HomeMy WebLinkAboutS100.0EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING ND022840 5068 3068 D01D01 W01 W02 W03 W033468D04 D03 6082 UP DN UP cL cL cL cL cL R4 R4 R4 R4 R4 R4 R4R4 R4 R4 R4 R4R4 R4 R4 R4 R4 R4 R4R4 R4 SA 5'-5 3/4" 3'-8"3'-6 1/2"3'-8"7'-6" 16'-7" 1'-2 1/2"21'-3 1/2"25'-10 1/2"18'-7 1/2"5' 21'-5" 6' 6'1'-6"5' 2'-6" 5'-6"29'-11 1/2" 8'-9 3/4" 14'-1"4'-6 1/2" 15'-8"3'-3"26'-5 1/2" 13'-3"8'-1 1/2"2'-5" 2' 15'-3 1/2"22' GARAGE C.H. 10'-0" AFF CONCRETE WITH EPOXY FINISH EXERCISE ROOM C.H. 10'-0" AFF RUBBER FLOORING HALL C.H. 10'-0" AFF CARPET TV CC1CC1 CC2CC2 DN DROPPED STEEL BEAM SECOND STORY OVER HANGS FIRST FLOOR BY 18" SECOND STORY OVER HANGS FIRST FLOOR BY 18" F5F5 F6F6 FRAMING PLAN NOTES NOTE QTY DESCRIPTION 1 FRAME NEW EXTERIOR WALLS AND OPENINGS. INSTALL EXTERIOR SHEATHING. 1 FRAME NEW NON-LOAD BEARING INTERIOR WALLS AS SHOWN ON PLAN. 1 FRAME NEW FLOOR SYSTEM AND SUBFLOOR 1 FRAMERS TO INSTALL WINDOWS AND EXTERIOR DOORS. 1 FRAME EXTRA BLOCKING FOR BALLET BAR 1 FRAME 12" TALL SOFFIT TO ALLOW FOR HVAC DUCTS F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 F1F1 F2F2 F3F3 F4F4 F5F5 F6F6 INSULATION PLAN NOTES NOTE QTY DESCRIPTION 1 FOAM AND FIRE CAULK ALL NEW WALLS TO MEET MUNICIPAL FIRE CODE REQUIREMENTS. 1 INSULATE NEW EXTERIOR WALLS, ROOF AND ATTIC PER CODE. I1I1 I2I2 I1I1 I2I2 DRYWALL PLAN NOTES NOTE QTY DESCRIPTION 1 INSTALL DRYWALL ON NEW FRAMED WALLS AND CEILINGS. LEVEL 4 FINISH THROUGHOUTD1D1D1D1 CONCTRETE FLATWORK PLAN NOTES NOTE QTY DESCRIPTION 1 CONCRETE STEPS TO GRADE. VERIFY EXACT STYLE AND SIZE ON SITE WITH HOMEOWNER. 1 NEW FLATWORK TO MATCH AND ALIGN WITH EXISTING DRIVEWAY. CC1CC1 CC2CC2 CC1CC1 CC2CC2 DOOR SCHEDULE NUMBER FLOOR QTY R/O TOP WIDTH HEIGHT DESCRIPTION SUPPLIER D01 1 2 98"X99" 96" 96 " 96 " GARAGE-GARAGE DOOR CHD11 D02 1 1 36"X82 1/2" 81 1/4" 34 " 80 " EXT. HINGED-DOOR E17.2 D03 1 1 38"X83" 80" 36 " 80 "20 MIN FIRE RATED DOOR PER SELECTIONS D04 1 1 32"X82 1/2" 80" 30 " 80 " HINGED-DOOR P04 WINDOW SCHEDULE NUMBER FLOOR QTY R/O BOTTOM TOP WIDTH HEIGHT EGRESS TEMPERED DESCRIPTION SUPPLIER W01 1 1 53"X61" 34" 94" 52 " 60 " MULLED UNIT W02 1 1 92"X62" 24" 85" 91 " 61 " MULLED UNIT W03 1 2 27"X60" 38" 97" 26 " 59 " FIXED GLASS TT4" CONCRETE SLAB (EPOXY FINISH) INTERIOR TRIM 1/2" DRYWALL 2X4 EXTERIOR STUDS @ 16" O.C. R-15 FIBERGLASS BATT INSULATION 2X4 PRESSURE TREATED BOTTOM PLATE 8X16 CONTINUOUS FOOTER PERIMETER DRAIN BRICK LEDGE 8" CMU FOUNDATION WALL #4 REBAR SPACED 24" O.C. 4" CMU TOP COURSE CAST IN PLACE ANCHOR BOLT PAINTED BRICK EXTERIOR FINISH WEEP HOLES @ 33" O.C. 1/2" AIR GAP TYVEK VAPOR BARRIER 3/4" OSB SHEATING FLASHING 1X8 CEDAR GUTTER VENTED SOFFIT 1X4 CEDAR STUCCATO BOARD SYNTHETIC FELT UNDERLAYMENT ASPHALT SHINGLES 3/4" DECKING FLASHING 10 12 INTERIOR TRIM 1/2" DRYWALL 2X4 STUDS @ 16" O.C. 3/4" OSB SUBFLOOR R-15 FIBERGLASS BATT FINISHED FLOOR DOUBLE TOP PLATE 1/2" DRYWALL DOUBLE TOP PLATE 5/8" DRYWALL 4" GRAVEL BASE R-10 RIGID INSULATION BOARD 14" I JOISTS@ 16" O.C. 10' CANTILEVERED 2ND FLOOR FRAMING SCISSOR TRUSSROOF FRAMING 6' - 6" VAULTED CEILING 5 12 ALDEN RESIDENCENew Carriage House1801 Milford StCarmel, IN 46032Date:Revision: A4 SHEET OF 14 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462205/10/2021 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specified on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be filed as a Change Orde r during construction Owner understands that the drywall allowance is based on an estimated board count and square footage take-off. A final walk through with a drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall installation and finish budgets. Final drywall touch-ups will follow countertop installation. PROPOSED FIRST FLOOR PLAN SCALE: 3/8" = 1' WALL SECTION DETAIL SCALE: 5/16" = 1' 0"DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-307306/25/21