/09/2021 DESIGNER REVIEWER DATE NINA PRICE13150 HAZELWOOD DR, CARMEL,IN 46033, USASignature with Seal ADD : 1821 S. BASCOM AVE, UNIT 191. CAMPBELL, CA 95008, USA LICENSE #1014694 CONTACT: 1-855-573-2843 ENGG.06/23/21