HomeMy WebLinkAboutA011.4FLEX
OFFICE
108
MECH
107
BREAK
109
RESTROOM
110
OFFICE
106
OFFICE
105
OFFICE
115
WORK
111
OFFICE
104
VAULT
112
TELLERS
113
VESTIBULE
100
LOBBY
101
ACT-1
11' - 0"
ACT-1
8' - 6"
ACT-1
11' - 0"
ACT-1
9' - 0"
ACT-1
10' - 0"
ACT-1
10' - 0"
GYP.BD.
10' - 0"
ACT-1
10' - 0"
GYP. BD
8' - 3"
8"
ALIGN
ALIGN
ALIGN
EXISTING SKYLIGHT TO REMAIN
4
A7.01
P-3
GENERAL CEILING PLAN NOTES
1. DO NOT SCALE DRAWINGS.
2. GYP. BD. CEILINGS AND THEIR ASSOCIATED BULKHEADS
ARE TO BE PAINTED P-1 UNLESS NOTED OTHERWISE.
3. UNLIKE FLOOR PLAN DIMENSIONS, THOSE SHOWN ON
THE REFLECTED CEILING PLAN ARE FINISHED DIMINSIONS
UNLESS NOTED OTHERWISE.
CEILING ELEVATIONS ARE TO THE FINISHED FACE OF
THE CEILING FINISH MATERIAL.
BULKHEAD DIMENSIONS ARE TO THE FINISHED FACE
OF GYP. BD.
DIMENSIONS TO LIGHT FIXTURES ARE TO THE
CENTERPOINT OF THE FIXTURE, THE FINISHED EDGE
OF FIXTURE, OR TO THE CENTERLINE OF ASSOCIATED
CEILING GRID SYSTEM.
4. LETTER DESIGNATIONS WITHIN A DIMENSION STRING
(SUCH AS "A", "B", "C" AND SO ON) INDICATE THAT THE
DIMENSION IS TO BE FIELD DETERMINED AND IT IS TO BE
EQUAL TO OTHER DIMENSIONS OF THE SAME LETTER
THROUGHOUT THAT SPECIFIC DRAWING SHEET, BUT NOT
TO THE SAME DESIGNATION ON OTHER DRAWING
SHEETS.
5. USE OF "EQUAL" OR "EQ" WITHIN A DIMENSION STRING
INDICATES A DIMENSION THAT IS TO BE EQUAL ONLY
RELATIVE TO OTHER EQUAL CALLOUTS ON THE SAME
DIMENSION STRING IN WHICH IT APPEARS. DIMENSIONS
CALLED OUT AS EQUAL ON TWO DIFFERENT DIMENSION
STRINGS ARE NOT NECESSARILY EQUAL TO EACH
OTHER.
6. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE
BUILDING ELEMENTS. CONTACT THE ARCHITECT WITH
CONFLICTS, DISCREPANCIES, AND OMISSIONS PRIOR TO
COMMENCEMENT OF WORK. WRITTEN DOCUMENTATION
SHALL BE PROVIDED BY THE CONTRACTOR REGARDING
SUCH ITEMS.
7. STRUCTURAL, MECHANICAL, ELECTRICAL, LOW VOLTAGE
ARE SHOWN FOR REFERENCE ONLY. VERIFY EACH
ELEMENT WITH THE ASSOCIATED ENGINEER'S
DRAWINGS. COORDINATE CONFLICTS WITH THE
ARCHITECT.
8. REFER TO SPECIFICATIONS FOR EACH ITEM
REPRESENTED WITHIN THE DRAWING SET.
9. NOT ALL LIGHT FIXTURES ARE REPRESENTED ON THE
ARCHITECTURAL DRAWINGS. SEE ELECTRICAL
DRAWINGS FOR ADDITIONAL LIGHT FIXTURE TYPES AND
LOCATIONS. CONFIRM ANY DESCREPANCIES BETWEEN
DRAWINGS WITH THE ARCHITECT PRIOR TO
COMMENCEMENT OF WORK.
10. WHERE GYP. BD. CEILINGS ARE INDICATED TO BE LOWER
THAN ADJACENT ACT CEILINGS THE CONTRACTOR IS TO
PROVIDE A FINISHED VERTICAL GYP. BD. BULKHEAD
RETURN FROM THE LOWER FINISHED GYP. BD. CEILING
TO A MINIMIMUM OF 6" ABOVE THE ADJACENT ACT
CEILING UNLESS NOTED OTHERWISE. SEE FLOOR PLANS
AND LIFE SAFETY PLANS.
11. WHERE GYP. BD. CEILINGS ARE INDICATED TO BE LOWER
THAN ADJACENT GYP. DB. CEILINGS THE CONTRACTOR IS
TO PROVIDE A CONTINUOUS FINISHED VERTICAL GYP. BD.
BULKHEAD RETURN TO THE ADJACENT FINISHED GYP.
BD. CEILING.
CODED NOTES OF VARYING TYPES: SEE
SCHEDULES ON THIS SHEET
SYMBOL LEGEND
MATERIAL FINISH NOTE. SEE FINISH PLANS
AND SPECIFICATIONSP-X
1
CEIL
NOT
F
O
R
CON
S
T
R
U
C
TI
O
N
See Drawing
CERTIFICATION
626 North Illinois Street
Indianapolis, Indiana 46204
Phone: (317) 635-5030
Website: www.browningday.com
Checked By:
Scale:
Issue Date:
Drawn By:
Project No.:
Owner
6/16/2021 4:19:00 PM \\bdmd.local\UEM\UserShare\kthompson\Documents\FORUM_Carmel Reno_kthompson.rvtA1.01-C1
Reflected Ceiling Plan
21I010
Author
Checker
6/15/21
FORUM Credit Union
Branch Renovation
2259 E 116th Street,
Carmel, IN 46032
Construction Documents
11313 USA Parkway
Fishers, IN 46038
Phone: (317) 558-6000
Website: www.forumcu.com
FORUM Credit Union
9229 Delegates Row, Suite 150
Indianapolis, IN 46240
Phone: (317) 781-6200
Website: www.circledesigngroup.com
Circle Design Group
MEP Engineer
A1.01-C1 1/4" = 1'-0"
Reflected Ceiling Plan1 1st Floor RCP
REVISION SCHEDULE
Rev. # Revision Description Issue Date
07/06/21