Loading...
HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN  46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design.  Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG140Rev. By Date CommentsDrawn By:DWChecked By: Date:CM 06/07/2021Tribeca 25012 Sheet 1 of 1 Main Floor System Not to Scale Confirm this layout with the builder and designer of record.  Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 19.2" O.C. Spacing 11 7/8" TJI Joists 24" O.C. SpacingFraming Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H1 5 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - 1 Yes Yes H2 1 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - 2 No Yes H3 1 Simpson SUL1.81/11 Designed 16- 10dx1.5 - 6- 10dx1.5 45 (L) - 1 Yes Yes H4 1 Simpson SUR1.81/11 Designed 16- 10dx1.5 - 6- 10dx1.5 45 (R) - 1 Yes Yes H5 1 Simpson SUR410 Designed 14- 16d - 6- 16d 45 (R) - 1 Yes Yes H6 1 Simpson U14 Designed 14- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes Products PlotID Length Product Plies Net Qty FJ201 18' 0" 11 7/8" TJI 110 joist 1 12 FJ203 10' 0" 11 7/8" TJI 110 joist 2 2 FJ202 10' 0" 11 7/8" TJI 110 joist 1 2 FJ205 6' 0" 11 7/8" TJI 110 joist 2 2 FJ204 6' 0" 11 7/8" TJI 110 joist 1 1 FJ206 4' 0" 11 7/8" TJI 110 joist 1 6 FJ207 36' 0" 11 7/8" TJI 360 joist 1 2 FJ208 20' 0" 11 7/8" TJI 360 joist 2 2 FJ209 18' 0" 11 7/8" TJI 360 joist 1 3 FJ210 22' 0" 11 7/8" TJI 560 joist 1 6 FJ211 20' 0" 11 7/8" TJI 560 joist 1 1 FJ212 18' 0" 11 7/8" TJI 560 joist 1 2 BM201 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2 BM202 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 6 BM203 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 11 Blocking PlotID Length Product Plies Net Qty Bk201 2' 0" 11 7/8" TJI 110 joist 1 28  LEVEL NOTES  Current Date:  6/7/2021  File Name:  tg140_25012.jvl  Level Name:  Second Floor System  Building Code - Design Methodology:  IBC 2006  Members with Design Overridden:  TJ-Pro Rating (Weighted Average):  40     Minimum Level TJ - Pro Rating & Joist:  TJ-Pro rating = 32, joist = FJ201(i9219)     Maximum Level TJ - Pro Rating & Joist:  TJ-Pro rating = 65, joist = FJ202(i9306)  FLOOR  Floor Container:  FC1  Use/Occupancy:  ResidentialLivingAreas  Floor Area Loading is:  40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load  Operator Added Additional Loads  Maximum Allowed Deflection:  L/480 Live Load & L/240 Total Load  TJ-Pro Rating Information:      Weighted Average:  40      Directly Applied Ceiling:  Gypsum 1/2"      Decking Attachment:  Glue and Nail      Decking Material:  23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF      Perpendicular Partition:  No      Strapping at max 8' o.c.:  None      Blocking at max 8' o.c.:  No      Poured Flooring:  No A3 A3 A3 A3 H2 H2 H2 B1W E1 B1 E1 BBO21 BM203 BM202BM202BM202BM201 FJ210 FJ210 FJ210 FJ210 FJ210 FJ209 FJ207 FJ212 FJ207 FJ209 FJ209 FJ201 FJ201 FJ201 FJ212 FJ201 FJ201 FJ201 FJ201 FJ201 FJ201 FJ201 FJ201 FJ202 FJ202 Ca201 Ca201 Ca201 Ca201 Ca201 Ca201 Ca201Ca201Ca201Ca201Ca201Bk201 Bk201Bk201FJ206FJ206FJ206FJ206FJ206FJ204FJ205FJ206 FJ203 H2 H1H1H6 H3 H1H4H1H5 H1FJ210 FJ208 FJ211Bk201 Bk201 VO1 VO2 VO3 VO4 FJ201 1' 0"2' 0" 1' 0" 1' 6 3/4"11 7/8"2' 5 3/8" 2' 0" 2' 0" 1' 0" 2' 0" 2' 4" 8' 11 7/8"11 3/4"Flush beam depth greater than floor joist depth. Verify all loading and framing conditions prior to construction.An additional 8 PSF area dead load has been addedto account for tile load in the MBA on this floor.There are different joist series of the same depth specified on this floor system.  Verify when installing that the proper TJI® joists are used in the appropriate area. 06/29/21