Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M003.0
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by 84 Components - 0783. June 8,2021 Liu, Xuegang Pages or sheets covered by this seal: I46466141 thru I46466188 My license renewal date for the state of Indiana is July 31, 2022. 25013-25013A TG140 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss A01 Truss Type Common Girder Qty 1 Ply 2 TG140 Job Reference (optional) I46466141 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:16:59 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-fBvPGmhgJ1ZthxtdS4xwa_?gPOVbT8KCQ_KKZnz8bQI Scale = 1:39.6 1 2 3 4 5 6 9 8 7 16 17 18 19 20 21 22 23 24 25 26 27 28 5x6 3x4 4x6 8x8 5x6 1.5x4 4x4 1.5x4 NAILED JUS24 NAILED NAILED NAILED JUS24 JUS24 JUS24 JUS24 6-7-5 6-7-5 13-2-11 6-7-6 19-10-0 6-7-5 -0-11-0 0-11-0 4-11-8 4-11-8 9-11-0 4-11-8 14-10-8 4-11-8 19-10-0 4-11-8 0-5-85-5-00-5-86.00 12 Plate Offsets (X,Y)-- [6:0-3-0,0-2-9], [7:0-4-0,0-4-4] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.45 0.47 0.38 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.17 0.02 0.06 (loc) 7-12 7-12 6 7-12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 185 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E *Except* 4-6: 2x4 SPF No.2 BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-0-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 2=0-3-8 Max Horz 2=77(LC 14) Max Uplift 6=-327(LC 15), 2=-296(LC 14) Max Grav 6=3176(LC 22), 2=2015(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3739/677, 3-4=-3584/677, 4-5=-4846/691, 5-6=-5014/692 BOT CHORD 2-9=-556/3318, 7-9=-330/2527, 6-7=-573/4485 WEBS 4-7=-300/3106, 5-7=-446/140, 4-9=-286/1074, 3-9=-373/137 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-11-0, Exterior(2R) 6-11-0 to 12-11-0, Interior(1) 12-11-0 to 16-10-0, Exterior(2E) 16-10-0 to 19-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6) Unbalanced snow loads have been considered for this design. 7) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 327 lb uplift at joint 6 and 296 lb uplift at joint 2. 11) Use MiTek JUS24 (With 4-10d nails into Girder & 2-10d nails into Truss) or equivalent spaced at 8-3-11 oc max. starting at 3-9-1 from the left end to 18-0-12 to connect truss(es) to front face of bottom chord. 12) Fill all nail holes where hanger is in contact with lumber. 13) "NAILED" indicates 3-10d Nails (0.148" x 3") toe-nails per NDS guidelines. Continued on page 2 June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss A01 Truss Type Common Girder Qty 1 Ply 2 TG140 Job Reference (optional) I46466141 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:16:59 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-fBvPGmhgJ1ZthxtdS4xwa_?gPOVbT8KCQ_KKZnz8bQI NOTES- 14) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 84 lb down and 48 lb up at 10-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-6=-60, 10-13=-20 Concentrated Loads (lb) Vert: 8=-65 21=-225(F) 22=-129(F) 23=-129(F) 24=-129(F) 25=-699(F) 26=-699(F) 27=-699(F) 28=-699(F) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss A02 Truss Type Common Qty 1 Ply 1 TG140 Job Reference (optional) I46466142 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:00 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-7OTnT5iI4KhkJ5Sq0nS97CYrjom0CcELee3u5Dz8bQH Scale = 1:35.5 1 2 3 4 5 6 7 14 15 16 17 4x6 4x6 5x9 4x4 1.5x4 1.5x4 9-11-0 9-11-0 19-10-0 9-11-0 -0-11-0 0-11-0 4-11-8 4-11-8 9-11-0 4-11-8 14-10-8 4-11-8 19-10-0 4-11-8 0-5-85-5-00-5-86.00 12 Plate Offsets (X,Y)-- [6:Edge,0-0-9], [7:0-4-8,0-3-4] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.41 0.78 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.15 -0.31 0.03 0.03 (loc) 7-10 7-10 6 7-10 l/defl >999 >759 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E *Except* 4-6: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-9-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)6=0-3-8, 2=0-3-8 Max Horz 2=77(LC 14) Max Uplift 6=-57(LC 15), 2=-73(LC 14) Max Grav 6=831(LC 22), 2=888(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1427/233, 3-4=-1015/164, 4-5=-1017/165, 5-6=-1420/238 BOT CHORD 2-7=-156/1237, 6-7=-163/1244 WEBS 4-7=-9/573, 5-7=-489/159, 3-7=-484/157 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-11-0, Exterior(2R) 6-11-0 to 12-11-0, Interior(1) 12-11-0 to 16-10-0, Exterior(2E) 16-10-0 to 19-10-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 57 lb uplift at joint 6 and 73 lb uplift at joint 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss A03 Truss Type Common Qty 5 Ply 1 TG140 Job Reference (optional) I46466143 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:01 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-ba19hRjwrepbxF10aVzOfP51oC6Jx3XVtIpRdfz8bQG Scale = 1:35.9 1 2 3 4 5 6 7 8 15 16 17 18 4x6 5x9 4x4 1.5x4 1.5x4 4x6 9-11-0 9-11-0 19-10-0 9-11-0 -0-11-0 0-11-0 4-11-8 4-11-8 9-11-0 4-11-8 14-10-8 4-11-8 19-10-0 4-11-8 20-9-0 0-11-0 0-5-85-5-00-5-86.00 12 Plate Offsets (X,Y)-- [8:0-4-8,0-3-4] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.33 0.78 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.15 -0.31 0.03 0.03 (loc) 8-11 8-11 6 8-11 l/defl >999 >776 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 68 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-11-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=71(LC 14) Max Uplift 2=-73(LC 14), 6=-73(LC 15) Max Grav 2=887(LC 21), 6=887(LC 22) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1425/230, 3-4=-1014/161, 4-5=-1014/161, 5-6=-1425/230 BOT CHORD 2-8=-132/1236, 6-8=-132/1236 WEBS 4-8=-5/572, 5-8=-484/157, 3-8=-484/157 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-11-0, Exterior(2R) 6-11-0 to 12-11-0, Interior(1) 12-11-0 to 17-9-0, Exterior(2E) 17-9-0 to 20-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 73 lb uplift at joint 2 and 73 lb uplift at joint 6. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss A04 Truss Type Hip Girder Qty 1 Ply 2 TG140 Job Reference (optional) I46466144 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:06 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-yXq2k9n3gARt10vzM2ZZMTos_DyJcO5E1aWCJtz8bQB Scale = 1:35.9 1 2 3 4 5 6 9 8 7 16 1718 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 4x6 3x6 4x6 2x4 4x4 5x6 3x6 NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED NAILED 7-1-0 7-1-0 12-9-0 5-8-0 19-10-0 7-1-0 -0-11-0 0-11-0 7-1-0 7-1-0 12-9-0 5-8-0 19-10-0 7-1-0 20-9-0 0-11-0 0-5-83-10-124-0-00-5-83-10-126.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-2-7] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.49 0.21 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.05 -0.08 0.01 0.03 (loc) 7-15 7-15 5 7-15 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 177 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 5=0-3-8 Max Horz 2=52(LC 64) Max Uplift 2=-163(LC 14), 5=-163(LC 15) Max Grav 2=1636(LC 39), 5=1636(LC 39) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2511/357, 3-4=-2089/361, 4-5=-2506/355 BOT CHORD 2-9=-227/2112, 7-9=-231/2093, 5-7=-226/2108 WEBS 3-9=0/516, 4-7=0/514 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 2-10-1, Exterior(2R) 2-10-1 to 16-11-15, Interior(1) 16-11-15 to 17-9-0, Exterior(2E) 17-9-0 to 20-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6) Unbalanced snow loads have been considered for this design. 7) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 8) Provide adequate drainage to prevent water ponding. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 163 lb uplift at joint 2 and 163 lb uplift at joint 5. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) "NAILED" indicates 3-10d Nails (0.148" x 3") toe-nails per NDS guidelines. LOAD CASE(S) StandardContinued on page 2 June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss A04 Truss Type Hip Girder Qty 1 Ply 2 TG140 Job Reference (optional) I46466144 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:06 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-yXq2k9n3gARt10vzM2ZZMTos_DyJcO5E1aWCJtz8bQB LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 4-6=-60, 10-13=-20 Concentrated Loads (lb) Vert: 4=-70(B) 9=-46(B) 7=-46(B) 3=-70(B) 18=-47(B) 21=-70(B) 22=-70(B) 25=-47(B) 28=-135(B) 29=-133(B) 30=-46(B) 31=-46(B) 32=-133(B) 33=-135(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss B01 Truss Type Hip Girder Qty 1 Ply 2 TG140 Job Reference (optional) I46466145 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:08 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-uwyp9roJCohbHK3MUTb1Sut7?1e34IaXUu?JNlz8bQ9 Scale = 1:32.8 1 2 3 4 5 6 9 8 7 16 17 18 19 20 21 22 23 5x6 3x4 4x6 2x4 4x4 5x6 3x4 NAILED NAILED NAILED NAILED JUS24 NAILED NAILED JUS24 4-10-8 4-10-8 13-1-8 8-3-0 18-0-0 4-10-8 -0-11-0 0-11-0 4-10-8 4-10-8 13-1-8 8-3-0 18-0-0 4-10-8 18-11-0 0-11-0 0-7-53-9-13-10-50-7-53-9-18.00 12 Plate Offsets (X,Y)-- [3:0-3-0,0-2-3], [4:0-3-0,0-2-3], [5:0-1-9,0-1-8] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.78 0.19 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.04 -0.09 0.01 0.03 (loc) 7-9 7-9 5 7-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 169 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-4: 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 5=0-3-8 Max Horz 2=-74(LC 38) Max Uplift 2=-123(LC 12), 5=-189(LC 13) Max Grav 2=1079(LC 1), 5=1320(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1644/226, 3-4=-1563/297, 4-5=-1943/301 BOT CHORD 2-9=-172/1328, 7-9=-176/1316, 5-7=-206/1581 WEBS 3-9=0/405, 3-7=-179/327, 4-7=0/525 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 15-11-0, Exterior(2E) 15-11-0 to 18-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 5) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 7) Provide adequate drainage to prevent water ponding. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 123 lb uplift at joint 2 and 189 lb uplift at joint 5. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) Use MiTek JUS24 (With 4-10d nails into Girder & 2-10d nails into Truss) or equivalent at 9-4-12 from the left end to connect truss(es) to back face of bottom chord. Continued on page 2 June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss B01 Truss Type Hip Girder Qty 1 Ply 2 TG140 Job Reference (optional) I46466145 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:08 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-uwyp9roJCohbHK3MUTb1Sut7?1e34IaXUu?JNlz8bQ9 NOTES- 13) Use MiTek JUS24 (With 4-10d nails into Girder & 2-10d nails into Truss) or equivalent at 15-0-12 from the left end to connect truss(es) to back face of bottom chord, skewed 0.0 deg.to the left, sloping 0.0 deg. down. 14) Fill all nail holes where hanger is in contact with lumber. 15) "NAILED" indicates 3-10d Nails (0.148" x 3") toe-nails per NDS guidelines. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 4-6=-60, 10-13=-20 Concentrated Loads (lb) Vert: 4=-64(B) 7=-43(B) 17=-125(B) 18=-64(B) 21=-288(B) 22=-43(B) 23=-222(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss B02 Truss Type Hip Qty 1 Ply 1 TG140 Job Reference (optional) I46466146 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:09 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-M6WBMApxz5pSuUeY2A6G_5QMJQx8pkYgjYlsvCz8bQ8 Scale = 1:34.7 1 2 3 4 5 6 9 8 7 16 17 18 19 5x6 4x6 3x6 1.5x4 4x4 6x6 4x6 7-0-0 7-0-0 11-0-0 4-0-0 18-0-0 7-0-0 -0-11-0 0-11-0 7-0-0 7-0-0 11-0-0 4-0-0 18-0-0 7-0-0 18-11-0 0-11-0 0-7-55-1-85-3-50-7-55-1-88.00 12 Plate Offsets (X,Y)-- [3:0-3-5,Edge], [4:0-3-0,0-2-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.55 0.40 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.05 -0.11 0.02 0.06 (loc) 9-12 9-12 2 9-12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 66 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-2-11 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 5=0-3-8 Max Horz 2=101(LC 11) Max Uplift 2=-52(LC 12), 5=-52(LC 13) Max Grav 2=775(LC 1), 5=775(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-909/104, 3-4=-664/132, 4-5=-910/104 BOT CHORD 2-9=-6/668, 7-9=-8/664, 5-7=0/668 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 2-9-1, Exterior(2R) 2-9-1 to 15-2-15, Interior(1) 15-2-15 to 15-11-0, Exterior(2E) 15-11-0 to 18-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 lb uplift at joint 2 and 52 lb uplift at joint 5. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss B03 Truss Type Common Qty 9 Ply 1 TG140 Job Reference (optional) I46466147 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:10 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-qJ4ZaWqZkPxJWdDlbudVXJzduqDXYAkpyCUPSez8bQ7 Scale = 1:41.4 1 2 3 4 5 6 7 9 8 16 17 18 19 4x6 3x6 4x8 4x4 1.5x4 1.5x4 4x6 9-0-0 9-0-0 18-0-0 9-0-0 -0-11-0 0-11-0 4-6-0 4-6-0 9-0-0 4-6-0 13-6-0 4-6-0 18-0-0 4-6-0 18-11-0 0-11-0 0-7-56-7-50-7-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.17 0.58 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.18 0.02 0.01 (loc) 9-12 9-12 6 9-12 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 68 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 6=0-3-8 Max Horz 2=-128(LC 10) Max Uplift 2=-61(LC 12), 6=-61(LC 13) Max Grav 2=775(LC 1), 6=775(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-954/107, 3-4=-732/93, 4-5=-732/93, 5-6=-954/107 BOT CHORD 2-9=-91/751, 6-9=-16/748 WEBS 4-9=-0/505, 5-9=-270/140, 3-9=-270/140 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-0-0, Exterior(2R) 6-0-0 to 12-0-0, Interior(1) 12-0-0 to 15-11-0, Exterior(2E) 15-11-0 to 18-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 61 lb uplift at joint 2 and 61 lb uplift at joint 6. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss B04 Truss Type Roof Special Qty 4 Ply 1 TG140 Job Reference (optional) I46466148 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:11 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-IVexnsrBVj3A8nox9b8k3WVnCEYsHZlzArEz_4z8bQ6 Scale = 1:41.5 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 22 23 24 4x6 2x4 5x6 8x8 2x4 1.5x4 4x6 4x6 4x4 5x12 MT18HS 4x8 5x9 1.5x4 1-11-13 1-11-13 3-11-0 1-11-3 7-3-0 3-4-0 9-0-0 1-9-0 18-0-0 9-0-0 -0-11-0 0-11-0 1-11-13 1-11-13 3-11-0 1-11-3 7-3-0 3-4-0 9-0-0 1-9-0 13-6-0 4-6-0 18-0-0 4-6-0 18-11-0 0-11-0 0-7-56-7-50-7-52-0-08.00 12 Plate Offsets (X,Y)-- [12:0-2-8,0-3-0], [13:0-3-12,0-0-0] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.20 0.70 0.42 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.12 -0.25 0.16 0.07 (loc) 10-21 10-21 8 12-13 l/defl >999 >850 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 89 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-0-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 11-12,10-11. REACTIONS. (size)2=0-3-8, 8=0-3-8 Max Horz 2=-128(LC 10) Max Uplift 2=-61(LC 12), 8=-61(LC 13) Max Grav 2=775(LC 1), 8=775(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-948/62, 3-4=-2861/265, 4-5=-1230/90, 5-6=-1175/142, 6-7=-729/95, 7-8=-954/110 BOT CHORD 2-15=-95/762, 4-13=-89/1156, 12-13=-251/2515, 8-10=-18/749 WEBS 3-15=-757/112, 13-15=-113/915, 3-13=-149/1699, 4-12=-1563/229, 10-12=0/826, 6-12=-128/1217, 6-10=-357/64, 7-10=-274/138 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 1-10-7, Interior(1) 1-10-7 to 6-0-0, Exterior(2R) 6-0-0 to 12-0-0, Interior(1) 12-0-0 to 15-11-0, Exterior(2E) 15-11-0 to 18-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 61 lb uplift at joint 2 and 61 lb uplift at joint 8. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss B05 Truss Type Common Qty 1 Ply 1 TG140 Job Reference (optional) I46466149 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:12 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-mhCJ?CrpF0B1lxN7jJgzck2yZevx04A6PVzWWXz8bQ5 Scale = 1:40.8 1 2 3 4 5 6 8 7 15 16 17 18 3x6 4x4 1.5x4 4x8 1.5x4 4x6 4x6 9-0-0 9-0-0 18-0-0 9-0-0 4-6-0 4-6-0 9-0-0 4-6-0 13-6-0 4-6-0 18-0-0 4-6-0 18-11-0 0-11-0 0-7-56-7-50-7-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.23 0.58 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.19 0.02 0.02 (loc) 8-11 8-11 5 8-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-6: 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-10-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=0-3-8, 5=0-3-8 Max Horz 1=-124(LC 10) Max Uplift 1=-45(LC 12), 5=-61(LC 13) Max Grav 1=719(LC 1), 5=776(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-959/110, 2-3=-736/94, 3-4=-735/94, 4-5=-957/109 BOT CHORD 1-8=-93/757, 5-8=-17/750 WEBS 3-8=-3/506, 4-8=-270/140, 2-8=-274/142 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-0-0, Exterior(2R) 6-0-0 to 12-0-0, Interior(1) 12-0-0 to 15-11-0, Exterior(2E) 15-11-0 to 18-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 45 lb uplift at joint 1 and 61 lb uplift at joint 5. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss B06 Truss Type Common Qty 4 Ply 1 TG140 Job Reference (optional) I46466150 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:12 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-mhCJ?CrpF0B1lxN7jJgzck2yZevx04A6PVzWWXz8bQ5 Scale = 1:40.8 1 2 3 4 5 6 8 7 15 16 17 18 3x6 4x4 1.5x4 4x8 1.5x4 4x6 4x6 9-0-0 9-0-0 18-0-0 9-0-0 4-6-0 4-6-0 9-0-0 4-6-0 13-6-0 4-6-0 18-0-0 4-6-0 18-11-0 0-11-0 0-7-56-7-50-7-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MSH 0.23 0.58 0.15 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.19 0.02 0.02 (loc) 8-11 8-11 5 8-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 67 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 3-6: 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-10-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=Mechanical, 5=0-3-8 Max Horz 1=-124(LC 10) Max Uplift 1=-45(LC 12), 5=-61(LC 13) Max Grav 1=719(LC 1), 5=776(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-959/110, 2-3=-736/94, 3-4=-735/94, 4-5=-957/109 BOT CHORD 1-8=-93/757, 5-8=-17/750 WEBS 3-8=-3/506, 4-8=-270/140, 2-8=-274/142 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-0-0, Exterior(2R) 6-0-0 to 12-0-0, Interior(1) 12-0-0 to 15-11-0, Exterior(2E) 15-11-0 to 18-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 45 lb uplift at joint 1 and 61 lb uplift at joint 5. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss B07 Truss Type GABLE Qty 1 Ply 1 TG140 Job Reference (optional) I46466151 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:14 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-j4J4Put4neSl?FXWqjiRh97KbRkqU_oPspSdbPz8bQ3 Scale = 1:41.4 1 2 3 4 5 6 7 8 9 10 11 12 1314 26 25 24 23 22 21 2019 18 17 16 15 27 4x4 3x6 4x6 4x6 18-0-0 18-0-0 9-0-0 9-0-0 18-0-0 9-0-0 18-11-0 0-11-0 0-7-56-7-50-7-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-SH 0.07 0.04 0.08 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 13 13 13 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 93 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 *Except* 7-14: 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 18-0-0. (lb) - Max Horz 1=-126(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 22, 23, 24, 25, 26, 1, 19, 18, 17, 16, 15 Max Grav All reactions 250 lb or less at joint(s) 21, 22, 23, 24, 25, 26, 1, 13, 19, 18, 17, 16, 15 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) 0-0-0 to 3-0-0, Exterior(2N) 3-0-0 to 6-0-0, Corner(3R) 6-0-0 to 12-0-0, Exterior(2N) 12-0-0 to 15-8-0, Corner(3E) 15-8-0 to 18-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 23, 24, 25, 26, 1, 19, 18, 17, 16, 15. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss C01 Truss Type GABLE Qty 1 Ply 1 TG140 Job Reference (optional) I46466152 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:15 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-BGtSdEuiYxaccP5iORDgEMgU0r4KDSwZ5TCA7rz8bQ2 Scale = 1:23.5 1 2 3 4 5 6 7 8 9 14 13 12 11 10 4x4 4x4 4x4 9-4-0 9-4-0 -0-11-0 0-11-0 4-8-0 4-8-0 9-4-0 4-8-0 10-3-0 0-11-0 0-7-53-8-100-7-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.03 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 8 9 8 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 39 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 9-4-0. (lb) - Max Horz 2=72(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 8, 13, 14, 11, 10 Max Grav All reactions 250 lb or less at joint(s) 2, 8, 12, 13, 14, 11, 10 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-0-0, Corner(3R) 2-0-0 to 7-4-0, Corner(3E) 7-4-0 to 10-3-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8, 13, 14, 11, 10. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss C02 Truss Type Common Qty 2 Ply 1 TG140 Job Reference (optional) I46466153 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:16 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-fTRqqavKJFiSEYguy8kvmaCdIFMdyvliK7xkfIz8bQ1 Scale = 1:24.6 1 2 3 4 5 4x4 1.5x4 4x4 4x4 4-8-0 4-8-0 9-4-0 4-8-0 -0-11-0 0-11-0 4-8-0 4-8-0 9-4-0 4-8-0 0-7-53-8-100-7-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.24 0.21 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.03 0.01 0.02 (loc) 5-11 5-11 2 5-11 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 30 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=Mechanical Max Horz 2=68(LC 9) Max Uplift 2=-40(LC 12), 4=-22(LC 13) Max Grav 2=431(LC 1), 4=371(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-412/95, 3-4=-410/94 BOT CHORD 2-5=-3/276, 4-5=-3/276 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 6-4-0, Exterior(2E) 6-4-0 to 9-4-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss CJ01 Truss Type Diagonal Hip Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466154 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:17 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-7f?C2vvy4ZqJsiF5WsF8JnlhJfgUhMLrZnhHBkz8bQ0 Scale = 1:15.0 1 2 5 6 7 3 8 9 4 5x9 NAILED NAILED NAILED NAILED -1-5-10 1-5-10 3-3-2 3-3-2 5-11-15 2-8-13 0-3-100-6-42-5-90-1-11-7-42-5-93.12 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.67 0.37 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.12 -0.00 0.00 (loc) 4-5 4-5 3 5 l/defl >999 >572 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-11-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 4=Mechanical, 2=0-1-14 Max Horz 2=63(LC 10) Max Uplift 3=-61(LC 14), 2=-90(LC 10) Max Grav 3=211(LC 21), 4=112(LC 7), 2=468(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -1-5-10 to 2-9-5, Exterior(2R) 2-9-5 to 5-11-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 10) Non Standard bearing condition. Review required. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 12) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 13) "NAILED" indicates 3-10d skew 45 to 135 degrees (0.148" x 3") toe-nails per NDS guidelines. 14) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 4-5=-20 June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss CJ02 Truss Type Jack-Open Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466155 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:18 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-brZbFFwarsyATsqH3ZmNr?IyU33jQp_?nRQrkAz8bQ? Scale = 1:14.1 1 2 3 4 4x8 4-1-4 4-0-12 -1-6-5 1-6-5 4-1-4 4-1-4 0-7-52-3-01-10-102-3-04.80 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.26 0.17 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.03 0.01 0.01 (loc) 4-7 4-7 3 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-1-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 4=Mechanical, 2=0-4-13 Max Horz 2=65(LC 14) Max Uplift 3=-39(LC 14), 2=-45(LC 10) Max Grav 3=142(LC 21), 4=71(LC 7), 2=385(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -1-6-5 to 2-8-9, Exterior(2R) 2-8-9 to 4-0-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss CJ03 Truss Type Jack-Open Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466156 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:18 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-brZbFFwarsyATsqH3ZmNr?Ix033AQpk?nRQrkAz8bQ? Scale = 1:12.6 1 2 5 6 3 4 5x9 -1-5-10 1-5-10 4-0-9 4-0-9 0-3-100-6-41-11-80-1-10-6-53.12 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.36 0.14 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.02 -0.00 0.00 (loc) 4-5 4-5 3 5 l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-0-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-1-14, 4=Mechanical Max Horz 2=48(LC 10) Max Uplift 3=-35(LC 14), 2=-87(LC 10) Max Grav 3=115(LC 21), 2=379(LC 21), 4=73(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -1-5-10 to 2-9-5, Exterior(2R) 2-9-5 to 3-11-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 10) Non Standard bearing condition. Review required. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 12) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss CJ04 Truss Type Diagonal Hip Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466157 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:19 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-317zTbxDcA4150PTdHIcOCq8WSP29GD805AOGdz8bQ_ Scale = 1:15.2 1 2 3 4 1.5x4 1.5x4 4x6 3-11-5 3-11-5 -1-3-9 1-3-9 3-11-5 3-11-5 0-7-52-5-105.66 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.25 0.17 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.02 0.01 0.01 (loc) 4-7 4-7 2 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-11-5 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-4-9 Max Horz 2=71(LC 13) Max Uplift 4=-23(LC 14), 2=-37(LC 14) Max Grav 4=193(LC 21), 2=354(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -1-3-9 to 2-11-6, Exterior(2R) 2-11-6 to 3-9-9 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss CJ05 Truss Type Jack-Open Girder Qty 2 Ply 1 TG140 Job Reference (optional) I46466158 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:20 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-XEgLgxyrNUCujA_gB_prxQNI5smUujTIFlvxn3z8bPz Scale = 1:12.6 1 2 3 4 4x8 3-4-2 3-3-10 -1-6-5 1-6-5 3-4-2 3-4-2 0-7-51-11-64.80 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.26 0.09 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in 0.01 -0.01 0.00 -0.00 (loc) 4-7 4-7 3 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-4-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 4=Mechanical, 2=0-4-13 Max Horz 2=56(LC 14) Max Uplift 3=-30(LC 14), 2=-46(LC 10) Max Grav 3=108(LC 21), 4=56(LC 7), 2=348(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3) -1-6-5 to 2-8-9, Exterior(2R) 2-8-9 to 3-3-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ01 Truss Type Jack-Open Qty 4 Ply 1 TG140 Job Reference (optional) I46466159 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:20 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-XEgLgxyrNUCujA_gB_prxQNH2sk5ujTIFlvxn3z8bPz Scale = 1:23.1 1 2 3 44x4 5-1-1 5-1-1 -0-11-0 0-11-0 5-1-1 5-1-1 0-7-54-0-03-6-134-0-08.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.32 0.24 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.03 -0.07 0.01 0.04 (loc) 4-7 4-7 2 4-7 l/defl >999 >908 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-1-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=117(LC 12) Max Uplift 3=-71(LC 12), 2=-3(LC 12) Max Grav 3=134(LC 20), 2=261(LC 1), 4=94(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ02 Truss Type Jack-Open Qty 2 Ply 1 TG140 Job Reference (optional) I46466160 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:21 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-?QEjtHyT8nKlKKZsliK4TdwUdG28dALRTPfVJVz8bPy Scale = 1:18.8 1 2 3 6 4 5 4x4 4x6 1.5x4 3-7-1 3-7-1 5-1-0 1-6-0 -0-11-0 0-11-0 3-7-1 3-7-1 5-1-0 1-6-0 0-7-53-0-02-8-83-0-08.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.21 0.38 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.04 -0.09 0.06 0.05 (loc) 6-9 6-9 4 6-9 l/defl >999 >655 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-1-0 oc purlins, except 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-3-8, 5=Mechanical Max Horz 2=89(LC 12) Max Uplift 4=-16(LC 8), 2=-18(LC 12), 5=-23(LC 12) Max Grav 4=43(LC 1), 2=261(LC 1), 5=153(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2, 5. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ03 Truss Type Jack-Open Qty 2 Ply 1 TG140 Job Reference (optional) I46466161 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:22 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-Uco55dz5v5ScyT82IPrJ0rSe?gPvMdzai3O2sxz8bPx Scale = 1:22.2 1 2 3 44x4 4-10-8 4-10-8 -0-11-0 0-11-0 4-10-8 4-10-8 0-7-53-10-53-5-23-10-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.29 0.22 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.06 0.01 0.03 (loc) 4-7 4-7 2 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-10-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=113(LC 12) Max Uplift 3=-68(LC 12), 2=-3(LC 12) Max Grav 3=129(LC 20), 2=253(LC 1), 4=90(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ04 Truss Type Jack-Open Qty 3 Ply 1 TG140 Job Reference (optional) I46466162 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:22 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-Uco55dz5v5ScyT82IPrJ0rSgogQEMdiai3O2sxz8bPx Scale = 1:19.5 1 2 3 4 1.5x4 4x4 1.5x4 4-0-8 4-0-8 -0-11-0 0-11-0 4-0-8 4-0-8 0-7-53-3-108.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.18 0.14 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.02 0.01 0.01 (loc) 4-7 4-7 2 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-0-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=Mechanical Max Horz 2=94(LC 12) Max Uplift 2=-5(LC 12), 4=-49(LC 12) Max Grav 2=217(LC 1), 4=155(LC 20) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ05 Truss Type Jack-Open Qty 1 Ply 1 TG140 Job Reference (optional) I46466163 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:23 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-ypMUIz_jgPaTadjFs6MYY2?qk4mK54Dkxj8bOOz8bPw Scale = 1:14.4 1 2 3 4 2x4 3-8-5 3-8-5 -0-11-0 0-11-0 3-8-5 3-8-5 0-5-82-3-101-11-02-3-106.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.23 0.15 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.02 0.00 0.01 (loc) 4-7 4-7 2 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 10 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-8-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=67(LC 14) Max Uplift 3=-42(LC 14), 2=-20(LC 14) Max Grav 3=140(LC 21), 2=298(LC 21), 4=67(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ06 Truss Type Jack-Open Qty 2 Ply 1 TG140 Job Reference (optional) I46466164 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:24 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-Q?wsWJ?LRiiKBnIRQqtn5GY0qT7RqXTtANt9wqz8bPv Scale = 1:12.9 1 2 3 4 2x4 3-1-0 3-1-0 -0-11-0 0-11-0 3-1-0 3-1-0 0-5-82-0-01-7-52-0-06.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.14 0.09 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.01 0.00 0.00 (loc) 4-7 4-7 2 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-1-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=58(LC 14) Max Uplift 3=-34(LC 14), 2=-20(LC 14) Max Grav 3=112(LC 21), 2=261(LC 21), 4=55(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ07 Truss Type Jack-Open Qty 1 Ply 1 TG140 Job Reference (optional) I46466165 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:24 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-Q?wsWJ?LRiiKBnIRQqtn5GY1jT8sqXTtANt9wqz8bPv Scale = 1:15.6 1 2 3 4 4x4 2-10-8 2-10-8 -0-11-0 0-11-0 2-10-8 2-10-8 0-7-52-6-52-1-22-6-58.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.09 0.06 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.01 0.00 0.00 (loc) 4-7 4-7 3 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 9 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 2-10-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=73(LC 12) Max Uplift 3=-38(LC 12), 2=-8(LC 12) Max Grav 3=71(LC 20), 2=176(LC 1), 4=51(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ08 Truss Type Jack-Open Qty 2 Ply 1 TG140 Job Reference (optional) I46466166 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:25 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-uBUEjf?zC0qBpxsd_XO0eT4BXtUKZ_Y1O1diSGz8bPu Scale = 1:13.0 1 2 5 3 4 1.5x4 4x4 -0-11-0 0-11-0 2-7-8 2-7-8 0-3-130-6-72-0-30-0-121-1-42-0-35.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.15 0.05 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 4-5 4-5 3 5 l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 8 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 2-7-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 4=Mechanical, 2=0-1-12 Max Horz 2=42(LC 14) Max Uplift 3=-24(LC 14), 2=-35(LC 10) Max Grav 3=70(LC 21), 4=45(LC 7), 2=251(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 10) Non Standard bearing condition. Review required. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 12) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ09 Truss Type Jack-Open Qty 1 Ply 1 TG140 Job Reference (optional) I46466167 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:26 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-MO2cx_0cyKy2R5RpXFwFAhdMKHqiIRpAdhMG?jz8bPt Scale = 1:11.5 1 2 5 3 4 5x9 -0-11-0 0-11-0 2-5-1 2-5-1 0-3-110-7-41-8-100-9-31-8-104.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.14 0.04 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 4-5 4-5 3 5 l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 2-5-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 4=Mechanical, 2=0-1-12 Max Horz 2=37(LC 10) Max Uplift 3=-19(LC 14), 2=-58(LC 10) Max Grav 3=56(LC 21), 4=41(LC 7), 2=234(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 10) Non Standard bearing condition. Review required. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 12) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss EJ10 Truss Type Jack-Open Qty 1 Ply 1 TG140 Job Reference (optional) I46466168 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:26 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-MO2cx_0cyKy2R5RpXFwFAhdMMHqrIRqAdhMG?jz8bPt Scale: 1"=1' 1 2 5 3 4 1.5x4 4x4 -0-11-0 0-11-0 2-1-12 2-1-12 0-3-130-6-71-9-120-0-120-6-85.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.14 0.03 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.00 -0.00 -0.00 0.00 (loc) 5 4-5 3 5 l/defl >999 >999 n/a **** L/d 360 240 n/a 240 PLATES MT20 Weight: 7 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 2-1-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=Mechanical, 4=Mechanical, 2=0-1-12 Max Horz 2=36(LC 14) Max Uplift 3=-21(LC 20), 2=-38(LC 10) Max Grav 3=44(LC 21), 4=37(LC 7), 2=230(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 10) Non Standard bearing condition. Review required. 11) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 12) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss LAY1 Truss Type GABLE Qty 1 Ply 1 TG140 Job Reference (optional) I46466169 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:27 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-qac_8K1Ejd4v2F005yRUjuAZRhA91uoKsL6pX9z8bPs Scale = 1:33.0 1 2 3 4 5 8 7 62x4 4x4 2x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 8-0-10 8-0-10 4-0-5 4-0-5 8-0-10 4-0-5 0-0-44-10-10-0-414.42 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.02 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 32 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 8-0-10. (lb) - Max Horz 1=-91(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 8=-126(LC 12), 6=-126(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7, 8, 6 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) 0-3-12 to 3-3-12, Exterior(2R) 3-3-12 to 4-8-14, Exterior(2E) 4-8-14 to 7-8-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb) 8=126, 6=126. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss LAY2 Truss Type GABLE Qty 1 Ply 1 TG140 Job Reference (optional) I46466170 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:28 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-Im9NLg2sUxClgObCfgyjF6ijk5W2mLFT4?rM3bz8bPr Scale = 1:17.4 1 2 3 4 2x4 4x4 2x4 1.5x4 5-4-15 5-4-15 2-8-8 2-8-8 5-4-15 2-8-8 0-0-42-5-40-0-410.82 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.09 0.05 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-4-15 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=5-4-15, 3=5-4-15, 4=5-4-15 Max Horz 1=-41(LC 8) Max Uplift 1=-18(LC 13), 3=-21(LC 13) Max Grav 1=108(LC 1), 3=108(LC 1), 4=156(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss M01 Truss Type GABLE Qty 1 Ply 1 TG140 Job Reference (optional) I46466171 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:29 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-mzjlZ03UFFLcIYAODNTyoJFsgUquVo?cJfbwc1z8bPq Scale = 1:29.6 1 2 3 4 5 6 7 8 14 13 12 11 10 9 15 16 2x4 -0-11-0 0-11-0 10-0-0 10-0-0 0-5-85-5-86.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.20 0.07 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 9 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 10-0-0. (lb) - Max Horz 2=161(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 9, 10, 11, 12, 13, 14 Max Grav All reactions 250 lb or less at joint(s) 9, 2, 10, 11, 12, 13 except 14=259(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) -0-11-0 to 2-1-0, Exterior(2N) 2-1-0 to 6-10-4, Corner(3E) 6-10-4 to 9-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 10, 11, 12, 13, 14. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss M02 Truss Type Monopitch Qty 6 Ply 1 TG140 Job Reference (optional) I46466172 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:30 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-mzjlZ03UFFLcIYAODNTyoJFoKUlyVk0cJfbwc0z8bPq Scale = 1:33.1 1 2 3 4 5 9 10 1.5x4 4x6 1.5x4 3x4 -0-11-0 0-11-0 5-0-0 5-0-0 10-0-0 5-0-0 0-5-85-5-85-2-00-3-85-5-86.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-5] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.48 0.39 0.30 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.24 -0.49 0.01 0.02 (loc) 5-8 5-8 2 5-8 l/defl >492 >243 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 41 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SP DSS WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 5=0-1-8 Max Horz 2=162(LC 13) Max Uplift 2=-45(LC 14), 5=-68(LC 14) Max Grav 2=494(LC 21), 5=516(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-563/153 BOT CHORD 2-5=-126/491 WEBS 3-5=-552/224 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 6-10-4, Exterior(2E) 6-10-4 to 9-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 5. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 5. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss M03 Truss Type Monopitch Qty 2 Ply 1 TG140 Job Reference (optional) I46466173 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:30 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-F9H7mM360YTTvilbm5_BLXoxEu67EFzmYJKT8Uz8bPp Scale = 1:17.0 1 2 3 5 4 6 7 8 4x4 5x9 3x4 3x4 6-0-0 6-0-0 -0-11-0 0-11-0 6-0-0 6-0-0 0-3-110-7-42-10-152-0-30-3-82-10-154.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MR 0.60 0.33 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.06 -0.11 0.18 0.03 (loc) 4-5 4-5 7 4-5 l/defl >999 >590 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 20 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 7=0-1-8 Max Horz 2=57(LC 10) Max Uplift 2=-62(LC 10), 7=-31(LC 14) Max Grav 2=418(LC 21), 7=253(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 5-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 7. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 11) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss M04 Truss Type Monopitch Qty 6 Ply 1 TG140 Job Reference (optional) I46466174 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:31 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-jLrV_i4knsbKXsKnKoVQtkK9WIUHzhbvnz41gwz8bPo Scale = 1:13.1 1 2 3 5 4 6 7 8 3x4 5x9 3x4 3x4 5-0-0 5-0-0 -0-11-0 0-11-0 5-0-0 5-0-0 0-3-110-7-42-6-151-8-30-3-82-6-154.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MR 0.37 0.20 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.03 -0.05 0.08 0.01 (loc) 4-5 4-5 7 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 17 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 7=0-1-8 Max Horz 2=47(LC 10) Max Uplift 2=-59(LC 10), 7=-24(LC 14) Max Grav 2=367(LC 21), 7=197(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 4-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 7. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 11) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss M05 Truss Type Monopitch Qty 3 Ply 1 TG140 Job Reference (optional) I46466175 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:32 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-BYPtB25MYAjB90vzuV0fQytNhisMi883?dpaCMz8bPn Scale = 1:12.6 1 2 3 5 4 6 7 8 3x4 1.5x4 1.5x4 4x4 3x4 3-8-0 3-8-0 -0-11-0 0-11-0 3-8-0 3-8-0 0-3-130-6-72-5-60-0-121-7-60-3-82-5-65.00 12 Plate Offsets (X,Y)-- [2:0-2-0,0-1-12] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MR 0.15 0.09 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.01 0.02 0.00 (loc) 4-5 4-5 7 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 7=0-1-8 Max Horz 2=41(LC 11) Max Uplift 2=-34(LC 14), 7=-16(LC 14) Max Grav 2=302(LC 21), 7=121(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Interior(1) 2-1-0 to 3-2-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 7. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 7. 10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 11) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss M06 Truss Type Monopitch Qty 3 Ply 1 TG140 Job Reference (optional) I46466176 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:32 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-BYPtB25MYAjB90vzuV0fQytM0irSi8R3?dpaCMz8bPn Scale = 1:12.4 1 2 3 4 1.5x4 2x4 1.5x4 3-8-0 3-8-0 -0-11-0 0-11-0 3-8-0 3-8-0 0-4-91-10-141-7-60-3-81-10-145.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.20 0.14 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.02 0.00 0.01 (loc) 4-7 4-7 2 4-7 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 4=0-1-8 Max Horz 2=55(LC 13) Max Uplift 2=-31(LC 14), 4=-20(LC 14) Max Grav 2=284(LC 21), 4=181(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss M07 Truss Type GABLE Qty 1 Ply 1 TG140 Job Reference (optional) I46466177 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:33 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-fkzGPO6?JTr2mAUASDYuy9PWl6C1RbhCEHZ7lpz8bPm Scale = 1:12.4 1 2 3 4 1.5x4 1.5x4 2x4 -0-11-0 0-11-0 3-8-0 3-8-0 0-4-91-10-145.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.26 0.12 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 4 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 3-8-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=3-8-0, 2=3-8-0 Max Horz 2=55(LC 13) Max Uplift 4=-20(LC 14), 2=-31(LC 14) Max Grav 4=181(LC 21), 2=284(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Corner(3E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss M08 Truss Type Rafter Qty 9 Ply 1 TG140 Job Reference (optional) I46466178 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:34 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-7wXeck6d4nzvOJ2M?w37VNykVVZAA2sMTxIhHFz8bPl Scale = 1:7.1 1 5 2 3 4 6x6 0-11-0 0-11-0 1-8-4 0-9-4 1-9-0 0-0-12 1-9-0 1-9-0 0-3-151-2-70-3-156.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.07 0.00 0.01 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in 0.00 0.00 0.00 -0.00 (loc) 2 2 2 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 4 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-4: 2x4 SP DSS BRACING- TOP CHORD Sheathed or 1-9-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-3-8, 4=Mechanical Max Horz 2=22(LC 14) Max Uplift 2=-36(LC 14), 4=-22(LC 20) Max Grav 2=149(LC 20), 4=9(LC 10) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss MG01 Truss Type Jack-Open Girder Qty 2 Ply 1 TG140 Job Reference (optional) I46466179 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:34 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-7wXeck6d4nzvOJ2M?w37VNyi6VOHA2QMTxIhHFz8bPl Scale = 1:14.3 1 2 3 6 10 4 11 5 4x4 4x6 1.5x4 NAILED NAILED NAILED NAILED 2-1-0 2-1-0 5-1-0 3-0-0 -0-11-0 0-11-0 2-1-0 2-1-0 5-1-0 3-0-0 0-7-52-0-01-8-82-0-08.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.22 0.76 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.09 -0.16 0.13 0.06 (loc) 5-6 5-6 4 6 l/defl >670 >373 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-1-0 oc purlins, except 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-3-8, 5=Mechanical Max Horz 2=59(LC 41) Max Uplift 4=-36(LC 8), 2=-35(LC 12) Max Grav 4=107(LC 1), 2=316(LC 1), 5=155(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-252/96 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) "NAILED" indicates 3-10d skew 45 to 135 degrees (0.148" x 3") toe-nails per NDS guidelines. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 3=-33(F) 6=-15(F) 10=-52(F) 11=-22(F) June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss MG02 Truss Type Jack-Open Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466180 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:35 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-b640p37Fr55m0TdYZeaM2aVlZvh_vVBVha2Ephz8bPk Scale = 1:15.4 1 2 3 4 9 5 3x4 6x8 NAILED Special 2-10-8 2-10-8 4-10-8 2-0-0 -0-11-0 0-11-0 2-10-8 2-10-8 4-10-8 2-0-0 0-7-52-6-52-2-132-6-58.00 12 Plate Offsets (X,Y)-- [2:0-0-1,Edge], [3:0-2-0,0-2-3] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.75 0.86 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.14 -0.24 0.51 0.12 (loc) 5-8 5-8 4 5-8 l/defl >407 >240 n/a >465 L/d 360 240 n/a 240 PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-10-8 oc purlins, except 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-3-8, 5=Mechanical Max Horz 2=75(LC 41) Max Uplift 4=-21(LC 8), 2=-45(LC 12), 5=-45(LC 12) Max Grav 4=58(LC 1), 2=328(LC 1), 5=242(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2, 5. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) "NAILED" indicates 3-10d Nails (0.148" x 3") toe-nails per NDS guidelines. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 180 lb down and 52 lb up at 2-10-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 5-6=-20 Concentrated Loads (lb) Vert: 3=-8(B) 9=-180(B)June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss MG03 Truss Type Jack-Open Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466181 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:36 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-3JeO1P8tcODdedCk7L5bao1wpJ?GeyRewEnnL8z8bPj Scale = 1:22.2 1 2 7 8 34x8 JUS24 JUS24 4-10-8 4-10-8 4-10-8 4-10-8 0-7-53-10-53-5-23-10-58.00 12 Plate Offsets (X,Y)-- [1:0-3-8,Edge] LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.72 0.98 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.12 -0.24 0.04 0.09 (loc) 3-6 3-6 1 3-6 l/defl >488 >245 n/a >634 L/d 360 240 n/a 240 PLATES MT20 Weight: 13 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-10-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 3-9-0 oc bracing. REACTIONS. (size)2=Mechanical, 3=Mechanical, 1=0-3-8 Max Horz 1=97(LC 12) Max Uplift 2=-74(LC 12), 3=-17(LC 12), 1=-25(LC 12) Max Grav 2=185(LC 1), 3=308(LC 1), 1=593(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3, 1. 7) Use MiTek JUS24 (With 4-10d nails into Girder & 2-10d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 1-0-12 from the left end to 3-0-12 to connect truss(es) to front face of bottom chord. 8) Fill all nail holes where hanger is in contact with lumber. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 3-4=-20 Concentrated Loads (lb) Vert: 7=-351(F) 8=-351(F) June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss MG04 Truss Type Jack-Open Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466182 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:37 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-XVCmEl9VNiLUFnnxh3cq7?aDYjQbNP3o9uXLuaz8bPi Scale = 1:14.4 1 2 3 6 4 5 4x4 4x6 1.5x4 Special Special 2-6-8 2-6-8 4-0-8 1-6-0 -0-11-0 0-11-0 2-6-8 2-6-8 4-0-8 1-6-0 0-7-52-3-102-0-22-3-108.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.21 0.66 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.05 -0.08 0.06 0.03 (loc) 6-9 6-9 4 6-9 l/defl >976 >590 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-0-8 oc purlins, except 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)4=Mechanical, 2=0-3-8, 5=Mechanical Max Horz 2=68(LC 12) Max Uplift 4=-16(LC 8), 2=-31(LC 12), 5=-30(LC 12) Max Grav 4=43(LC 1), 2=294(LC 1), 5=245(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-286/90 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Provide adequate drainage to prevent water ponding. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2, 5. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 190 lb down and 160 lb up at 2-6-8 on top chord, and 62 lb down at 2-6-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 5-7=-20 Continued on page 2 June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss MG04 Truss Type Jack-Open Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466182 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:38 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-0hm9S5A780TLtxM7Em73fD7OI7mq6sIxOYGuQ0z8bPh LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=-147(B) 6=-62(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss MG05 Truss Type Roof Special Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466183 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:39 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-UuKXfRAlvJbCV5xJoUfICQfZ3WEgrJZ5cC0SySz8bPg Scale = 1:16.2 1 2 3 4 7 6 5 8 9 10 3x4 2x4 3x4 4x4 4x8 3x4 Special NAILED Special NAILED 3-6-0 3-6-0 6-0-0 2-6-0 -0-11-0 0-11-0 3-6-0 3-6-0 6-0-0 2-6-0 0-3-110-7-41-5-112-0-151-0-30-5-82-0-151-7-74.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2021/TPI2014 CSI. TC BC WB Matrix-MP 0.21 0.17 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.04 0.03 0.02 (loc) 6 6 9 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 28 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins: 3-4. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)2=0-1-12, 9=0-1-8 Max Horz 2=39(LC 11) Max Uplift 2=-67(LC 10), 9=-31(LC 10) Max Grav 2=434(LC 36), 9=264(LC 35) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 4-9=-296/101 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) -0-11-0 to 2-1-0, Exterior(2R) 2-1-0 to 3-6-0, Exterior(2E) 3-6-0 to 5-6-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Provide adequate drainage to prevent water ponding. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 2, 9. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9. 12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2. 13) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 14) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 15) "NAILED" indicates 3-10d Nails (0.148" x 3") toe-nails per NDS guidelines. 16) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 88 lb down and 130 lb up at 3-6-0 on top chord, and 28 lb down at 3-6-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 17) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Continued on page 2 June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss MG05 Truss Type Roof Special Girder Qty 1 Ply 1 TG140 Job Reference (optional) I46466183 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:39 2021 Page 2 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-UuKXfRAlvJbCV5xJoUfICQfZ3WEgrJZ5cC0SySz8bPg LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-3=-60, 3-4=-60, 5-7=-20 Concentrated Loads (lb) Vert: 4=-35(B) 6=-7(B) 5=-8(B) 3=-37(B) 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss V01 Truss Type Valley Qty 1 Ply 1 TG140 Job Reference (optional) I46466184 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:39 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-UuKXfRAlvJbCV5xJoUfICQfckWG0rJA5cC0SySz8bPg Scale = 1:10.2 1 2 3 2x4 1.5x4 1.5x4 2-2-8 2-2-8 0-0-41-5-118.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.04 0.02 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 2-2-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=2-2-2, 3=2-2-2 Max Horz 1=31(LC 9) Max Uplift 1=-2(LC 12), 3=-13(LC 12) Max Grav 1=63(LC 1), 3=67(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss V02 Truss Type Valley Qty 1 Ply 1 TG140 Job Reference (optional) I46466185 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:40 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-y4uvtnBOfdj36EWWMBAXleCn3wc8amQErsl?Uvz8bPf Scale = 1:9.3 1 2 3 1.5x4 1.5x4 2x4 2-7-0 2-7-0 1-3-80-0-46.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.06 0.03 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 2 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 2-7-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=2-6-8, 2=2-6-8 Max Horz 3=-28(LC 10) Max Uplift 3=-12(LC 15), 2=-5(LC 15) Max Grav 3=91(LC 21), 2=91(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss V03 Truss Type Valley Qty 1 Ply 1 TG140 Job Reference (optional) I46466186 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:41 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-QGSH47C0QxrvkO5iwuhmHrlvTKwrJDgN4WVY1Lz8bPe Scale = 1:16.9 1 2 3 2x4 1.5x4 1.5x4 4-2-8 4-2-8 0-0-42-9-118.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.21 0.13 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 12 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 4-2-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)1=4-2-2, 3=4-2-2 Max Horz 1=70(LC 9) Max Uplift 1=-5(LC 12), 3=-30(LC 12) Max Grav 1=143(LC 1), 3=151(LC 19) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss V04 Truss Type Valley Qty 1 Ply 1 TG140 Job Reference (optional) I46466187 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:41 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-QGSH47C0QxrvkO5iwuhmHrlqeKucJDgN4WVY1Lz8bPe Scale = 1:17.1 1 2 3 1.5x4 1.5x4 2x4 5-3-0 5-3-0 2-7-80-0-46.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.52 0.21 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 2 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 5-3-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)3=5-2-8, 2=5-2-8 Max Horz 3=-69(LC 10) Max Uplift 3=-31(LC 15), 2=-13(LC 15) Max Grav 3=250(LC 21), 2=250(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. June 8,2021 16023 Swingley Ridge RdChesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job 25013-25013A Truss V05 Truss Type Valley Qty 1 Ply 1 TG140 Job Reference (optional) I46466188 8.510 s Jun 1 2021 MiTek Industries, Inc. Mon Jun 7 18:17:42 2021 Page 1 84 Components (Franklin), Franklin, IN - 46131, ID:Y6KbEUSnYVwk2YuHWHi4MazA3gj-uT0fHTDeBEzmMYguTcC?q3H3LkGM2g6XIAE6Znz8bPd Scale = 1:24.9 1 2 3 5 4 6 1.5x4 1.5x4 2x4 1.5x4 1.5x4 7-11-0 7-11-0 3-11-80-0-46.00 12 LOADING (psf) TCLL (roof) Snow (Pf) TCDL BCLL BCDL 20.0 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2021/TPI2014 CSI. TC BC WB Matrix-P 0.27 0.11 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Sheathed or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size)5=7-10-8, 3=7-10-8, 4=7-10-8 Max Horz 5=-110(LC 10) Max Uplift 5=-15(LC 10), 4=-78(LC 15) Max Grav 5=174(LC 21), 3=97(LC 23), 4=480(LC 21) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-391/225 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 4. June 8,2021 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.21.The design does not take into account any dynamic or other loads other than those expressly stated.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3- 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths