Loading...
HomeMy WebLinkAboutFloor Plans35'-4 1/2" 24"X24"XI2" CONC. PAD F =74 COVERED PORCH 4" CONCRETE SLAB ON UNEXCAVATED FILL cry U �o 00< ENTERTAINMENT 8'-9 1/2" CLG. HGT. OPTIONAL BULKHEAD CEILING CINESTARPANEL - SEE BLDR. ol (COUNTERTOP N co I 19'-1 1/2" DROPPED BEAM DESIGN BY OTHERS ol 4' 0" o X °D cv XZ L 00 11 — ,� cry U � O - ao � 2-8 89'-2 1/4" 24"X24"XI2" CONC. PAD F 0 WINDOW — J � WELL F� cry U O 00 BEDROOM _Q 8'-9 1/2" CLG. HGT DH3b" Xb0" o I I o_ X b WALL W/ FO TE 0"x 3 c1 F.G. E W/ 1 E WA L W.1.C. 8'-4° I ol �,_0„--------- � (V Q W.I.C. 2 X b WALL W/ FOOTER 2-b IL— — — — �o BEDROOM oPr— 8'-9 1/2" CLG. HGT. r Q�, UP 4'-4" DROPPED BEAM _M Ib R 8 1 3/8" DESIGN BY OTHERS 15 T 8 10.0° 24"X24"XI2" CONC. PADS _ 2 X b WALL L Mm `" W/H /W/S 1 3'-8" "' FURW X b WALL W/ FO TE GYM\ 8'-9 1/2" CLG. HGT. ~ 4 12" 90 r F- - Q 0 I r b'-3 3/4" 2'-C FOUNDATION PLAN SCALE: 1/4=11-011 8'-9 1/2" - TOP OF SLAB TO BOTTOM OF FLOOR JOIST POURED WALL HEIGHT - 9'-0" `-n U F- O 00 —< 1/2" I C4 PORCH °° 4" CONCRETE SLAB ON UNEXCAVATED FILL x M o I ' WINDOW ' WELL Is'-Ir L� J / F OTE I \ I MECHANICAL 8'-9 1/2" CLG. HGT. L5� 2'-C b'-3 3/4" 2'-0 1/8" 91_31, 2'-0 1/8" 39'-111, T-L" 2'-0 1/8 0 I r 89'-2 1/4" '-0 1/41, 3 CAR GARAGE 4" CONCRETE SLAB W/ 4" GRANULAR FILL MIN I1'-9 1/2" \ 9: 9 � A* \ eo/ \ 0 '34 \ \ / DROP FND. 8" BELOW SLAB 14' X 8' O.H.D. ABOVE / \ \ \yp�FBo ( /% 24'-8 3/8" 1'-9 3/ m I O Z (2) 2XI2 HDR (2) 2XI2 HDR. WINDOW 8 DOOR FRAMING DTL GENERAL FOUNDATION PLAN NOTES: I. ALL FOOTINGS SHALL BE BELOW FROST LINE MINIMUM SIZE SHALL BE AS PER LOCAL CODE. 2. FOUNDATION WALLS SHALL BE 8" THICK OR MINIMUM SIZE AS PER LOCAL CODE. 3. ALL FOUNDATION ANCHORS SHALL BE C-0" ON CENTER AND 2 PER CORNER. 4. GRADE ALL SOIL AWAY FROM DWELLING TO PROVIDE POSITIVE DRAINAGE. MAINTAIN 4" SPACE BETWEEN GRADE AND ANY WOOD TRIM. 5. ALL WORK IS TO BE PERFORMED AND PROVIDED, TO MEET OR EXCEED LOCAL BUILDING CODES. 