Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
125 Bear Creek - Seals
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). April 16,2021 Johnson, Andrew Pages or sheets covered by this seal: I45689436 thru I45689481 My license renewal date for the state of Indiana is July 31, 2022. 125_Bear_Creek 125 Bear Creek IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss GE01 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689436 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:17 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-U0QNTbODs2ng9oKuT6apkL6ND5leDzskmnKLsPzQOsO Scale = 1:34.4 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 3x4 3x6 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 10-2-010-2-0 -1-0-0 1-0-0 5-1-0 5-1-0 10-2-0 5-1-0 11-2-0 1-0-0 1-3-05-5-131-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.04 0.12 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 112 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 10-2-0. (lb) - Max Horz 16=-102(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Corner(3R) 2-0-0 to 8-2-0, Corner(3E) 8-2-0 to 11-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15, 12, 11. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss GE02 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689437 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:19 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-QPY7tHQTOf1OP6UHaXcHpmBjTvQzhsV1D5pSxIzQOsM Scale = 1:87.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 3x6 3x6 3x6 3x12 3x6 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 3x12 5x6 37-11-037-11-0 -0-11-0 0-11-0 16-4-8 16-4-8 21-6-8 5-2-0 37-11-0 16-4-8 38-10-0 0-11-0 1-1-012-0-01-1-012-0-08.00 12 Plate Offsets (X,Y)-- [3:0-2-8,0-2-4], [12:0-3-12,0-2-0], [15:0-4-4,0-2-4], [25:0-8-13,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.07 0.04 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.01 (loc) 25 25 25 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 782 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 15-35,14-36,13-37,11-38,16-34: 2x4 SPF No.2 SLIDER Left 2x8 SP 2400F 2.0E - 1-11-11, Right 2x8 SP 2400F 2.0E -t 1-10-8 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 12-15. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-35, 14-36, 13-37, 11-38, 10-40, 9-41, 16-34, 17-32 REACTIONS.All bearings 37-11-0. (lb) - Max Horz 2=-181(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 36, 40, 41, 42, 43, 44, 45, 34, 32, 31, 30, 29, 28, 27 except 46=-102(LC 10) Max Grav All reactions 250 lb or less at joint(s) 2, 35, 36, 37, 38, 40, 41, 42, 43, 44, 45, 46, 34, 32, 31, 30, 29, 28, 27, 25 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 13-4-8, Corner(3R) 13-4-8 to 24-6-8, Exterior(2N) 24-6-8 to 35-6-8, Corner(3E) 35-6-8 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 36, 40, 41, 42, 43, 44, 45, 34, 32, 31, 30, 29, 28, 27 except (jt=lb) 46=102. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss GE03 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689438 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:21 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-MnftIzSkvHH5eQegiyfluBH3Yj6T9m?KhPIZ?AzQOsK Scale = 1:86.1 Sheet Back Full Sheathing 1 Ply 7/16OSB8 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 3x6 3x6 3x6 2x4 2x4 3x12 3x6 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 37-7-837-7-8 -0-11-0 0-11-0 16-4-8 16-4-8 21-6-8 5-2-0 37-7-8 16-1-0 1-1-012-0-01-3-512-0-08.00 12 Plate Offsets (X,Y)-- [3:0-2-8,0-2-4], [12:0-4-8,0-2-8], [15:0-4-4,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.09 0.04 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 1 1 25 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 775 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 15-34,14-35,13-36,11-37,16-33: 2x4 SPF No.2 SLIDER Left 2x8 SP 2400F 2.0E -t 1-11-11 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 12-15. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-34, 14-35, 13-36, 11-37, 10-39, 9-40, 16-33, 17-31 REACTIONS.All bearings 37-7-8. (lb) - Max Horz 2=188(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 35, 36, 39, 40, 41, 42, 43, 44, 45, 33, 31, 30, 29, 28, 27, 26 except 2=-138(LC 6) Max Grav All reactions 250 lb or less at joint(s) 25, 2, 34, 35, 36, 37, 39, 40, 41, 42, 43, 44, 45, 33, 31, 30, 29, 28, 27, 26 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-251/233 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 13-4-8, Corner(3R) 13-4-8 to 24-6-8, Exterior(2N) 24-6-8 to 34-6-4, Corner(3E) 34-6-4 to 37-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 35, 36, 39, 40, 41, 42, 43, 44, 45, 33, 31, 30, 29, 28, 27, 26 except (jt=lb) 2=138. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss GE04 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689439 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:22 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-qzDFWJSMgaPyGZDsGgA_ROpF26S_uF8Tv316XdzQOsJ Scale = 1:35.0 Sheet FrontFull Sheathing1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 4x6 3x12 5x6 3x12 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-11-011-11-0 -0-11-0 0-11-0 5-11-8 5-11-8 11-11-0 5-11-8 12-10-0 0-11-0 1-2-05-7-101-2-09.00 12 Plate Offsets (X,Y)-- [2:0-9-10,Edge], [10:0-9-10,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.04 0.02 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 10 10 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 140 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 SLIDER Left 2x8 SP 2400F 2.0E -t 2-0-0, Right 2x8 SP 2400F 2.0E -t 2-0-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-11-0. (lb) - Max Horz 2=-82(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 15, 16, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 10, 14, 15, 16, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 1-11-8, Exterior(2N) 1-11-8 to 2-11-8, Corner(3R) 2-11-8 to 8-11-8, Exterior(2N) 8-11-8 to 9-10-0, Corner(3E) 9-10-0 to 12-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 15, 16, 13, 12. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss GE05 Truss Type Monopitch Supported Gable Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689440 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:22 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-qzDFWJSMgaPyGZDsGgA_ROpCL6QwuF_Tv316XdzQOsJ Scale = 1:13.3 1 2 3 5 4 3x6 3x4 2x4 -1-0-0 1-0-0 4-9-8 4-9-8 0-8-82-1-43.