HomeMy WebLinkAboutE112 4TH FL ELEC PLANOFFICE
412
RR
403
RR
404
TECH.
CENTER
409
OFFICE
410
OFFICE
411
OFFICE
414
OFFICE
413
OFFICE
415
OFFICE
416
OFFICE
417
OFFICE
418
OFFICE
407
OFFICE
406
STORAGE
408
OFFICE
446
OFFICE
445
OPEN OFFICE
442
OPEN OFFICE
405
ENTRY
441
COFFEE
443
OPEN OFFICE
448
OFFICE
444 REFRIGB
Y
TE
N
A
N
T
OFFICE
447 JJ JJ+42"+42"
GFCI GFCI
+
4
4
"
+
4
4
"+44"+44"+44" +44"+44"+44"+44"+44"+44"+24"GFCI
J
J
+44"+50"+44"+50"DEDDESCRIPTIONDATE
ISSUE
04.05.21 REVIEW SET
04.13.21 PERMIT SET
04.28.21 UPDATED SET
REVISONS
DESCRIPTIONMARK DATE DB 3 MERIDIAN PLAZAKINETIC ADVANTAGE1ST & 4TH FLOORS10333 N. MERIDIAN STREET - CARMEL, INDIANA 462902020.296
AS AS
N0 2' 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR
ELECTRICAL PLAN
E112ELECTRICAL PLAN
AREA NOT IN CONTRACT
AREA OF WORK
LEGEND
DED
POWER OUTLET, DUPLEX
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
POWER OUTLET, DUPLEX
POWER OUTLET,
QUADRUPLEX
JUNCTION BOX
BOX, BLANK COVER PLATE
BOX, OPEN
BOX, BLANK COVER PLATE
BOX, OPEN
POWER AND DATA POLE
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
FLOOR BOX WITH POWER
AND DATA, FLUSH
MOUNTED
FLOOR BOX WITH
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DEDICATED CIRCUIT
DATA/COMMUNICATION
OUTLET (PROVIDE BOX
AND PULL STRING ONLY)
DATA/COMMUNICATION
OUTLET
GFCI GROUND FAULT CIRCUIT
INTERRUPT OUTLET
HEIGHT OF ELECTRICAL
OR DATA DEVICE
CEILING MOUNTED
JUNCTION BOX
CEILING MOUNTED
JUNCTION BOX
J
B
O
J
+42"
PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S
FURNITURE VENDOR.
CONFIRM ALL IT REQUIREMENTS WITH TENANT.
PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET
INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT
24" A.F.F.
PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE FOR
TENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION
WITH TENANT'S FURNITURE VENDOR. POWER POLE BY FURNITURE
VENDOR.
PROVIDE POWER AS REQUIRED AT DOOR FOR CARD READER
(CARD READER BY TENANT). COORDINATE WITH TENANT'S
SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE
DETAILS.
PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT.
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
PLAN NOTES
1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. CONTRACTOR TO PROVIDE GFCI OUTLET FOR WATER HEATER AND
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
5. ELECTRICAL WORK IS LIMITED TO A DESIGN-BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
GENERAL NOTES
PROVIDE JUNCTION BOX
ABOVE CEILING FOR
POWER POLE
CONNECTION. POWER
POLE BY OTHERS.
4TH FLOOR SOUTH WING
NORTH WINGSOUTH WING
06/29/21