HomeMy WebLinkAboutA111 - Architectural Floor PlanWALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT METAL STUD EXISTING WINDOW MULLION EQUAL OPEN OFFICE 206 STG 202 CONFERENCE 204 OFFICE 210 OFFICE 208 OFFICE 209 OFFICE 211 CONFERENCE 212 PHONE 216 PHONE 217 PHONE 218 PHONE 219 BREAK 207 FILES 205 OFFICE 213 OFFICE 214 HUDDLE 118 ENTRY 201 SERVER 203 PHONE 215 9'-11"9'-0"4'-3" 1 3 ' - 3 " 11'-0" 15'-6"1'-1"2' -1 0 "135°135°6'-8"8'-6"5'-1"(CLE AR) 6' - 2 "5'-11" 6'-2" 6'-2" FE21'-9"5'-1" 6'-8" ARCHITECTURAL FLOOR PLAN A111 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW FIRE EXTINGUISHER AND SEMI-RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. SEMI-RECESSED CABINET TO BE PAINTED TO MATCH ADJACENT WALL. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. ANGLE OF NEW WALLS TO FOLLOW ANGLE OF EXISTING ADJACENT WALL. VERIFY EXISTING CONDITIONS IN FIELD. INSTALL RELOCATED SERVER RACK FROM DECONSTRUCTION AT THIS LOCATION. SERVER RACK NOT TO BE WALL MOUNTED. CONFIRM EXACT LOCATION AND REQUIREMENTS WITH TENANT AS REQUIRED. PROVIDE SEPARATE PRICE FOR 24" DEEP X 2" THICK PLASTIC LAMINATE COUNTERTOP AT 30" A.F.F. AT THIS LOCATION. SUPPORT COUNTER AS REQUIRED WITH RAKKS EH-1818-FM FLUSH MOUNTED SUPPORT BRACKETS ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. COUNTERTOP TO SPAN ENTIRE WALL LENGTH; VERIFY ALL CONDITIONS IN FIELD. _______________________________________________________________ REUSE EXISTING PLUMBING IF POSSIBLE OR PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AS REQUIRED. PROVIDE WATER LINE FOR COFFEE AND WATER COOLER. CONFIRM LOCATION WITH TENANT. PLAN NOTES ARCHITECTURAL PLANAREA NOT IN CONTRACT AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL W1 WALL WITH INSULATION 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. TYP. A111 1 DESCRIPTIONDATE ISSUE 04.01.21 REVIEW SET 04.07.21 PERMIT SET 04.08.21 CONSTRUCTION SET REVISIONS DESCRIPTIONMARK DATE DB 04.12.21 JR A121 REV 04.26.21 JR A131 REV 05.10.21 JR REVISIONS 2 3 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBER DRAWN BYPROJ. MGR PSI SERVICES11590 MERIDIAN CROSSING | SUITE 220CARMEL, IN 46032JRACM 2020.313 2ND FLOOR N 1 0 2'4' 8' 16' 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. GENERAL NOTES NOT TO SCALE WALL AT MULLION DETAIL A111 1 W? A211 2 2 3 06/23/21