HomeMy WebLinkAboutFoundation plan and details54' - 0"25' - 4"2' - 8" 14' - 8" 10' - 0"+- 34' - 1" 1 1 1 1 2 2 2 2 1 6 S0 3 S0 3 4 5 S0 O.H. DOOR OPENING 16' - 0"1' - 4" O.H. DOOR OPENING 8' - 0" 2' - 0" 5 4 S0 2 S0 6 6 7 MAIN FLOOR PLAN 0' - 0" GROUT CELLS SOLID WHERE ANCHOR BOLTS ARE PRESENT 8" CMU FOUNDATION WALL. TYPICAL ANCHOR BOLTS -THERE SHALL BE A MIN. OF TWO BOLTS PER WALL PLATE SECTION WITH ONE BOLT LOCATED NOT MORE THAN 12" FROM END OF THE PLATE. ANCHOR BOLTS SHALL BE 1/2" DIA. X 16" LONG "BENT- LEG" TYPE -GALVANIZED. 6' CENTER MAX. SPACING MAX. DISTANCE FROM ANY CORNER SHALL BE 12" MAX. CONTINUOUS 16"W X 10"D REINFORCED CONCRETE FOOTING. REINFORCED WITH (3) #5 REBAR. PROPOSED FOOTING SIZES IS BASED ON THE ASSUMPTION THAT THE EXISTING ALLOWABLE SOIL PRESSURE IS 2,000 PSF OR BETTER. IF SOIL CONDITIONS DO NOT EQUAL OR EXCEED 2,000 PSF CONTACT ARCHITECT. SILL SEAL FOAM INSULATION LAYER TREATED 2X4 SILL PLATE 1/2" DIA., 16" LONG MIN. GALV. BENT LEG ANCHOR BOLT 30" MIN DEPTH BELOW GRADE3' - 0"2" THICK RIGID INSULATION 10 MIL PLASTIC MOISTURE BARRIER REINF. CONC. SLAB ALUM BREAK MTL WRAP#4 BENT REBAR EVERY 36" SILL SEAL FOAM INSULATION LAYER TREATED 2X8 SILL PLATE 1/2" DIA., 16" LONG MIN. GALV. BENT LEG ANCHOR BOLT 1/2" EXPANSION JOINT MATERIAL 4" DEEP PEA GRAVEL OR COMPACTED DENSE GRADE AGGREGATE GROUT CELLS SOLID WHERE ANCHOR BOLTS ARE PRESENT 8" CMU FOUNDATION WALL. TYPICAL ANCHOR BOLTS -THERE SHALL BE A MIN. OF TWO BOLTS PER WALL PLATE SECTION WITH ONE BOLT LOCATED NOT MORE THAN 12" FROM END OF THE PLATE. ANCHOR BOLTS SHALL BE 1/2" DIA. X 16" LONG "BENT-LEG" TYPE -GALVANIZED. 6' CENTER MAX. SPACING MAX. DISTANCE FROM ANY CORNER SHALL BE 12" MAX. CONTRACTOR'S OPTION TO SUBSTITUTE CMU WALL WITH POURED CONCRETE CONTINUOUS 16"W X 10"D REINFORCED CONCRETE FOOTING. REINFORCED WITH (3) #5 REBAR. PROPOSED FOOTING SIZES IS BASED ON THE ASSUMPTION THAT THE EXISTING ALLOWABLE SOIL PRESSURE IS 2,000 PSF OR BETTER. IF SOIL CONDITIONS DO NOT EQUAL OR EXCEED 2,000 PSF CONTACT ARCHITECT. 10 MIL. PLASTIC MOISTURE BARRIER GARAGE SLAB SHALL SLOPE TOWARDS GARAGE DOORS (1% MAX. SLOPE). 4" THICK POURED CONC.; 4,000 PSI OVER 4" PEA GRAVEL OR GRANULAR COMPACTED BASE AND 10 MIL MOISTURE BARRIER. CONCRETE SHALL BE REINFORCED WITH 6X6 10/10 W.W.F..2' - 6"2" THICK RIGID INSULATION ALUM BREAK MTL COVER MAIN FLOOR PLAN 0' - 0" GARAGE LEVEL -1' - 2 1/2"7 1/4" 7 1/4"8" CMU FOUNDATION WALL. TYPICAL ANCHOR BOLTS -THERE SHALL BE A MIN. OF TWO BOLTS PER WALL PLATE SECTION WITH ONE BOLT LOCATED NOT MORE THAN 12" FROM END OF THE PLATE. ANCHOR BOLTS SHALL BE 1/2" DIA. X 16" LONG "BENT-LEG" TYPE -GALVANIZED. 