HomeMy WebLinkAboutA011.1OFFICE
115
OFFICE
105
OFFICE
106
FLEX
OFFICE
108
MECH
107
BREAK
109
RESTROOM
110
WORK
111
VAULT
112
OFFICE
104
VESTIBULE
100
TELLERS
113
5' - 0"4' - 6" 2' - 7"A1.01-A2
A1.01-A2
6
11' - 3 9/32"
LOBBY
101
4
A1.01-A2
1
A1.01-A1
1
A1.01-A1
211' - 9 3/8"7 7' - 5"A1.01-A2
5
D111D112EXEX D115
EX
EX
EXEX
D104
D105
D106 D1084' - 6"ME3
ME3
ME3
ME3
ME3
ME3
5' - 7"
2' - 4 1/8" 3' - 3 3/16"
A1.01-A28
D105A
1
BLDG
2
BLDG 1' - 8"GENERAL PLAN NOTES
1. DO NOT SCALE DRAWINGS.
2. DIMENSIONS ARE TAKEN TO FACE OF STUD, FACE OF
CONCRETE, FACE OF MASONRY, FACE OF EXISTING
FINISHES, AND COLUMN LINES UNLESS SPECIFICALLY
NOTED OTHERWISE. FINISHED (FIN, FD) OR CLEAR (CLR)
DIMENSIONS INDICATE FINISH SURFACE TO FINISH
SURFACE SPANS BETWEEN WALLS OR FROM FINISH
SURFACE OF WALL TO LATCH/HINGE OF ADJACENT
DOOR OR CENTERLINE OF PLUMBING FIXTURES.
3. LETTER DESIGNATIONS WITHIN A DIMENSION STRING
(SUCH AS "A", "B", "C" AND SO ON) INDICATE THAT THE
DIMENSION IS TO BE FIELD DETERMINED AND IT IS TO BE
EQUAL TO OTHER DIMENSIONS OF THE SAME LETTER
THROUGHOUT THAT SPECIFIC DRAWING SHEET, BUT
NOT TO THE SAME DESIGNATION ON OTHER DRAWING
SHEETS.
4. USE OF "EQUAL" OR "EQ" WITHIN A DIMENSION STRING
INDICATES A DIMENSION THAT IS TO BE EQUAL ONLY
RELATIVE TO OTHER EQUAL CALLOUTS ON THE SAME
DIMENSION STRING IN WHICH IT APPEARS. DIMENSIONS
CALLED OUT AS EQUAL ON TWO DIFFERENT DIMENSION
STRINGS ARE NOT NECESSARILY EQUAL TO EACH
OTHER.
5. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO
LOCATE BUILDING ELEMENTS. CONTACT THE ARCHITECT
WITH CONFLICTS, DISCREPANCIES, AND OMISSIONS
PRIOR TO COMMENCEMENT OF WORK. WRITTEN
DOCUMENTATION SHALL BE PROVIDED BY THE
CONTRACTOR REGARDING SUCH ITEMS.
6. STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING,
LOW VOLTAGE ELEMENTS ARE SHOWN FOR
REFERENCE ONLY. VERIFY EACH ELEMENT WITH THE
ASSOCIATED ENGINEER'S DRAWINGS. COORDINATE
CONFLICTS WITH THE ARCHITECT.
7. WALL FRAMING, INSULATION, SHEATHING, AND FINISHES
SHALL EXTEND FROM THE TOP OF SLAB TIGHT TO THE
UNDERSIDE OF THE DECK ABOVE UNLESS NOTED
OTHERWISE. PARTIAL HEIGHT WALLS ARE NOTED WITH
TOP OF WALL ELEVATIONS.
8. REFER TO SPECIFICATIONS FOR EACH ITEM
REPRESENTED WITHIN THE DRAWING SET.
9. STUD WALL CONTRACTOR SHALL PROVIDE IN-WALL
BLOCKING FOR WALL MOUNTED OWNER PROVIDED AND
CONTRACTOR PROVIDED ITEMS REPRESENTED WITHIN
THE DRAWINGS AND SPECIFICATIONS.
10. GENERAL CONTRACTOR TO PROVIDE BACKER ROD AND
SEALANT OF A TYPE APPROPRIATE TO EACH CONDITION,
BETWEEN MATERIALS BOTH SIMILAR AND DISSIMILAR
THROUGHOUT THE INTERIOR AND EXTERIOR OF THE
BUILDING. (COLORS TO BE SELECTED BY ARCHITECT)
101
WW
B
1
WALL TAG: SEE SHEET 0.01 FOR WALL TYPE
AND FIRE RATING REQUIREMENTS. SEE
FINISH PLAN FOR WALL FINISHES.
CODED NOTES OF VARYING TYPES: SEE
SCHEDULES ON THIS SHEET
DOOR TAG: SEE SHEET A8.01
SYMBOL LEGEND
1
BLDG
NOT
F
O
R
CON
S
T
R
U
C
TI
O
N
See Drawing
CERTIFICATION
626 North Illinois Street
Indianapolis, Indiana 46204
Phone: (317) 635-5030
Website: www.browningday.com
Checked By:
Scale:
Issue Date:
Drawn By:
Project No.:
Owner
6/16/2021 4:18:51 PM \\bdmd.local\UEM\UserShare\kthompson\Documents\FORUM_Carmel Reno_kthompson.rvtA1.01
Floor Plan
21I010
Author
Checker
6/15/21
FORUM Credit Union
Branch Renovation
2259 E 116th Street,
Carmel, IN 46032
Construction Documents
11313 USA Parkway
Fishers, IN 46038
Phone: (317) 558-6000
Website: www.forumcu.com
FORUM Credit Union
9229 Delegates Row, Suite 150
Indianapolis, IN 46240
Phone: (317) 781-6200
Website: www.circledesigngroup.com
Circle Design Group
MEP Engineer
A1.01 1/4" = 1'-0"
Floor Plan1 1st Floor Plan
NORTH
CODED BUILDING NOTES
NO. NOTE
1 EXISTING STRUCTURAL COLUMN TO REMAIN. FRAME AS
CLOSELY AS POSSIBLE AND ALIGN WALLS WITH NEW
BULKHEAD ABOVE.
2 NEW CHECK WRITING COUNTER PROVIDED BY OWNER.
REVISION SCHEDULE
Rev. # Revision Description Issue Date
07/06/21