From: Blunk, Alan
Sent: Friday, June 18, 2021 3:35 PM
To: Katie Thompson
Cc: Callahan, Sean; Mays, Rex
Subject: RE: Question regarding filing exemption - Carmel IN bank branch renovation
Hello Ms. Thompson,
Based on the information and attachment provided, the project is EXEMPT from filing with the State of Indiana DHS Plan
Review section in accordance with 675 IAC 12-6-4.
675 IAC 12-6-4 Exemptions from design release requirement
Authority: IC 22-13-2-13
Affected: IC 4-21.5; IC 12-13-4-3; IC 22-15-3
Sec. 4.
(b) Design releases are necessary for the remodeling or altering of all Class 1 structures, except work limited to one (1) or more of the
following:
(3) Electrical work as follows:
(A) Replacement in the same location of electrical equipment or devices of a similar type and rating, including an increase in current
capacity in nonhazardous areas where there is no change in voltage or phases.
(D) Installation of branch circuits not exceeding the capacity of the electrical distribution system within the existing building.
(E) Low-energy power, control, and signal circuits of Classes II and III as defined in the Indiana Electrical Code except circuits for
fire detection or fire alarm systems.
(G) Except for fire detection or fire alarm systems, electrical wiring, devices, appliances, apparatus, or equipment:
(i) operating at less than twenty-five (25) volts; and
(ii) not capable of supplying more than fifty (50) watts of energy.
(4) Mechanical work as follows:
(B) Replacement of mechanical appliances and equipment with a similar type and rating in the same location.
(5) Miscellaneous work as follows:
(A) Painting, papering, and replacement of coverings on:
(i) walls;
(ii) ceilings; or
(iv) floors;
and similar finish work, including replacement or reglazing of glass.
(B) Cases, counters, and partitions not over six (6) feet in height.
(D) Installation of one (1) or more non load-bearing partitions not to exceed a total of one hundred (100) lineal feet in length provided
it is not part of a corridor or a partition that is required to be of fire-resistive construction.
2
(c) All additions or alterations permitted by this subdivision [sic.] shall be documented by the installer and kept on file with the
maintenance and testing records required by 675 IAC 22 and 675 IAC 28, specifically the applicable editions of NFPA 13 and NFPA
25.
(d) The design release requirements including filing of plans and specifications shall apply for any work otherwise exempted by
subsection (b) when a part of, supplemental to, or an accessory of a construction project that otherwise requires a design release.
(e) Construction work on a Class 1 structure exempted from the design release requirements under this section is not exempt from
compliance with other rules of the commission.
Project may be required to be submitted to local jurisdiction.
Thank you,
Alan L. Blunk RA CPE CBI FI FII | Plan Review Section Chief
Division of Fire and Building Safety | Plan Review Branch
Indiana Department of Homeland Security
302 West Washington Street, Room E-245
Indianapolis, IN 46204
Tel: 317-232-6422
Email: ablunk@dhs.in.gov
Web: http://www.in.gov/dhs/3658.htm
From: Katie Thompson <kthompson@browningday.com>
Sent: Friday, June 18, 2021 1:19 PM
To: Plan Review <planreview@dhs.in.gov>
Subject: RE: Question regarding filing exemption - Carmel IN bank branch renovation
Hello, I have attached the complete set of Construction Documents to demonstrate the scope of work.
Project square footage (overall): 3,000SF
Address: 2259 E 116th Street, Carmel, IN 46032
Project Description: Minor interior remodel including new finishes, millwork, rework of existing electrical and mechanical
systems. Only one new office will be constructed (Office 115).
Please let me know if there are any additional questions!
Thank you,
Katie Thompson, IIDA, LEED AP ID+C, Fitwel Ambassador
Senior Interior Designer, Associate
To help protect your priv acy, Microsoft Office prevented automatic download of this picture from the Internet.browning day
d 317.613.4293
p 317.635.5030
To help protect your priv acy, Microsoft Office prevented automatic download of this picture from the Internet.designers of possiblity
From: Plan Review <planreview@dhs.in.gov>
Sent: Friday, June 18, 2021 12:21 PM
3
To: Katie Thompson <kthompson@browningday.com>
Subject: RE: Question regarding filing exemption - Carmel IN bank branch renovation
Hello Ms. Thompson,
If you are requesting an exemption from filing with the State of Indiana DHS Plan Review section in accordance with 675
IAC 12-6-4, please provide the project address, reference plans, and description of the complete scope of work.
Thank you.
From: Katie Thompson <kthompson@browningday.com>
Sent: Friday, June 18, 2021 9:37 AM
To: Plan Review <planreview@dhs.in.gov>
Subject: Question regarding filing exemption - Carmel IN bank branch renovation
Hello – I am working on a minor interior renovation for FORUM Credit union in Carmel, Indiana. We have determined that
the scope falls under requirements for a State Design Release. However, the local permit office in Carmel is requiring a
written statement from the state. How do we go about receiving that?
Happy to share construction documents for review if required.
Thank you!
Katie Thompson, IIDA, LEED AP ID+C, Fitwel Ambassador
Senior Interior Designer, Associate
d 317.613.4293
p 317.635.5030
[EXTERNAL EMAIL] **** Exercise caution. DO NOT open attachments or click links from unknown senders or unexpected emails.
If the sender is an employee of Shiel Sexton, please consider the possibility of email phishing and validate with them directly before
replying or clicking on links/attachments. ****