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.22 0.16 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.01 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=4-9-8, 4=4-9-8 Max Horz 5=49(LC 7) Max Uplift 5=-23(LC 6), 4=-3(LC 10) Max Grav 5=259(LC 1), 4=173(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss GE06 Truss Type Common Supported Gable Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689441 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:24 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:cn4lKQ4upiBY_35AIrwXBvzbzqY-nML0x_UcCCggVtNFN5CSWpvbPw7MM91mNNWDcVzQOsH Scale = 1:30.1 1 2 3 4 5 6 7 8 9 10 11 12 13 21 20 19 18 17 16 15 14 22 23 4x6 3x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 3x4 16-9-016-9-0 -1-0-0 1-0-0 8-4-8 8-4-8 16-9-0 8-4-8 17-9-0 1-0-0 0-9-03-6-80-9-04.00 12 Plate Offsets (X,Y)-- [2:0-4-5,0-0-5], [12:0-4-5,0-0-5] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.05 0.03 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 12 12 12 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 55 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 SLIDER Left 2x4 SPF-S Stud -t 1-6-14, Right 2x4 SPF-S Stud -t 1-6-14 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-9-0. (lb) - Max Horz 2=33(LC 10) Max Uplift All uplift 100 lb or less at joint(s) 2, 19, 20, 21, 16, 15, 14, 12 Max Grav All reactions 250 lb or less at joint(s) 2, 17, 19, 20, 21, 16, 15, 14, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 5-4-8, Corner(3R) 5-4-8 to 11-4-8, Exterior(2N) 11-4-8 to 14-9-0, Corner(3E) 14-9-0 to 17-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 19, 20, 21, 16, 15, 14, 12. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss GE07 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689442 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:25 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-FYvO8KVEzVoX71xRxojh31RlJKTL5ZFvc1Gm8yzQOsG Scale = 1:44.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 3x4 3x6 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-6-013-6-0 -1-0-0 1-0-0 6-9-0 6-9-0 13-6-0 6-9-0 14-6-0 1-0-0 1-3-06-10-81-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.05 0.22 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 170 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-6-0. (lb) - Max Horz 20=-123(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 12, 17, 18, 15, 14, 13 except 20=-117(LC 6), 19=-109(LC 7) Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 3-9-0, Corner(3R) 3-9-0 to 9-9-0, Exterior(2N) 9-9-0 to 11-6-0, Corner(3E) 11-6-0 to 14-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 17, 18, 15, 14, 13 except (jt=lb) 20=117, 19=109. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss J01 Truss Type Jack-Open Qty 15 Ply 1 125 Bear Creek Job Reference (optional) I45689443 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:26 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-jlTmLgVskpwOkBWdVVEwbE_w8kpkq3z3qh?KgOzQOsF Scale = 1:11.7 1 2 5 3 4 2x4 2x4 1-0-01-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 1-1-01-9-00-5-31-3-131-9-08.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.10 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=26(LC 7) Max Uplift 3=-11(LC 10), 4=-6(LC 10) Max Grav 5=143(LC 1), 3=4(LC 6), 4=16(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss M01 Truss Type Monopitch Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689444 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:26 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-jlTmLgVskpwOkBWdVVEwbE_wbkpeq3z3qh?KgOzQOsF Scale = 1:10.4 1 2 3 5 4 2x4 3x6 2x4 2-10-02-10-0 -1-0-0 1-0-0 2-10-0 2-10-0 0-8-61-6-41-2-120-3-81-6-43.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.07 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=33(LC 7) Max Uplift 5=-26(LC 6), 4=-1(LC 10) Max Grav 5=186(LC 1), 4=86(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss M02 Truss Type Monopitch Qty 4 Ply 1 125 Bear Creek Job Reference (optional) I45689445 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:27 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-Bx18Z0WUV72FML5p2Dl98SW3M77FZWDC3LltDqzQOsE Scale = 1:13.3 1 2 3 5 4 3x4 3x6 3x4 4-9-84-9-8 -1-0-0 1-0-0 4-9-8 4-9-8 0-8-82-1-41-9-120-3-82-1-43.50 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=48(LC 7) Max Uplift 5=-23(LC 6), 4=-3(LC 10) Max Grav 5=258(LC 1), 4=171(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689446 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:27 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-Bx18Z0WUV72FML5p2Dl98SW1a764ZWDC3LltDqzQOsE Scale = 1:13.3 1 2 3 2x4 3x4 3x8 2x4 4-9-84-9-8 4-9-8 4-9-8 0-8-82-1-41-7-120-5-82-1-43.50 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.38 0.22 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 1-3 1-3 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=0-1-8 Max Horz 1=44(LC 7) Max Uplift 3=-4(LC 10) Max Grav 1=180(LC 1), 3=180(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). THIS IS WHAT THEY WANTI DONT NORMALLY PUT THE NOTE IF THEY ARENT MULTIPLYPUT IT IF YOU WANT April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss MG02 Truss Type Monopitch Girder Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689447 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:28 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-f7aXmMX7GQA6_Ug0cwHOgf3EiXTOIzTMI?URlGzQOsD Scale = 1:11.9 1 2 3 3x4 2x4 2x4 3-10-03-10-0 3-10-0 3-10-0 0-8-61-9-121-4-40-5-81-9-123.50 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.22 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 1-3 1-3 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=0-1-8 Max Horz 1=36(LC 7) Max Uplift 3=-4(LC 10) Max Grav 1=142(LC 1), 3=142(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss PB01 Truss Type GABLE Qty 26 Ply 1 125 Bear Creek Job Reference (optional) I45689448 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:29 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-7K8v_iYl1kIzbeFCAeodDtcRExpx1QjVWfE_HjzQOsC Scale = 1:13.1 2 3 4 1 5 3x4 2x4 2x4 5-2-05-2-0 2-7-0 2-7-0 5-2-0 2-7-0 -0-0-41-8-71-8-110-1-00-1-88.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-2-0. (lb) - Max Horz 1=23(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 2, 4 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss PB02 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689449 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:30 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-bWiHB2ZNo2QqDoqOkLJsm48c4LBtmtRelJzXp9zQOsB Scale = 1:23.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 3 4 5 6 10 9 8 1 11 12 7 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 8-7-68-7-6 4-3-11 4-3-11 8-7-6 4-3-11 3-7-10-1-40-1-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 54 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-7-6. (lb) - Max Horz 1=-52(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 2, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6, 9, 10, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-2-14 to 3-2-14, Corner(3R) 3-2-14 to 5-4-8, Corner(3E) 5-4-8 to 8-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 2, 10, 8. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss PB03 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689450 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:31 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-4iGfPOZ?ZLYhryPbH3q5IIhkSlVmVKio_zj5MbzQOsA Scale = 1:23.7 2 3 4 6 1 7 8 5 4x6 3x6 3x6 2x4 8-7-68-7-6 4-3-11 4-3-11 8-7-6 4-3-11 3-7-10-1-40-1-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.19 0.11 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-7-6. (lb) - Max Horz 1=-52(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 1=-252(LC 17), 5=-226(LC 18), 2=-152(LC 10), 4=-134(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 2=450(LC 17), 4=441(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-2-14 to 3-2-14, Corner(3R) 3-2-14 to 5-4-8, Corner(3E) 5-4-8 to 8-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 252 lb uplift at joint 1, 226 lb uplift at joint 5, 152 lb uplift at joint 2 and 134 lb uplift at joint 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss PBE01 Truss Type GABLE Qty 2 Ply 1 125 Bear Creek Job Reference (optional) I45689451 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:32 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-Yvq1cjadKfgYS6_nrmLKrVEyU8qdEmSxDdSeu2zQOs9 Scale = 1:13.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 3 4 1 5 3x4 2x4 2x4 5-2-05-2-0 2-7-0 2-7-0 5-2-0 2-7-0 -0-0-41-8-71-8-110-1-00-1-88.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-2-0. (lb) - Max Horz 1=23(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 2, 4 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T01 Truss Type Common Qty 4 Ply 1 125 Bear Creek Job Reference (optional) I45689452 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:33 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-05OQp3bF5zoO4GZzPUsZNjm_kY3Gz0W5RHCCQUzQOs8 Scale = 1:59.9 1 2 3 4 5 6 7 11 10 9 8 12 13 14 15 16 17 4x6 3x16 MT18HS 3x8 3x4 3x4 3x6 6x6 6x6 3x6 10-5-810-5-8 20-11-010-5-8 -1-0-0 1-0-0 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 20-11-0 5-4-0 21-11-0 1-0-0 1-3-09-11-91-3-010.00 12 Plate Offsets (X,Y)-- [8:0-2-12,0-3-0], [11:0-2-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.59 0.62 0.84 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.29 -0.50 0.02 (loc) 9-11 9-11 8 l/defl >854 >498 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 91 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 8-10: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)11=0-3-8, 8=0-3-8 Max Horz 11=-171(LC 8) Max Grav 11=989(LC 17), 8=989(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-412/70, 3-4=-817/54, 4-5=-817/54, 5-6=-414/69, 2-11=-414/68, 6-8=-415/67 BOT CHORD 9-11=-9/745, 8-9=0/673 WEBS 4-9=0/669, 3-11=-645/0, 5-8=-643/0 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 18-11-0, Exterior(2E) 18-11-0 to 21-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T02 Truss Type Common Qty 2 Ply 1 125 Bear Creek Job Reference (optional) I45689453 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:34 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-UHyo1PctrGwFiP7AzBNowwJ7eyLfiX4EgxxlywzQOs7 Scale: 3/16"=1' 1 2 3 4 5 9 8 7 6 10 11 12 13 3x8 MT18HS 3x4 6x18 MT18HS 3x6 6x6 2x4 3x8 6x6 10-5-810-5-8 18-6-08-0-8 -1-0-0 1-0-0 5-4-0 5-4-0 10-5-8 5-1-8 18-6-0 8-0-8 1-3-09-11-93-3-310.00 12 Plate Offsets (X,Y)-- [5:Edge,0-1-12], [9:Edge,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.71 0.86 0.63 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.41 -0.67 0.01 (loc) 7-9 7-9 6 l/defl >539 >325 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 87 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x6 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-9: 2x4 SPF-S Stud, 5-6: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 9-7-6 oc bracing. REACTIONS. (size)9=0-3-8, 6=Mechanical Max Horz 9=181(LC 9) Max Grav 9=876(LC 17), 6=800(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-444/63, 3-4=-646/64, 4-5=-701/48, 2-9=-435/64, 5-6=-701/2 BOT CHORD 7-9=-29/618 WEBS 4-7=0/393, 3-9=-479/0, 5-7=0/448 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 15-4-4, Exterior(2E) 15-4-4 to 18-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T03 Truss Type Piggyback Base Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689454 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:35 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ZwbKQQAUs2LgbJGWpbhqEwzIGk6-yUWAElcWca26JZiMWuv1S8sMHMicR0lOvbhIVMzQOs6 Scale = 1:79.1 1 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 11 19 20 21 22 23 24 25 3x6 6x8 5x8 3x6 3x6 3x8 MT18HS 3x4 3x6 3x6 3x8 3x4 3x6 5x8 3x6 5x8 3x6 8-3-88-3-8 16-4-88-1-0 21-6-85-2-0 29-7-88-1-0 37-11-08-3-8 -1-0-0 1-0-0 8-3-8 8-3-8 16-4-8 8-1-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 38-11-0 1-0-0 1-1-012-0-01-1-012-0-08.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-1-8], [3:0-1-12,0-1-8], [5:0-4-4,0-1-8], [6:0-4-4,0-1-8], [8:0-1-12,0-1-8], [9:0-2-8,0-1-8], [11:0-3-0,0-1-8], [12:0-2-0,0-1-8], [17:0-2-0,0-1-8], [18:0-3-0,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.46 0.82 0.48 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.33 0.07 (loc) 15-17 15-17 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 185 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E *Except* 5-6: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-17,8-12,2-17,9-12: 2x3 SPF No.2, 2-18,9-11: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-10-15 oc purlins, except end verticals, and 2-0-0 oc purlins (4-11-6 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-15, 5-14, 8-14 REACTIONS. (size)18=0-3-8, 11=0-3-8 Max Horz 18=200(LC 9) Max Grav 18=1742(LC 17), 11=1740(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2243/0, 3-5=-1735/5, 5-6=-1343/34, 6-8=-1731/0, 8-9=-2239/0, 2-18=-1616/0, 9-11=-1614/0 BOT CHORD 17-18=-162/567, 15-17=0/1885, 14-15=0/1391, 12-14=0/1771, 11-12=-54/423 WEBS 3-17=0/290, 3-15=-632/109, 5-15=0/643, 6-14=0/617, 8-14=-631/109, 8-12=0/290, 2-17=0/1391, 9-12=0/1387 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 35-11-0, Exterior(2E) 35-11-0 to 38-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T03A Truss Type Piggyback Base Qty 4 Ply 1 125 Bear Creek Job Reference (optional) I45689455 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:37 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-usdwfRem8BIqZtskeJxVYZxgP9NKvsBgMvAPZFzQOs4 Scale = 1:85.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 20 19 18 17 16 15 28 29 30 31 32 3x6 5x8 6x10 3x8 MT18HS 3x6 2x4 4x6 6x8 2x4 2x4 3x6 5x6 4x8 6x16 3x4 3x4 3x4 3x4 3x6 3x8 3x4 3x6 5x6 3x6 5x8 1-3-0 1-3-0 2-3-8 1-0-8 5-11-13 3-8-5 9-8-3 3-8-5 13-4-8 3-8-5 16-4-8 3-0-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 -1-0-0 1-0-0 1-3-0 1-3-0 2-3-8 1-0-8 5-11-13 3-8-5 9-8-3 3-8-5 13-4-8 3-8-5 16-4-8 3-0-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 38-11-0 1-0-0 1-1-012-0-01-1-00-8-012-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [3:0-3-0,0-2-4], [6:0-1-12,0-1-8], [7:0-1-12,0-1-8], [9:0-5-8,0-1-12], [10:0-6-0,0-1-8], [11:0-1-12,0-1-8], [13:0-2-8,0-1-8], [15:0-3-0,0-1-8], [16:0-2-4,0-1-8], [19:0-2-12,0-1-8], [21:0-2-12,0-2-12], [24:0-9-8,0-4-0], [26:0-4-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.61 0.80 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.33 0.14 (loc) 16-18 16-18 15 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 211 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 10-12: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 4-25,8-20: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 9-21,9-19,9-18,10-18,11-18: 2x4 SPF No.2, 2-27: 2x4 SPF-S Stud 13-15: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-3-3 oc purlins, except end verticals, and 2-0-0 oc purlins (4-10-6 max.): 9-10. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. Except: 1 Row at midpt 8-21 WEBS 1 Row at midpt 9-19, 9-18, 11-18 REACTIONS. (size)27=0-3-8, 15=0-3-8 Max Horz 27=200(LC 9) Max Grav 27=1705(LC 17), 15=1731(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1320/0, 3-4=-2872/0, 4-6=-2456/0, 6-7=-2211/0, 7-8=-1936/0, 8-9=-1919/44, 9-10=-1333/34, 10-11=-1719/0, 11-13=-2224/0, 2-27=-1628/0, 13-15=-1604/0 BOT CHORD 23-24=-32/2609, 22-23=0/2133, 21-22=0/1900, 18-19=0/1360, 16-18=0/1759, 15-16=-55/416 WEBS 3-26=-1774/0, 24-26=-38/1423, 3-24=0/1748, 4-23=-506/81, 6-22=-348/59, 7-22=0/403, 7-21=-528/68, 19-21=0/1302, 9-21=-78/1064, 10-18=0/593, 11-18=-629/110, 11-16=0/287, 2-26=0/1145, 13-16=0/1383 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-2-4, Interior(1) 2-2-4 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 35-11-0, Exterior(2E) 35-11-0 to 38-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T03B Truss Type PIGGYBACK BASE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689456 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:39 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-rFlh47f0gpZYoB07lkzzd_033z4JNk_zqCfWe8zQOs2 Scale = 1:80.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 29 28 27 26 25 24 23 22 21 20 19 18 17 30 31 32 33 34 35 36 37 3x6 6x8 5x8 3x6 3x6 2x4 2x4 4x6 2x4 3x4 3x8 3x4 3x4 3x4 6x8 8x8 4x6 6x10 4x6 4x10 3x4 3x4 3x8 3x6 3x6 5x6 5x6 5-7-35-7-3 12-4-06-8-13 16-4-84-0-8 18-6-102-2-2 21-6-82-11-14 22-7-81-1-0 26-4-123-9-4 32-8-36-3-7 37-11-05-2-13 -0-11-0 0-11-0 4-3-0 4-3-0 8-3-8 4-0-8 12-4-0 4-0-8 16-4-8 4-0-8 18-6-10 2-2-2 21-6-8 2-11-14 22-7-8 1-1-0 26-4-12 3-9-4 30-2-0 3-9-4 33-11-4 3-9-4 37-11-0 3-11-12 38-10-0 0-11-0 1-1-012-0-01-1-03-0-012-0-08.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-1-8], [4:0-1-12,0-1-8], [6:0-1-12,0-1-8], [7:0-6-4,0-2-4], [9:0-5-12,0-2-0], [10:0-2-12,0-2-0], [13:0-1-12,0-1-8], [14:0-2-0,0-1-8], [17:0-2-12,0-3-0], [19:0-4-4,0-1-8], [21:0-7-8,0-4-8], [23:0-2-0,Edge], [25:0-1-12,0-1-12], [29:0-2-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.41 0.71 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.40 0.33 (loc) 20 20 17 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 232 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-25: 2x4 SPF No.2, 2-29,15-17: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-11 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-10 max.): 7-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 23-24. 1 Row at midpt 8-23 WEBS 1 Row at midpt 6-25, 7-25, 9-23, 10-22, 11-19, 3-29, 14-17 REACTIONS. (size)29=0-3-8, 17=0-3-8 Max Horz 29=-198(LC 8) Max Grav 29=1726(LC 17), 17=1713(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-353/51, 3-4=-2152/0, 4-6=-1916/0, 6-7=-1640/18, 7-8=-1763/0, 8-9=-1772/0, 9-10=-2097/0, 10-11=-2393/0, 11-13=-1940/0, 13-14=-2117/0, 14-15=-337/46, 2-29=-355/51, 15-17=-343/47 BOT CHORD 27-29=0/1824, 26-27=0/1786, 25-26=0/1623, 22-23=0/1795, 21-22=0/1961, 10-21=0/1121, 18-19=0/1685, 17-18=0/1657 WEBS 4-26=-303/85, 6-26=-2/495, 6-25=-639/86, 7-25=-1339/0, 23-25=0/2419, 7-23=0/2071, 9-22=-14/990, 10-22=-1052/2, 19-21=0/2051, 11-21=0/686, 11-19=-997/0, 13-19=-266/81, 3-29=-1971/0, 14-17=-1950/0 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 35-10-0, Exterior(2E) 35-10-0 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T03C Truss Type PIGGYBACK BASE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689457 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:41 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-ndtRVohGCQpG2UAWt9?SiP6PYnmnreUGHW8di0zQOs0 Scale = 1:80.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 29 28 27 26 25 24 23 22 21 20 19 18 17 30 31 32 33 34 35 36 37 3x6 6x8 5x8 3x6 3x6 2x4 2x4 4x6 2x4 3x4 3x8 3x4 3x4 3x4 6x8 8x8 4x6 6x10 4x6 4x10 3x4 3x4 3x8 3x6 3x6 5x6 5x6 5-7-35-7-3 12-4-06-8-13 16-4-84-0-8 18-6-102-2-2 21-6-82-11-14 22-7-81-1-0 26-4-123-9-4 32-8-36-3-7 37-11-05-2-13 -0-11-0 0-11-0 4-3-0 4-3-0 8-3-8 4-0-8 12-4-0 4-0-8 16-4-8 4-0-8 18-6-10 2-2-2 21-6-8 2-11-14 22-7-8 1-1-0 26-4-12 3-9-4 30-2-0 3-9-4 33-11-4 3-9-4 37-11-0 3-11-12 38-10-0 0-11-0 1-1-012-0-01-1-03-0-012-0-08.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-1-8], [4:0-1-12,0-1-8], [6:0-1-12,0-1-8], [7:0-6-4,0-2-4], [9:0-5-12,0-2-0], [10:0-2-12,0-2-0], [13:0-1-12,0-1-8], [14:0-2-0,0-1-8], [17:0-2-12,0-3-0], [19:0-4-4,0-1-8], [21:0-7-8,0-4-8], [23:0-2-0,Edge], [25:0-1-12,0-1-12], [29:0-2-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.41 0.71 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.40 0.33 (loc) 20 20 17 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 232 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-25: 2x4 SPF No.2, 2-29,15-17: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-11 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-10 max.): 7-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 23-24. 1 Row at midpt 8-23 WEBS 1 Row at midpt 6-25, 7-25, 9-23, 10-22, 11-19, 3-29, 14-17 REACTIONS. (size)29=0-3-8, 17=0-3-8 Max Horz 29=-198(LC 8) Max Grav 29=1726(LC 17), 17=1713(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-353/51, 3-4=-2152/0, 4-6=-1916/0, 6-7=-1640/18, 7-8=-1763/0, 8-9=-1772/0, 9-10=-2097/0, 10-11=-2393/0, 11-13=-1940/0, 13-14=-2117/0, 14-15=-337/46, 2-29=-355/51, 15-17=-343/47 BOT CHORD 27-29=0/1824, 26-27=0/1786, 25-26=0/1623, 22-23=0/1795, 21-22=0/1961, 10-21=0/1121, 18-19=0/1685, 17-18=0/1657 WEBS 4-26=-303/85, 6-26=-2/495, 6-25=-639/86, 7-25=-1339/0, 23-25=0/2419, 7-23=0/2071, 9-22=-14/990, 10-22=-1052/2, 19-21=0/2051, 11-21=0/686, 11-19=-997/0, 13-19=-266/81, 3-29=-1971/0, 14-17=-1950/0 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 35-10-0, Exterior(2E) 35-10-0 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T04 Truss Type Piggyback Base Qty 18 Ply 1 125 Bear Creek Job Reference (optional) I45689458 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:42 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ZwbKQQAUs2LgbJGWpbhqEwzIGk6-FqRpi8ivzkx7feliRtXhFceUnA5JaA2PWAtAFSzQOs? Scale = 1:78.1 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 18 19 20 21 22 23 24 3x8 MT18HS 6x8 5x8 3x8 MT18HS 3x6 3x8 MT18HS 3x4 3x6 3x6 3x8 3x4 3x8 3x6 4x8 5x8 3x6 8-3-88-3-8 16-4-88-1-0 21-6-85-2-0 29-5-127-11-4 37-7-88-1-12 -1-0-0 1-0-0 8-3-8 8-3-8 16-4-8 8-1-0 21-6-8 5-2-0 29-5-12 7-11-4 37-7-8 8-1-12 1-1-012-0-01-3-512-0-08.00 12 Plate Offsets (X,Y)-- [2:0-2-8,0-1-8], [4:0-1-12,0-1-8], [5:0-4-8,0-1-12], [6:0-4-0,0-1-9], [7:0-1-12,0-1-8], [9:0-2-12,0-1-12], [11:0-2-8,0-1-8], [16:0-2-0,0-1-8], [17:0-3-0,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.83 0.81 0.57 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.33 0.06 (loc) 14-16 