Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S200.0
NDN SB423DB18SB363DB283DB223DB28SB423DB18 SB363DB28 3DB223DB28D02 W03W02 W03 W01 W01 W01 D01D01 CD CW R4 R4 R4R4 3 R4 R4 R4 R4R4 R4 R4 R4 R4 R4 R4 R4 R4 R4R4 R4 R4 R4 3DM 3DM 3 3 3DM 3DM SD SD 27'-7"15'-1 1/2" 5'-2" 16'-2 1/2"9'-1 1/2" 5'-6 1/2"14'-7"43'-7" OUTSIDE FRAME TO OUTSIDE FRAME22' 18'-3 1/2"2'-6" 4'-8"12'-9"6'-4" 13'-3" 26'-5 1/2"5'-8"1'-9"3'-4" 3'-4"1'-6" 11'-0 1/2"4'-6 1/2"3'-6" 7'-2" 4'-1" BATH BEDROOM CLOSET STACKED W/D direct vent firebox faux ridge beamFIRST FLOOR LINE FIRST FLOOR LINE FIRST FLOOR LINE 6'-6" KNEE WALLKNEE WALLSLOPED CLGSLOPED CLG slatted wood featureDOOR SCHEDULE NUMBER FLOOR QTY R/O TOP WIDTH HEIGHT DESCRIPTION SUPPLIER D01 2 2 32"X82 1/2" 80" 30 " 80 " HINGED-DOOR P04 D02 2 1 50"X82 1/2" 80" 48 " 80 " DOUBLE HINGED-DOOR P04 WINDOW SCHEDULE NUMBER FLOOR QTY R/O BOTTOM TOP WIDTH HEIGHT EGRESS TEMPERED DESCRIPTION SUPPLIER W01 2 3 31"X81" 12" 92" 30 " 80 " FIXED GLASS FRANKLIN W02 2 1 31"X61" 13" 73" 30 " 60 " FIXED GLASS W03 2 2 31"X61" 13" 73" 30 " 60 " YES FIXED GLASS TT4" CONCRETE SLAB (EPOXY FINISH) INTERIOR TRIM 1/2" DRYWALL 2X4 EXTERIOR STUDS @ 16" O.C. R-15 FIBERGLASS BATT INSULATION 2X4 PRESSURE TREATED BOTTOM PLATE 8X16 CONTINUOUS FOOTER PERIMETER DRAIN BRICK LEDGE 8" CMU FOUNDATION WALL #4 REBAR SPACED 24" O.C. 4" CMU TOP COURSE CAST IN PLACE ANCHOR BOLT PAINTED BRICK EXTERIOR FINISH WEEP HOLES @ 33" O.C. 1/2" AIR GAP TYVEK VAPOR BARRIER 3/4" OSB SHEATING FLASHING 1X8 CEDAR GUTTER VENTED SOFFIT 1X4 CEDAR STUCCATO BOARD SYNTHETIC FELT UNDERLAYMENT ASPHALT SHINGLES 3/4" DECKING FLASHING 10 12 INTERIOR TRIM 1/2" DRYWALL 2X4 STUDS @ 16" O.C. 3/4" OSB SUBFLOOR R-15 FIBERGLASS BATT FINISHED FLOOR DOUBLE TOP PLATE 1/2" DRYWALL DOUBLE TOP PLATE 5/8" DRYWALL 4" GRAVEL BASE R-10 RIGID INSULATION BOARD 14" I JOISTS@ 16" O.C. 10' CANTILEVERED 2ND FLOOR FRAMING SCISSOR TRUSSROOF FRAMING 6' - 6" VAULTED CEILING 5 12 FRAMING PLAN NOTES NOTE QTY DESCRIPTION 1 FRAME NEW EXTERIOR WALLS AND OPENINGS. INSTALL EXTERIOR SHEATHING. 1 FRAME NEW FLOOR SYSTEM AND SUBFLOOR 1 FRAME NEW NON-LOAD BEARING INTERIOR WALLS AS SHOWN ON PLAN. 1 FRAMERS TO INSTALL WINDOWS F1F1 F2F2 F3F3 F4F4 F1F1 F2F2 F3F3 F4F4 INSULATION PLAN NOTES NOTE QTY DESCRIPTION 1 FOAM AND FIRE CAULK ALL NEW WALLS TO MEET MUNICIPAL FIRE CODE REQUIREMENTS. 1 INSULATE NEW EXTERIOR WALLS, ROOF AND ATTIC PER CODE. I1I1 I2I2 I1I1 I2I2 DRYWALL PLAN NOTES NOTE QTY DESCRIPTION 1 INSTALL DRYWALL ON NEW FRAMED WALLS AND CEILINGS. LEVEL 4 FINISH THROUGHOUTD1D1D1D1 ALDEN RESIDENCENew Carriage House1801 Milford StCarmel, IN 46032Date:Revision: A5 SHEET OF 14 SIGNATURE / SEAL Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462205/10/2021 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ]DESIGNER: JONNI BERKLEYE: jonni@customlivingusa.comC: 317-801-3073PROPOSED SECOND FLOOR PLAN SCALE: 1/2" = 1' WALL SECTION DETAIL SCALE: 5/16" = 1' 0" 06/25/21