HomeMy WebLinkAboutA111 1ST FL ARCH FLOOR PLANWALL
THICKNESS
PRE-FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
TYPICAL WALL TYPE
METAL STUD
EXISTING WINDOW
MULLION
EQUAL
OPEN OFFICE
103
STG.
102
CHAT
101
OFFICE
104
SCANNING
OPEN OFFICE
108
ENTRY
110
IT
111
OFFICE
105
VAULT
109
REFRIGBYTENANTCOFFEE
107
CHAT
10610'-5"11'-43
4"10'-43 4"10'-43 4"4'-21 4 "FEFE12'-91
4"DESCRIPTIONDATE
ISSUE
04.05.21 REVIEW SET
04.13.21 PERMIT SET
04.28.21 UPDATED SET
REVISONS
DESCRIPTIONMARK DATE DB 3 MERIDIAN PLAZAKINETIC ADVANTAGE1ST & 4TH FLOORS10333 N. MERIDIAN STREET - CARMEL, INDIANA 462902020.296
AS AS
N0 2' 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER
DRAWN BYPROJ. MGR
ARCHITECTURAL
FLOOR PLAN
A111
ARCHITECTURAL PLAN
AREA NOT IN CONTRACT
AREA OF WORK
WALL
DOOR AND FRAME
(SEE DOOR SCHEDULE)
NEW CONSTRUCTION EXISTING TO REMAIN
WALL
DOOR AND FRAME
WINDOW / SIDELIGHTWINDOW / SIDELIGHT
ARCHITECTURAL LEGEND
PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL
DEMISING WALL TO DECK WITH INSULATION
358" METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W1 WALL WITH INSULATION
358 " METAL STUDS AT 16" O.C.;
ONE LAYER OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
W2
WALL TYPES
W1
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE
RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR
SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
PLAN NOTES
GENERAL NOTES
NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET.
1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT
OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5
DRYWALL FINISH. REFER TO MANUFACTURER
RECOMMENDATIONS.
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3
4", PAINTED WITH FIRE
RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
NEW FIRE EXTINGUISHER AND BRUSHED ALUMINUM CABINET TO BE
PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE
EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED COAT HOOKS; COORDINATE EXACT
LOCATION WITH TENANT.
PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
_______________________________________________________________
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL
AUTOMATIC SHUTOFF VALVES AS REQUIRED.
PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM
LOCATION WITH TENANT.
2-HOUR WALL TO DECK WITH INSULATION
358" METAL STUDS AT 16" O.C.;
TWO LAYERS OF 58" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF DECK;
FIBERGLASS BATT SOUND INSULATION INSIDE
WALL
W3
1ST FLOOR
NOT TO SCALE
WALL AT MULLION DETAIL
A111
1
A211
2
W3
W3
W3
W3
06/29/21