Loading...
HomeMy WebLinkAboutI46097735.33_Estates_at_Towne_Meadow16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). May 13,2021 Johnson, Andrew Pages or sheets covered by this seal: I46097735 thru I46097781 My license renewal date for the state of Indiana is July 31, 2022. 33_Estates_at_Towne_Meadow 33 Estates at Towne Meadow IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss GE01 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097735 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:07 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-4s6_4dyIp3i6nG1qQz4hIslh7m1_r0n53CJdgIzH8OQ Scale = 1:34.4 Sheet FrontFull Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 3x4 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 10-2-010-2-0 -1-0-0 1-0-0 5-1-0 5-1-0 10-2-0 5-1-0 11-2-0 1-0-0 1-3-05-5-131-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.04 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 -0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 112 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 10-2-0. (lb) - Max Horz 16=-118(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Corner(3R) 2-0-0 to 8-2-0, Corner(3E) 8-2-0 to 11-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15, 12, 11. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss GE02 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097736 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:09 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-1FElVJzZLhzq0ZBDYO69OHq?gaisJwhOXWoklBzH8OO Scale = 1:87.2 Sheet Front Full Sheathing 1 Ply 7/16OSB8 12 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 3x4 3x4 3x6 3x6 3x6 3x4 3x4 3x6 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 37-11-037-11-0 -0-11-0 0-11-0 16-4-8 16-4-8 21-6-8 5-2-0 37-11-0 16-4-8 38-10-0 0-11-0 1-1-012-0-01-1-012-0-08.00 12 Plate Offsets (X,Y)-- [12:0-4-8,0-2-8], [15:0-4-4,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.19 0.08 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.01 (loc) 25 25 26 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 772 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 *Except* 15-35,14-36,13-37,11-38,16-34: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 12-15. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-35, 14-36, 13-37, 11-38, 10-40, 9-41, 16-34, 17-32 REACTIONS.All bearings 37-11-0. (lb) - Max Horz 47=-230(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 26, 36, 40, 41, 42, 43, 44, 45, 34, 32, 31, 30, 29, 28, 27 except 47=-137(LC 6), 46=-129(LC 10) Max Grav All reactions 250 lb or less at joint(s) 47, 26, 35, 36, 37, 38, 40, 41, 42, 43, 44, 45, 46, 34, 32, 31, 30, 29, 28, 27 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 10-11=-169/278, 12-13=-151/251, 13-14=-151/251, 14-15=-151/251, 15-16=-175/286 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 13-4-8, Corner(3R) 13-4-8 to 24-6-8, Exterior(2N) 24-6-8 to 35-6-8, Corner(3E) 35-6-8 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 26, 36, 40, 41, 42, 43, 44, 45, 34, 32, 31, 30, 29, 28, 27 except (jt=lb) 47=137, 46=129. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss GE03 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097737 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:11 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-zdMVw_?ptIDYGtLcfp9dTiwLlNOFnqBh_qHrp3zH8OM Scale = 1:86.1 Sheet Back Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 3x4 3x4 3x6 3x6 3x6 3x4 3x4 3x6 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x6 37-7-837-7-8 -0-11-0 0-11-0 16-4-8 16-4-8 21-6-8 5-2-0 37-7-8 16-1-0 1-1-012-0-01-3-512-0-08.00 12 Plate Offsets (X,Y)-- [12:0-4-8,0-2-8], [15:0-4-4,0-2-4], [25:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.22 0.08 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 0.00 (loc) 1 1 25 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 769 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 24-25: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 15-34,14-35,13-36,11-37,16-33: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 12-15. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-34, 14-35, 13-36, 11-37, 10-39, 9-40, 16-33, 17-31 REACTIONS.All bearings 37-7-8. (lb) - Max Horz 46=226(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 25, 35, 39, 40, 41, 42, 43, 44, 33, 31, 30, 29, 28, 27, 26 except 46=-167(LC 6), 45=-137(LC 7) Max Grav All reactions 250 lb or less at joint(s) 25, 34, 35, 36, 37, 39, 40, 41, 42, 43, 44, 45, 33, 31, 30, 29, 28, 27, 26 except 46=256(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 10-11=-182/284, 11-12=-167/253, 12-13=-161/257, 13-14=-161/257, 14-15=-161/256, 15-16=-187/292, 16-17=-161/252 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 13-4-8, Corner(3R) 13-4-8 to 24-6-8, Exterior(2N) 24-6-8 to 34-6-4, Corner(3E) 34-6-4 to 37-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 35, 39, 40, 41, 42, 43, 44, 33, 31, 30, 29, 28, 27, 26 except (jt=lb) 46=167, 45=137. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss GE04 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097738 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:12 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-Rqwt8K0RecLPt1woDXgs?vSYFnlAWHArDU1OMVzH8OL Scale = 1:35.0 Sheet FrontFull Sheathing1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 3x4 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 11-11-011-11-0 -0-11-0 0-11-0 5-11-8 5-11-8 11-11-0 5-11-8 12-10-0 0-11-0 1-2-05-7-101-2-09.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.11 0.04 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 9 9 10 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 129 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 11-11-0. (lb) - Max Horz 16=-117(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11 Max Grav All reactions 250 lb or less at joint(s) 16, 10, 13, 14, 15, 12, 11 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 1-11-8, Exterior(2N) 1-11-8 to 2-11-8, Corner(3R) 2-11-8 to 8-11-8, Exterior(2N) 8-11-8 to 9-10-0, Corner(3E) 9-10-0 to 12-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15, 12, 11. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss GE05 Truss Type Monopitch Supported Gable Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097739 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:13 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-v0UFLg03PvTGVBV_nEB5Y7?hIB2bFmQ_S8myuyzH8OK Scale = 1:13.3 1 2 3 5 4 3x6 3x4 3x4 -1-0-0 1-0-0 4-9-8 4-9-8 0-8-82-1-43.50 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.22 0.16 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.01 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=4-9-8, 4=4-9-8 Max Horz 5=56(LC 7) Max Uplift 5=-37(LC 6), 4=-12(LC 10) Max Grav 5=259(LC 1), 4=173(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss GE06 Truss Type Monopitch Supported Gable Qty 2 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097740 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:14 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-NC1dY01hADb77K4BLyiK5KYtqbPf_Dg7gnWVQOzH8OJ Scale = 1:13.2 1 2 3 5 4 3x6 3x4 3x4 -1-0-0 1-0-0 4-0-0 4-0-0 0-9-02-1-04.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.17 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=4-0-0, 4=4-0-0 Max Horz 5=57(LC 7) Max Uplift 5=-36(LC 6), 4=-11(LC 10) Max Grav 5=229(LC 1), 4=139(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss GE07 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097741 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:15 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-rPb0mM2KxXj_lUeNufDZdY43D?mfjdzHvRF2yqzH8OI Scale = 1:44.8 Sheet Front Full Sheathing 1 Ply 7/16OSB8 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 3x4 3x4 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 13-6-013-6-0 -1-0-0 1-0-0 6-9-0 6-9-0 13-6-0 6-9-0 14-6-0 1-0-0 1-3-06-10-81-3-010.