LINETYPE DESIGNATORS
THIN CONTINUOUS LINETYPE INDICATE EXISTING ITEMS.
INTERMEDIATE DASHED LINETYPE INDICATE ITEMS TO BE
REMOVED ON COMBINATION PLANS.
INTERMEDIATE OR WIDE CONTINUOUS LINETYPE INDICATE
WORK TO BE INCLUDED.
THIN HALFTONE LINETYPE INDICATE ITEMS BY OTHER DISCIPLINE.
INDICATES POINT OF CONNECTION TO EXISTING
EQUIPMENT, PIPING OR MATERIALS.
INDICATES POINT OF DISCONNECTION TO EXISTING
EQUIPMENT, PIPING OR MATERIALS.
SHEET TYPE DESIGNATORS
000 GENERAL (SYMBOLS, ABBREVIATIONS, NOTES)
100 PLANS
200 PLANS (SECONDARY)
300 ENLARGED PLANS & SECTIONS
400 SCHEMATICS & DIAGRAMS
500 SCHEDULES
600 DETAILS
700 CONTROL DIAGRAMS
800 (USER DEFINED)
900 3D REPRESENTATIONS (ISOMETRICS)
NOTATION DESIGNATORS
GENERAL MECHANICAL
NOTES:
NOTES THAT APPLY EQUALLY TO ALL SHEETS WITHIN THE
DISCIPLINE.
GENERAL SHEET
NOTES:
NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON
WHICH THEY APPEAR.
SHEET PLAN NOTES: NOTES THAT APPLY ONLY TO THE SPECIFIC SHEET ON
WHICH THEY APPEAR AND USE A PLAN NOTE INDICATOR
TO IDENTIFY ITEMS.
DISCIPLINE DESIGNATORS
M-000 MECHANICAL
FP000 FIRE SUPPRESSION
P-000 PLUMBING
PD000 PLUMBING DEMOLITION
H-000 HVAC
HD000 HVAC DEMOLITION
HP000 HVAC PIPING
SHEET PLAN NOTES
1. NOT ALL NOTES, DESIGNATORS, SYMBOLS OR ABBREVIATIONS MAY APPLY TO THIS PROJECTELECTRICAL SYMBOL SCHEDULE
CEIL WALL FL.
MOUNTING
DESCRIPTION
UPPERCASE LETTER IN QUOTES - TYPELOWER CASE LETTER - SWITCHLEG
RECESSED DOWNLIGHT
H.I.D. FIXTURE
RECESSED FIXTURE -DIRECTIONAL
LIGHT FIXTURE ON EMERGENCY CIRCUIT
SURFACE OR PENDANT MOUNTED FIXTURE
EXIT LIGHT, LINE INDICATES FACE
ARROW INDICATES FACE WITH ARROW
BATTERY PACK LIGHTS
TRACK LIGHT
SINGLE RECEPTACLE
SINGLE RECEPTACLE (+44" AFF)
DUPLEX CONVENIENCE OUTLET
DUPLEX CON. OUTLET -GFI PROTECTED
DUPLEX CON. OUTLET (TOP HALF SWITCHED)
RECEPTACLE (+44" AFF)
QUADRUPLEX OUTLET
QUADRUPLEX OUTLET (+44" AFF)
SAFETY TYPE CONVENIENCE OUTLET
DUPLEX CONVENIENCE OUTLET (EMERGENCY)
WEATHERPROOF CONVENIENCE OUTLET (GFI)
WEATHERPROOF CONVENIENCE OUTLET (GFI) (+44" AFF)
EXPLOSION PROOF CONVENIENCE OUTLET
SPECIAL OUTLET (AS NOTED)
ABOVE COUNTER VOICE/DATA OUTLET (+44" AFF)
VOICE/DATA OUTLET
PUBLIC TELEPHONE OUTLET (VOICE ONLY) +48"
DATA OUTLET (DATA ONLY)
CLOCK OUTLET
SOUND SYSTEM AMPLIFIER
CAMERA
VOLUME CONTROL
SPEAKER
SPEAKER (HORN TYPE)
T.V. CABLE ANTENNA
INTERCOM STATION
INTERCOM MASTER STATION
MICROPHONE OUTLET
EMERGENCY PANIC BUTTON
208/240V OUTLET (SIZE AS NOTED)
S
EE
WP
WP
C
P
CC
AMP
C C
SS
SS
T T
E
CEIL WALL FL.