4. VERIFY ALL MASONRY LINTEL SIZES AND TYPES WITH BUILDER PRIOR TO PERFORMING WORK. 1. IN UNFINISHED AREAS ALL DIMENSIONS ARE TO THE FACE OF THE FOUNDATION WALL 8. IN FINISHED AREAS ALL DIMENSIONS ARE TO THE FACE OF THE FRAMED WALL. 9. FACE OF FRAMED WALLS TO BE 4" OR 4 1/2" OUT FROM FACE OF FOUNDATION WALL. SQUARE FOOTAGE TABLE FOUNDATION TOTAL SQUARE FOOTAGE 1661 SF FINISHED SQUARE FOOTAGE 1382 SF MECH./STORAGE SQUARE FOOTAGE 279 SF CRAWL SPACE 0 SF FIRST FLOOR FINISHED SQUARE FOOTAGE 1710 SF GARAGE SQUARE FOOTAGE 1112 SF BACK PORCH SQUARE FOOTAGE 328 SF FRONT PORCH SQUARE FOOTAGE 249 SF SECOND FLOOR FINISHED SQUARE FOOTAGE 820 SF UNFINISHED SQUARE FOOTAGE 0 SF TOTAL FINISH SQ. FT. 3912 SF TOTAL SQUARE FOOTAGE 4191 SF $$ IT IS THE BUILDER/ OWNERS RESPONSIBILITY TO VERIFY THE PROPER AIR SPACE BETWEEN ALL BRICK AND WOOD WALLS WITH HOUSE WRAP, TO PREVENT WATER INFILTRATION. BUILDER/ OWNER SHOULD SEEK THE ASSISTANCE OF A QUALIFIED ENGINEER FOR THE PROPER SIZING OF ALL STRUCTURAL HEADERS, RAFTERS, SUPPORT BEAMS, LAMINATED BEAMS, JOISTS, FOOTINGS, ETC. IT IS THE BUILDER/ OWNER RESPONSIBILITY TO VERIFY ALL DIMENSIONS 1 DESIGN OF THESE DOCUMENTS FOR ACCURACY. Lu Lu Q r- cU U z w U 0— w C U (f O W oz w — � I I I /--1� � U Q O 4 Lu � z Q } Z W lI-- w Lu M Lu J U Z < < �z Lu 0— QL 0 DC Q � � U rZ V z F �Z ui W 0 0 O V J 'o 3Q s10 0 W Z0z Lus � Q oaf z—u) H J v Q V 0 W=� W w w m J_ z Q Q = � F w Z VI SHEET NO 14-2 OF 4 PATE 6/16/21 DUJN NO 10 FIRST FLOOR PLAN SCALE: 1/4"=1'-0" WALL HEIGHT - 9'-1 1/8" (2) 1 3/4" X 14" LVL BEAM HEADER 1000 LB ANCHOR STRAP TOP PLATE ANCHOR BOLT e 4'-0" 2x4 BOTTOM PLATE :,E DOOR FRAMING DETAIL GENERAL FLOOR PLAN NOTES: I. ALL INTERIOR WALLS ARE 2X4 OR 2X6 AS SHOWN. EXTERIOR WALLS ARE 2X4 OR 2X6 W/ ONE LAYER OF 1/2" SHEATHING. ALIGN EXTERIOR OF SHEATHING WITH FOUNDATION WALL. ALL ANGLED WALLS ARE 45 DEGREES FROM ADJACENT WALL UNLESS OTHERWISE NOTED. 2. CONFIRM ALL HEADER HEIGHTS AND SIZES PRIOR TO START OF FRAMING. ALL OPENINGS ARE TO BE 4" FROM ADJACENT WALL UNLESS NOTED OTHERWISE. 3. VERIFY ALL TYPES AND SIZES OF WINDOW UNITS AND DOORS WITH OWNER/BUILDER. NOTIFY BUILDER OF ANY DISCREPANCIES. 4. VERIFY LOCATION, TYPES AND SIZES OF VENTS AND EXTERIOR TRIM WITH OWNER/BUILDER. S. INSULATE HIDDEN AREAS OR ASSEMBLIES BEFORE COVERING. 4. BUILDER/LUMBER SUPPLIER SHALL SPECIFY SIZES OF DIMENSIONAL LUMBER FOR FLOOR AND ROOF SYSTEMS. NOTIFY BUILDER/LUMBER SUPPLIER IMMEDIATELY OF ANY DISCREPANCIES. 