14-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 180 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-5,6-8: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 4-14,5-14,5-13,6-13: 2x4 SPF No.2, 9-10,2-17: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-11-12 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-14, 5-13, 7-13 REACTIONS. (size)17=0-3-8, 10=Mechanical Max Horz 17=197(LC 7) Max Grav 17=1731(LC 17), 10=1659(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2225/0, 4-5=-1716/8, 5-6=-1322/37, 6-7=-1707/0, 7-9=-2159/0, 9-10=-1536/0, 2-17=-1605/0 BOT CHORD 16-17=-171/552, 14-16=0/1865, 13-14=0/1370, 11-13=0/1715 WEBS 4-16=0/290, 4-14=-634/109, 5-14=0/645, 6-13=0/613, 7-13=-595/112, 9-11=0/1503, 2-16=0/1386 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 34-4-12, Exterior(2E) 34-4-12 to 37-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T05 Truss Type COMMON Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689459 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:42 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-FqRpi8ivzkx7feliRtXhFceWCAEmaHnPWAtAFSzQOs? Scale = 1:35.0 1 2 3 4 5 8 7 6 9 10 4x6 5x12 5x12 2x4 5-11-85-11-8 11-11-05-11-8 -0-11-0 0-11-0 5-11-8 5-11-8 11-11-0 5-11-8 12-10-0 0-11-0 1-2-05-7-101-2-09.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.67 0.21 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-7: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=101(LC 9) Max Grav 8=529(LC 1), 6=529(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-455/59, 3-4=-455/59, 2-8=-464/85, 4-6=-464/85 BOT CHORD 7-8=0/274, 6-7=0/274 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 2-11-8, Exterior(2R) 2-11-8 to 8-11-8, Interior(1) 8-11-8 to 9-10-0, Exterior(2E) 9-10-0 to 12-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T06 Truss Type Common Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689460 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:43 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-j0_CwUjXk13_HoJu_a2wnqBiCaUcJYcZkqdjnvzQOs_ Scale = 1:59.9 1 2 3 4 5 6 10 9 8 7 11 12 13 14 15 16 4x6 3x6 3x16 MT18HS 3x8 3x4 3x4 3x6 6x6 5x6 10-5-810-5-8 20-11-010-5-8 -1-0-0 1-0-0 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 20-11-0 5-4-0 1-3-09-11-91-3-010.00 12 Plate Offsets (X,Y)-- [7:Edge,0-2-8], [10:0-2-12,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.59 0.62 0.87 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.29 -0.50 0.02 (loc) 8-10 8-10 7 l/defl >853 >498 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 89 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 7-9: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)10=0-3-8, 7=0-3-8 Max Horz 10=166(LC 9) Max Grav 10=991(LC 17), 7=926(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-412/70, 3-4=-819/54, 4-5=-821/54, 5-6=-384/43, 2-10=-414/68, 6-7=-327/38 BOT CHORD 8-10=-18/739, 7-8=0/673 WEBS 4-8=0/675, 3-10=-648/0, 5-7=-664/0 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 17-9-4, Exterior(2E) 17-9-4 to 20-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T07 Truss Type Common Qty 4 Ply 1 125 Bear Creek Job Reference (optional) I45689461 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:44 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-BCYa7qj9VLBrvyu5YHZ9K1kp8_pM2BfizUMHILzQOrz Scale = 1:30.1 1 2 3 4 5 6 7 8 9 10 11 12 4x6 3x8 3x4 3x4 5x8 3x8 3x4 3x4 8-4-88-4-8 16-9-08-4-8 -1-0-0 1-0-0 8-4-8 8-4-8 16-9-0 8-4-8 17-9-0 1-0-0 0-9-03-6-80-9-04.00 12 Plate Offsets (X,Y)-- [2:0-5-5,Edge], [4:0-3-0,0-2-8], [6:0-5-5,Edge], [8:0-4-0,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.83 0.59 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.09 -0.19 0.03 (loc) 2-8 6-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 53 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 SLIDER Left 2x4 SPF-S Stud -t 4-4-14, Right 2x4 SPF-S Stud -t 4-4-14 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=33(LC 10) Max Uplift 2=-4(LC 6), 6=-4(LC 7) Max Grav 2=730(LC 1), 6=730(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1109/99, 4-6=-1109/99 BOT CHORD 2-8=-26/964, 6-8=-26/964 WEBS 4-8=0/361 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 5-4-8, Exterior(2R) 5-4-8 to 11-4-8, Interior(1) 11-4-8 to 14-9-0, Exterior(2E) 14-9-0 to 17-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T08 Truss Type Common Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689462 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:44 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-BCYa7qj9VLBrvyu5YHZ9K1kx8_wn2CYizUMHILzQOrz Scale = 1:34.4 1 2 3 4 5 8 7 6 9 10 4x6 2x4 2x4 3x8 6x6 6x6 5-1-05-1-0 10-2-05-1-0 -1-0-0 1-0-0 5-1-0 5-1-0 10-2-0 5-1-0 11-2-0 1-0-0 1-3-05-5-131-3-010.00 12 Plate Offsets (X,Y)-- [2:0-3-4,0-1-12], [4:0-3-4,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.32 0.17 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=102(LC 9) Max Grav 8=464(LC 1), 6=464(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-367/68, 3-4=-367/68, 2-8=-419/87, 4-6=-419/87 NOTES-(6-7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 8-2-0, Exterior(2E) 8-2-0 to 11-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 7) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T09 Truss Type Common Qty 2 Ply 1 125 Bear Creek Job Reference (optional) I45689463 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:45 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-fP6yLAknGfJhW6TH6?4OsFG6xOG0nfosC86qqnzQOry Scale = 1:34.4 1 2 3 4 7 6 5 8 9 4x6 6x6 2x4 2x4 3x8 6x6 5-1-05-1-0 10-2-05-1-0 -1-0-0 1-0-0 5-1-0 5-1-0 10-2-0 5-1-0 1-3-05-5-131-3-010.00 12 Plate Offsets (X,Y)-- [2:0-3-4,0-1-12], [4:0-3-4,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.32 0.17 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7,4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-8, 5=Mechanical Max Horz 7=97(LC 7) Max Grav 7=468(LC 1), 5=391(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-373/65, 3-4=-366/63, 2-7=-423/85, 4-5=-347/54 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 7-0-4, Exterior(2E) 7-0-4 to 10-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T10 Truss Type Common Qty 2 Ply 1 125 Bear Creek Job Reference (optional) I45689464 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:46 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-7bgKYWlP1yRY8G2TgibdPSpF_ocTW61?RorONEzQOrx Scale = 1:35.7 1 2 3 6 5 4 7 8 3x4 4x6 3x4 2x4 2x4 3x8 5-1-05-1-0 8-8-03-7-0 5-1-0 5-1-0 8-8-0 3-7-0 1-3-05-5-132-6-010.00 12 Plate Offsets (X,Y)-- [1:0-1-8,0-1-8], [3:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.43 0.16 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6,3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 4=Mechanical Max Horz 6=97(LC 7) Max Grav 6=335(LC 1), 4=335(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-259/41, 1-6=-295/52, 3-4=-314/48 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 5-6-4, Exterior(2E) 5-6-4 to 8-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T11 Truss Type Common Qty 2 Ply 1 125 Bear Creek Job Reference (optional) I45689465 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:47 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-cnEilsm1oGZPmPdfDQ6sygLQjByiFZH9fSbxvgzQOrw Scale = 1:35.7 1 2 3 6 5 4 7 8 3x4 4x6 3x4 2x4 2x4 3x8 5-1-05-1-0 8-8-03-7-0 5-1-0 5-1-0 8-8-0 3-7-0 1-3-05-5-132-6-010.00 12 Plate Offsets (X,Y)-- [1:0-1-8,0-1-8], [3:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.43 0.16 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6,3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=Mechanical, 4=Mechanical Max Horz 6=97(LC 9) Max Grav 6=335(LC 1), 4=335(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-259/41, 1-6=-295/52, 3-4=-314/48 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 5-6-4, Exterior(2E) 5-6-4 to 8-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss T12 Truss Type Piggyback Base Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689466 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:48 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-4_o5zCmfYahGNZCsn7e5UtuT_b8u_rvIu6KUR6zQOrv Scale = 1:84.1 1 2 3 4 5 6 7 8 9 10 11 12 13 26 25 24 23 22 21 20 19 18 17 16 15 14 27 28 29 30 31 3x6 5x8 5x8 3x8 MT18HS 3x6 2x4 4x6 6x8 2x4 2x4 3x6 5x6 4x8 6x10 3x4 3x4 3x4 3x4 3x6 3x8 3x4 3x8 5x6 3x6 4x8 1-3-0 1-3-0 2-3-8 1-0-8 5-11-13 3-8-5 9-8-3 3-8-5 13-4-8 3-8-5 16-4-8 3-0-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 -1-0-0 1-0-0 1-3-0 1-3-0 2-3-8 1-0-8 5-11-13 3-8-5 9-8-3 3-8-5 13-4-8 3-8-5 16-4-8 3-0-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 1-1-012-0-01-1-00-8-012-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [3:0-3-0,0-2-4], [6:0-1-12,0-1-8], [7:0-1-12,0-1-8], [9:0-5-8,0-1-12], [10:0-4-8,0-1-12], [11:0-1-12,0-1-8], [13:0-2-12,0-1-12], [14:0-3-0 ,0-1-8], [15:0-2-8,0-1-8], [18:0-2-12,0-1-8], [20:0-2-12,0-2-12], [23:0-6-4,0-4-0], [25:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.91 0.80 0.74 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.34 0.13 (loc) 15-17 15-17 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 210 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 10-12: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 4-24,8-19: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 9-20,9-18,9-17,10-17,11-17: 2x4 SPF No.2, 2-26: 2x4 SPF-S Stud 13-14: 2x6 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-10-4 max.): 9-10. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. Except: 1 Row at midpt 8-20 WEBS 1 Row at midpt 9-18, 9-17, 11-17 REACTIONS. (size)26=0-3-8, 14=0-3-8 Max Horz 26=195(LC 7) Max Grav 26=1706(LC 17), 14=1664(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1320/0, 3-4=-2869/0, 4-6=-2456/0, 6-7=-2213/0, 7-8=-1937/0, 8-9=-1920/44, 9-10=-1334/35, 10-11=-1724/0, 11-13=-2226/0, 2-26=-1629/0, 13-14=-1536/0 BOT CHORD 22-23=-46/2600, 21-22=0/2127, 20-21=0/1894, 17-18=0/1355, 15-17=0/1770, 14-15=-23/311 WEBS 3-25=-1770/0, 23-25=-48/1416, 3-23=-2/1744, 4-22=-503/85, 6-21=-348/60, 7-21=0/403, 7-20=-528/69, 18-20=0/1297, 9-20=-80/1063, 10-17=0/600, 11-17=-642/113, 11-15=0/282, 2-25=0/1146, 13-15=0/1485 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-2-4, Interior(1) 2-2-4 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 34-8-4, Exterior(2E) 34-8-4 to 37-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss TG02 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689467 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:50 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-0MwrOtow4Bx_dtMEvYgZZIzuUPvkSmdbLQpbW?zQOrt Scale = 1:82.7 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 17 18 19 21 2046474849 3x6 5x8 5x6 3x6 4x6 4x6 3x6 3x4 4x6 3x4 3x6 4x6 5x6 4x6 5x6 4x6 2x4 2x4 3x8 3x8 3x8 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6-6-106-6-10 12-10-136-4-2 21-6-38-7-6 27-10-66-4-2 34-5-06-6-10 6-6-10 6-6-10 12-10-13 6-4-2 21-6-3 8-7-6 27-10-6 6-4-2 34-5-0 6-6-10 1-3-012-0-01-3-012-0-010.00 12 Plate Offsets (X,Y)-- [1:0-3-0,0-1-8], [3:0-0-12,0-1-8], [4:0-2-0,0-3-4], [5:0-3-8,0-2-4], [8:0-3-4,0-1-8], [9:Edge,0-3-8], [10:0-3-0,0-1-12], [15:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.59 0.40 0.60 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.14 0.03 (loc) 12-14 12-14 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 272 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-14,4-14,4-12,5-12,6-12: 2x4 SPF No.2, 3-17: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-5 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 4-12, 6-12 REACTIONS. (size)16=0-5-8, 9=0-3-8 Max Horz 16=186(LC 5) Max Grav 16=1480(LC 26), 9=1459(LC 26) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1751/0, 3-4=-1459/30, 4-5=-1040/63, 5-6=-1450/33, 6-8=-1720/0, 1-16=-1366/0, 8-9=-1343/0 BOT CHORD 15-16=-171/341, 14-15=0/1359, 12-14=0/1071, 10-12=0/1244 WEBS 3-14=-406/125, 14-17=-6/565, 4-17=-6/565, 12-19=0/528, 5-19=0/528, 1-15=0/1089, 8-10=0/1064, 12-20=-370/123, 6-20=-383/126 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Vertical gable studs spaced at 2-0-0 oc and horizontal gable studs spaced at 0-1-4 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 8 lb down and 10 lb up at 15-5-4, 8 lb down and 10 lb up at 17-5-4, and 8 lb down and 10 lb up at 19-5-4, and 8 lb down and 10 lb up at 21-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss TG02 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689467 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:50 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-0MwrOtow4Bx_dtMEvYgZZIzuUPvkSmdbLQpbW?zQOrt LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 5-8=-60, 9-16=-20 Concentrated Loads (lb) Vert: 12=2(B) 47=2(B) 48=2(B) 49=2(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss TG03 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689468 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:52 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-yl1bpZqAcoBisBVd0zi1fj3ItCa?wlgupkIiatzQOrr Scale = 1:61.3 1 2 3 4 5 6 7 8 9 10 11 13 12 34 35 36 37 38 39 3x6 4x6 3x6 5x12 5x6 5x6 4x6 3x8 2x4 2x4 5x12 5x6 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 10-5-810-5-8 20-11-010-5-8 -1-0-0 1-0-0 5-4-8 5-4-8 10-5-8 5-1-0 15-6-8 5-1-0 20-11-0 5-4-8 21-11-0 1-0-0 1-3-09-11-91-3-010.00 12 Plate Offsets (X,Y)-- [2:0-9-7,0-0-3], [10:0-9-7,0-0-3] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.34 0.47 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.12 0.01 (loc) 2-13 2-13 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 150 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 6-13: 2x4 SPF No.2 OTHERS 2x3 SPF No.2 SLIDER Left 2x8 SP 2400F 2.0E -t 3-8-4, Right 2x8 SP 2400F 2.0E -t 3-8-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 10=0-3-8 Max Horz 2=-148(LC 8) Max Grav 2=999(LC 17), 10=999(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-1016/20, 5-6=-828/53, 6-7=-828/53, 7-10=-1016/20 BOT CHORD 2-13=-11/777, 10-13=0/708 WEBS 6-13=0/681 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 18-11-0, Exterior(2E) 18-11-0 to 21-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss TG04 Truss Type PIGGYBACK BASE GIRDE Qty 1 Ply 3 125 Bear Creek Job Reference (optional) I45689469 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:53 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ZwbKQQAUs2LgbJGWpbhqEwzIGk6-Qxb_0vqoN6JZUK4pagDGBxbXOc1_fFR12O2F6KzQOrq Scale = 1:74.9 1 2 3 4 5 6 7 8 9 10 11 22 21 20 19 18 17 16 15 14 13 12 23 24 25 26 27 28 3x6 5x8 5x8 3x6 8x14 MT18HS 4x6 3x6 8x8 8x8 4x6 8x8 8x8 4x6 8x8 3x6 8x8 8x14 MT18HS 4x6 2x4 8x10 4-5-154-5-15 8-8-64-2-7 12-10-134-2-7 17-1-44-2-7 21-6-34-4-15 25-8-104-2-7 29-11-14-2-7 34-5-04-5-15 4-5-15 4-5-15 8-8-6 4-2-7 12-10-13 4-2-7 17-1-4 4-2-7 17-2-8 0-1-4 21-6-3 4-3-11 25-8-10 4-2-7 29-11-1 4-2-7 34-5-0 4-5-15 1-3-012-0-01-3-012-0-010.