HomeMy WebLinkAboutA121 - Reflected Ceiling PlanELNELNELNSNSNSNSNS N SN SNSNSN SNSN SN SN SNSNS N SNSNREFLECTED CEILING PLAN A121 PROVIDE ADDITIONAL COOLING UNIT IN TENANT'S SERVER ROOM. COORDINATE WITH TENANT AND BUILDING MANAGEMENT AS REQUIRED. CONTROL ENTRY 201, OPEN OFFICE 206 AND HUDDLE 218 LIGHTING WITH SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. PROVIDE NEW CEILING GRID AND TILE AS SHOWN TO MATCH AND ALIGN WITH EXISTING SUCH THAT NEW AND EXISTING CEILINGS APPEAR CONTINUOUS. EXHAUST FAN TO BE CONTROLLED BY THERMOSTAT. COORDINATE WITH TENANT ON EXACT REQUIREMENTS. PLAN NOTES LIGHT SWITCH, 3-WAY LIGHT SWITCHN N3 3 EXIT LIGHT FIXTURE LIGHT FIXTURE, 2'x2', LED, BUILDING STANDARD LIGHT FIXTURE, 2'x4', LED, BUILDING STANDARD RELOCATED DIFFUSER, LAY-IN, 4"x 2' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x4' NEW OR RELOCATED EXISTING TO REMAIN EXIT LIGHT FIXTURE LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x4' DIFFUSER, LAY-IN, 4"x 2' DIFFUSER, LAY-IN, 2'x2' LIGHT FIXTURE, 2'x2', FLUORESCENT, PRISMATIC LIGHT FIXTURE, 2'x4', FLUORESCENT, PRISMATIC LEGEND REFLECTED CEILING PLANAREA NOT IN CONTRACT AREA OF WORK DESCRIPTIONDATE ISSUE 04.01.21 REVIEW SET 04.07.21 PERMIT SET 04.08.21 CONSTRUCTION SET REVISIONS DESCRIPTIONMARK DATE DB 04.12.21 JR A121 REV 04.26.21 JR A131 REV 05.10.21 JR REVISIONS 2 3 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700PROJECT NUMBER DRAWN BYPROJ. MGR PSI SERVICES11590 MERIDIAN CROSSING | SUITE 220CARMEL, IN 46032JRACM 2020.313 2ND FLOOR N 1 0 2'4' 8' 16' EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE MECHANICAL DIFFUSER RELOCATION A121 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV / HEAT PUMP EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2' A121 1 1. REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x4 AT 8'-3" A.F.F. REPAIR ANY DAMAGED GRID TO MATCH EXISTING. BASE BID: PROVIDE NEW CEILING TILE UP TO $3,000 ALLOWANCE. PROVIDE SEPARATE PRICE FOR NEW, ARMSTRONG DUNE REVEAL EDGE CEILING TILE THROUGHOUT. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.¬ ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.¬NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED.¬ ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED;¬ MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES 1 3 06/23/21