Loading...
HomeMy WebLinkAboutGN010.1GENERAL PROJECT NOTES 1. DO NOT SCALE DRAWINGS. 2. THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, AND THE MAJOR ARCHITECTURAL ELEMENTS. AS GRAPHIC DOCUMENTS THE DRAWINGS DO NOT INDICATE OR DESCRIBE THE WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED THE CONTRACTOR SHALL STUDY THE DRAWINGS AND THEIR GENERAL INFERENCE TO FURNISH THE ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 3. EACH ITEM REPRESENTED IN THE DRAWING SET OR REFERRED TO IN THE SPECIFICATIONS ARE TO BE PROVIDED BY, COORDINATED BY, AND INSTALLED BY THE CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE. 4. DIMENSIONS ARE TAKEN TO FACE OF METAL STUD, FACE OF CONCRETE, FACE OF MASONRY, FACE OF EXISTING FINISHES, AND COLUMN LINES UNLESS NOTER OTHERWISE. CLEAR (CLR) DIMENSIONS INDICATE FINISH SURFACE TO FINISH SURFACE SPANS BETWEEN WALL OR FROM FINISH SURFACE OF WALL TO LATCH/HINGE OF ADJACENT DOOR OR CENTERLINE OF PLUMBING FIXTURES. 5. LETTER DESIGNATIONS WITHIN A DIMENSION STRING (SUCH AS "A", "B", "C" AND SO ON) INDICATE THAT THE DIMENSION IS TO BE FIELD DETERMINED AND IT IS TO BE EQUAL TO OTHER DIMENSIONS OF THE SAME LETTER THROUGHOUT THAT SPECIFIC DRAWING SHEET, BUT NOT TO THE SAME DESIGNATION ON OTHER DRAWING SHEETS. 6. USE OF "EQUAL" OR "EQ" WITHIN A DIMENSION STRING INDICATES A DIMENSION THAT IS TO BE EQUAL ONLY RELATIVE TO OTHER EQUAL CALLOUTS ON THE SAME DIMENSION STRING IN WHICH IT APPEARS. DIMENSIONS CALLED OUT AS EQUAL ON TWO DIFFERENT DIMENSION STRINGS ARE NOT NECESSARILY EQUAL TO EACH OTHER. 7. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE BUILDING ELEMENTS. CONTACT THE ARCHITECT WITH CONFLICTS, DISCREPANCIES, AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. WRITTEN DOCUMENTATION SHALL BE PROVIDED BY THE CONTRACTOR REGARDING SUCH ITEMS. 8. FLOORS SHALL SLOPE TO FLOOR DRAINS. SLOPES SHALL COMPLY WITH ADA ACCESSIBILITY GUIDELINES. 9. WALL FRAMING, INSULATION, SHEATHING, AND FINISHES SHALL EXTEND FROM THE TOP OF SLAB TIGHT TO THE UNDERSIDE OF THE DECK ABOVE UNLESS NOTED OTHERWISE. 10. REFER TO SPECIFICATIONS FOR EACH ITEM REPRESENTED WITHIN THE DRAWING SET. 11. WALL STUD FRAMING CONTRACTOR SHALL PROVIDE IN-WALL BLOCKING FOR WALL MOUNTED OWNER PROVIDED AND CONTRACTOR PROVIDED ITEMS REPRESENTED WITHIN THE DRAWINGS AND SPECIFICATIONS. 12. CONTRACTOR TO PROVIDE BACKER ROD AND SEALANT, OF A TYPE APPROPRIATE TO EACH CONDITION, BETWEEN MATERIALS BOTH SIMILAR AND DISSIMILAR THROUGHOUT THE INTERIOR AND EXTERIOR OF THE BUILDING. (COLORS TO BE SELECTED BY ARCHITECT) 13. CONTRACTOR SHALL VERIFY THE EXISTING CONDITIONS AND PROMPTLY NOTIFY THE OWNER AND THE ARCHITECT OF ANY CONDITIONS THAT ARE IN CONFLICT WITH THE PROPOSED WORK OR ARE IN VARIANCE WITH THE CONSTRUCTION DOCUMENTS. 14. CONTRACTOR SHALL PROTECT EXISTING MATERIALS, COMPONENTS, AND FEATURES DESIGNATED TO REMAIN, BE SALVAGED, AND/OR REUSED. 15. CONTRACTOR SHALL COORDINATE WITH THE OWNER AND GOVERNING AUTHORITIES TO ESTABLISH CONSTRUCTION TRAFFIC ACCESS TO THE SITE AND DESIGNATED CONSTRUCTION ACCESS THROUGHOUT THE BUILDING. 