HomeMy WebLinkAboutE111 - Electrical PlanOPEN OFFICE
206
STG
202
CONFERENCE
204
OFFICE
210
OFFICE
208
OFFICE
209
OFFICE
211
CONFERENCE
212
PHONE
216
PHONE
217
PHONE
218
PHONE
219
BREAK
207
FILES
205
OFFICE
213 OFFICE
214WHI
T
E
BOARDWHITEBOA
R
D
HUDDLE
118
ENTRY
201
SERVER
203
PHONE
215
+
4
4
"
+
4
4
"+24"J
J TV+60"
+60"
+
2
4
"GFCI+60"+60"+60"+60"+60"+60"+60"
+60"
TVTV
ELECTRICAL PLAN
E111
PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH
TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS.
PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH
TENANT'S FURNITURE VENDOR.
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANT'S
MICROWAVE, CENTERED AT 24" A.F.F.
PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN.
COORDINATE EXACT LOCATION WITH TENANT.
IF POSSIBLE, CONVERT EXISTING BLANK/OPEN BOX TO NEW RECEPTACLE AS SHOWN. IF NOT POSSIBLE,
REMOVE BLANK/OPEN BOX AND PROVIDE NEW RECEPTACLE AT THIS LOCATION.
PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL AND DATA. COORDINATE
WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL TO
TENANT FOR APPROVAL PRIOR TO ORDERING.
PROVIDE DIRECT HDMI/VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU DEVICE TO WALL
MOUNTED MONITOR.
CONTRACTOR TO CONFIRM IF EXISTING OUTLET IS DEDICATED. IF NOT, ALTER AS REQUIRED.
CONTRACTOR IS TO ENSURE THAT ALL EXISTING OUTLETS IN THIS LOCATION ARE GFCI AND LOWER OUTLETS TO
42" A.F.F. INSTEAD OF 44"
PROVIDE SEPARATE PRICE FOR (4) N57 DUPLEX AT THIS LOCATION. COORDINATE EXACT IT REQUIREMENTS
AND DEVICE LOCATIONS WITH TENANT.
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED.
PROVIDE CEILING MOUNTED DUPLEX AND QUADPLEX AT THIS LOCATION. CONFIRM EXACT LOCATION AND
REQUIREMENTS WITH TENANT AS REQUIRED.
PLAN NOTES
ELECTRICAL PLAN
AREA NOT IN CONTRACT
AREA OF WORK
LEGEND
DESCRIPTIONDATE
ISSUE
04.01.21 REVIEW SET
04.07.21 PERMIT SET
04.08.21 CONSTRUCTION SET
REVISIONS
DESCRIPTIONMARK DATE DB
04.12.21 JR A121 REV
04.26.21 JR A131 REV
05.10.21 JR REVISIONS
2
3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBER
DRAWN BYPROJ. MGR PSI SERVICES11590 MERIDIAN CROSSING | SUITE 220CARMEL, IN 46032JRACM
2020.313
2ND FLOOR
N
1
0 2'4' 8' 16'
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
GENERAL NOTES
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
CEILING MOUNTED
DUPLEX AND QUADPLEX
CEILING MOUNTED
DUPLEX AND QUADPLEX
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
J
+42"
2
06/23/21