HomeMy WebLinkAboutS framingNOTE: THE FLOOR/ WALL FRAMING PLAN ONLY SHOWS GENERAL INTENT AND DIRECTION OF FRAMING MEMBERS. CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ALL FINAL FRAMING CONNECTIONS, FRAMING ASSEMBLIES, BRACING AND SHORING. 12x82x82x82x82x82x82x82x82x82x82x82x82x82x82x82x82x82 3 4 5 TYP 3 4 6 7 8 9 9 10 11 5K 5K 12 12 12 12 12 Scale Date Drawn By Checked By Project Number MEDLEY CREATIONS, INC. CARMEL, IN 46032 40 PINE VALLEY DR ARCHITECTURAL ARCHITECTURAL DESIGN STUDIO 5761 RAVINE RD. INDPLS., IN 46220 (317) 694-3359 c (317) 731-5760 f medleycreations@comcast.net www.medleycreationsinc.com M ARCHITECT'S SEAL RANDY GILLASPIE NEW LIVING AREA FLOOR PLAN WITH OWNER'S REQUESTED REVISIONS 4-26-2021 1/4" = 1'-0" S1 KOJ KOJ 5-25-2021 0321-0100 FRAMING PLAN 1/4" = 1'-0"1 FRAMING PLAN PLAN NOTES FOR S1 1 OPTIONAL; ROOF TRUSSES @ 24" O.C.. DESIGN LOADS FOR TRUSS: 25psf SNOW LOAD 10psf DEAD LOAD 100mph WIND SPEED TRUSS DESIGN DRAWING: TO BE PROVIDED BY TRUSS MANUFACTURER AND PREPARED IN COMPLIANCE WITH SECTION R502.11.1. CONTRACTOR SHALL PROVIDE INFORMATION TO THE BUILDING OFFICIALS AND RECEIVE APPROVAL PRIOR TO INSTALLATION. TRUSS DESIGN DRAWINGS SHALL ALSO BE PROVIDED WITH THE SHIPMENT OF TRUSSES DELIVERED TO THE JOB SITE. TRUSS DESIGN DRAWINGS SHALL INCLUDE, AT A MINIMUM, THE INFORMATION SPECIFIED BELOW: 1 SLOPE OR DEPTH, SPAN, AND SPACING 2 LOCATION OF ALL JOINTS 3 REQUIRED BEARING WIDTHS 4 DESIGN LOADS AS APPLICABLE. 4.1 TOP CHORD LIVE LOAD (INCLUDING SNOW LOADS) 4.2 TOP CHORD DEAD LOAD 4.3 BOTTOM CHORD LIVE LOAD 4.4 BOTTOM CHORD DEAD LOAD 4.5 CONCENTRATED LOADS AND THEIR POINTS OF APPLICATION 4.6 CONTROLLING WIND AND EARTHQUAKE 5 ADJUSTMENTS TO LUMBER AND JOINT CONNECTOR DESIGN FOR CONDITIONS OF USE 6 EACH REACTION FORCE AND DIRECTION 7 JOINT CONNECTOR TYPE AND DESCRIPTION (E.G., SIZE, THICKNESS OR GAUGE); AND THE DIMENSIONED LOCATION OF EACH JOINT CONNECTOR EXCEPT WHERE SYMMETRICALLY LOCATED RELATIVE TO THE JOINT INTERFACE 8 LUMBER SIZE, SPECIES AND GRADE FOR EACH MEMBER 9 CONNECTION REQUIREMENTS FOR: 9.1 TRUSS-TO-TRUSS GIRDER 9.2 TRUSS PLY-TO-PLY 9.3 FIELD SPLICES 10 CALCULATED DEFLECTION RATIO AND/OR MAXIMUM DESCRIPTION FOR LIVE AND TOTAL LOAD 11 MAXIMUM AXIAL COMPRESSION FORCES IN THE TRUSS MEMBERS TO ENABLE THE CONTRACTOR TO PROVIDE THE PROPER CONNECTIONS AND ANCHORAGE OF THE PERMANENT CONTINUOUS LATERAL BRACING. FORCES SHALL BE SHOWN ON THE TRUSS DRAWINGS OR ON SUPPLEMENTAL DOCUMENTS 12 REQUIRED TRUSS MEMBER BRACING LOCATION 2 CONTRACTOR SHALL CONFIRM FINAL ORIENTATION OF NEW FLOOR JOISTS. 2X8 FLOOR JOIST @ 16" O.C. WITH CROSS BRIDGING. FLOOR JOIST WAS DESIGNED FROM THE FOLLOWING: 40psf LIVE LOAD 20psf DEAD LOAD APPROVED SPECIES AND GRADE DOUGLAS FIR-LARCH -SS, #1 & #2 HEM-FIR -SS, #1 & #2 SOUTHERN PINE -SS, #1 & #2 SPRUCE-PINE FIR -SS, #1, & #2 3 TREATED SLEEPER SILL PLATE; 2X4 EXPANSION BOLTED TO EXISTING CONCRETE SLAB AND LAID OVER LAYER OF SILL SEAL FOAM INSULATION 4 2X8 HEADER FASTENED TO EXISTING WALL STUDS 5 TYPICAL, TREATED 2X8 BLOCKING PLATE FASTENED TO EXISTING CONCRETE SLAB AND FLOOR JOISTS 6 (2) 1 3/4" X 9 1/4" LVL BEAMS 7 (2) 1 3/4" X 14" LVL BEAMS 8 (2) 2X8 LINTEL 9 OPTIONAL; 2X6 ROOF FRAMING @ 16" O.C. WITH 2X8 RIDGE BOARD 10 (3) 1 3/4" X 14" LVL BEAMS. LVL IS DESIGNED FOR 10# D.L. + 20# L.L. 11 PROVIDE PULL DOWN STAIR ACCESS. FIELD VERIFY FINAL LOCATION 12 (2) 2X6 LINTEL WITH EACH END SUPPORTED WITH (1) JACK STUD No. Description Date 06/28/21