HomeMy WebLinkAboutFloor Plans35'-4 1/2"
24"X24"XI2"
CONC. PAD
F
=74
COVERED PORCH
4" CONCRETE SLAB ON
UNEXCAVATED FILL
cry U
�o
00< ENTERTAINMENT
8'-9 1/2" CLG. HGT.
OPTIONAL BULKHEAD CEILING
CINESTARPANEL - SEE BLDR.
ol
(COUNTERTOP
N
co
I
19'-1 1/2" DROPPED BEAM
DESIGN BY OTHERS
ol 4'
0"
o
X
°D cv
XZ
L
00
11 — ,�
cry U
� O -
ao �
2-8
89'-2 1/4"
24"X24"XI2"
CONC. PAD
F
0
WINDOW
— J � WELL
F�
cry U
O
00
BEDROOM
_Q
8'-9 1/2" CLG. HGT
DH3b" Xb0"
o I
I
o_
X b WALL W/ FO TE
0"x 3 c1
F.G. E W/ 1 E WA L W.1.C.
8'-4° I
ol
�,_0„---------
� (V
Q W.I.C.
2 X b WALL W/ FOOTER 2-b
IL— — — —
�o
BEDROOM oPr—
8'-9 1/2" CLG. HGT. r Q�,
UP
4'-4" DROPPED BEAM
_M Ib R 8 1 3/8" DESIGN BY OTHERS
15 T 8 10.0° 24"X24"XI2"
CONC. PADS
_ 2 X b WALL
L
Mm `" W/H /W/S 1
3'-8" "' FURW
X b WALL W/ FO TE
GYM\
8'-9 1/2" CLG. HGT.
~ 4 12"
90
r F-
- Q
0
I
r
b'-3 3/4" 2'-C
FOUNDATION PLAN
SCALE: 1/4=11-011 8'-9 1/2" - TOP OF SLAB TO
BOTTOM OF FLOOR JOIST
POURED WALL HEIGHT - 9'-0"
`-n U
F- O
00
—<
1/2"
I
C4
PORCH °°
4" CONCRETE SLAB ON
UNEXCAVATED FILL
x
M
o I ' WINDOW '
WELL
Is'-Ir L� J
/ F OTE
I \ I
MECHANICAL
8'-9 1/2" CLG. HGT.
L5�
2'-C b'-3 3/4"
2'-0 1/8" 91_31, 2'-0 1/8"
39'-111,
T-L"
2'-0 1/8
0
I
r
89'-2 1/4"
'-0 1/41,
3 CAR GARAGE
4" CONCRETE SLAB W/
4" GRANULAR FILL MIN
I1'-9 1/2"
\ 9:
9 � A* \
eo/ \
0 '34 \ \
/
DROP FND. 8" BELOW SLAB 14' X 8' O.H.D. ABOVE
/
\ \ \yp�FBo ( /%
24'-8 3/8"
1'-9 3/
m
I
O
Z
(2) 2XI2 HDR
(2) 2XI2 HDR.
WINDOW 8 DOOR FRAMING DTL
GENERAL FOUNDATION PLAN NOTES:
I. ALL FOOTINGS SHALL BE BELOW FROST LINE
MINIMUM SIZE SHALL BE AS PER LOCAL
CODE.
2. FOUNDATION WALLS SHALL BE 8" THICK OR
MINIMUM SIZE AS PER LOCAL CODE.
3. ALL FOUNDATION ANCHORS SHALL BE C-0"
ON CENTER AND 2 PER CORNER.
4. GRADE ALL SOIL AWAY FROM DWELLING TO
PROVIDE POSITIVE DRAINAGE. MAINTAIN 4"
SPACE BETWEEN GRADE AND ANY WOOD
TRIM.
5. ALL WORK IS TO BE PERFORMED AND
PROVIDED, TO MEET OR EXCEED LOCAL
BUILDING CODES.
4. VERIFY ALL MASONRY LINTEL SIZES AND
TYPES WITH BUILDER PRIOR TO PERFORMING
WORK.
1. IN UNFINISHED AREAS ALL DIMENSIONS ARE
TO THE FACE OF THE FOUNDATION WALL
8. IN FINISHED AREAS ALL DIMENSIONS ARE TO
THE FACE OF THE FRAMED WALL.