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-1-8], [4:0-1-8,0-1-12], [5:0-6-4,0-2-0], [7:0-6-4,0-2-0], [8:0-1-8,0-1-12], [9:0-2-0,0-1-8], [12:Edge,0-3-8], [13:0-3-8,0-4-12], [14:0-3-8,0-4-12], [16:0-3-8,0-4-12], [17:0-5-0,0-5-0], [18:0-3-8,0-4-8], [20:0-4-0,0-4-12], [21:0-3-8,0-4-8], [22:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.10 0.04 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.01 0.00 (loc) 14 14 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 721 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-18,5-18,7-16,8-16,6-17: 2x4 SPF No.2 5-17,7-17: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 5-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 17-18,16-17. REACTIONS. (size)22=0-5-8, 12=0-3-8, 17=0-3-8 Max Horz 22=186(LC 9) Max Grav 22=604(LC 25), 12=620(LC 18), 17=1882(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-614/0, 3-4=-419/37, 8-9=-434/52, 9-11=-628/0, 1-22=-527/0, 11-12=-544/0 BOT CHORD 20-21=-82/521, 18-20=-72/337, 14-16=0/281, 13-14=0/433 WEBS 3-20=-272/71, 4-20=-2/380, 4-18=-509/103, 5-18=-38/618, 5-17=-818/21, 7-16=-36/623, 8-16=-505/102, 8-14=-1/374, 9-14=-267/69, 1-21=0/351, 11-13=0/362, 7-17=-806/8, 6-17=-299/61 NOTES-(12-13) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 9-13 2x4 - 1 row at 0-5-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 8-7-14, Exterior(2R) 8-7-14 to 25-8-10, Interior(1) 25-8-10 to 31-3-4, Exterior(2E) 31-3-4 to 34-3-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Bearing at joint(s) 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss TG04 Truss Type PIGGYBACK BASE GIRDE Qty 1 Ply 3 125 Bear Creek Job Reference (optional) I45689469 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:53 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ZwbKQQAUs2LgbJGWpbhqEwzIGk6-Qxb_0vqoN6JZUK4pagDGBxbXOc1_fFR12O2F6KzQOrq 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V01 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689470 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:54 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-u79MDFrQ8QRQ5Uf08OkVk88eN0LoOghBG2npfmzQOrp Scale = 1:81.9 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 22 23 3x6 4x6 3x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 31-0-931-0-9 15-6-4 15-6-4 31-0-9 15-6-4 0-0-412-11-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.34 0.13 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 119 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-4,8-11: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 6-15: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15, 5-17, 7-14 REACTIONS.All bearings 31-0-9. (lb) - Max Horz 1=195(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 17, 18, 19, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 15=398(LC 20), 17=460(LC 17), 18=443(LC 17), 19=390(LC 17), 14=459(LC 18), 13=443(LC 18), 12=390(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-17=-259/123, 7-14=-259/123 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-6-4, Interior(1) 3-6-4 to 12-6-4, Exterior(2R) 12-6-4 to 18-6-4, Interior(1) 18-6-4 to 27-6-4, Exterior(2E) 27-6-4 to 30-7-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 17, 18, 19, 14, 13, 12. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V02 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689471 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:55 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-NKjkRbs2vjaHjeECh5GkGMhrOQh_74zKViXMBCzQOro Scale = 1:70.8 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 3x6 4x6 3x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 27-10-227-10-2 13-11-1 13-11-1 27-10-2 13-11-1 0-0-411-7-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.19 0.13 0.40 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 105 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3,9-11: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 6-15: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15 REACTIONS.All bearings 27-10-2. (lb) - Max Horz 1=-174(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1, 17, 18, 19, 14, 13, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 15=392(LC 20), 17=461(LC 17), 18=426(LC 17), 19=308(LC 17), 14=461(LC 18), 13=426(LC 18), 12=308(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-17=-258/123, 4-18=-250/119, 7-14=-258/122, 8-13=-251/119 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Interior(1) 3-4-13 to 10-11-1, Exterior(2R) 10-11-1 to 16-11-1, Interior(1) 16-11-1 to 24-5-5, Exterior(2E) 24-5-5 to 27-5-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 17, 18, 19, 14, 13, 12, 11. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V03 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689472 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:56 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-rWH6exthg1i8LopOFpnzpZD1iq0GsZATkMGvjfzQOrn Scale = 1:65.3 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 173x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-7-1224-7-12 12-3-14 12-3-14 24-7-12 12-3-14 0-0-410-3-40-0-410.00 12 Plate Offsets (X,Y)-- [1:0-1-9,0-1-8], [7:0-0-7,0-1-8], [11:0-2-9,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.16 0.13 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 24-7-12. (lb) - Max Horz 1=-154(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=363(LC 20), 12=453(LC 17), 13=445(LC 17), 9=452(LC 18), 8=445(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-257/123, 2-13=-258/116, 5-9=-257/123, 6-8=-258/117 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Interior(1) 3-4-13 to 9-3-14, Exterior(2R) 9-3-14 to 15-3-14, Interior(1) 15-3-14 to 21-2-14, Exterior(2E) 21-2-14 to 24-2-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 12, 13, 9, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V04 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689473 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:57 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-JirUsHtJRLq?yyOapWICMnmCGDMOb2qdy00TF5zQOrm Scale = 1:57.6 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 3x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 21-5-521-5-5 10-8-11 10-8-11 21-5-5 10-8-11 0-0-48-11-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.17 0.14 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 21-5-5. (lb) - Max Horz 1=-133(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=357(LC 20), 11=443(LC 17), 13=329(LC 17), 9=441(LC 18), 8=330(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-268/128, 5-9=-268/127 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Interior(1) 3-4-13 to 7-8-11, Exterior(2R) 7-8-11 to 13-8-11, Interior(1) 13-8-11 to 18-0-8, Exterior(2E) 18-0-8 to 21-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 13, 9, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V05 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689474 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:58 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-nvOs3cuxCeyra6znNEpRu_JM4dfnKVGmBgl0oXzQOrl Scale = 1:46.9 1 2 3 4 5 9 8 7 6 10 11 3x6 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 18-2-1518-2-15 9-1-8 9-1-8 18-2-15 9-1-8 0-0-47-7-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.23 0.32 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 57 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-8: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 18-2-15. (lb) - Max Horz 1=-112(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=318(LC 20), 9=533(LC 17), 6=533(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-317/140, 4-6=-311/139 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Interior(1) 3-4-13 to 6-1-8, Exterior(2R) 6-1-8 to 12-1-8, Interior(1) 12-1-8 to 14-10-2, Exterior(2E) 14-10-2 to 17-10-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V06 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689475 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:59 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-F5yFHyvZzy4iCFYzwxKgRCrWV12y3yzwQKVaKzzQOrk Scale = 1:38.9 1 2 3 4 5 8 7 6 9 10 11 123x4 5x6 3x4 2x4 2x4 2x4 2x4 2x4 15-0-915-0-9 7-6-4 7-6-4 15-0-9 7-6-4 0-0-46-3-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.31 0.13 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-0-9. (lb) - Max Horz 1=-93(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=339(LC 17), 8=411(LC 17), 6=410(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-6-4, Interior(1) 3-6-4 to 4-6-4, Exterior(2R) 4-6-4 to 10-6-4, Interior(1) 10-6-4 to 11-6-4, Exterior(2E) 11-6-4 to 14-7-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V07 Truss Type GABLE Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689476 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:51:59 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-F5yFHyvZzy4iCFYzwxKgRCrVF13T3zqwQKVaKzzQOrk Scale = 1:32.7 1 2 3 4 5 8 7 6 9 10 3x4 5x10 MT18HS 3x4 2x4 2x4 2x4 2x4 2x4 11-10-211-10-2 5-11-1 5-11-1 11-10-2 5-11-1 0-0-44-11-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.33 0.10 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 MT18HS Weight: 31 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-10-2. (lb) - Max Horz 1=72(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 8=295(LC 23), 6=295(LC 24) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Exterior(2R) 3-4-9 to 8-5-9, Exterior(2E) 8-5-9 to 11-5-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 8, 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V08 Truss Type Valley Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689477 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:52:00 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-jHWdUIwBkGCZpP79UervzPOi2RPWoPI3f_E7sQzQOrj Scale = 1:40.2 1 2 3 6 5 4 5x10 MT18HS 4x6 4x6 4x6 5x10 MT18HS 2x4 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 6-1-07-3-106-1-010.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-4], [6:0-0-0,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.11 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 MT18HS Weight: 35 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x6 SPF No.2 WEBS 2x6 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=2-11-0, 4=2-11-0, 5=2-11-0 Max Horz 6=148(LC 9) Max Uplift 6=-186(LC 6), 4=-186(LC 7) Max Grav 6=219(LC 9), 4=219(LC 8), 5=94(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=186, 4=186. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V09 Truss Type Valley Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689478 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:52:01 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-BU4?iexpVZKQRZiM2MM8Wdxs4rm1XtACte_gPszQOri Scale = 1:33.3 1 2 34 7 6 5 2x4 4x6 3x4 4x6 2x4 3x6 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 4-9-05-11-104-9-010.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [7:0-2-4,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.24 0.03 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=2-11-0, 5=2-11-0, 6=2-11-0 Max Horz 7=-122(LC 8) Max Uplift 7=-141(LC 6), 5=-79(LC 7), 6=-34(LC 11) Max Grav 7=165(LC 9), 5=103(LC 8), 6=193(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 6 except (jt=lb) 7=141. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V10 Truss Type Valley Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689479 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:52:02 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-fgeNv_xSFtSH3jGYc3uN3qT3pE6HGLEM6HjExIzQOrh Scale = 1:26.5 1 2 3 6 5 4 2x4 3x4 3x4 2x4 3x6 3x4 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 3-5-04-7-103-5-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.12 0.03 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=2-11-0, 4=2-11-0, 5=2-11-0 Max Horz 6=-91(LC 8) Max Uplift 6=-54(LC 6), 4=-54(LC 7) Max Grav 6=87(LC 18), 4=87(LC 17), 5=128(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V11 Truss Type Valley Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689480 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:52:02 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-fgeNv_xSFtSH3jGYc3uN3qT3cE5iGLYM6HjExIzQOrh Scale = 1:19.6 1 2 3 6 5 4 3x4 3x4 3x4 3x4 3x4 2x4 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 2-1-03-3-102-1-010.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.07 0.07 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=2-11-0, 4=2-11-0, 5=2-11-0 Max Horz 6=-61(LC 8) Max Uplift 6=-19(LC 6), 4=-19(LC 7) Max Grav 6=69(LC 18), 4=69(LC 17), 5=113(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 125_BEAR_CREEK Truss V12 Truss Type Valley Qty 1 Ply 1 125 Bear Creek Job Reference (optional) I45689481 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 15 17:52:03 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-8sCl6Ky40Ba8gtrk9nPcb20FfeQT?o8VLxTnTlzQOrg Scale = 1:12.7 1 2 3 5 4 2x4 2x4 2x4 2x4 2x4 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 0-9-01-11-100-9-010.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.05 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=2-11-0, 4=2-11-0 Max Horz 5=-31(LC 6) Max Grav 5=108(LC 1), 4=108(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=0ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). April 16,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths