HomeMy WebLinkAboutL100 - Life Safety PlanOPEN OFFICE
206
STG
202
93 SF
x
CONFERENCE
204
17'-3"20'-7"
OFFICE
210
146 SF
x
OFFICE
208
8'-7"12'-0"
x
OFFICE
209
8'-7"12'-0"
x
OFFICE
211
10'-7"10'-1"
x
CONFERENCE
212
15'-1"12'-0"
x
PHONE
216
5'-9"6'-3"
x
PHONE
217
5'-6"6'-3"
x
PHONE
218
5'-9"6'-3"
x
PHONE
219
5'-9"6'-3"
x
BREAK
207
14'-2"9'-4"
x
FILES
205
8'-8"9'-4"
x
OFFICE
213
7'-3"12'-0"x
OFFICE
214
10'-5"12'-0"WHIT
E
B
OARD
WHITEBOAR
D
HUDDLE
118
ENTRY
201
SERVER
203
83 SF
PHONE
215
79 SF ELNELNELNFELIFE SAFETY
PLAN
L100LIFE SAFETY PLAN
DESCRIPTIONDATE
ISSUE
04.01.21 REVIEW SET
04.07.21 PERMIT SET
04.08.21 CONSTRUCTION SET
REVISIONS
DESCRIPTIONMARK DATE DB
04.12.21 JR A121 REV
04.26.21 JR A131 REV
05.10.21 JR REVISIONS
2
3
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBER
DRAWN BYPROJ. MGR PSI SERVICES11590 MERIDIAN CROSSING | SUITE 220CARMEL, IN 46032JRACM
2020.313
2ND FLOOR
N
1
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO
AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS
50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE
ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER
REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL
APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE
CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER
HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES
MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE
TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT
THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING
FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10.
COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND
HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A
VISIBLE EXTINGUISHER.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES
UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING
SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN,
INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
LIFE SAFETY NOTES
L1. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS
REQUIRED TO MEET ALL LOCAL AND STATE CODES.
L3.RELOCATE EXISTING SPRINKLER HEADS TO FIT NEW WALL LAYOUT;
PROVIDE NEW AS REQUIRED. SPRINKLERS TO BE LOCATED PER FIRE
PROTECTION CODE.
GENERAL NOTES
0 8'16'4'
EXISTING ELECTRICAL PANEL LOCATION
EXISTING EXIT
EP
EX
LEGEND
FIRE EXTINGUISHER
EXIT SIGN
EMERGENCY LIGHT
FE
- BUILDING STAIR LOCATION
AREA NOT IN CONTRACT
AREA OF WORK
TRAVEL DISTANCE
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT-OUT OFFICE SPACE
TOTAL BUILDING AREA
TOTAL PROJECT AREA
CHANGE OF OCCUPANCY CLASS?
OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD
NO
OCCUPANCY CLASSIFICATION B(USINESS)
GEN. OFFICE SF 100
NUMBER OF EXITS REQUIRED: 1 PROVIDED: 1
SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES 0
TOTAL AREA ON THE FLOOR
SF
SF/FLOOR X STORIES SF
SF
21,167 SF
ACCESSORY AREA EXCEEDS 10% NO
FIRE BARRIERS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
=
TOTAL OCCUPANTS IN PROJECT AREA 39
CODE SUMMARY
PREVIOUS USE OF SPACE B(USINESS)
ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978? NO
3,852
3,852
21,167 6 157,000
39
- LED EDGE LIT
BUILDING CONSTRUCTION TYPE I-B
BUSINESS
TRAVEL DISTANCE = 120'-0"
BUSINESS
BUSINESS
EP
EX
EX
BUSINESSBUSINESS
2
3
06/23/21