HomeMy WebLinkAboutA011.1OFFICE 115 OFFICE 105 OFFICE 106 FLEX OFFICE 108 MECH 107 BREAK 109 RESTROOM 110 WORK 111 VAULT 112 OFFICE 104 VESTIBULE 100 TELLERS 113 5' - 0"4' - 6" 2' - 7"A1.01-A2 A1.01-A2 6 11' - 3 9/32" LOBBY 101 4 A1.01-A2 1 A1.01-A1 1 A1.01-A1 211' - 9 3/8"7 7' - 5"A1.01-A2 5 D111D112EXEX D115 EX EX EXEX D104 D105 D106 D1084' - 6"ME3 ME3 ME3 ME3 ME3 ME3 5' - 7" 2' - 4 1/8" 3' - 3 3/16" A1.01-A28 D105A 1 BLDG 2 BLDG 1' - 8"GENERAL PLAN NOTES 1. DO NOT SCALE DRAWINGS. 2. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF CONCRETE, FACE OF MASONRY, FACE OF EXISTING FINISHES, AND COLUMN LINES UNLESS SPECIFICALLY NOTED OTHERWISE. FINISHED (FIN, FD) OR CLEAR (CLR) DIMENSIONS INDICATE FINISH SURFACE TO FINISH SURFACE SPANS BETWEEN WALLS OR FROM FINISH SURFACE OF WALL TO LATCH/HINGE OF ADJACENT DOOR OR CENTERLINE OF PLUMBING FIXTURES. 3. LETTER DESIGNATIONS WITHIN A DIMENSION STRING (SUCH AS "A", "B", "C" AND SO ON) INDICATE THAT THE DIMENSION IS TO BE FIELD DETERMINED AND IT IS TO BE EQUAL TO OTHER DIMENSIONS OF THE SAME LETTER THROUGHOUT THAT SPECIFIC DRAWING SHEET, BUT NOT TO THE SAME DESIGNATION ON OTHER DRAWING SHEETS. 4. USE OF "EQUAL" OR "EQ" WITHIN A DIMENSION STRING INDICATES A DIMENSION THAT IS TO BE EQUAL ONLY RELATIVE TO OTHER EQUAL CALLOUTS ON THE SAME DIMENSION STRING IN WHICH IT APPEARS. DIMENSIONS CALLED OUT AS EQUAL ON TWO DIFFERENT DIMENSION STRINGS ARE NOT NECESSARILY EQUAL TO EACH OTHER. 5. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE BUILDING ELEMENTS. CONTACT THE ARCHITECT WITH CONFLICTS, DISCREPANCIES, AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. WRITTEN DOCUMENTATION SHALL BE PROVIDED BY THE CONTRACTOR REGARDING SUCH ITEMS. 6. STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LOW VOLTAGE ELEMENTS ARE SHOWN FOR REFERENCE ONLY. VERIFY EACH ELEMENT WITH THE ASSOCIATED ENGINEER'S DRAWINGS. COORDINATE CONFLICTS WITH THE ARCHITECT. 7. WALL FRAMING, INSULATION, SHEATHING, AND FINISHES SHALL EXTEND FROM THE TOP OF SLAB TIGHT TO THE UNDERSIDE OF THE DECK ABOVE UNLESS NOTED OTHERWISE. PARTIAL HEIGHT WALLS ARE NOTED WITH TOP OF WALL ELEVATIONS. 8. REFER TO SPECIFICATIONS FOR EACH ITEM REPRESENTED WITHIN THE DRAWING SET. 9. STUD WALL CONTRACTOR SHALL PROVIDE IN-WALL BLOCKING FOR WALL MOUNTED OWNER PROVIDED AND CONTRACTOR PROVIDED ITEMS REPRESENTED WITHIN THE DRAWINGS AND SPECIFICATIONS. 10. GENERAL CONTRACTOR TO PROVIDE BACKER ROD AND SEALANT OF A TYPE APPROPRIATE TO EACH CONDITION, BETWEEN MATERIALS BOTH SIMILAR AND DISSIMILAR THROUGHOUT THE INTERIOR AND EXTERIOR OF THE BUILDING. (COLORS TO BE SELECTED BY ARCHITECT) 101 WW B 1 WALL TAG: SEE SHEET 0.01 FOR WALL TYPE AND FIRE RATING REQUIREMENTS. SEE FINISH PLAN FOR WALL FINISHES. CODED NOTES OF VARYING TYPES: SEE SCHEDULES ON THIS SHEET DOOR TAG: SEE SHEET A8.01 SYMBOL LEGEND 1 BLDG NOT F O R CON S T R U C TI O N See Drawing CERTIFICATION 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.browningday.com Checked By: Scale: Issue Date: Drawn By: Project No.: Owner 6/16/2021 4:18:51 PM \\bdmd.local\UEM\UserShare\kthompson\Documents\FORUM_Carmel Reno_kthompson.rvtA1.01 Floor Plan 21I010 Author Checker 6/15/21 FORUM Credit Union Branch Renovation 2259 E 116th Street, Carmel, IN 46032 Construction Documents 11313 USA Parkway Fishers, IN 46038 Phone: (317) 558-6000 Website: www.forumcu.com FORUM Credit Union 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 Phone: (317) 781-6200 Website: www.circledesigngroup.com Circle Design Group MEP Engineer A1.01 1/4" = 1'-0" Floor Plan1 1st Floor Plan NORTH CODED BUILDING NOTES NO. NOTE 1 EXISTING STRUCTURAL COLUMN TO REMAIN. FRAME AS CLOSELY AS POSSIBLE AND ALIGN WALLS WITH NEW BULKHEAD ABOVE. 2 NEW CHECK WRITING COUNTER PROVIDED BY OWNER. REVISION SCHEDULE Rev. # Revision Description Issue Date 07/06/21