Loading...
HomeMy WebLinkAboutS004VALID FOR 1 PERMIT ONLY U.N.O.REMARKS DRWNCHKD DATESCALE: COPYRIGHT ENGINEERING EXPRESS®C:\Users\eric\Engineering Express\Production - Documents\Projects\20-25436 Aluminum Louvered Roof\WP\20-25436j Louvered Roof MPS (IBC).dwg07/30/2020 - 9:01am eric -- - - -- - - 7/22/20RWN EPR 05/11/20RWN EPR 2018 IBC UPDATE 08/24/18TSB RWN INIT ISSUE (AS 18-5654) REQUIRED ALLOWABLE DESIGN PRESSURES USED IN COORDINATION WITH THIS DOCUMENT SHALL BE CALCULATED SEPARATELY PER THE STRUCTURAL REQUIREMENTS OF THE 2012, 2015 OR 2018 INTERNATIONAL BUILDING CODES & ASCE 7-16 OR ASCE 7-10 AS APPLICABLE USING ALLOWABLESTRESS DESIGN METHODOLOGY DESIGN NOTES: GENERAL NOTES: SUNDANCE LOUVERED ROOFS, LLC ALUMINUM LOUVERED ROOF MASTER PLAN SHEET 1.THIS DOCUMENT SHALL NOT BE USED OR REPRODUCED WITHOUT THE ORIGINAL SIGNATURE & RAISED SEAL OF FRANK BENNARDO, P.E. ALTERATIONS, ADDITIONS OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. PHOTOCOPIES AND UNSEALED DOCUMENTS ARE NOT TO BE ACCEPTED. 2.THIS STRUCTURE HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE STRUCTURAL PROVISIONS OF THE 2012, 2015, OR 2018 INTERNATIONAL BUILDING CODES. CONTRACTOR SHALL INVESTIGATE AND CONFORM TO ALL LOCAL BUILDING CODE AMENDMENTS WHICH MAY APPLY AND GOVERN. DESIGN CRITERIA OR SPANS BEYOND STATED HEREIN MAY REQUIRE ADDITIONAL SITE SPECIFIC SEALED ENGINEERING. 3.NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. WIND LOAD DURATION FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN. 4.THE ARCHITECT/ENGINEER OF RECORD FOR THE PROJECT SUPERSTRUCTURE WITH WHICH THIS DESIGN IS USED SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 5.THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. 6.THE CONTRACTOR SHALL CAREFULLY CONSIDER POSSIBLE IMPOSING LOADS ON ROOF, INCLUDING BUT NOT LIMITED TO ANY CONCENTRATED LOADS WHICH MAY JUSTIFY GREATER DESIGN CRITERIA. THIS ADDITIONAL ROOF LOAD CRITERIA SHALL BE PROPERLY ANALYZED BY A LICENSED ENGINEER OR REGISTERED ARCHITECT. 7.LOUVER SYSTEM HINGES AND OPERABILITY ARE OUTSIDE THE SCOPE OF THIS CERTIFICATION. 8.LINEAR INTERPOLATION FOR MEMBER SPANS MAY BE USED FOR ALL LOUVER AND BEAM SCHEDULES. 9.ALL FASTENERS TO BE #14 OR GREATER SAE GRADE 5 UNLESS NOTED OTHERWISE. FASTENERS SHALL BE CADMIUM-PLATED OR OTHERWISE CORROSION-RESISTANT MATERIAL AND SHALL COMPLY WITH "SPECIFICATIONS FOR ALUMINUM STRUCTURES" BY THE ALUMINUM ASSOCIATION, INC., & ANY APPLICABLE FEDERAL, STATE, AND/OR LOCAL CODES. 10.FOR ALUMINUM MEMBERS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND 2.5xDIAMETER MIN. SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE. 11.ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE AS NOTED HEREIN. 