HomeMy WebLinkAboutA123 4TH FL N WING REFLECTED CEILINGEL ELELELELELELELELELELELELELELSN S NDESCRIPTIONDATE ISSUE 04.05.21 REVIEW SET 04.13.21 PERMIT SET 04.28.21 UPDATED SET REVISONS DESCRIPTIONMARK DATE DB 3 MERIDIAN PLAZAKINETIC ADVANTAGE1ST & 4TH FLOORS10333 N. MERIDIAN STREET - CARMEL, INDIANA 462902020.296 AS AS N0 2' 4' 8' 16' THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR REFLECTED CEILING PLAN A123REFLECTED CEILING PLAN AREA NOT IN CONTRACT AREA OF WORK PLAN NOTES CONTROL OPEN OFFICE AREA LIGHTING WITH 3-WAY SWITCH AT THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED. IN AREA TO BE EXPOSED TO DECK, REPLACE LOW PRESSURE SUPPLY BRANCH LINE DUCT AND WITH NEW RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY DIFFUSERS AS REQUIRED. CLEAN AND PREPARE FOR DRYFALL PAINT (PT_). AS SPECIFIED, PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS FIREPROOFING, ETC. IN ACCORDANCE WITH NFPA 13 6.3.8. CEILING TO BE PAINTED (PT_). LIGHTS TO BE SWITCHED OUT FOR NEW 2'x4', LED, BUILDING STANDARD DIRECT/INDIRECT. NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET. SWITCH, PROJECTOR SCREEN LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH NP ND N N3 P D 3 EXIT LIGHT FIXTURE LIGHT FIXTURE, PENDANT RECESSED LIGHT FIXTURE LIGHT FIXTURE, 2'x2', LED, BUILDING STANDARD DIRECT/INDIRECT LIGHT FIXTURE, 2'x4', LED, BUILDING STANDARD DIRECT/INDIRECT RELOCATED DIFFUSER, LAY-IN, 4"x4' RELOCATED DIFFUSER, LAY-IN, 1'x4' RELOCATED DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 2'x2' CEILING GRID, SUSPENDED, 2'x4' NIGHT LIGHT NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, PENDANT EXIT LIGHT FIXTURE SWITCH, PROJECTOR SCREEN LIGHT CIRCUIT LIGHT SWITCH, DIMMER LIGHT SWITCH, 3-WAY LIGHT SWITCH CEILING GRID, SUSPENDED, 2'x2' CEILING GRID, SUSPENDED, 2'x4' DIFFUSER, LAY-IN, 4"x4' DIFFUSER, LAY-IN, 1'x4' DIFFUSER, LAY-IN, 2'x2' CEILING GRID, SUSPENDED, 4'x4' TEES TO COMPLETE GRID CEILING GRID, SUSPENDED, 4'x4' GYPSUM BOARD CEILING LIGHT FIXTURE, 2'x2', FLUORESCENT, PARABOLIC LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC LEGEND RECESSED LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2' GYPSUM BOARD CEILING SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) NG G SWITCH, GARBAGE DISPOSAL EXPOSED TO DECK SWITCH, EXHAUST FANNE E SWITCH, EXHAUST FAN 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 10'-0" ON 1ST FLOOR AND 8'-5" ON 4TH FLOOR A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI-SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS.  ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. GENERAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED.  ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED;  MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. MECHANICAL NOTES MECHANICAL DIFFUSER RELOCATION A122 1 *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED EXISTING VAV BOXES/HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN VAV/ HEAT PUMP 4TH FLOOR NORTH WING NORTH WINGSOUTH WING 06/29/21