MOUNTING
DESCRIPTION
PUSHBUTTON STATION AS NOTED
CIRCUIT BREAKER IN ENCLOSURE
DISCONNECT SWITCH (NON-FUSED)
DISCONNECT SWITCH (FUSED)
SWITCH -SINGLE POLE
SWITCH -2 POLE
SWITCH -3 WAY
SWITCH -4 WAY
SWITCH WITH PILOT LIGHT (ANY TYPE SW.)
SWITCH -WEATHERPROOF
MOMENTARY CONTACT SWITCH
MECHANICAL TIMER SWITCH
KEYED SWITCH
HORSEPOWER RATED MANUAL MOTOR STARTER
TOGGLE SWITCH W/ THERMAL OVERLOAD PROTECTION
DIMMER SWITCH. RATED 1000W, UNLESS OTHERWISE
INDICATED. "LV" = LOW VOLTAGE "FL" = FLUORESCENT
DOOR BELL
OCCUPANCY SENSOR
LOW VOLTAGE PUSH BUTTON WALL STATION
PHOTOCELL
MOTORIZED DOOR PUSH PLATE
MAGNETIC LOCK (ROUGH-IN)
ELECTRIC DOOR STRIKE
EXIT ALERT, AUDIBLE, WITH LOCAL KEYSWITCH CONTROL
BASKET TYPE CABLE TRAY OVERHEAD
GROUND WIRE TO GROUND WIRE EXOTHERMIC WELD
GROUND BUS BAR
GROUND ROD
TEST WELL WITH GROUND ROD
MOTOR -SINGLE PHASE
MOTOR -3 PHASE
PLUGMOLD RACEWAY
WIREMOLD RACEWAY
CONDUIT CONCEALED IN OR ABOVE CEILING
CONDUIT EXPOSED
CONDUIT CONCEALED IN OR BELOW FLOOR
HOMERUN
CONDUIT TURNED UP
CONDUIT TURNED DOWN
DIRECT BURIED CABLE
TWISTED PAIR CABLE
CONDUIT STUBBED OUT & CAPPED
CONDUIT STUBBED OUT WITH BUSHING
JUNCTION BOXES
GROUND ROD & CONNECTION
THERMOSTAT
TRANSFORMER
TIME CLOCK
48V D.C. EMERGENCY LIGHT
CIRCUIT BREAKER
COIL (RELAY, CONTACTOR OR CONTROLLER)
FUSE
NORMALLY OPEN CONTACTS
NORMALLY CLOSED CONTACTS
NORMALLY OPEN MOMENTARY CONTACT
NORMALLY CLOSED MOMENTARY CONTACT
PILOT LIGHT
SWITCH (MANUAL OR AS NOTED)
TRANSFORMER
CB
F
S
S
S
S
S
S
S
S
S
S
D
B
WS
PP
H
ML
ES
L
WM
JJ J
T
TC
C
P
1. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BIDDING AND BEGINNING WORK.
2. REVIEW THE WORK OF OTHER TRADES. COORDINATE AND PLAN WORK WITH THE OTHER TRADES. ADJUST AS A RESULT OF COORDINATION.
REVIEW COORDINATED EFFORTS WITH ENGINEER FOR APPROVAL.
3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF ALL CEILING MOUNTED ITEMS.
4. STORE EQUIPMENT AND COMPONENTS IN A CLEAN, DRY LOCATION UNTIL READY FOR INSTALLATION. PROTECT FROM WEATHER, THEFT, DIRT, FUMES,
WATER, CONSTRUCTION DEBRIS, ETC. AT ALL TIMES. ANY DAMAGED EQUIPMENT OR COMPONENT SHALL BE RESTORED AS NEW OR REPLACED.
5. DEMOLITION/REMODEL
A. ALL MATERIALS REMOVED, AND NOT RELOCATED, BECOME THE PROPERTY OF THE CONTRACTOR. REMOVE MATERIALS FROM THE
PROJECT SITE UNLESS NOTED OTHERWISE. OWNER HAS THE OPTION TO REVIEW ITEMS PRIOR TO REMOVAL AND RETAIN IF DESIRED.
B. PATCH WALLS, FLOORS, CEILINGS, COLUMNS, ROOF PENETRATIONS, ETC. WHERE ITEMS ARE REMOVED TO MATCH FINISH OF ADJACENT SURFACES.