6' CENTER MAX. SPACING MAX. DISTANCE FROM ANY CORNER SHALL BE 12" MAX. CONTRACTOR'S OPTION TO SUBSTITUTE CMU WALL WITH POURED CONCRETE CONTINUOUS 16"W X 10"D REINFORCED CONCRETE FOOTING. REINFORCED WITH (3) #5 REBAR. PROPOSED FOOTING SIZES IS BASED ON THE ASSUMPTION THAT THE EXISTING ALLOWABLE SOIL PRESSURE IS 2,000 PSF OR BETTER. IF SOIL CONDITIONS DO NOT EQUAL OR EXCEED 2,000 PSF CONTACT ARCHITECT. GROUT CELLS SOLID WHERE ANCHOR BOLTS ARE PRESENT 10 MIL PLASTIC MOISTURE BARRIER #4 BENT REBAR EVERY 36" CONCRETE STEP 2' - 7" 3' - 9 1/2"#4 BENT REBAR @ GARAGE DOOR OPENING - SPACED 36" A PART. CROSS TIED W/ #4 REBAR 1/2" EXPANSION JOINT MATERIAL 4" DEEP PEA GRAVEL OR COMPACTED DENSE GRADE AGGREGATE GROUT CELLS SOLID WHERE ANCHOR BOLTS ARE PRESENT 8" CMU FOUNDATION WALL. TYPICAL ANCHOR BOLTS -THERE SHALL BE A MIN. OF TWO BOLTS PER WALL PLATE SECTION WITH ONE BOLT LOCATED NOT MORE THAN 12" FROM END OF THE PLATE. ANCHOR BOLTS SHALL BE 1/2" DIA. X 16" LONG "BENT- LEG" TYPE -GALVANIZED. 6' CENTER MAX. SPACING MAX. DISTANCE FROM ANY CORNER SHALL BE 12" MAX. CONTINUOUS 16"W X 10"D REINFORCED CONCRETE FOOTING. REINFORCED WITH (3) #5 REBAR. PROPOSED FOOTING SIZES IS BASED ON THE ASSUMPTION THAT THE EXISTING ALLOWABLE SOIL PRESSURE IS 2,000 PSF OR BETTER. IF SOIL CONDITIONS DO NOT EQUAL OR EXCEED 2,000 PSF CONTACT ARCHITECT. 10 MIL. PLASTIC MOISTURE BARRIER CONCRETE APRON SHALL SLOPE AWAY FROM GARAGE (1% MAX. SLOPE). AIR ENTRAINED 4" THICK POURED CONC.; 4,000 PSI OVER 4" PEA GRAVEL OR GRANULAR COMPACTED BASE. CONCRETE SHALL BE REINFORCED WITH 6X6 10/10 W.W.F.. 4" DEEP PEA GRAVEL OR COMPACTED DENSE GRADE AGGREGATE GARAGE SLAB SHALL SLOPE TOWARDS GARAGE DOORS (1% MAX. SLOPE). 4" THICK POURED CONC.; 4,000 PSI OVER 4" PEA GRAVEL OR GRANULAR COMPACTED BASE AND 10 MIL MOISTURE BARRIER. CONCRETE SHALL BE REINFORCED WITH 6X6 10/10 W.W.F.. CMU BEYOND 2' - 7"2" RIGID INSUL MAIN FLOOR PLAN 0' - 0" GARAGE LEVEL -1' - 2 1/2"7"7" 8" CMU FOUNDATION WALL. TYPICAL ANCHOR BOLTS -THERE SHALL BE A MIN. OF TWO BOLTS PER WALL PLATE SECTION WITH ONE BOLT LOCATED NOT MORE THAN 12" FROM END OF THE PLATE. ANCHOR BOLTS SHALL BE 1/2" DIA. X 16" LONG "BENT-LEG" TYPE -GALVANIZED. 