1. STEEL LINTELS OR WOOD BEARING AREAS, PROPERLY SIZED, ARE TO BE PROVIDED OVER ALL OPENINGS TO SUPPORT MASONRY VENEER. 8. ALL ROOF AND WALL INTERSECTIONS SHALL BE FLASHED WITH ALUMINUM OR BETTER MATERIAL. 9. ALL BEDROOM EGRESS WINDOWS TO MEET MIN. CLEAR OPENING OF 5.1 FT2 UNLESS NOTED OTHERWISE. ONE WINDOW MINIMUM NEEDED PER BEDROOM. GARAGE DOOR FRM. DTL. SCALE: 1/4"=1'-0" SQUARE FOOTAGE TABLE FOUNDATION TOTAL SQUARE FOOTAGE FINISHED SQUARE FOOTAGE MECH./STORAGE SQUARE FOOTAGE CRAWL SPACE FIRST FLOOR FINISHED SQUARE FOOTAGE GARAGE SQUARE FOOTAGE BACK PORCH SQUARE FOOTAGE FRONT PORCH SQUARE FOOTAGE SECOND FLOOR FINISHED SQUARE FOOTAGE UNFINISHED SQUARE FOOTAGE 1661 SF 1382 SF 279 SF 0 SF 1710 SF 1112 SF 328 SF 249 SF 820 SF 0 SF TOTAL FINISH 50. FT. 3912 SF TOTAL SQUARE FOOTAGE 4191 SF IS THE BUILDER/ OWNERS RESPONSIBILITY TO VERIFY THE PROPER AIR SPACE BETWEEN ALL BRICK AND WOOD WALLS WITH HOUSE WRAP, TO PREVENT WATER INFILTRATION. BUILDER/ OWNER SHOULD SEEK THE ASSISTANCE OF A QUALIFIED ENGINEER FOR THE PROPER SIZING OF ALL STRUCTURAL HEADERS, RAFTERS, SUPPORT BEAMS, LAMINATED BEAMS, JOISTS, FOOTINGS, ETC. IT IS THE BUILDER/ OWNER RESPONSIBILITY TO VERIFY ALL DIMENSIONS i DESIGN OF THESE DOCUMENTS FOR ACCURACY. or � mLu 1J0� Lu z w U -j :z CL w C) oz Uco O w w w O Lu LL- u oz LL- O a W �7— �q U z Q O z � w lI-- Lu Lu M �z0 z_ F- �0-= [Y O oi� 4 � � U rz V Z 0 F VJ LLJ W 0 0 O V ' J � 3 Q F J 10 0 W w z"(D Qsz oao zr U) --w z LLI H J v Q V 0 W=� w m 0 J_ w = z Q F Q � w T— SHEET NO A - 3 OF 4 PATE 4/14/21 pUJN NO 10 ----------------------------------------- COVERED PORCH BELOW I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —�— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — FIRST FLOOR WALL BELOW GARAGE WALL BELOW 30"X30" ACCESS I orl nill / / GARAGE WALL BELOW / — — — — — — — — — — — — — — — — — — — — — — — -- � / ��o SECOND FLOOR PLAN SCALE: 1/4"=1'-0" WALL HEIGHT - 9'-I I/8" GENERAL FLOOR PLAN NOTES: I. ALL INTERIOR WALLS ARE 2X4 OR 2X6 AS SHOWN. EXTERIOR WALLS ARE 2X4 OR 2X6 W/ ONE LAYER OF 1/2" SHEATHING. ALIGN EXTERIOR OF SHEATHING WITH FOUNDATION WALL. ALL ANGLED WALLS ARE 45 DEGREES FROM ADJACENT WALL UNLESS OTHERWISE NOTED. 