C. RELOCATE EXISTING ITEMS AS REQUIRED FOR REMOVAL AND INSTALLATION OF WALLS, CEILINGS, DUCTWORK, PIPING AND EQUIPMENT.
D. REMOVE ALL CONDUIT, WIRING, BOXES, SWITCHES, SUPPORTS, ETC. MADE UNNECESSARY, OR OBSOLETE AS A RESULT OF THIS PROJECT.
E. EQUIP ALL OUTLET BOXES, CONCEALED BY CONSTRUCTION, WITH EXTENSION RINGS, BOXES, OR ACCESS PANEL TO MAINTAIN ACCESS TO BOXES
AND WIRING. NOTE: CONTRACTOR HAS OPTION TO PROVIDE NEW HOME RUNS TO DOWNSTREAM OUTLETS IF EXTENSION BOXES OR ACCESS
PANELS ARE IMPRACTICAL.
F. REARRANGE EXISTING PANEL CIRCUITRY TO ACCOMMODATE REVISIONS.
G. MAINTAIN EXISTING LIGHTING CIRCUITS. RELOCATE LIGHTING, AS SHOWN ON THE DRAWINGS, RECONNECTING TO SWITCHED OR UNSWITCHED
CIRCUITS AS APPLICABLE.
H. ALL ITEMS WITH NOTATION "EX" ARE TO REMAIN.
I. ALL ITEMS WITH NOTATION "R" ARE RELOCATED, AS NOTED.
6. ELECTRICAL DRAWINGS SHOW THE INTENDED ARRANGEMENT AND ROUTING OF ALL CONDUIT AND DEVICES. THEY SHALL BE FOLLOWED AS CLOSELY
AS ACTUAL BUILDING CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT.
7. PERFORM ALL WORK IN A SKILLED, PROFESSIONAL, MANNER MEETING THE ACCEPTANCE OF THE ENGINEER, ARCHITECT AND OWNER.
8. LABEL ALL RECEPTACLE DEVICES AS TO WHICH PANEL AND OVERCURRENT DEVICE FEEDS THE DEVICE WITH AN INDELIBLE MARKER ON THE BACK
SIDE OF THE COVER PLATE. DEVICE WITH PLASTIC ENGRAVED PLATE ON THE FRONT SIDE OF THE COVER PLATE.
9. SMALLEST CONDUIT SIZE ALLOWABLE IS 3/4", AND SMALLEST WIRE SIZE ALLOWABLE IS #12 AWG COPPER UNLESS SPECIFICALLY NOTED OTHERWISE.
ADJUST CIRCUIT AND CONDUIT SIZES FOR VOLTAGE DROP.
10. MOUNTING HEIGHTS OF DEVICES SHALL FOLLOW THE LISTING BELOW UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS.
CONVENIENCE OUTLET ........................................................................... +18" AFF TO CENTERLINE OF DEVICE
TELEPHONE OUTLET ................................................................................ +18" AFF TO CENTERLINE OF DEVICE
DATA OUTLET ............................................................................................ +18" AFF TO CENTERLINE OF DEVICE
LIGHT SWITCH OR DIMMER .................................................................... +48" AFF TO TOP OF DEVICE
DEVICES ABOVE COUNTERTOP ............................................................ +44" AFF TO CENTERLINE OF DEVICE
EXIT LIGHT ................................................................................................. +96" AFF TO CENTERLINE OF DEVICE
THERMOSTAT OR TEMPERATURE/HUMIDITY SENSOR ..................... +46" AFF TO TOP OF DEVICE
FIRE ALARM PULL STATION ................................................................... +48" AFF TO TOP OF DEVICE
FIRE ALARM HORN .................................................................................. +80" AFF TO BOTTOM OF DEVICE
FIRE ALARM STROBE .............................................................................. +80" AFF TO BOTTOM OF DEVICE
FIRE ALARM COMBINATION HORN/STROBE ....................................... +80" AFF TO BOTTOM OF DEVICE
FIRE ALARM REMOTE ALARM LAMP .................................................... +96" AFF TO CENTERLINE OF DEVICE
11. CLEAN ALL EQUIPMENT TO PRESENT A "LIKE NEW" CONDITION AT PROJECT COMPLETION. VACUUM CLEAN INTERNAL AREAS OF EQUIPMENT AND
PANELS.
12. CLEAN ALL MECHANICAL AND ELECTRICAL AREAS AND ROOMS OF DEBRIS AND UNUSED MATERIALS. VACUUM FLOORS.
13. THE MOUNTING POSITION FOR ALL STRAIGHT BLADE, VERTICALLY ORIENTED, NEMA 5, 6, 7, 14 AND 15 RECEPTACLES SHALL BE SUCH THAT THE
GROUND PIN IS UP (ABOVE PHASE AND NEUTRAL BLADES). THE MOUNTING POSITION FOR ALL STRAIGHT BLADE, HORIZONTALLY ORIENTED,
NEMA 5 AND 7 RECEPTACLES SHALL BE SUCH THAT THE NEUTRAL BLADE IS UP (ABOVE THE PHASE BLADE).
14. ALL ABOVE COUNTER DEVICES, LIGHT SWITCHES, RECEPTACLES AND TELE/DATA ROUGH-INS, TO BE MOUNTED AT THE SAME ELEVATION.
COORDINATE WITH ARCHITECTURAL CASEWORK ELEVATIONS, SECTIONS AND WALL TYPES.
15. ALL WORK INCLUDING CIRCUITS, CONDUIT AND OVER CURRENT DEVICES REQUIRED FOR COMPLETE INSTALLATION IS NEW UNLESS SPECIFICALLY
OTHERWISE NOTED.
16. IF OUTLETS BECOME BACK TO BACK THEY ARE TO BE MOVED OR SEPARATED BY 6" AND USE PUTTY PACKS. IF BOXES CANNOT BE MOVED AND FALL
BACK TO BACK SEPARATE THE STUD CAVITY WITH DRYWALL ON THE BACK SIDE AND A HEADER OR BLOCKING ABOVE THE OUTLET TO NAIL OFF THE
DRYWALL.
ELECTRICAL EQUIPMENT DESIGNATION METHOD
A,B,C,D
INDEX
H -480/277V OR 480V
L -208/120V
(blank) - TRANSFORMER
(blank) - NORMAL
C -CRITICAL
LS -LIFE SAFETY
LR -LEGALLY REQUIRED
OS -OPTIONAL STANDBY
EQUIPMENT TYPE
VOLTAGE
B -BASEMENT
1 -FIRST LEVEL
2 -SECOND LEVEL
3 -THIRD LEVEL
R -LOWER / UPPER ROOF LEVEL
FLOOR LEVEL DESIGNATION
T
CT
#
M
M
TV
TVM
MM
IC
MI
VC
TCC
CCTV
MTV
DR
IC
MI
MD
ML
CR
SCP
DC
K
M
CM
D
WM
J
D
S
SP
N L E
XX' xxxV WIRE WAY
XX' xxxV BUS DUCT
G
DRAWING BLOCK TITLE
SCALE: 1/8" = 1'-0" 0 16'8'4'
N
xxAF
yyAT
xxAF
yyAT
CT
zzA
zzA
K2
XX-XX-X-X
3
MO
ST
1
A1
E-401
A1
E-501
A1
E-301
GENERAL ELECTRICAL NOTES
SECTION INDICATOR: REFERENCE SECTION LOCATION THROUGH AN AREA
FOR ADDITIONAL INFORMATION.
KEYNOTE INDICATOR: REFERENCE SHEET KEYNOTE LOCATION FOR
ADDITIONAL INFORMATION.
DETAIL INDICATOR: REFERENCE DETAIL LOCATION FOR ADDITIONAL
INFORMATION.
DRAWING BLOCK
TITLE INDICATOR:
REFERENCE DRAWING MODULE LOCATION FOR
ADDITIONAL INFORMATION.
MATCH LINE
INDICATOR:
REFERENCE SHEET LOCATION FOR ADDITIONAL
INFORMATION.
REVISION INDICATOR: REFERENCE TITLE BLOCK LOCATION FOR ADDITIONAL
INFORMATION.
2'x4' FIXTURE
SUSPENDED FIXTURE
WALL MOUNTED FIXTURE
LUMINAIRE STRIP TYPE FIXTURE
DOUBLE OR SINGLE HEAD SPOT LIGHT
IN-GROUND OR FLOOR MOUNTED FIXTURE
POLE MOUNTED SITE LIGHTING FIXTURE
SINGLE LUMINAIRE SITE LIGHTING FIXTURE
TWIN LUMINAIRE SITE LIGHTING FIXTURE
BOLLARD TYPE SITE LIGHTING FIXTURE
LIGHTING OR POWER PANEL, RECESSED
LIGHTING OR POWER PANEL, SURFACE
DISTRIBUTION PANEL
LIGHTING OR POWER PANEL ON NORMAL/GENERATOR
FEEDER
DISTRIBUTION PANEL ON NORMAL/GENERATOR FEEDER
MOTOR CONTROL CENTER (MCC)
CURRENT TRANSFORMER CABINET
MOTOR
METER
METER AND SOCKET
MASTER ANTENNA SYSTEM OUTLET (MATV)
EQUIPMENT CABINET
EQUIPMENT RACK-WALL MOUNTED
EQUIPMENT RACK-FREE STANDING
TERMINAL CABINET WITH 3/4" PLYWOOD BACKING
PLYWOOD BACKBOARD
CCTV COAXIAL CABLE OUTLET AND POWER OUTLET
CCTV MONITOR OUTLET
ELECTRIC DOOR OPENER
INTERCOM UNIT -FLUSH MOUNT
MASTER INTERCOM AND DIRECTORY UNIT
MOTION DETECTOR
SECURITY DOOR ALARM MAGNETIC LOCK
SECURITY CARD READER. "WP" INDICATES
WEATHER-PROOF
SECURITY CONTROL PANEL
SECURITY DOOR CONTACTS
SECURITY EXIT PUSH BUTTON
SECURITY KEYPAD
EMT ELECTRICAL METALLIC TUBING
OCP OVERCURRENT PROTECTION
PHASE
ETR EXISTING TO REMAIN
OD OUTSIDE DIAMETER, OVERFLOW DRAIN
EWC ELECTRIC WATER COOLER
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OL OVERLOAD
A AMPERES
FCU FAN COIL UNIT
P POLE, PHASE, PARALLEL
AF AMPERE FUSE
FP FIRE PUMP
PE PNEUMATIC ELECTRIC
AFC ABOVE FINISHED COUNTER
PF POWER FACTOR
AFF ABOVE FINISHED FLOOR
PH PHASE
AFG ABOVE FINISHED GRADE
PTAC PACKAGED TERMINAL AIR CONDITIONER
G GROUND, GALLONS
PVC POLYVINYL CHLORIDE CONDUIT/PIPE
AIC AMPERES INTERRUPTING CAPACITY
GC GENERAL CONTRACTOR
RCPT RECEPTACLE
AL ALUMINUM
GFI GROUND FAULT INTERRUPTING
GFCI GROUND FAULT CIRCUIT
RGS RIGID GALVANIZED CONDUIT
RM ROOM
ATS AUTOMATIC TRANSFER SWITCH
AVG AVERAGE
HHWP HEATING HOT WATER PUMP
RPS REVOLUTIONS PER SECOND
BAS BUILDING AUTOMATION SYSTEM
HOA HAND-OFF-AUTOMATIC
RTU ROOF TOP UNIT
B/I BYPASS ISOLATION
BE BOTTOM ELEVATION
HP HORSEPOWER
BMS BUILDING MANAGEMENT SYSTEM
ST SHUNT TRIP
Hz HERTZ
STD STANDARD
C CONDUIT
IAC INSTRUMENTATIONS AND CONTROLS
SW SWITCH
CB CIRCUIT BREAKER
ID INSIDE DIAMETER
TBD TO BE DETERMINED
CBA COLOR BY ARCHITECT
TBI TO BE INSTALLED
CCW COUNTERCLOCKWISE
INT INTERIOR
TBR TO BE REMOVED
CH CHILLER
JP JOCKEY PUMP
TC TEMPERATURE CONTROLS
CHWP CHILLED WATER PUMP
TCC TEMPERATURE CONTROLS CONTRACTOR
kW KILOWATT
TR TAMPER RESISTANT
CMT CONDUIT EMPTY
KVA KILOVOLT AMPS
COMPR COMPRESSOR
LBS POUNDS
TF TRANSFER FAN
COND CONDENSER
LSI, LSIG TRIP TYPE -LONG, SHORT, INSTANTANEOUS, GROUND FAULT
TRANS TRANSITION
CONV CONVECTOR
LTG LIGHTING
CT COOLING TOWER
UH UNIT HEATER