16. AT COMPLETION OF THE CONTRACT WALLS, CEILINGS, FLOORS, ETC. ARE TO BE CLEAN OF DEBRIS AND DUST RELATED TO DEMOLITION AND CONSTRUCTION. 17. EACH EXPOSED AND/OR VISIBLE SURFACE OF THE BUILDING IS TO BE FINISHED. UNFINISHED EXPOSED MATERIALS ARE NOT ACCEPTABLE. SITE LOCATION PLAN MERCHANT'S POINTEAAA WAY116TH STREET KEYSTONE PARKWAYPROJECT SITE NORTH BUILDING CODE SUMMARY GOVERNING CODE: 2014 INDIANA BUILDING CODE AND LIST OTHER APPLICABLE CODES PROJECT SUMMARY: MINOR INTERIOR RENOVATION INCLUDING REWORK OF EXISTING MECHANICAL AND ELECTRICAL SYSTEMS. CONSTRUCTION TYPE: [ EDIT ME: TYPE __ ] OCCUPANCY TYPES: B- BUSINESS BUILDING STORIES: 1 STORY BUILDING AREA: TOTAL SQUARE FOOTAGE: 3,000 SF OCCUPANCY COUNT: 20 OCCUPANTS FIRE RESISTANCE RATINGS: INTERIOR NON-LOAD BEARING WALLS: 1-Hr SPRINKLERS: NON-SPRINKLERED In accepting and utilizing any drawings or other data on any form of electronic media generated and provided by Browning Day and their consultants, the person and their organization covenants and agrees that all such drawings and data are instruments of service of Browning Day and its consultants who shall retain all common law, statutory law and other rights, including copyrights. The drawings are scaled but are not intended for use in construction. The use of electronic files submitted by Browning Day to the downloading party are provided under the terms and conditions defined in the Construction Documents, including, but not limited to Section 01 31 00 “Project Management and Coordination,” Paragraph 1.6. In accepting and utilizing the files it is further agreed not to use these drawings and digital data, in whole or in part, for any purpose or project other than the project which is subject to this Agreement. The downloading party agree to waive all claims against Browning Day and its consultants resulting in any way from any unauthorized changes or reuse of the drawings and date for any other project by anyone other than Browning Day or its consultants. In addition, the person and their organization agree, to the fullest extent permitted by law, to indemnify and hold Browning Day and its consultants harmless from any damage, liability or cost, including reasonable attorneys' fees and cost of defense, arising from any changes made by anyone other than Browning Day and its consultants from any reuse of the drawings and data without the prior written consent of Browning Day. Under no circumstances shall transfer of the drawings and other instruments of service on electronic media for use by the downloading party be deemed a sale by Browning Day. Browning Day makes no warranties, either expressed or implied, of merchantability and fitness for any particular purpose. The person making this agreement warrants that they have authority to enter into this agreement on behalf of their organization and Browning Day can rely on said authority. USE OF ELECTRONIC FILES ABBREVIATIONS AFF ABOVE FINISH FLOOR AL ALUMINUM B.O. BOTTOM OF BOT BOTTOM CIP CAST-IN-PLACE CJ CONTROL JOINT CL CENTERLINE CLR CLEAR CMU CONCRETE MASONRY UNIT CONC CONCRETE CPT CARPET CT CERAMIC TILE DIA DIAMETER DN DOWN DWG DRAWING EA EACH EJ EXPANSION JOINT ELEC ELECTRIC(AL) ELEV ELEVATOR EQ EQUAL EWC ELECTRIC WATER COOLER EXIST EXISTING EXT EXTERIOR FD FLOOR DRAIN FE FIRE EXTINGUISHER FIN FINISH(ED) SI SQUARE INCH SIM SIMILAR SPEC SPECIF- ICATIONS SOL SOLID SURFACE SS STAINLESS STEEL STD STANDARD STOR STORAGE STL STEEL T TREAD(S) T&G TONGUE AND GROOVE T.O. TOP OF TOC TOP OF CURB TOW TOP OF WALL TYP TYPICAL VCT VINYL COMPOSITION TILE WC WALL- COVERING WD WOOD FLR FLOOR FT FOOT / FEET GYP. BD. GYPSUM BOARD GL GLASS HM HOLLOW METAL HR HOUR IHM INSULATED HOLLOW METAL JAN JANITOR KIT KITCHEN LAM LAMINATE LF LINEAR FOOT MAX MAXIMUM MIN MINIMUM MTL METAL OPP OPPOSITE P / PT PAINT POR PORCELAIN TILE QT QUARRY TILE R RISER(S) RD ROOF DRAIN RM ROOM RO ROUGH OPENING SF SQUARE FOOT SHT SHEET STRUCTURAL DECK ABOVE 5/8" GYP. BD. EACH SIDE METAL STUD FRAMING AT 16" or 24" O.C. COORDINATE LOCATIONS WITH STRUCTURAL AND OTHER TRADES. PROVIDE 3" SOUND ATTENUATION BATT INSULATION UNLESS OTHERWISE NOTED TOP OF SLAB ACOUSTICAL SEALANT EACH SIDE ACOUSTICAL SEALANT EACH SIDE SET METAL STUD TRACK IN BED OF SEALANT. STUD SIZE FIRE RATINGS SEE DETAIL CONTRACTOR TO FULLY COMPLY WITH UL INSTALLATION AND CONSTRUCTION REQUIREMENTS B "B" DENOTES TO PROVIDE BATTS OF TYPE SHOWN ME METAL STUD WALL TYPE ME0 ME1 ME2 ME3 7/8" FURRING 1 1/2" FURRING 2 1/2" STUD 3 5/8" STUD ME4 ME6 ME8 4" STUD 6" STUD 8" STUD ME 1-HR FIRE PARTITION UL: U-419 ME STC: 45 to 49 WITH 3" SAB GYPSUM ASSOCIATION WP-1070 SECTION ME ME 1 NOT F O R CON S T R U C TI O N See Drawing CERTIFICATION 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.browningday.com Checked By: Scale: Issue Date: Drawn By: Project No.: Owner 6/16/2021 4:18:43 PM \\bdmd.local\UEM\UserShare\kthompson\Documents\FORUM_Carmel Reno_kthompson.rvt0.01 Project Data, Code Summary, and Sheet Index 21I010 Author Checker 6/15/21 FORUM Credit Union Branch Renovation 2259 E 116th Street, Carmel, IN 46032 Construction Documents 11313 USA Parkway Fishers, IN 46038 Phone: (317) 558-6000 Website: www.forumcu.com FORUM Credit Union 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 Phone: (317) 781-6200 Website: www.circledesigngroup.com Circle Design Group MEP Engineer SHEET INDEX Sheet Number Sheet Name CONSTRUCTION DOCUMENTS00 - PROJECT GENERAL 0.00 Cover Sheet X 0.01 Project Data, Code Summary, and Sheet Index X 0.02 Specifications X 09 - ARCHITECTURAL A0.01-L Life Safety Plans X A1.00 Demo Plan X A1.01 Floor Plan X A1.01-A1 Teller Pod Millwork X A1.01-A2 Enlarged Plans & Elevations X A1.01-F 1st Floor, Finish Plan X A5.01 Room Finish and Material Schedules X A7.01 Interior Details X A8.01 Door and Window Details X 10 - ELECTRICAL E101 Placeholder 11 - MECHANICAL M101 Placeholder REVISION SCHEDULE Rev. # Revision Description Issue Date 07/06/21