HomeMy WebLinkAboutE1 - MAIN FLOOR ELECTRICAL PLANGFI GFIGFI GFIWPGFIWPGFI SMOKE DETECTOR SMOKE DETECTOR Scale Date Drawn By Checked By Project Number MEDLEY CREATIONS, INC. CARMEL, IN 46032 40 PINE VALLEY DR ARCHITECTURAL ARCHITECTURAL DESIGN STUDIO 5761 RAVINE RD. INDPLS., IN 46220 (317) 694-3359 c (317) 731-5760 f medleycreations@comcast.net www.medleycreationsinc.com M ARCHITECT'S SEAL RANDY GILLASPIE NEW LIVING AREA FLOOR PLAN WITH OWNER'S REQUESTED REVISIONS 4-26-2021 1/4" = 1'-0" E1 KOJ KOJ 6-15-2021 0321-0100MAIN FLOOR ELECTRICAL PLAN 1/4" = 1'-0"1 MAIN FLOOR ELECTRICAL PLAN No. Description Date GENERAL NOTES 1. BEFORE COMMENCING WITH WORK, CONFIRM ALL DIMENSIONS AND BURIED UTILITIES. 2. BEFORE FRAMING FOR WINDOW AND DOOR ROUGH OPENINGS. CONFIRM WITH OWNER ACTUAL UNIT MODEL FOR FINAL ROUGH OPENING SIZES. 3. WOOD FRAMING DIMENSION ARE TO FACE OF STUD UNLESS OTHERWISE NOTED. 4. ALL INTERIOR WALLS TO BE 4 1/2" THICK AND OF 2X4 STUD CONSTRUCTION @ 16" O.C. WITH (1) LAYER 1/2" GYP. BD. ON EACH SIDE UNLESS OTHERWISE NOTED. 5. COORDINATE WITH OWNER FOR LOCATIONS OF ALL ELECTRICAL OUTLETS AND LIGHT SWITCHES. 6. PATCH ALL PLASTER AND/OR GYP.BD. WALLS AND CEILINGS WHERE DEMOLITION WORK HAS COMPROMISED EXISTING FINISHES TO REMAIN. MATCH EXISTING TEXTURES OF ADJACENT AREA. 7. CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL EXISTING AREAS AFFECTED BY DEMOLITION AND SHCEDULED TO REMAIN. PROVIDE ALL SAFETY BARRIERS AND SHORING AS REQUIRED TO PROTECT AND PERFORM NEW SCOPE OF WORK. 8. INSULATION CLEARANCE: COMBUSTIBLE INSULATION SHALL BE SEPARATED A MINIMUM OF 3" FROM RECESSED LIGHTING FIXTURES, FAN MOTORS AND OTHER HEAT-PRODUCING DEVICES. 9. WHERE EAVES VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A 1" SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AT THE LOCATION OF THE VENT. 10. SMOKE DETECTORS: (A) DETECTORS SHALL BE INSTALLED IN EACH ROOM DESIGNED FOR SLEEPING, (B) OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, (C) ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. ON THE CEILING OF THE UPPER LEVEL NEAR THE TOP OR ABOVE EACH STAIRWAY, IN ANY MULTISTORY DWELLING, IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL, (E) IN THE LIVING AREA REMOTE FROM THE KITCHEN AND COOKING APPLIANCES, (F) ON THE BASEMENT CEILING AND NEAR COOKING APPLIANCES NEEDS TO BE PHOTOELECTRIC OR TEMP. SILENCING. 11. ALL NEW EXTERIOR WALLS SHALL BE 2X4 STUD CONSTRUCTION @ 16" O.C. WITH SPRAY FOAM INSULATION OR 2X6 @ 16" O.C. W/ R-19 BATT INSUALTION 06/28/21