CU CONDENSING UNIT, COPPER
MC MECHANICAL CONTRACTOR
UON UNLESS OTHERWISE NOTED
CUH CABINET UNIT HEATER
MCA MINIMUM CIRCUIT AMPS
UV UNIT VENTILATOR
CUV CLASSROOM UNIT VENTILATOR
MCC
V VOLTS
CW CLOCKWISE
VAV VARIABLE AIR VOLUME
CWP CONDENSER WATER PUMP
VB VACUUM BREAKER
D DEDICATED CIRCUIT
VERT VERTICAL
DC DIRECT CURRENT
MOP MAXIMUM OVERCURRENT PROTECTION
VF VENTILATION FAN
DS DISCONNECT SWITCH
MTD MOUNTED
VFD VARIABLE FREQUENCY DRIVE
MV MEDIUM VOLTAGE
W WIRE, WATT
NA NOT APPLICABLE
WP WEATHERPROOF
NEC NATIONAL ELECTRIC CODE
EC ELECTRICAL CONTRACTOR
NIC NOT IN CONTRACT
NL NIGHT LIGHT
WSHP WATER SOURCE HEAT PUMP
EFF EFFICIENCY
NOM NOMINAL
EL ELEVATION
CUSTOMER METER
DEMAND METER (UTILITY)
WATTHOUR METER (UTILITY)
DUPLEX CONVENIENCE RECEPTACLE ON
EMERGENCY/STANDBY CIRCUIT
DOUBLE DUPLEX CONVENIENCE RECEPTACLE ON
EMERGENCY/STANDBY CIRCUIT
MULTI-OUTLET ASSEMBLY
MULTI-OUTLET ASSEMBLY
FLUSH MOUNT FLOOR BOX, ADJUSTABLE, WITH BOTH
POWER AND VOICE/DATA RECEPTACLES
JUNCTION BOX
TOGGLE DISCONNECT SWITCH
THERMAL MOTOR SWITCH WITH HANDLE GUARD AND
PADLOCK CAPABILITY, "P"-INDICATES PILOT LIGHT
PHASE, NEUTRAL, GROUND
PHASE, PHASE, NEUTRAL, GROUND
PHASE, PHASE, PHASE, NEUTRAL, GROUND
PHASE, PHASE, NEUTRAL, NEUTRAL, GROUND
PHASE, PHASE, GROUND
PHASE, PHASE, PHASE, GROUND
HOMERUN
PHASE, NEUTRAL, GROUND, HOMERUN
CIRCUIT BREAKER (OPEN), "xxAF" INDICATES FRAME
SIZE, "yyAT" INDICATES TRIP SIZE
CIRCUIT BREAKER (ENCLOSED), "xxAF" INDICATES
FRAME SIZE, "yyAT" INDICATES TRIP SIZE
CURRENT TRANSFORMER CABINET
DISCONNECT SWITCH UNFUSED
DISCONNECT SWITCH AIR BREAK WITH FUSE,"zzA"
INDICATES FUSED RATING
FUSE, "zzA" INDICATES FUSED RATING
OVERLOAD RELAY
GROUNDING CONNECTION-SYSTEM AND OR EQUIPMENT
KIRK KEY INTERLOCK SYSTEM
LIGHTNING ARRESTER AND GROUNDING TO PROTECT
ALL PHASES
MOTOR AND LABEL, "3" DENOTES HORSEPOWER
MOTOR OPERATOR FOR CIRCUIT BREAKERS OR SWITCH
RESISTOR
SHUNT TRIP
MAGNETIC STARTER WITH NEMA SIZE INDICATED
GENERATOR
BUS DUCT OR BUS WAY
WIRE WAY
TRANSFER SWITCH
REFERENCE SYMBOLS
ABBREVIATIONS AND TERMS
1
REFER TO ADDITIONAL
SHEET FOR CONTINUATION
FLOOR PLAN OVERLAP BEYOND AREA
EXTENSION
PLAN
DRAWING MODULE LOCATION
(IDENTIFYING LOWER LEFT OF MULTIPLE MODULES)
GRAPHIC SCALENUMERIC SCALE NORTH ARROW
SECTION LOCATION
IN DRAWING MODULE
SECTION LOCATION AT SUBSET SHEET
PLAN
BEYOND AREA
EXTENSION
DETAIL LOCATION IN
DRAWING MODULE
DETAIL LOCATION AT
SUBSET SHEET
LARGE SCALE VIEW
LOCATION IN DRAWING
MODULE
LARGE SCALE VIEW
LOCATION AT SUBSET SHEET
REVISION CLOUD
REVISION INDICATOR
11 1
KEYNOTE INDICATORS
AREA LEADER
LINE LEADER
POINT LEADER
NUMERICAL CHARACTER
RELATES TO ITEM
A1
M
P
Ø
SYMBOL DESCRIPTION
CEIL WALL FL.
MOUNTING
DESCRIPTION
LIGHTING INDICATOR: REFERENCE SCHEDULE LOCATION
FOR ADDITIONAL INFORMATION.
"A" = FIXTURE TYPE, REFER TO FIXTURE
SCHEDULE,
"2" = CIRCUIT NUMBER, "a" = SWITCH
IDENTIFICATION
A
a 2
TS TRANSFER SWITCH
DUPLEX CON. OUTLET - GFI PROTECTED (+44" AFF)
FIRE ALARM CONTROL CABINET
FIRE ALARM ANNUNCIATOR (REMOTE)
FIRE ALARM PULL STATION
FIRE ALARM HEAT DETECTOR (RATE OF RISE)
FIRE ALARM SMOKE DETECTOR (PHOTO-ELECTRIC)
TAMPER SWITCH (SUPERVISORARY)
FLOW SWITCH
FIRE FIGHTERS TELEPHONE JACK
MAGNETIC DOOR HOLDER
FIRE ALARM BELL/STROBE COMBINATION
FIRE ALARM STROBE
FIRE ALARM SPEAKER
FIRE ALARM CHIME
FACP
FARA
F
DH
F
FF
F
F F
FIRE ALARM SMOKE DUCT DETECTOR
NOTIFICATION APPLIANCE CABINETNAC
F
FIRE ALARM SPEAKER/STROBE COMBINATION
FIRE ALARM HORN/STROBE COMBINATION
FIRE ALARM HORN
F
CONTACTOR
TRANSFER SWITCH
MANUAL STARTER (P - PILOT LIGHT)
MAGNETIC MOTOR STARTER
COMBINATION MAGNETIC MOTOR STARTER &
DISCONNECT
P
RESCUE ASSISTANCE STATIONRA
TS
KB
IAM
ZAM
CR
RTS
SA
SE
SSC
B R
B S
C
H2
D
PS
PIV
KEY REPOSITORY (KNOX BOX)
INDIVIDUALLY ADDRESSABLE MODULE-MONITOR
(PROVIDES ADDRESS FOR CONTACT)
INDIVIDUALLY ADDRESSABLE MODULE-RELAY
(PROVIDES CONTACT CLOSURE)
CONTROL RELAY
REMOTE STATION FOR DUCT DETECTOR USED AT
DUCT WORK OPENING
AREA TYPE SMOKE DETECTOR USED AT DUCT WORK
OPENING
ELEVATOR RECALL WITH AUXILIARY CONTACTS
SELF CONTAINED SMOKE DETECTOR-SINGLE STATION
TYPE
BEAM SMOKE DETECTOR, "R"-INDICATES RECEIVER
BEAM SMOKE DETECTOR, "S" INDICATES SENDING UNIT
CARBON MONOXIDE DETECTOR. LINE VOLTAGE WITH
BATTERY BACKUP
HYDROGEN DETECTOR
MOTOR OPERATED FIRE/SMOKE DUCT DAMPER
LOW PRESSURE SWITCH, BY DIVISION 15
POST INDICATOR VALVE, BY DIVISION 15
F
F
F
CAPACITORC
F F
FP
See Drawing
CERTIFICATION
626 North Illinois Street
Indianapolis, Indiana 46204
Phone: (317) 635-5030
Website: www.browningday.com
Checked By:
Scale:
Issue Date:
Drawn By:
CDG No.:
Owner
6/18/21 10:56:37 AM C:\Users\cmikaitis\Documents\21028-R20-Forum-Carmel_MEP_CMikaitis.rvtE-000
ELECTRICAL SYMBOLS
AND ABBREVIATIONS
21028
DAN MITCHELL
JERRY TRAVIS
06/18/21
FORUM Credit Union
Branch Renovation
2259 E 116th Street,
Carmel, IN 46032
Construction Documents
11313 USA Parkway
Fishers, IN 46038
Phone: (317) 558-6000
Website: www.forumcu.com
FORUM Credit Union
9229 Delegates Row Suite 150
Indianapolis, IN 46240
Phone: (317) 781-6200
Website: www.circledesigngroup.com
Circle Design Group
MEP Engineer
REVISION SCHEDULE
Rev. # Revision Description Issue Date
07/06/21