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.05 0.25 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.01 0.00 (loc) 11 11 12 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 170 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 13-6-0. (lb) - Max Horz 20=-143(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 17, 18, 15, 14 except 20=-139(LC 6), 12=-117(LC 7), 19=-131(LC 7), 13=-116(LC 6) Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -1-0-0 to 2-0-0, Exterior(2N) 2-0-0 to 3-9-0, Corner(3R) 3-9-0 to 9-9-0, Exterior(2N) 9-9-0 to 11-6-0, Corner(3E) 11-6-0 to 14-6-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 15, 14 except (jt=lb) 20=139, 12=117, 19=131, 13=116. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss J01 Truss Type Jack-Open Qty 15 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097742 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:16 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-Jb9Ozi3yiqrrMeDZSMkoAldE2O65S7AQ85?cVHzH8OH Scale = 1:11.7 1 2 5 3 43x4 3x4 1-0-01-0-0 -1-0-0 1-0-0 1-0-0 1-0-0 1-1-01-9-00-5-31-3-131-9-08.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.12 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 5 5 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 5 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 3=Mechanical, 4=Mechanical Max Horz 5=30(LC 7) Max Uplift 3=-13(LC 10), 4=-7(LC 10) Max Grav 5=143(LC 1), 3=5(LC 6), 4=16(LC 8) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss M01 Truss Type Monopitch Qty 5 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097743 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:17 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-onjmB23aT8zi_ool04G1iz9PToSJBaQaMlk91jzH8OG Scale = 1:10.4 1 2 3 5 4 3x4 3x6 3x4 2-10-02-10-0 -1-0-0 1-0-0 2-10-0 2-10-0 0-8-61-6-41-2-120-3-81-6-43.50 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 -0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 9 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-10-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=39(LC 7) Max Uplift 5=-37(LC 6), 4=-5(LC 10) Max Grav 5=186(LC 1), 4=86(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss M02 Truss Type Monopitch Qty 4 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097744 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:17 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-onjmB23aT8zi_ool04G1iz9NZoQhBaQaMlk91jzH8OG Scale = 1:13.3 1 2 3 5 4 3x4 3x6 3x4 4-9-84-9-8 -1-0-0 1-0-0 4-9-8 4-9-8 0-8-82-1-41-9-120-3-82-1-43.50 12 Plate Offsets (X,Y)-- [4:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.20 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.03 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=0-3-8, 4=0-1-8 Max Horz 5=56(LC 7) Max Uplift 5=-37(LC 6), 4=-12(LC 10) Max Grav 5=258(LC 1), 4=171(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss M03 Truss Type Monopitch Qty 8 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097745 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:18 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-GzH8OO4CDS5YcyNyannGFAiZ9Cnbw1fjbPUjZ9zH8OF Scale = 1:13.2 1 2 3 5 4 3x4 3x4 3x6 4-0-04-0-0 -1-0-0 1-0-0 4-0-0 4-0-0 0-9-02-1-04.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 0.00 (loc) 4-5 4-5 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 5=0-3-8 Max Horz 5=57(LC 7) Max Uplift 4=-11(LC 10), 5=-36(LC 6) Max Grav 4=139(LC 1), 5=229(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss MG01 Truss Type Monopitch Girder Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097746 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:19 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-kArWck5q_lDPD6y87VIVoOFhHc_MfUvsq3DG5czH8OE Scale = 1:13.3 1 2 345 3x4 3x4 3x8 3x4 4-9-84-9-8 4-9-8 4-9-8 0-8-82-1-41-7-120-5-82-1-43.50 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-3], [3:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.38 0.58 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.07 -0.00 (loc) 1-3 1-3 3 l/defl >999 >802 n/a L/d 240 180 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-9-8 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=0-1-8 Max Horz 1=50(LC 5) Max Grav 1=607(LC 1), 3=496(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 372 lb down at 1-0-12, and 371 lb down at 3-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 1-3=-20 Concentrated Loads (lb) Vert: 4=-372(B) 5=-371(B) May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss MG02 Truss Type Monopitch Girder Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097747 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:19 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-kArWck5q_lDPD6y87VIVoOFjfc3YfUvsq3DG5czH8OE Scale = 1:11.9 1 2 34 3x4 3x4 3x4 3-10-03-10-0 3-10-0 3-10-0 0-8-61-9-121-4-40-5-81-9-123.50 12 Plate Offsets (X,Y)-- [3:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.22 0.31 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.02 -0.00 (loc) 1-3 1-3 3 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 3=0-1-8 Max Horz 1=42(LC 5) Max Grav 1=283(LC 1), 3=316(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 315 lb down at 2-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 1-3=-20 Concentrated Loads (lb) Vert: 4=-315(F) May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss PB01 Truss Type GABLE Qty 26 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097748 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:20 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-CMPvp36Sl3LGrFXKhCpkKbnxB0RcOx903jzpe2zH8OD Scale = 1:13.1 2 3 4 1 5 3x4 3x4 3x4 5-2-05-2-0 2-7-0 2-7-0 5-2-0 2-7-0 -0-0-41-8-71-8-110-1-00-1-88.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-2-0. (lb) - Max Horz 1=27(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 2, 4 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss PB02 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097749 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:21 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-gYzH0P74WNT7TP6XFwKztpK6yPpY7Nn9HNiNAUzH8OC Scale = 1:23.7 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 3 4 5 6 10 9 8 1 11 12 7 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 8-7-68-7-6 4-3-11 4-3-11 8-7-6 4-3-11 3-7-10-1-40-1-810.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 6 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 54 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-7-6. (lb) - Max Horz 1=61(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 2, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6, 9, 10, 8 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-2-14 to 3-2-14, Corner(3R) 3-2-14 to 5-4-8, Corner(3E) 5-4-8 to 8-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 2, 10, 8. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss PB03 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097750 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:23 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-cx41R58L2_krijGvMLMRyEPP8DUgbHOSlhBUENzH8OA Scale = 1:23.7 2 3 4 6 1 7 8 5 4x6 3x4 3x4 2x4 8-7-68-7-6 4-3-11 4-3-11 8-7-6 4-3-11 3-7-10-1-40-1-810.00 12 Plate Offsets (X,Y)-- [2:0-1-8,0-1-8], [4:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.19 0.11 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 23 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-7-6. (lb) - Max Horz 1=-61(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 1=-263(LC 17), 5=-232(LC 18), 2=-191(LC 10), 4=-171(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 6 except 2=463(LC 17), 4=441(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-2-14 to 3-2-14, Corner(3R) 3-2-14 to 5-4-8, Corner(3E) 5-4-8 to 8-4-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 263 lb uplift at joint 1, 232 lb uplift at joint 5, 191 lb uplift at joint 2 and 171 lb uplift at joint 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss PBE01 Truss Type GABLE Qty 2 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097751 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:23 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-cx41R58L2_krijGvMLMRyEPSQDTJbHvSlhBUENzH8OA Scale = 1:13.1 Sheet Front Full Sheathing 1 Ply 7/16OSB8 2 3 4 1 5 3x4 3x4 3x4 5-2-05-2-0 2-7-0 2-7-0 5-2-0 2-7-0 -0-0-41-8-71-8-110-1-00-1-88.00 12 Plate Offsets (X,Y)-- [3:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.05 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 19 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-2-0. (lb) - Max Horz 1=27(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 2, 4 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 2, 4 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 2, 4. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T01 Truss Type Common Qty 4 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097752 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:24 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-47ePfR9zpIsiKtr6w2ugVRyU9dcwKX3czLx1npzH8O9 Scale = 1:59.9 1 2 3 4 5 6 7 11 10 9 8 12 13 14 15 16 17 4x6 3x16 MT18HS 3x8 3x4 3x4 3x6 5x6 5x6 3x6 10-5-810-5-8 20-11-010-5-8 -1-0-0 1-0-0 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 20-11-0 5-4-0 21-11-0 1-0-0 1-3-09-11-91-3-010.00 12 Plate Offsets (X,Y)-- [8:Edge,0-2-4], [11:Edge,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.62 1.00 0.84 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.33 -0.55 0.02 (loc) 8-9 8-9 8 l/defl >761 >448 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 91 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-11,6-8: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)11=0-3-8, 8=0-3-8 Max Horz 11=-198(LC 8) Max Grav 11=994(LC 17), 8=994(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-429/87, 3-4=-820/90, 4-5=-820/90, 5-6=-429/87, 2-11=-428/92, 6-8=-428/91 BOT CHORD 9-11=-37/761, 8-9=0/679 WEBS 4-9=-26/669, 3-11=-641/4, 5-8=-640/4 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 18-11-0, Exterior(2E) 18-11-0 to 21-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T02 Truss Type Common Qty 2 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097753 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:25 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-ZKCosnAbab_Zx1PIUlPv1fVag1zG32ilC?gaJFzH8O8 Scale = 1:59.9 1 2 3 4 5 9 8 7 6 10 11 12 13 4x6 5x6 3x8 MT18HS 3x4 3x6 5x6 3x4 3x8 10-5-810-5-8 18-6-08-0-8 -1-0-0 1-0-0 5-4-0 5-4-0 10-5-8 5-1-8 18-6-0 8-0-8 1-3-09-11-93-3-310.00 12 Plate Offsets (X,Y)-- [5:Edge,0-1-0], [9:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.89 0.87 0.62 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.41 -0.68 0.01 (loc) 7-9 7-9 6 l/defl >532 >322 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 80 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-9,5-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Structural wood sheathing directly applied or 9-5-9 oc bracing. REACTIONS. (size)9=0-3-8, 6=Mechanical Max Horz 9=211(LC 7) Max Grav 9=879(LC 17), 6=804(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-455/84, 3-4=-650/94, 4-5=-703/77, 2-9=-446/90, 5-6=-705/31 BOT CHORD 7-9=-58/632 WEBS 4-7=-3/393, 3-9=-470/0, 5-7=0/451 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 15-4-4, Exterior(2E) 15-4-4 to 18-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Refer to girder(s) for truss to truss connections. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T03 Truss Type Piggyback Base Qty 2 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097754 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:27 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ZwbKQQAUs2LgbJGWpbhqEwzIGk6-ViKYHTBr6DEHBKZgbARN64av0qgPX_L2gJ9hN8zH8O6 Scale = 1:79.4 1 2 3 4 5 6 7 8 910 18 17 16 15 14 13 12 11 19 20 21 22 23 24 25 3x6 5x8 5x8 3x6 12x18 MT18HS 3x8 MT18HS 3x4 3x6 3x6 3x8 3x4 3x6 12x18 MT18HS3x6 8-3-88-3-8 16-4-88-1-0 21-6-85-2-0 29-7-88-1-0 37-11-08-3-8 -1-0-0 1-0-0 8-3-8 8-3-8 16-4-8 8-1-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 38-11-0 1-0-0 1-1-012-0-01-1-012-0-08.00 12 Plate Offsets (X,Y)-- [3:0-1-12,0-1-8], [5:0-5-12,0-2-0], [6:0-5-12,0-2-0], [8:0-1-12,0-1-8], [11:Edge,0-10-2], [12:0-2-4,0-1-8], [17:0-2-4,0-1-8], [18:Edge,0-10-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.90 0.83 0.48 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.35 0.07 (loc) 15-17 15-17 11 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 184 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 3-17,8-12,2-17,9-12: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-10-15 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-15, 5-14, 8-14 REACTIONS. (size)18=0-3-8, 11=0-3-8 Max Horz 18=230(LC 9) Max Grav 18=1747(LC 17), 11=1745(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2271/0, 3-5=-1750/69, 5-6=-1356/96, 6-8=-1747/69, 8-9=-2268/0, 2-18=-1620/36, 9-11=-1618/36 BOT CHORD 17-18=-206/603, 15-17=-15/1927, 14-15=0/1411, 12-14=0/1796, 11-12=-84/437 WEBS 3-17=0/300, 3-15=-660/149, 5-15=-16/660, 6-14=0/632, 8-14=-659/149, 8-12=0/300, 2-17=0/1408, 9-12=0/1404 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 35-11-0, Exterior(2E) 35-11-0 to 38-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 2 = 4%, joint 9 = 4% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T03A Truss Type Piggyback Base Qty 4 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097755 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:29 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-R5RIi8D6eqU?Qej3jbTrBVfGleM6?qfL7deoS0zH8O4 Scale = 1:86.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 27 26 25 24 23 22 21 20 19 18 17 16 15 28 29 30 31 32 3x6 5x8 5x10 MT18HS 3x6 3x4 3x4 4x6 6x8 3x4 3x4 3x6 5x6 4x8 6x10 3x4 3x4 3x4 3x4 3x6 3x8 3x4 3x6 4x6 12x18 MT18HS 1-3-0 1-3-0 2-3-8 1-0-8 5-11-13 3-8-5 9-8-3 3-8-5 13-4-8 3-8-5 16-4-8 3-0-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 -1-0-0 1-0-0 1-3-0 1-3-0 2-3-8 1-0-8 5-11-13 3-8-5 9-8-3 3-8-5 13-4-8 3-8-5 16-4-8 3-0-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 38-11-0 1-0-0 1-1-012-0-01-1-00-8-012-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [3:0-3-0,0-2-4], [6:0-1-12,0-1-8], [7:0-1-12,0-1-8], [9:0-5-8,0-1-12], [10:0-6-0,0-1-8], [11:0-1-12,0-1-8], [15:Edge,0-10-2], [16:0-2-4,0-1-8], [19:0-2-12,0-1-8], [21:0-2-12,0-2-12], [24:0-6-12,0-3-12], [25:Edge,0-2-8], [26:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.89 0.81 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.34 0.14 (loc) 16-18 16-18 15 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 211 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 4-25,8-20: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 9-21,9-19,9-18,10-18,11-18,2-27,13-15: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-10-4 max.): 9-10. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. Except: 1 Row at midpt 8-21 WEBS 1 Row at midpt 9-19, 9-18, 11-18 REACTIONS. (size)27=0-3-8, 15=0-3-8 Max Horz 27=-230(LC 8) Max Grav 27=1712(LC 17), 15=1734(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1332/0, 3-4=-2898/53, 4-6=-2467/9, 6-7=-2219/28, 7-8=-1944/54, 8-9=-1928/129, 9-10=-1342/96, 10-11=-1730/68, 11-13=-2249/0, 2-27=-1639/2, 13-15=-1606/37 BOT CHORD 26-27=-195/278, 4-24=-57/256, 23-24=-140/2652, 22-23=-35/2161, 21-22=0/1922, 18-19=0/1373, 16-18=0/1780, 15-16=-83/439 WEBS 3-26=-1784/58, 24-26=-99/1457, 3-24=-65/1769, 4-23=-522/112, 6-22=-357/82, 7-22=-12/409, 7-21=-538/100, 19-21=0/1314, 9-21=-133/1082, 10-18=0/603, 11-18=-657/149, 11-16=0/299, 2-26=0/1137, 13-16=0/1386 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-2-4, Interior(1) 2-2-4 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 35-11-0, Exterior(2E) 35-11-0 to 38-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 13 = 4% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T03B Truss Type PIGGYBACK BASE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097756 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:30 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-vH?hvUEkP8cs2oIFHJ?4kiCY?2j?kFRUMHOL_TzH8O3 Scale = 1:80.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 29 28 27 26 25 24 23 22 21 20 19 18 17 30 31 32 33 34 35 36 37 3x6 6x8 5x8 3x6 3x6 3x4 3x4 4x6 3x4 3x4 3x8 3x4 3x4 3x4 6x8 8x8 4x6 6x10 4x6 4x10 3x4 3x4 3x8 3x6 3x6 4x6 4x6 5-7-35-7-3 12-4-06-8-13 16-4-84-0-8 18-6-102-2-2 21-6-82-11-14 22-7-81-1-0 26-4-123-9-4 32-8-36-3-7 37-11-05-2-13 -0-11-0 0-11-0 4-3-0 4-3-0 8-3-8 4-0-8 12-4-0 4-0-8 16-4-8 4-0-8 18-6-10 2-2-2 21-6-8 2-11-14 22-7-8 1-1-0 26-4-12 3-9-4 30-2-0 3-9-4 33-11-4 3-9-4 37-11-0 3-11-12 38-10-0 0-11-0 1-1-012-0-01-1-03-0-012-0-08.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-1-8], [4:0-1-12,0-1-8], [6:0-1-12,0-1-8], [7:0-6-4,0-2-4], [9:0-5-12,0-2-0], [10:0-2-12,0-2-0], [13:0-1-12,0-1-8], [14:0-2-0,0-1-8], [19:0-4-4,0-1-8], [21:0-7-8,0-4-8], [23:0-2-0,Edge], [25:0-1-12,0-1-12], [29:0-2-12,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.41 0.71 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.40 0.33 (loc) 20 20 17 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 232 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-25: 2x4 SPF No.2, 2-29,15-17: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-11 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-10 max.): 7-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 23-24. 1 Row at midpt 8-23 WEBS 1 Row at midpt 6-25, 7-25, 9-23, 10-22, 11-19, 3-29, 14-17 REACTIONS. (size)29=0-3-8, 17=0-3-8 Max Horz 29=-230(LC 8) Max Grav 29=1728(LC 17), 17=1715(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-357/69, 3-4=-2154/40, 4-6=-1916/45, 6-7=-1640/87, 7-8=-1763/43, 8-9=-1772/42, 9-10=-2097/43, 10-11=-2393/0, 11-13=-1940/41, 13-14=-2119/38, 14-15=-341/63, 2-29=-359/73, 15-17=-348/67 BOT CHORD 27-29=-61/1844, 26-27=-7/1802, 25-26=0/1634, 22-23=0/1798, 21-22=0/1963, 10-21=0/1122, 18-19=0/1685, 17-18=0/1657 WEBS 4-26=-311/109, 6-26=-22/502, 6-25=-650/123, 7-25=-1340/0, 23-25=0/2432, 7-23=0/2071, 9-22=-57/998, 10-22=-1057/46, 19-21=0/2051, 11-21=-7/692, 11-19=-1000/0, 13-19=-273/103, 3-29=-1971/0, 14-17=-1950/0 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 35-10-0, Exterior(2E) 35-10-0 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T03C Truss Type PIGGYBACK BASE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097757 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:32 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-rg7RKAF_wlsZH6SeOk1Yp7HuVrOTC9wnpbtS3LzH8O1 Scale = 1:80.0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 29 28 27 26 25 24 23 22 21 20 19 18 17 30 31 32 33 34 35 36 37 3x6 6x8 5x8 3x6 3x6 3x4 3x4 4x6 3x4 3x4 3x8 3x4 3x4 3x4 6x8 8x8 4x6 6x10 4x6 4x10 3x4 3x4 3x8 3x6 3x6 4x6 4x6 5-7-35-7-3 12-4-06-8-13 16-4-84-0-8 18-6-102-2-2 21-6-82-11-14 22-7-81-1-0 26-4-123-9-4 32-8-36-3-7 37-11-05-2-13 -0-11-0 0-11-0 4-3-0 4-3-0 8-3-8 4-0-8 12-4-0 4-0-8 16-4-8 4-0-8 18-6-10 2-2-2 21-6-8 2-11-14 22-7-8 1-1-0 26-4-12 3-9-4 30-2-0 3-9-4 33-11-4 3-9-4 37-11-0 3-11-12 38-10-0 0-11-0 1-1-012-0-01-1-03-0-012-0-08.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-1-8], [4:0-1-12,0-1-8], [6:0-1-12,0-1-8], [7:0-6-4,0-2-4], [9:0-5-12,0-2-0], [10:0-2-12,0-2-0], [13:0-1-12,0-1-8], [14:0-2-0,0-1-8], [19:0-4-4,0-1-8], [21:0-7-8,0-4-8], [23:0-2-0,Edge], [25:0-1-12,0-1-12], [29:0-2-12,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.41 0.71 0.85 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.22 -0.40 0.33 (loc) 20 20 17 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 232 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-25: 2x4 SPF No.2, 2-29,15-17: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-7-11 oc purlins, except end verticals, and 2-0-0 oc purlins (4-3-10 max.): 7-9. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 23-24. 1 Row at midpt 8-23 WEBS 1 Row at midpt 6-25, 7-25, 9-23, 10-22, 11-19, 3-29, 14-17 REACTIONS. (size)29=0-3-8, 17=0-3-8 Max Horz 29=-230(LC 8) Max Grav 29=1728(LC 17), 17=1715(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-357/69, 3-4=-2154/40, 4-6=-1916/45, 6-7=-1640/87, 7-8=-1763/43, 8-9=-1772/42, 9-10=-2097/43, 10-11=-2393/0, 11-13=-1940/41, 13-14=-2119/38, 14-15=-341/63, 2-29=-359/73, 15-17=-348/67 BOT CHORD 27-29=-61/1844, 26-27=-7/1802, 25-26=0/1634, 22-23=0/1798, 21-22=0/1963, 10-21=0/1122, 18-19=0/1685, 17-18=0/1657 WEBS 4-26=-311/109, 6-26=-22/502, 6-25=-650/123, 7-25=-1340/0, 23-25=0/2432, 7-23=0/2071, 9-22=-57/998, 10-22=-1057/46, 19-21=0/2051, 11-21=-7/692, 11-19=-1000/0, 13-19=-273/103, 3-29=-1971/0, 14-17=-1950/0 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 35-10-0, Exterior(2E) 35-10-0 to 38-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T04 Truss Type Piggyback Base Qty 17 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097758 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:34 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ZwbKQQAUs2LgbJGWpbhqEwzIGk6-o2FBlsHESM6HWPb1W830uYN5Lf36g7M4HvMZ7EzH8O? Scale = 1:78.5 1 2 3 4 5 6 7 8 9 17 16 15 14 13 12 11 10 18 19 20 21 22 23 24 3x6 5x8 5x8 3x8 12x18 MT18HS 3x8 MT18HS 3x4 3x6 3x6 3x8 3x4 3x8 3x8 MT18HS 6x6 3x6 8-3-88-3-8 16-4-88-1-0 21-6-85-2-0 29-5-127-11-4 37-7-88-1-12 -1-0-0 1-0-0 8-3-8 8-3-8 16-4-8 8-1-0 21-6-8 5-2-0 29-5-12 7-11-4 37-7-8 8-1-12 1-1-012-0-01-3-512-0-08.00 12 Plate Offsets (X,Y)-- [4:0-1-12,0-1-8], [5:0-5-12,0-2-0], [6:0-5-12,0-2-0], [7:0-1-12,0-1-8], [9:0-3-4,Edge], [11:0-2-8,0-1-8], [16:0-2-4,0-1-8], [17:Edge,0-10-2] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.96 0.82 0.59 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.19 -0.35 0.07 (loc) 14-16 14-16 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 179 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 4-16,7-13,7-11,9-11,2-16: 2x3 SPF No.2, 9-10: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-11-9 max.): 5-6. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-14, 5-13, 7-13 REACTIONS. (size)17=0-3-8, 10=Mechanical Max Horz 17=227(LC 7) Max Grav 17=1736(LC 17), 10=1668(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-2253/0, 4-5=-1731/71, 5-6=-1334/99, 6-7=-1721/73, 7-9=-2186/0, 9-10=-1544/20, 2-17=-1609/37 BOT CHORD 16-17=-213/597, 14-16=-25/1905, 13-14=0/1388, 11-13=0/1738 WEBS 4-16=0/301, 4-14=-661/149, 5-14=-15/662, 6-13=-2/626, 7-13=-620/149, 7-11=-5/260, 9-11=0/1522, 2-16=0/1392 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 34-5-12, Exterior(2E) 34-5-12 to 37-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) The Fabrication Tolerance at joint 2 = 4% 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T05 Truss Type COMMON Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097759 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:34 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-o2FBlsHESM6HWPb1W830uYNAufChgFT4HvMZ7EzH8O? Scale = 1:35.0 1 2 3 4 5 8 7 6 9 10 4x6 3x4 3x4 2x4 4x8 4x8 5-11-85-11-8 11-11-05-11-8 -0-11-0 0-11-0 5-11-8 5-11-8 11-11-0 5-11-8 12-10-0 0-11-0 1-2-05-7-101-2-09.00 12 Plate Offsets (X,Y)-- [2:0-4-6,Edge], [4:0-4-6,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.67 0.21 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.03 -0.06 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-7: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=117(LC 9) Max Uplift 8=-5(LC 10), 6=-5(LC 11) Max Grav 8=529(LC 1), 6=529(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-455/82, 3-4=-455/82, 2-8=-464/117, 4-6=-464/117 BOT CHORD 7-8=0/279, 6-7=0/279 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 