6' CENTER MAX. SPACING MAX. DISTANCE FROM ANY CORNER SHALL BE 12" MAX. CONTRACTOR'S OPTION TO SUBSTITUTE CMU WALL WITH POURED CONCRETE CONTINUOUS 16"W X 10"D REINFORCED CONCRETE FOOTING. REINFORCED WITH (3) #5 REBAR. PROPOSED FOOTING SIZES IS BASED ON THE ASSUMPTION THAT THE EXISTING ALLOWABLE SOIL PRESSURE IS 2,000 PSF OR BETTER. IF SOIL CONDITIONS DO NOT EQUAL OR EXCEED 2,000 PSF CONTACT ARCHITECT. GROUT CELLS SOLID WHERE ANCHOR BOLTS ARE PRESENT 2" THICK RIGID INSULATION 10 MIL PLASTIC MOISTURE BARRIER SILL SEAL FOAM INSULATION LAYER TREATED 2X4 SILL PLATE 1/2" DIA., 16" LONG MIN. GALV. BENT LEG ANCHOR BOLT CONCRETE STEP #4 BENT REBAR EVERY 36" (2) #5 HORZ. REBAR 1' - 4"4"8"8" Scale Date Drawn By Checked By Project Number MEDLEY CREATIONS, INC. CARMEL, IN 46032 40 PINE VALLEY DR ARCHITECTURAL ARCHITECTURAL DESIGN STUDIO 5761 RAVINE RD. INDPLS., IN 46220 (317) 694-3359 c (317) 731-5760 f medleycreations@comcast.net www.medleycreationsinc.com M ARCHITECT'S SEAL RANDY GILLASPIE NEW LIVING AREA FLOOR PLAN WITH OWNER'S REQUESTED REVISIONS 4-26-2021 As indicated S0 KOJ KOJ 5-25-2021 0321-0100FOUNDATION PLAN AND DETAILS 1/4" = 1'-0"1 FOUNDATION PLAN PLAN NOTES FOR S0 1 8" CMU FOUNDATION WALL. TYPICAL ANCHOR BOLTS -THERE SHALL BE A MIN. OF TWO BOLTS PER WALL PLATE SECTION WITH ONE BOLT LOCATED NOT MORE THAN 12" FROM END OF THE PLATE. ANCHOR BOLTS SHALL BE 1/2" DIA. X 16" LONG "BENT-LEG" TYPE -GALVANIZED. 6' CENTER MAX. SPACING MAX. DISTANCE FROM ANY CORNER SHALL BE 12" MAX. CONTRACTOR'S OPTION TO SUBSTITUTE CMU WALL WITH POURED CONCRETE 2 CONTINUOUS 16"W X 10"D REINFORCED CONCRETE FOOTING. REINFORCED WITH (2) #5 REBAR. PROPOSED FOOTING SIZES IS BASED ON THE ASSUMPTION THAT THE EXISTING ALLOWABLE SOIL PRESSURE IS 2,000 PSF OR BETTER. IF SOIL CONDITIONS DO NOT EQUAL OR EXCEED 2,000 PSF CONTACT ARCHITECT. 3 CONCRETE STOOP 4 CONCRETE STEP 5 GARAGE SLAB SHALL SLOPE TOWARDS GARAGE DOORS (1% MAX. SLOPE). 4" THICK POURED CONC.; 4,000 PSI OVER 4" PEA GRAVEL OR GRANULAR COMPACTED BASE AND 10 MIL MOISTURE BARRIER. CONCRETE SHALL BE REINFORCED WITH 6X6 10/10 W.W.F.. 6 4" THICK POURED CONC.; 4,000 PSI OVER 4" PEA GRAVEL OR GRANULAR COMPACTED BASE AND 10 MIL MOISTURE BARRIER. CONCRETE SHALL BE REINFORCED WITH 6X6 10/10 W.W.F.. 7 OPTIONAL; THICKENED SLAB IF ROOF IS STICK FRAMED IN LIEU OF TRUSSES. SEE DETAIL 7/S0 3/4" = 1'-0"6 FOUNDATION SECTION DETAIL 3/4" = 1'-0"3 FOUNDATION SECTION AT GARAGE SLAB 3/4" = 1'-0"5 FOUNDATION DETAIL THRU HOUSE AND GARAGE 3/4" = 1'-0"4 FOUNDATION DETAIL THRU GARAGE OPENING 3/4" = 1'-0" 2 FOUNDATION DETAIL AT MAN DOOR 3/4" = 1'-0"7 THICKENED SLAB No. Description Date 06/28/21