2. CONFIRM ALL HEADER HEIGHTS AND SIZES PRIOR TO START OF FRAMING. ALL OPENINGS ARE TO BE 4" FROM ADJACENT WALL UNLESS NOTED OTHERWISE. 3. VERIFY ALL TYPES AND SIZES OF WINDOW UNITS AND DOORS WITH OWNER/BUILDER. NOTIFY BUILDER OF ANY DISCREPANCIES. 4. VERIFY LOCATION, TYPES AND SIZES OF VENTS AND EXTERIOR TRIM WITH OWNER/BUILDER. S. INSULATE HIDDEN AREAS OR ASSEMBLIES BEFORE COVERING. 4. BUILDER/LUMBER SUPPLIER SHALL SPECIFY SIZES OF DIMENSIONAL LUMBER FOR FLOOR AND ROOF SYSTEMS. NOTIFY BUILDER/LUMBER SUPPLIER IMMEDIATELY OF ANY DISCREPANCIES. 1. STEEL LINTELS OR WOOD BEARING AREAS, PROPERLY SIZED, ARE TO BE PROVIDED OVER ALL OPENINGS TO SUPPORT MASONRY VENEER. 8. ALL ROOF AND WALL INTERSECTIONS SHALL BE FLASHED WITH ALUMINUM OR BETTER MATERIAL. 9. ALL BEDROOM EGRESS WINDOWS TO MEET MIN. CLEAR OPENING OF 5.1 FT2 UNLESS NOTED OTHERWISE. ONE WINDOW MINIMUM NEEDED PER BEDROOM. SQUARE FOOTAGE TABLE FOUNDATION TOTAL SQUARE FOOTAGE FINISHED SQUARE FOOTAGE rIECH./STORAGE SQUARE FOOTAGE CRAWL SPACE FIRST FLOOR FINISHED SQUARE FOOTAGE GARAGE SQUARE FOOTAGE BACK PORCH SQUARE FOOTAGE FRONT PORCH SQUARE FOOTAGE SECOND FLOOR FINISHED SQUARE FOOTAGE UNFINISHED SQUARE FOOTAGE 1661 SF 1382 SF 279 SF 0 SF 1710 SF 1112 SF 328 SF 249 SF 820 SF 0 SF TOTAL FINISH 50. FT. 3912 SF TOTAL SQUARE FOOTAGE 4191 SF #NOTE0 ' IT IS THE BUILDER/ OWNERS RESPONSIBILITY TO VERIFY THE PROPER AIR SPACE BETWEEN ALL BRICK AND WOOD WALLS WITH HOUSE WRAP, TO PREVENT WATER INFILTRATION. BUILDER/ OWNER SHOULD SEEK THE ASSISTANCE OF A QUALIFIED ENGINEER FOR THE PROPER SIZING OF ALL STRUCTURAL HEADERS, RAFTERS, SUPPORT BEAMS, LAMINATED BEAMS, JOISTS, FOOTINGS, ETC. IT IS THE BUILDER/ OWNER RESPONSIBILITY TO VERIFY ALL DIMENSIONS i DESIGN OF THESE DOCUMENTS FOR ACCURACY. or � mLu 1J0� Lu cU w U w Q wLLJ oz w U w w w N z IL QL O O 0 z U w co O W li yf �7- U O z � w lI-- Lu M �z0 Lu J Z < z_ o�� [Y O 4 � � U rZ V Z 0 F VJ LLJ W 0 0 O V ' J � 3 Q F J 10 0 W w z"(D Qsz oao zr U) --w z LLI H LL J v Q V 0 W=� w m 0 J_ w = z Q F Q � w v! SHEET NO A-04 OF 4 PATE 4/14/21 pUJN NO 10