2-11-8, Exterior(2R) 2-11-8 to 8-11-8, Interior(1) 8-11-8 to 9-10-0, Exterior(2E) 9-10-0 to 12-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T06 Truss Type Common Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097760 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:35 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-GFpayCHsDgE88ZAD3saFRmvMN3MUPWMDVZ56ggzH8O_ Scale = 1:59.9 1 2 3 4 5 6 10 9 8 7 11 12 13 14 15 16 4x6 3x6 3x16 MT18HS 3x8 3x4 3x4 3x6 5x6 5x6 10-5-810-5-8 20-11-010-5-8 -1-0-0 1-0-0 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 20-11-0 5-4-0 1-3-09-11-91-3-010.00 12 Plate Offsets (X,Y)-- [7:Edge,0-2-4], [10:Edge,0-2-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.62 1.00 0.87 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.33 -0.55 0.02 (loc) 7-8 8-10 7 l/defl >761 >448 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 89 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-10,6-7: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied. REACTIONS. (size)10=0-3-8, 7=0-3-8 Max Horz 10=192(LC 7) Max Grav 10=995(LC 17), 7=929(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-429/87, 3-4=-822/90, 4-5=-823/91, 5-6=-398/56, 2-10=-428/92, 6-7=-338/55 BOT CHORD 8-10=-48/754, 7-8=0/677 WEBS 4-8=-27/675, 3-10=-643/3, 5-7=-661/21 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 7-5-8, Exterior(2R) 7-5-8 to 13-5-8, Interior(1) 13-5-8 to 17-9-4, Exterior(2E) 17-9-4 to 20-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T07 Truss Type Common Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097761 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:36 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-kRNyAYIV__M?mjlPdZ5U_zSZ4Sub891NkDrgB6zH8Nz Scale = 1:38.6 1 2 3 4 7 6 5 8 9 5x6 4x6 3x4 3x4 3x8 5x6 5-11-85-11-8 11-11-05-11-8 5-11-8 5-11-8 11-11-0 5-11-8 12-11-0 1-0-0 1-3-06-2-91-3-010.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-4], [3:0-3-8,0-1-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.50 0.24 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.05 0.00 (loc) 6-7 6-7 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 49 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-7,3-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-8, 5=0-3-8 Max Horz 7=-125(LC 6) Max Uplift 5=-2(LC 11) Max Grav 7=462(LC 1), 5=537(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-444/80, 2-3=-451/84, 1-7=-410/72, 3-5=-485/107 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 8-11-8, Interior(1) 8-11-8 to 9-11-0, Exterior(2E) 9-11-0 to 12-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T08 Truss Type Common Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097762 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:37 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-CdwKNtJ7lHUsNtKbBHdjWB_masFwtdTWzsaDjZzH8Ny Scale = 1:34.4 1 2 3 4 5 8 7 6 9 10 4x6 3x4 3x4 3x8 5x6 5x6 5-1-05-1-0 10-2-05-1-0 -1-0-0 1-0-0 5-1-0 5-1-0 10-2-0 5-1-0 11-2-0 1-0-0 1-3-05-5-131-3-010.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [4:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.32 0.17 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.00 (loc) 6-7 6-7 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 43 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-8,4-6: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)8=0-3-8, 6=0-3-8 Max Horz 8=118(LC 9) Max Uplift 8=-4(LC 10), 6=-4(LC 11) Max Grav 8=464(LC 1), 6=464(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-367/89, 3-4=-367/89, 2-8=-419/118, 4-6=-419/118 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 8-2-0, Exterior(2E) 8-2-0 to 11-2-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T09 Truss Type Common Qty 2 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097763 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:38 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-gqUibDKlWbcj?1vol_8y3OXyNGa9c4kfCWKmF?zH8Nx Scale = 1:34.4 1 2 3 4 7 6 5 8 9 4x6 5x6 3x4 3x4 3x8 5x6 5-1-05-1-0 10-2-05-1-0 -1-0-0 1-0-0 5-1-0 5-1-0 10-2-0 5-1-0 1-3-05-5-131-3-010.00 12 Plate Offsets (X,Y)-- [2:0-2-12,0-1-8], [4:0-2-12,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.32 0.17 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.01 -0.03 0.00 (loc) 5-6 5-6 5 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-7,4-5: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)7=0-3-8, 5=Mechanical Max Horz 7=112(LC 7) Max Uplift 7=-4(LC 10) Max Grav 7=468(LC 1), 5=391(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-373/86, 3-4=-366/83, 2-7=-423/115, 4-5=-347/76 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-0-0, Exterior(2R) 2-0-0 to 7-0-4, Exterior(2E) 7-0-4 to 10-0-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T10 Truss Type Common Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097764 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:39 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-8024oZKNHvladAU_IifBbc45QgwcLWzpQA3KoRzH8Nw Scale = 1:35.7 1 2 3 6 5 4 7 8 3x4 4x6 3x4 3x4 3x4 3x8 5-1-05-1-0 8-8-03-7-0 5-1-0 5-1-0 8-8-0 3-7-0 1-3-05-5-132-6-010.00 12 Plate Offsets (X,Y)-- [1:0-1-8,0-1-8], [3:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.43 0.16 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6,3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 4=Mechanical Max Horz 6=113(LC 7) Max Uplift 4=-1(LC 10) Max Grav 6=335(LC 1), 4=335(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-259/54, 1-6=-295/72, 3-4=-314/69 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 5-6-4, Exterior(2E) 5-6-4 to 8-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T11 Truss Type Common Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097765 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:39 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-8024oZKNHvladAU_IifBbc45QgwcLWzpQA3KoRzH8Nw Scale = 1:35.7 1 2 3 6 5 4 7 8 3x4 4x6 3x4 3x4 3x4 3x8 5-1-05-1-0 8-8-03-7-0 5-1-0 5-1-0 8-8-0 3-7-0 1-3-05-5-132-6-010.00 12 Plate Offsets (X,Y)-- [1:0-1-8,0-1-8], [3:0-1-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.43 0.16 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.02 -0.04 -0.00 (loc) 5-6 5-6 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 1-6,3-4: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=Mechanical, 4=Mechanical Max Horz 6=113(LC 7) Max Uplift 4=-1(LC 10) Max Grav 6=335(LC 1), 4=335(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-259/54, 1-6=-295/72, 3-4=-314/69 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Exterior(2R) 3-1-12 to 5-6-4, Exterior(2E) 5-6-4 to 8-6-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss T12 Truss Type Piggyback Base Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097766 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:41 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-5PArDFMdpW?IsUeNQ6hfh19IWTSupFe6uUYRsKzH8Nu Scale = 1:84.1 1 2 3 4 5 6 7 8 9 10 11 12 13 26 25 24 23 22 21 20 19 18 17 16 15 14 27 28 29 30 31 3x6 5x8 5x8 3x8 3x4 3x4 4x6 6x8 3x4 3x4 3x6 5x6 4x8 6x10 3x4 3x4 3x4 3x4 3x6 3x8 3x4 3x6 5x6 12x18 MT18HS 1-3-0 1-3-0 2-3-8 1-0-8 5-11-13 3-8-5 9-8-3 3-8-5 13-4-8 3-8-5 16-4-8 3-0-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 -1-0-0 1-0-0 1-3-0 1-3-0 2-3-8 1-0-8 5-11-13 3-8-5 9-8-3 3-8-5 13-4-8 3-8-5 16-4-8 3-0-0 21-6-8 5-2-0 29-7-8 8-1-0 37-11-0 8-3-8 1-1-012-0-01-1-00-8-012-0-08.00 12 Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [3:0-3-0,0-2-4], [6:0-1-12,0-1-8], [7:0-1-12,0-1-8], [9:0-5-8,0-1-12], [10:0-5-12,0-2-0], [11:0-1-12,0-1-8], [14:Edge,0-10-2], [15:0-2-0,0-1-8] , [18:0-2-12,0-1-8], [20:0-2-12,0-2-12], [23:0-6-12,0-3-12], [24:Edge,0-2-8], [25:0-2-8,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.90 0.81 0.75 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.18 -0.34 0.14 (loc) 15-17 15-17 14 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 209 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 12-13: 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 *Except* 4-24,8-19: 2x3 SPF No.2 WEBS 2x3 SPF No.2 *Except* 9-20,9-18,9-17,10-17,11-17: 2x4 SPF No.2 2-26,13-14: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals, and 2-0-0 oc purlins (4-10-3 max.): 9-10. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. Except: 1 Row at midpt 8-20 WEBS 1 Row at midpt 9-18, 9-17, 11-17 REACTIONS. (size)26=0-3-8, 14=0-3-8 Max Horz 26=226(LC 7) Max Grav 26=1712(LC 17), 14=1669(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1325/0, 3-4=-2893/60, 4-6=-2465/11, 6-7=-2219/29, 7-8=-1944/54, 8-9=-1927/130, 9-10=-1341/97, 10-11=-1731/70, 11-13=-2247/0, 2-26=-1635/2, 13-14=-1541/22 BOT CHORD 25-26=-203/261, 4-23=-59/254, 22-23=-155/2640, 21-22=-45/2153, 20-21=0/1914, 17-18=0/1366, 15-17=0/1786, 14-15=-43/331 WEBS 3-25=-1791/65, 23-25=-110/1445, 3-23=-72/1765, 4-22=-519/116, 6-21=-356/82, 7-21=-12/409, 7-20=-538/101, 18-20=0/1308, 9-20=-135/1080, 10-17=0/606, 11-17=-665/151, 11-15=0/294, 2-25=0/1149, 13-15=0/1484 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -1-0-0 to 2-2-4, Interior(1) 2-2-4 to 12-1-9, Exterior(2R) 12-1-9 to 25-9-7, Interior(1) 25-9-7 to 34-9-4, Exterior(2E) 34-9-4 to 37-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss TG02 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097767 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:44 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-V_rzrHOW6RNsjyMy5FFMIfnsWha60eqYaSn5TfzH8Nr Scale = 1:82.3 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 17 18 21 23 22484950 3x6 7x16 MT18HS 5x10 MT18HS 3x6 4x6 4x6 3x6 3x4 4x6 3x4 3x6 4x6 5x6 4x6 5x6 4x6 2x4 2x4 3x8 2x4 2x4 3x8 3x8 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6-6-106-6-10 12-10-136-4-2 21-6-38-7-6 27-10-66-4-2 34-5-06-6-10 6-6-10 6-6-10 12-10-13 6-4-2 21-6-3 8-7-6 27-10-6 6-4-2 34-5-0 6-6-10 1-3-012-0-01-3-012-0-010.00 12 Plate Offsets (X,Y)-- [1:Edge,0-1-8], [3:0-0-12,0-1-8], [4:1-0-12,0-1-12], [5:0-6-12,0-1-12], [8:Edge,0-1-8], [9:Edge,0-3-8], [10:0-3-0,0-1-12], [15:0-3-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.73 0.40 0.59 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.14 0.03 (loc) 11-14 11-14 9 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 271 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 4-5: 2x4 SP 2400F 2.0E BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 3-14,4-14,4-11,5-11,6-11: 2x4 SPF No.2, 3-17,19-20: 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 4-5. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 3-14, 4-11, 6-11 REACTIONS. (size)16=0-5-8, 9=0-3-8 Max Horz 16=216(LC 33) Max Grav 16=1480(LC 26), 9=1459(LC 26) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-1750/13, 3-4=-1458/90, 4-5=-1038/118, 5-6=-1450/94, 6-8=-1720/17, 1-16=-1366/18, 8-9=-1343/21 BOT CHORD 15-16=-208/365, 14-15=-50/1373, 11-14=-23/1074, 10-11=0/1243 WEBS 3-14=-422/161, 14-17=-33/577, 4-17=-33/577, 11-21=-12/534, 5-21=-12/534, 1-15=0/1085, 8-10=0/1060, 11-22=-387/157, 6-22=-400/162 NOTES-(13-14) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) Vertical gable studs spaced at 2-0-0 oc and horizontal gable studs spaced at 0-1-4 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 9 lb down and 11 lb up at 15-5-4, 9 lb down and 11 lb up at 17-5-4, and 9 lb down and 11 lb up at 19-5-4, and 9 lb down and 11 lb up at 21-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 13) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 14) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.).Continued on page 2 May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss TG02 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097767 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:44 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-V_rzrHOW6RNsjyMy5FFMIfnsWha60eqYaSn5TfzH8Nr LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-5=-60, 5-8=-60, 9-16=-20 Concentrated Loads (lb) Vert: 13=2(F) 11=2(F) 49=2(F) 50=2(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss TG03 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097768 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:46 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-RMzkGyQmd2dazFWKDgHqO4sA1UFBUfcr1mGBXXzH8Np Scale = 1:59.9 1 2 3 4 5 6 7 8 9 13 12 11 10 15 1614 31 32 33 34 35 36 37 38 39 40 4x6 5x12 4x6 3x8 2x4 2x4 5x12 2x4 3x8 3x8 3x8 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 10-5-810-5-8 20-11-010-5-8 -1-0-0 1-0-0 5-4-0 5-4-0 10-5-8 5-1-8 15-7-0 5-1-8 20-11-0 5-4-0 21-11-0 1-0-0 1-3-09-11-91-3-010.00 12 Plate Offsets (X,Y)-- [10:Edge,0-3-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.85 0.42 0.19 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.07 -0.14 0.01 (loc) 11-13 11-13 10 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 139 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 5-11,3-14,7-16: 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-9-4 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 14, 16 REACTIONS. (size)13=0-3-8, 10=0-3-8 Max Horz 13=-196(LC 6) Max Uplift 13=-77(LC 8), 10=-77(LC 9) Max Grav 13=858(LC 1), 10=858(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-712/90, 3-4=-964/91, 4-5=-782/124, 5-6=-782/125, 6-7=-964/92, 7-8=-712/89, 2-13=-764/99, 8-10=-764/99 BOT CHORD 11-13=-106/448, 10-11=-25/354 WEBS 11-15=-72/587, 5-15=-72/587, 11-16=-272/155, 6-16=-278/156, 4-14=-278/156, 11-14=-272/156, 3-14=0/367, 14-15=0/351, 15-16=0/351, 7-16=0/367 NOTES-(12-13) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) The Fabrication Tolerance at joint 2 = 12%, joint 8 = 12% 5) Vertical gable studs spaced at 2-0-0 oc and horizontal gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 10. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 29 lb down and 72 lb up at 0-10-1, and 29 lb down and 72 lb up at 20-0-15 on top chord, and 9 lb down and 11 lb up at 0-10-1, 9 lb down and 11 lb up at 2-5-8, 9 lb down and 11 lb up at 4-5-8, 9 lb down and 11 lb up at 6-5-8, 9 lb down and 11 lb up at 8-5-8, 9 lb down and 11 lb up at 10-5-8, 9 lb down and 11 lb up at 12-5-8, 9 lb down and 11 lb up at 14-5-8, 9 lb down and 11 lb up at 16-5-8, and 9 lb down and 11 lb up at 18-5-8, and 9 lb down and 11 lb up at 20-0-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Continued on page 2 May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss TG03 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097768 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:46 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-RMzkGyQmd2dazFWKDgHqO4sA1UFBUfcr1mGBXXzH8Np 12) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 13) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-5=-60, 5-8=-60, 8-9=-60, 10-13=-20 Concentrated Loads (lb) Vert: 11=2(B) 3=23(B) 7=23(B) 31=2(B) 32=2(B) 33=2(B) 34=2(B) 35=2(B) 36=2(B) 37=2(B) 38=2(B) 39=2(B) 40=2(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss TG04 Truss Type PIGGYBACK BASE GIRDE Qty 1 Ply 3 33 Estates at Towne Meadow Job Reference (optional) I46097769 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:50 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ZwbKQQAUs2LgbJGWpbhqEwzIGk6-K7DE6KTHhH70Rtq5SVLmYw1s86Z4QG6QyOEPgJzH8Nl Scale = 1:74.4 1 2 3 4 5 6 7 8 9 10 11 22 21 20 19 18 17 16 15 14 13 1223242526272829303132333435363738 3x6 5x8 5x8 3x6 12x18 MT18HS 4x8 3x6 8x8 8x8 4x6 8x8 8x8 4x6 8x8 3x6 8x8 12x18 MT18HS4x8 2x4 8x16 4-5-154-5-15 8-8-64-2-7 12-10-134-2-7 17-1-44-2-7 21-6-34-4-15 25-8-104-2-7 29-11-14-2-7 34-5-04-5-15 4-5-15 4-5-15 8-8-6 4-2-7 12-10-13 4-2-7 17-1-4 4-2-7 17-2-8 0-1-4 21-6-3 4-3-11 25-8-10 4-2-7 29-11-1 4-2-7 34-5-0 4-5-15 1-3-012-0-01-3-012-0-010.00 12 Plate Offsets (X,Y)-- [3:0-2-0,0-1-8], [4:0-1-4,0-1-12], [5:0-6-4,0-2-0], [7:0-6-4,0-2-0], [8:0-1-8,0-1-12], [9:0-2-0,0-1-8], [12:Edge,0-10-6], [13:0-3-8,0-4-12], [14:0-3-8,0-4-8], [15:0-3-8,0-4-12], [19:0-3-8,0-4-12], [20:0-4-0,0-4-12], [21:0-3-8,0-4-8], [22:Edge,0-10-6] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.84 0.68 0.99 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.08 -0.14 0.02 (loc) 19-20 19-20 12 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 721 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 4-19,5-19,7-15,8-15,6-17: 2x4 SPF No.2 5-17,7-17: 2x4 SPF 2100F 1.8E BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 5-7. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)22=0-5-8, 12=0-3-8, 17=0-3-8 Max Horz 22=216(LC 5) Max Grav 22=5772(LC 23), 12=6442(LC 24), 17=18407(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-5602/0, 3-4=-3382/0, 4-5=-669/0, 5-6=0/2125, 6-7=0/2125, 7-8=-802/0, 8-9=-3485/0, 9-11=-5739/0, 1-22=-4452/0, 11-12=-4558/0 BOT CHORD 21-22=-55/730, 20-21=0/4239, 19-20=0/2563, 17-19=0/566, 15-17=0/655, 14-15=0/2643, 13-14=0/4344, 12-13=0/665 WEBS 3-21=0/3079, 3-20=-2481/0, 4-20=0/5438, 4-19=-4445/0, 5-19=0/7507, 5-17=-7769/0, 7-15=0/7512, 8-15=-4396/0, 8-14=0/5376, 9-14=-2520/0, 9-13=0/3130, 1-21=0/3682, 11-13=0/3766, 7-17=-7736/0, 6-17=-355/64 NOTES-(14-15) 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 3 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, Except member 9-13 2x4 - 1 row at 0-5-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Bearing at joint(s) 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide metal plate or equivalent at bearing(s) 17 to support reaction shown. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.Continued on page 2 May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss TG04 Truss Type PIGGYBACK BASE GIRDE Qty 1 Ply 3 33 Estates at Towne Meadow Job Reference (optional) I46097769 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:50 2021 Page 2 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:ZwbKQQAUs2LgbJGWpbhqEwzIGk6-K7DE6KTHhH70Rtq5SVLmYw1s86Z4QG6QyOEPgJzH8Nl NOTES-(14-15) 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1623 lb down at 1-6-12, 1623 lb down at 3-6-12, 1623 lb down at 5-6-12, 1623 lb down at 7-6-12, 1610 lb down at 9-6-12, 1620 lb down at 11-6-12, 1613 lb down at 13-6-12, 1615 lb down at 15-6-12, 1623 lb down at 17-6-12, 1609 lb down at 19-6-12, 1618 lb down at 21-6-12, 1615 lb down at 23-6-12, 1615 lb down at 25-6-12, 1623 lb down at 27-6-12, 1623 lb down at 29-6-12, and 1623 lb down at 31-6-12, and 1626 lb down at 33-6-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 14) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 15) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-60, 5-7=-60, 7-11=-60, 12-22=-20 Concentrated Loads (lb) Vert: 18=-1472(B) 15=-1472(B) 14=-1472(B) 23=-1472(B) 24=-1472(B) 25=-1472(B) 26=-1472(B) 27=-1472(B) 29=-1472(B) 30=-1472(B) 31=-1472(B) 33=-1472(B) 34=-1472(B) 35=-1472(B) 36=-1472(B) 37=-1472(B) 38=-1475(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V01 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097770 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:51 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-oKndJgUvSbFt30PI?Dt?58a9pV0s9vWaB2zyDlzH8Nk Scale = 1:81.9 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 22 23 3x6 4x6 3x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 31-0-931-0-9 15-6-4 15-6-4 31-0-9 15-6-4 0-0-412-11-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.34 0.13 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 119 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud *Except* 1-4,8-11: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 6-15: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15, 5-17, 7-14 REACTIONS.All bearings 31-0-9. (lb) - Max Horz 1=-226(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 18, 19, 13, 12, 11 except 17=-103(LC 10), 14=-102(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 15=408(LC 20), 17=467(LC 17), 18=451(LC 17), 19=400(LC 17), 14=467(LC 18), 13=451(LC 18), 12=400(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-265/183 WEBS 5-17=-267/150, 3-18=-251/143, 7-14=-267/150, 9-13=-251/143 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-6-4, Interior(1) 3-6-4 to 12-6-4, Exterior(2R) 12-6-4 to 18-6-4, Interior(1) 18-6-4 to 27-6-4, Exterior(2E) 27-6-4 to 30-7-11 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 18, 19, 13, 12, 11 except (jt=lb) 17=103, 14=102. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V02 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097771 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:52 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-GWK?X0VXDuNkhA_UZwOEdL6MqvM3uJjjQijWlBzH8Nj Scale = 1:70.8 1 2 3 4 5 6 7 8 9 10 11 19 18 17 16 15 14 13 12 20 21 3x6 4x6 3x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x4 27-10-227-10-2 13-11-1 13-11-1 27-10-2 13-11-1 0-0-411-7-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.19 0.13 0.41 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 105 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 1-3,9-11: 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 *Except* 6-15: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-15 REACTIONS.All bearings 27-10-2. (lb) - Max Horz 1=202(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 1, 18, 19, 13, 12, 11 except 17=-102(LC 10), 14=-102(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 11 except 15=401(LC 20), 17=469(LC 17), 18=433(LC 17), 19=314(LC 17), 14=469(LC 18), 13=433(LC 18), 12=314(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 5-17=-266/150, 4-18=-258/146, 7-14=-266/149, 8-13=-258/146 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Interior(1) 3-4-13 to 10-11-1, Exterior(2R) 10-11-1 to 16-11-1, Interior(1) 16-11-1 to 24-5-5, Exterior(2E) 24-5-5 to 27-5-5 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 18, 19, 13, 12, 11 except (jt=lb) 17=102, 14=102. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V03 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097772 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:53 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-kiuNkMV9_CVbIKYg7evTAZfY8JiKdo?teMS3HdzH8Ni Scale = 1:65.3 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 16 173x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-7-1224-7-12 12-3-14 12-3-14 24-7-12 12-3-14 0-0-410-3-40-0-410.00 12 Plate Offsets (X,Y)-- [11:0-2-9,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.16 0.13 0.28 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 24-7-12. (lb) - Max Horz 1=-178(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1 except 12=-101(LC 10), 13=-103(LC 10), 9=-100(LC 11), 8=-103(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=369(LC 20), 12=461(LC 17), 13=456(LC 17), 9=460(LC 18), 8=456(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-265/151, 2-13=-265/143, 5-9=-264/150, 6-8=-265/143 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Interior(1) 3-4-13 to 9-3-14, Exterior(2R) 9-3-14 to 15-3-14, Interior(1) 15-3-14 to 21-2-14, Exterior(2E) 21-2-14 to 24-2-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 12=101, 13=103, 9=100, 8=103. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V04 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097773 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:54 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-CvSlyhWnlWdSwU7thLQiimCjhj2TMHj0t0Cdq4zH8Nh Scale = 1:57.6 1 2 3 4 5 6 7 13 12 11 10 9 8 14 15 3x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 21-5-521-5-5 10-8-11 10-8-11 21-5-5 10-8-11 0-0-48-11-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.17 0.14 0.18 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 72 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-12: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-10 REACTIONS.All bearings 21-5-5. (lb) - Max Horz 1=-154(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 13, 8 except 11=-106(LC 10), 9=-106(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 10=362(LC 20), 11=451(LC 17), 13=335(LC 17), 9=449(LC 18), 8=336(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-276/156, 5-9=-276/156 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Interior(1) 3-4-13 to 7-8-11, Exterior(2R) 7-8-11 to 13-8-11, Interior(1) 13-8-11 to 18-0-8, Exterior(2E) 18-0-8 to 21-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 13, 8 except (jt=lb) 11=106, 9=106. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V05 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097774 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:55 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-g50791XPWpmIYei3E3xxF_ktV7Ls5k6A6gxAMWzH8Ng Scale = 1:46.9 1 2 3 4 5 9 8 7 6 10 11 3x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 18-2-1518-2-15 9-1-8 9-1-8 18-2-15 9-1-8 0-0-47-7-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.23 0.32 0.17 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 57 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 1-8: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 18-2-15. (lb) - Max Horz 1=130(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 9=-128(LC 10), 6=-128(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=322(LC 20), 9=542(LC 17), 6=543(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-326/172, 4-6=-320/171 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-13 to 3-4-13, Interior(1) 3-4-13 to 6-1-8, Exterior(2R) 6-1-8 to 12-1-8, Interior(1) 12-1-8 to 14-10-2, Exterior(2E) 14-10-2 to 17-10-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 128 lb uplift at joint 9 and 128 lb uplift at joint 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V06 Truss Type GABLE Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097775 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:56 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-8HaWNNY2H7u99oHFomSAoBH1wWk1qBvJKKhjuyzH8Nf Scale = 1:38.9 1 2 3 4 5 8 7 6 9 10 11 123x4 5x6 3x4 2x4 2x4 2x4 2x4 2x4 15-0-915-0-9 7-6-4 7-6-4 15-0-9 7-6-4 0-0-46-3-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.31 0.13 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 15-0-9. (lb) - Max Horz 1=-107(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-106(LC 10), 6=-106(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=341(LC 17), 8=419(LC 17), 6=418(LC 18) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-257/145, 4-6=-257/145 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-6-4, Interior(1) 3-6-4 to 4-6-4, Exterior(2R) 4-6-4 to 10-6-4, Interior(1) 10-6-4 to 11-6-4, Exterior(2E) 11-6-4 to 14-7-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=106, 6=106. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V07 Truss Type Valley Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097776 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:57 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-dU8uajYg2R00nxsRMU_PKPpC2w4XZgUSZ_QHQPzH8Ne Scale = 1:30.7 1 2 3 4 5 8 7 6 9 10 3x4 3x4 3x4 2x4 2x4 2x4 2x4 2x4 11-10-211-10-2 5-11-1 5-11-1 11-10-2 5-11-1 0-0-44-11-40-0-410.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-SH 0.23 0.12 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 11-10-2. (lb) - Max Horz 1=-83(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 7, 6, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 6=317(LC 18), 8=318(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-4-9 to 3-4-9, Exterior(2R) 3-4-9 to 8-5-9, Exterior(2E) 8-5-9 to 11-5-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 6, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V08 Truss Type VALLEY Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097777 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:58 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-5giGn3ZIpk8tP5RewBVetcMGMKKfI6qcoeAqzrzH8Nd Scale = 1:40.2 1 2 3 6 5 4 7 5x10 MT18HS 6x6 4x6 6x6 5x10 MT18HS 2x4 3x6 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 6-1-07-3-106-1-010.00 12 Plate Offsets (X,Y)-- [1:Edge,0-2-0], [3:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.70 0.51 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 MT18HS Weight: 23 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=2-11-0, 4=2-11-0, 5=2-11-0 Max Horz 6=-174(LC 6) Max Uplift 6=-195(LC 8), 4=-195(LC 9) Max Grav 6=224(LC 7), 4=224(LC 6), 5=103(LC 17) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=195, 4=195. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V09 Truss Type Valley Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097778 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:57:59 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-ZsFe?Pawa2Gk0F0qTu0tPqvVfkj?1Y6l1IvOVHzH8Nc Scale = 1:33.3 1 2 3 6 5 4 4x6 3x6 3x4 3x6 4x6 2x4 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 4-9-05-11-104-9-010.00 12 Plate Offsets (X,Y)-- [3:0-3-4,0-0-0], [4:0-2-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.41 0.31 0.11 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=2-11-0, 4=2-11-0, 5=2-11-0 Max Horz 6=-141(LC 6) Max Uplift 6=-130(LC 6), 4=-130(LC 7) Max Grav 6=169(LC 9), 4=169(LC 8), 5=118(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=130, 4=130. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V10 Truss Type Valley Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097779 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:58:00 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-13p0ClbYKMObePb01cX6y1RjV85Nm0PvFyfx1jzH8Nb Scale = 1:26.5 1 2 3 6 5 4 3x4 3x4 3x4 3x4 3x4 2x4 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 3-5-04-7-103-5-010.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.21 0.17 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=2-11-0, 4=2-11-0, 5=2-11-0 Max Horz 6=-106(LC 6) Max Uplift 6=-69(LC 6), 4=-69(LC 7) Max Grav 6=106(LC 9), 4=106(LC 8), 5=117(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V11 Truss Type Valley Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097780 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:58:00 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-13p0ClbYKMObePb01cX6y1Rle86sm0jvFyfx1jzH8Nb Scale = 1:19.6 1 2 3 6 5 4 3x4 3x4 3x4 3x4 3x4 2x4 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 2-1-03-3-102-1-010.00 12 Plate Offsets (X,Y)-- [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.08 0.08 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a -0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=2-11-0, 4=2-11-0, 5=2-11-0 Max Horz 6=-71(LC 6) Max Uplift 6=-25(LC 6), 4=-24(LC 7) Max Grav 6=72(LC 18), 4=72(LC 17), 5=113(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6, 4. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 33_ESTATES_AT_TOWNE_~W Truss V12 Truss Type Valley Qty 1 Ply 1 33 Estates at Towne Meadow Job Reference (optional) I46097781 8.430 s Apr 20 2021 MiTek Industries, Inc. Wed May 12 19:58:01 2021 Page 1 ProBuild (Carter-Lee), Mooresville, IN - 46158, ID:7p1yGKCmG7u_ciwpMABd00zbMnB-VFNPQ5cA5fWSGZADbJ2LUF_xqXSnVTJ2UbOUZAzH8Na Scale = 1:12.7 1 2 3 5 4 3x4 3x4 3x4 3x4 3x4 2-11-02-11-0 1-5-8 1-5-8 2-11-0 1-5-8 0-9-01-11-100-9-010.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge], [4:Edge,0-2-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.05 0.10 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x3 SPF No.2 BOT CHORD 2x3 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-0 oc purlins, except end verticals. BOT CHORD Structural wood sheathing directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=2-11-0, 4=2-11-0 Max Horz 5=-36(LC 6) Max Grav 5=108(LC 1), 4=108(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Ke=0.97; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). May 13,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths