HomeMy WebLinkAboutS100.0EXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
ND022840
5068
3068 D01D01
W01
W02
W03
W033468D04
D03
6082
UP
DN
UP
cL cL
cL
cL
cL
R4
R4
R4 R4
R4
R4
R4R4
R4
R4
R4
R4R4
R4
R4
R4
R4
R4
R4R4 R4
SA
5'-5 3/4"
3'-8"3'-6 1/2"3'-8"7'-6" 16'-7" 1'-2 1/2"21'-3 1/2"25'-10 1/2"18'-7 1/2"5' 21'-5"
6' 6'1'-6"5' 2'-6" 5'-6"29'-11 1/2"
8'-9 3/4" 14'-1"4'-6 1/2" 15'-8"3'-3"26'-5 1/2"
13'-3"8'-1 1/2"2'-5"
2' 15'-3 1/2"22'
GARAGE
C.H. 10'-0" AFF
CONCRETE WITH EPOXY FINISH
EXERCISE ROOM
C.H. 10'-0" AFF
RUBBER FLOORING
HALL
C.H. 10'-0" AFF
CARPET
TV
CC1CC1
CC2CC2
DN
DROPPED STEEL BEAM
SECOND STORY OVER
HANGS FIRST FLOOR BY 18"
SECOND STORY OVER
HANGS FIRST FLOOR BY 18"
F5F5
F6F6
FRAMING PLAN NOTES
NOTE QTY DESCRIPTION
1 FRAME NEW EXTERIOR WALLS AND OPENINGS. INSTALL
EXTERIOR SHEATHING.
1 FRAME NEW NON-LOAD BEARING INTERIOR WALLS
AS SHOWN ON PLAN.
1 FRAME NEW FLOOR SYSTEM AND SUBFLOOR
1 FRAMERS TO INSTALL WINDOWS AND EXTERIOR DOORS.
1 FRAME EXTRA BLOCKING FOR BALLET BAR
1 FRAME 12" TALL SOFFIT TO ALLOW FOR HVAC DUCTS
F1F1
F2F2
F3F3
F4F4
F5F5
F6F6
F1F1
F2F2
F3F3
F4F4
F5F5
F6F6
INSULATION PLAN NOTES
NOTE QTY DESCRIPTION
1 FOAM AND FIRE CAULK ALL NEW WALLS TO MEET
MUNICIPAL FIRE CODE REQUIREMENTS.
1 INSULATE NEW EXTERIOR WALLS, ROOF AND ATTIC PER
CODE.
I1I1
I2I2
I1I1
I2I2
DRYWALL PLAN NOTES
NOTE QTY DESCRIPTION
1 INSTALL DRYWALL ON NEW FRAMED WALLS AND CEILINGS.
LEVEL 4 FINISH THROUGHOUTD1D1D1D1
CONCTRETE FLATWORK PLAN NOTES
NOTE QTY DESCRIPTION
1 CONCRETE STEPS TO GRADE. VERIFY EXACT STYLE AND
SIZE ON SITE WITH HOMEOWNER.
1 NEW FLATWORK TO MATCH AND ALIGN WITH EXISTING
DRIVEWAY.
CC1CC1
CC2CC2
CC1CC1
CC2CC2
DOOR SCHEDULE
NUMBER FLOOR QTY R/O TOP WIDTH HEIGHT DESCRIPTION SUPPLIER
D01 1 2 98"X99" 96" 96 " 96 " GARAGE-GARAGE DOOR CHD11
D02 1 1 36"X82 1/2" 81 1/4" 34 " 80 " EXT. HINGED-DOOR E17.2
D03 1 1 38"X83" 80" 36 " 80 "20 MIN FIRE RATED DOOR PER
SELECTIONS
D04 1 1 32"X82 1/2" 80" 30 " 80 " HINGED-DOOR P04
WINDOW SCHEDULE
NUMBER FLOOR QTY R/O BOTTOM TOP WIDTH HEIGHT EGRESS TEMPERED DESCRIPTION SUPPLIER
W01 1 1 53"X61" 34" 94" 52 " 60 " MULLED UNIT
W02 1 1 92"X62" 24" 85" 91 " 61 " MULLED UNIT
W03 1 2 27"X60" 38" 97" 26 " 59 " FIXED GLASS
TT4" CONCRETE SLAB (EPOXY FINISH)
INTERIOR TRIM
1/2" DRYWALL
2X4 EXTERIOR STUDS @ 16" O.C.
R-15 FIBERGLASS BATT INSULATION
2X4 PRESSURE TREATED BOTTOM PLATE
8X16 CONTINUOUS FOOTER
PERIMETER DRAIN
BRICK LEDGE
8" CMU FOUNDATION WALL
#4 REBAR SPACED 24" O.C.
4" CMU TOP COURSE
CAST IN PLACE ANCHOR BOLT
PAINTED BRICK EXTERIOR FINISH
WEEP HOLES @ 33" O.C.
1/2" AIR GAP
TYVEK VAPOR BARRIER
3/4" OSB SHEATING
FLASHING
1X8 CEDAR
GUTTER
VENTED SOFFIT
1X4 CEDAR
STUCCATO BOARD
SYNTHETIC FELT UNDERLAYMENT
ASPHALT SHINGLES
3/4" DECKING
FLASHING
10
12
INTERIOR TRIM
1/2" DRYWALL
2X4 STUDS @ 16" O.C.
3/4" OSB SUBFLOOR
R-15 FIBERGLASS BATT
FINISHED FLOOR
DOUBLE TOP PLATE
1/2" DRYWALL
DOUBLE TOP PLATE
5/8" DRYWALL
4" GRAVEL BASE
R-10 RIGID INSULATION BOARD
14" I JOISTS@ 16" O.C.
10'
CANTILEVERED 2ND
FLOOR FRAMING
SCISSOR TRUSSROOF FRAMING
6' - 6"
VAULTED CEILING
5
12 ALDEN RESIDENCENew Carriage House1801 Milford StCarmel, IN 46032Date:Revision:
A4
SHEET OF 14
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462205/10/2021
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
GENERAL PROPOSED PLAN NOTES
Framing contractors are responsible for all labor,
for the scope of work specified on the drawings
provided by Custom Living.
Owner understands that Custom Living has only
provided a labor and material allowance for the
scope of Rough Carpentry work specified on the
drawings. Any additional work added or
uncovered during this scope will be filed as a
Change Orde r during construction
Owner understands that the drywall allowance is
based on an estimated board count and square
footage take-off. A final walk through with a
drywall contractor after framing and mechanical
rough-ins will be necessary to finalize drywall
installation and finish budgets.
Final drywall touch-ups will follow countertop
installation.
PROPOSED FIRST FLOOR PLAN
SCALE: 3/8" = 1'
WALL SECTION DETAIL