HomeMy WebLinkAboutA122 4TH FL REFLECTED CEILINGSNSNSNS
NSNELNELNELNELELELELDESCRIPTIONDATE
ISSUE
04.05.21 REVIEW SET
04.13.21 PERMIT SET
04.28.21 UPDATED SET
REVISONS
DESCRIPTIONMARK DATE DB 3 MERIDIAN PLAZAKINETIC ADVANTAGE1ST & 4TH FLOORS10333 N. MERIDIAN STREET - CARMEL, INDIANA 462902020.296
AS AS
N0 2' 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR
REFLECTED
CEILING PLAN
A122REFLECTED CEILING PLAN
AREA NOT IN CONTRACT
AREA OF WORK
PLAN NOTES
CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT
THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
IN AREA TO BE EXPOSED TO DECK, REPLACE LOW PRESSURE
SUPPLY BRANCH LINE DUCT AND WITH NEW RIGID SPIRAL DUCT
AND RECTANGULAR SUPPLY DIFFUSERS AS REQUIRED. CLEAN AND
PREPARE FOR DRYFALL PAINT (PT_). AS SPECIFIED, PAINT EXISTING
EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING,
JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS FIREPROOFING,
ETC. IN ACCORDANCE WITH NFPA 13 6.3.8.
CEILING TO BE PAINTED (PT_). LIGHTS TO BE SWITCHED OUT FOR
NEW 2'x4', LED, BUILDING STANDARD DIRECT/INDIRECT.
NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET.
SWITCH, PROJECTOR
SCREEN
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
NP
ND
N
N3
P
D
3
EXIT LIGHT FIXTURE
LIGHT FIXTURE,
PENDANT
RECESSED LIGHT
FIXTURE
LIGHT FIXTURE, 2'x2', LED,
BUILDING STANDARD
DIRECT/INDIRECT
LIGHT FIXTURE, 2'x4', LED,
BUILDING STANDARD
DIRECT/INDIRECT
RELOCATED DIFFUSER,
LAY-IN, 4"x4'
RELOCATED DIFFUSER,
LAY-IN, 1'x4'
RELOCATED DIFFUSER,
LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 2'x2'
CEILING GRID,
SUSPENDED, 2'x4'
NIGHT LIGHT
NEW OR RELOCATED EXISTING TO REMAIN
LIGHT FIXTURE,
PENDANT
EXIT LIGHT FIXTURE
SWITCH, PROJECTOR
SCREEN
LIGHT CIRCUIT
LIGHT SWITCH, DIMMER
LIGHT SWITCH, 3-WAY
LIGHT SWITCH
CEILING GRID,
SUSPENDED, 2'x2'
CEILING GRID,
SUSPENDED, 2'x4'
DIFFUSER, LAY-IN, 4"x4'
DIFFUSER, LAY-IN, 1'x4'
DIFFUSER, LAY-IN, 2'x2'
CEILING GRID,
SUSPENDED, 4'x4' TEES
TO COMPLETE GRID
CEILING GRID,
SUSPENDED, 4'x4'
GYPSUM BOARD
CEILING
LIGHT FIXTURE, 2'x2',
FLUORESCENT, PARABOLIC
LIGHT FIXTURE, 2'x4',
FLUORESCENT, PARABOLIC
LEGEND
RECESSED LIGHT
FIXTURE
EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT
FIXTURE
EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2'
GYPSUM BOARD
CEILING
SWITCH, GARBAGE
DISPOSAL (ABOVE
COUNTERTOP)
NG G SWITCH, GARBAGE
DISPOSAL
EXPOSED TO DECK
SWITCH, EXHAUST FANNE E SWITCH, EXHAUST FAN
1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED.
EXISTING GRID IS 2x2 AT 10'-0" ON 1ST FLOOR AND 8'-5" ON 4TH
FLOOR A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY
DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO
MATCH EXISTING.
2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM
DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE
CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE
UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE
REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
NEED TO BE MET.
5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE
POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON
PLAN.
7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
GENERAL NOTES
1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING
H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE
SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
MECHANICAL NOTES
A122
1
MECHANICAL DIFFUSER RELOCATION
A122
1
*REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
RELOCATE DIFFUSERS &
FLEXDUCT IF REQUIRED
EXISTING VAV BOXES/HEAT
PUMP AND MAIN SUPPLY
DUCTS TO REMAIN
VAV/
HEAT PUMP
4TH FLOOR SOUTH WING
NORTH WINGSOUTH WING