12.ALL CONCRETE ANCHORS SHALL BE INSTALLED TO NON-CRACKED CONCRETE ONLY. 13.THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 14.ALL ALUMINUM SHALL BE 6063-T6 ALLOY AND TEMPER UNLESS NOTED OTHERWISE. 15.ALL CONCRETE AND EPOXY TO REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 7 DAYS. 16.STEEL REINFORCEMENT: ALL REINFORCEMENT SHALL BE DEFORMED BARS OF INTERMEDIATE GRADE NEW BILLET STEEL CONFORMING TO CURRENT REQUIREMENTS OF ASTM A615, GRADE 60 (U.N.O.), FREE FROM OIL, LOOSE SCALE AND LOOSE RUST; AND BENT, LAPPED, PLACED, SUPPORTED AND FASTENED ACCORDING TO THE "ACI DETAILING MANUAL" AND ACI 318. ALL STEEL SHALL BE SECURELY HELD IN PLACE DURING POURING OF CONCRETE. IF REQUIRED, ADDITIONAL BARS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR TO FURNISH SUPPORT FOR ALL BARS. 17.ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 18.EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 19.ALTERATIONS, ADDITIONS, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE THIS CERTIFICATION. ANY LOUVERED ROOF SYSTEM COMPONENTS/DETAILS NOT LISTED HEREIN SHALL BE PER MANUFACTURER'S RECOMMENDATIONS SEE SHEET 8 FOR OVERHANG OPTIONS SCAN HERE: OR, GO TO ECALC.IO/2025436 ABOUT THIS DOCUMENT ENGINEER-CERTIFIED ORIGINALS, VARIATIONS & MORE INFORMATION CAN BE FOUND BY VISITING ENGINEERINGEXPRESS.COM/STORE OR BY SCANNING OR USING THE WEB ADDRESS FOUND HERE > THIS DOCUMENT NOT VALID WITHOUT ORIGINAL ENGINEER CERTIFICATION NOTE: SINGLE-BAY AND DOUBLE-BAY PLAN VIEWS ARE SHOWN ON THIS PAGE. FOR MULTI-BAY OPTIONS, SEE PAGE 3. BEAM SPAN (SEE SCHEDULES)LOUVER SPAN(SEE SCHEDULES)UNLOADED OUTER BEAM MAIN BEAM MAIN BEAM POST, TYP. LOUVERS, TYP. BEAM SPAN (SEE SCHEDULES)LOUVER SPAN(SEE SCHEDULES)UNLOADED OUTER BEAM LEDGER BEAM MAIN BEAM POST, TYP. LOUVERS, TYP. STRUCTURE, BY OTHERS BEAM SPAN (SEE SCHEDULES)LOUVER SPAN(SEE SCHEDULES)UNLOADED OUTER BEAM MAIN BEAM MAIN BEAM LOUVERS, TYP. BEAM SPAN (SEE SCHEDULES) MAIN BEAM POST, TYP. BEAM SPAN (SEE SCHEDULES)LOUVER SPAN(SEE SCHEDULES)UNLOADED OUTER BEAM MAIN BEAM LOUVERS, TYP. BEAM SPAN (SEE SCHEDULES) MAIN BEAM POST, TYP. LEDGER BEAM HOST STRUCTURE, BY OTHERS N.T.S. FREESTANDING (4 POSTS) PLAN N.T.S. HOST ATTACHED (2 POSTS) N.T.S. FREESTANDING (6 POSTS) N.T.S. HOST ATTACHED (3 POSTS) 22 42 12 42 1 222 3 2 3 2 PLAN PLANPLAN BEAM TO CORNER POST BEAM TO CORNER POST BEAM TO CORNER POST BEAM TO CORNER POST BEAM TO MID POST 05/04/2021 VALID ONLY FOR ZIP CODE: 46033 VALID ONLY FOR: Cutting Edge Hardscapes FOR PERMIT USE WITHIN 14 DAYS OF DIGITAL SEAL PE10606888 ATTENTION: PRINTED COPIES OF THIS FILE NOT TO BE USED TO OBTAIN PERMIT Digitally signed by Frank Bennardo Date: 2021.05.04 15:29:40 -04'00' 06/29/21