HomeMy WebLinkAboutA111 1ST FL ARCH FLOOR PLANWALL THICKNESS PRE-FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT TYPICAL WALL TYPE METAL STUD EXISTING WINDOW MULLION EQUAL OPEN OFFICE 103 STG. 102 CHAT 101 OFFICE 104 SCANNING OPEN OFFICE 108 ENTRY 110 IT 111 OFFICE 105 VAULT 109 REFRIGBYTENANTCOFFEE 107 CHAT 10610'-5"11'-43 4"10'-43 4"10'-43 4"4'-21 4 "FEFE12'-91 4"DESCRIPTIONDATE ISSUE 04.05.21 REVIEW SET 04.13.21 PERMIT SET 04.28.21 UPDATED SET REVISONS DESCRIPTIONMARK DATE DB 3 MERIDIAN PLAZAKINETIC ADVANTAGE1ST & 4TH FLOORS10333 N. MERIDIAN STREET - CARMEL, INDIANA 462902020.296 AS AS N0 2' 4' 8' 16' THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN.450 E. 96th StreetIndianapolis, IN 46240p: 317.387.1700www.schottdesign.comPROJECT NUMBER DRAWN BYPROJ. MGR ARCHITECTURAL FLOOR PLAN A111 ARCHITECTURAL PLAN AREA NOT IN CONTRACT AREA OF WORK WALL DOOR AND FRAME (SEE DOOR SCHEDULE) NEW CONSTRUCTION EXISTING TO REMAIN WALL DOOR AND FRAME WINDOW / SIDELIGHTWINDOW / SIDELIGHT ARCHITECTURAL LEGEND PARTIAL HEIGHT WALL PARTIAL HEIGHT WALL DEMISING WALL TO DECK WITH INSULATION 358" METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W1 WALL WITH INSULATION 358 " METAL STUDS AT 16" O.C.; ONE LAYER OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING W2 WALL TYPES W1 NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. PLAN NOTES GENERAL NOTES NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET. 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'x3 4", PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW FIRE EXTINGUISHER AND BRUSHED ALUMINUM CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED COAT HOOKS; COORDINATE EXACT LOCATION WITH TENANT. PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. _______________________________________________________________ PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. CONTRACTOR TO INSTALL AUTOMATIC SHUTOFF VALVES AS REQUIRED. PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. 2-HOUR WALL TO DECK WITH INSULATION 358" METAL STUDS AT 16" O.C.; TWO LAYERS OF 58" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS BATT SOUND INSULATION INSIDE WALL W3 1ST FLOOR NOT TO SCALE WALL AT MULLION DETAIL A111 1 A211 2 W3 W3 W3 W3 06/29/21