9. FACE OF FRAMED WALLS TO BE 4" OR 4 1/2"
OUT FROM FACE OF FOUNDATION WALL.
SQUARE FOOTAGE TABLE
FOUNDATION
TOTAL SQUARE FOOTAGE
1661
SF
FINISHED SQUARE FOOTAGE
1382
SF
MECH./STORAGE SQUARE FOOTAGE
279
SF
CRAWL SPACE
0
SF
FIRST FLOOR
FINISHED SQUARE FOOTAGE
1710
SF
GARAGE SQUARE FOOTAGE
1112
SF
BACK PORCH SQUARE FOOTAGE
328
SF
FRONT PORCH SQUARE FOOTAGE
249
SF
SECOND FLOOR
FINISHED SQUARE FOOTAGE
820
SF
UNFINISHED SQUARE FOOTAGE
0
SF
TOTAL FINISH SQ. FT.
3912
SF
TOTAL SQUARE FOOTAGE
4191 SF
$$
IT IS THE BUILDER/ OWNERS RESPONSIBILITY TO VERIFY
THE PROPER AIR SPACE BETWEEN ALL BRICK AND WOOD
WALLS WITH HOUSE WRAP, TO PREVENT WATER INFILTRATION.
BUILDER/ OWNER SHOULD SEEK THE ASSISTANCE OF A
QUALIFIED ENGINEER FOR THE PROPER SIZING OF ALL
STRUCTURAL HEADERS, RAFTERS, SUPPORT BEAMS,
LAMINATED BEAMS, JOISTS, FOOTINGS, ETC. IT IS THE
BUILDER/ OWNER RESPONSIBILITY TO VERIFY ALL DIMENSIONS
1 DESIGN OF THESE DOCUMENTS FOR ACCURACY.
Lu
Lu
Q
r-
cU
U
z
w
U
0—
w
C
U
(f
O
W
oz
w
—
�
I I I
/--1�
�
U
Q
O
4
Lu
�
z
Q
}
Z
W
lI--
w
Lu M
Lu
J
U
Z <
< �z
Lu
0—
QL 0 DC
Q
� � U
rZ
V
z
F
�Z
ui
W
0
0
O V
J
'o 3Q
s10
0
W
Z0z
Lus
�
Q
oaf
z—u)
H
J v Q
V
0
W=�
W
w
w
m
J_
z Q
Q
=
�
F
w
Z
VI
SHEET NO
14-2
OF
4
PATE
6/16/21
DUJN NO
10
FIRST FLOOR PLAN
SCALE: 1/4"=1'-0"
WALL HEIGHT - 9'-1 1/8"
(2) 1 3/4" X 14" LVL BEAM HEADER
1000 LB ANCHOR STRAP
TOP PLATE
ANCHOR BOLT e 4'-0"
2x4 BOTTOM PLATE
:,E DOOR FRAMING DETAIL
GENERAL FLOOR PLAN NOTES:
I. ALL INTERIOR WALLS ARE 2X4 OR 2X6 AS
SHOWN. EXTERIOR WALLS ARE 2X4 OR 2X6 W/
ONE LAYER OF 1/2" SHEATHING. ALIGN EXTERIOR
OF SHEATHING WITH FOUNDATION WALL. ALL
ANGLED WALLS ARE 45 DEGREES FROM
ADJACENT WALL UNLESS OTHERWISE NOTED.
2. CONFIRM ALL HEADER HEIGHTS AND SIZES
PRIOR TO START OF FRAMING. ALL OPENINGS
ARE TO BE 4" FROM ADJACENT WALL UNLESS
NOTED OTHERWISE.
3. VERIFY ALL TYPES AND SIZES OF WINDOW UNITS
AND DOORS WITH OWNER/BUILDER. NOTIFY
BUILDER OF ANY DISCREPANCIES.
4. VERIFY LOCATION, TYPES AND SIZES OF VENTS
AND EXTERIOR TRIM WITH OWNER/BUILDER.
S. INSULATE HIDDEN AREAS OR ASSEMBLIES
BEFORE COVERING.
4. BUILDER/LUMBER SUPPLIER SHALL SPECIFY
SIZES OF DIMENSIONAL LUMBER FOR FLOOR AND
ROOF SYSTEMS. NOTIFY BUILDER/LUMBER
SUPPLIER IMMEDIATELY OF ANY DISCREPANCIES.
1. STEEL LINTELS OR WOOD BEARING AREAS,
PROPERLY SIZED, ARE TO BE PROVIDED
OVER ALL OPENINGS TO SUPPORT MASONRY
VENEER.
8. ALL ROOF AND WALL INTERSECTIONS SHALL BE
FLASHED WITH ALUMINUM OR BETTER MATERIAL.
9. ALL BEDROOM EGRESS WINDOWS TO MEET MIN.
CLEAR OPENING OF 5.1 FT2 UNLESS NOTED
OTHERWISE. ONE WINDOW MINIMUM NEEDED PER
BEDROOM.
GARAGE DOOR FRM. DTL.
SCALE: 1/4"=1'-0"
SQUARE FOOTAGE TABLE
FOUNDATION
TOTAL SQUARE FOOTAGE
FINISHED SQUARE FOOTAGE
MECH./STORAGE SQUARE FOOTAGE
CRAWL SPACE
FIRST FLOOR
FINISHED SQUARE FOOTAGE
GARAGE SQUARE FOOTAGE
BACK PORCH SQUARE FOOTAGE
FRONT PORCH SQUARE FOOTAGE
SECOND FLOOR
FINISHED SQUARE FOOTAGE
UNFINISHED SQUARE FOOTAGE
1661 SF
1382 SF
279 SF
0 SF
1710 SF
1112 SF
328 SF
249 SF
820 SF
0 SF
TOTAL FINISH 50. FT. 3912 SF
TOTAL SQUARE FOOTAGE 4191 SF
IS THE BUILDER/ OWNERS RESPONSIBILITY TO VERIFY
THE PROPER AIR SPACE BETWEEN ALL BRICK AND WOOD
WALLS WITH HOUSE WRAP, TO PREVENT WATER INFILTRATION.
BUILDER/ OWNER SHOULD SEEK THE ASSISTANCE OF A
QUALIFIED ENGINEER FOR THE PROPER SIZING OF ALL
STRUCTURAL HEADERS, RAFTERS, SUPPORT BEAMS,
LAMINATED BEAMS, JOISTS, FOOTINGS, ETC. IT IS THE
BUILDER/ OWNER RESPONSIBILITY TO VERIFY ALL DIMENSIONS
i DESIGN OF THESE DOCUMENTS FOR ACCURACY.
or
�
mLu
1J0�
Lu
z
w
U
-j
:z
CL
w
C)
oz
Uco
O
w
w
w
O
Lu
LL-
u
oz
LL-
O
a
W
�7—
�q
U
z
Q
O
z
�
w
lI--
Lu
Lu M
�z0
z_
F-
�0-=
[Y O oi�
4
� � U
rz
V
Z
0
F
VJ
LLJ
W
0
0
O V
' J
� 3 Q
F
J 10
0
W
w
z"(D
Qsz
oao
zr U)
--w
z
LLI
H
J v Q
V
0
W=�
w
m
0 J_
w
=
z Q
F
Q
�
w
T—
SHEET NO
A - 3
OF 4
PATE
4/14/21
pUJN NO
10
-----------------------------------------
COVERED PORCH BELOW
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —�— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
FIRST FLOOR WALL BELOW GARAGE WALL BELOW
30"X30"
ACCESS
I orl nill
/
/
GARAGE WALL BELOW /
— — — — — — — — — — — — — — — — — — — — — — — --
�
/
��o
SECOND FLOOR PLAN
SCALE: 1/4"=1'-0"
WALL HEIGHT - 9'-I I/8"
GENERAL FLOOR PLAN NOTES:
I. ALL INTERIOR WALLS ARE 2X4 OR 2X6 AS
SHOWN. EXTERIOR WALLS ARE 2X4 OR 2X6 W/
ONE LAYER OF 1/2" SHEATHING. ALIGN EXTERIOR
OF SHEATHING WITH FOUNDATION WALL. ALL
ANGLED WALLS ARE 45 DEGREES FROM
ADJACENT WALL UNLESS OTHERWISE NOTED.
2. CONFIRM ALL HEADER HEIGHTS AND SIZES
PRIOR TO START OF FRAMING. ALL OPENINGS
ARE TO BE 4" FROM ADJACENT WALL UNLESS
NOTED OTHERWISE.
3. VERIFY ALL TYPES AND SIZES OF WINDOW UNITS
AND DOORS WITH OWNER/BUILDER. NOTIFY
BUILDER OF ANY DISCREPANCIES.
4. VERIFY LOCATION, TYPES AND SIZES OF VENTS
AND EXTERIOR TRIM WITH OWNER/BUILDER.
S. INSULATE HIDDEN AREAS OR ASSEMBLIES
BEFORE COVERING.
4. BUILDER/LUMBER SUPPLIER SHALL SPECIFY
SIZES OF DIMENSIONAL LUMBER FOR FLOOR AND
ROOF SYSTEMS. NOTIFY BUILDER/LUMBER
SUPPLIER IMMEDIATELY OF ANY DISCREPANCIES.
1. STEEL LINTELS OR WOOD BEARING AREAS,
PROPERLY SIZED, ARE TO BE PROVIDED
OVER ALL OPENINGS TO SUPPORT MASONRY
VENEER.
8. ALL ROOF AND WALL INTERSECTIONS SHALL BE
FLASHED WITH ALUMINUM OR BETTER MATERIAL.
9. ALL BEDROOM EGRESS WINDOWS TO MEET MIN.
CLEAR OPENING OF 5.1 FT2 UNLESS NOTED
OTHERWISE. ONE WINDOW MINIMUM NEEDED PER
BEDROOM.
SQUARE FOOTAGE TABLE
FOUNDATION
TOTAL SQUARE FOOTAGE
FINISHED SQUARE FOOTAGE
rIECH./STORAGE SQUARE FOOTAGE
CRAWL SPACE
FIRST FLOOR
FINISHED SQUARE FOOTAGE
GARAGE SQUARE FOOTAGE
BACK PORCH SQUARE FOOTAGE
FRONT PORCH SQUARE FOOTAGE
SECOND FLOOR
FINISHED SQUARE FOOTAGE
UNFINISHED SQUARE FOOTAGE
1661 SF
1382 SF
279 SF
0 SF
1710 SF
1112 SF
328 SF
249 SF
820 SF
0 SF
TOTAL FINISH 50. FT. 3912 SF
TOTAL SQUARE FOOTAGE 4191 SF
#NOTE0 '
IT IS THE BUILDER/ OWNERS RESPONSIBILITY TO VERIFY
THE PROPER AIR SPACE BETWEEN ALL BRICK AND WOOD
WALLS WITH HOUSE WRAP, TO PREVENT WATER INFILTRATION.
BUILDER/ OWNER SHOULD SEEK THE ASSISTANCE OF A
QUALIFIED ENGINEER FOR THE PROPER SIZING OF ALL
STRUCTURAL HEADERS, RAFTERS, SUPPORT BEAMS,
LAMINATED BEAMS, JOISTS, FOOTINGS, ETC. IT IS THE
BUILDER/ OWNER RESPONSIBILITY TO VERIFY ALL DIMENSIONS
i DESIGN OF THESE DOCUMENTS FOR ACCURACY.
or
�
mLu
1J0�
Lu
cU
w
U
w
Q
wLLJ
oz
w
U
w
w
w
N
z
IL
QL
O
O
0
z
U
w
co
O
W li yf
�7-
U
O
z
�
w
lI--
Lu
M
�z0
Lu
J
Z <
z_
o��
[Y O 4
� �
U
rZ
V
Z
0
F
VJ
LLJ
W
0
0
O V
' J
� 3 Q
F
J 10
0
W
w
z"(D
Qsz
oao
zr U)
--w
z
LLI
H
LL
J v Q
V
0
W=�
w
m
0 J_
w
=
z Q
F
Q
�
w
v!
SHEET NO
A-04
OF 4
PATE
4/14/21
pUJN NO
10