HomeMy WebLinkAboutA011.4FLEX OFFICE 108 MECH 107 BREAK 109 RESTROOM 110 OFFICE 106 OFFICE 105 OFFICE 115 WORK 111 OFFICE 104 VAULT 112 TELLERS 113 VESTIBULE 100 LOBBY 101 ACT-1 11' - 0" ACT-1 8' - 6" ACT-1 11' - 0" ACT-1 9' - 0" ACT-1 10' - 0" ACT-1 10' - 0" GYP.BD. 10' - 0" ACT-1 10' - 0" GYP. BD 8' - 3" 8" ALIGN ALIGN ALIGN EXISTING SKYLIGHT TO REMAIN 4 A7.01 P-3 GENERAL CEILING PLAN NOTES 1. DO NOT SCALE DRAWINGS. 2. GYP. BD. CEILINGS AND THEIR ASSOCIATED BULKHEADS ARE TO BE PAINTED P-1 UNLESS NOTED OTHERWISE. 3. UNLIKE FLOOR PLAN DIMENSIONS, THOSE SHOWN ON THE REFLECTED CEILING PLAN ARE FINISHED DIMINSIONS UNLESS NOTED OTHERWISE. CEILING ELEVATIONS ARE TO THE FINISHED FACE OF THE CEILING FINISH MATERIAL. BULKHEAD DIMENSIONS ARE TO THE FINISHED FACE OF GYP. BD. DIMENSIONS TO LIGHT FIXTURES ARE TO THE CENTERPOINT OF THE FIXTURE, THE FINISHED EDGE OF FIXTURE, OR TO THE CENTERLINE OF ASSOCIATED CEILING GRID SYSTEM. 4. LETTER DESIGNATIONS WITHIN A DIMENSION STRING (SUCH AS "A", "B", "C" AND SO ON) INDICATE THAT THE DIMENSION IS TO BE FIELD DETERMINED AND IT IS TO BE EQUAL TO OTHER DIMENSIONS OF THE SAME LETTER THROUGHOUT THAT SPECIFIC DRAWING SHEET, BUT NOT TO THE SAME DESIGNATION ON OTHER DRAWING SHEETS. 5. USE OF "EQUAL" OR "EQ" WITHIN A DIMENSION STRING INDICATES A DIMENSION THAT IS TO BE EQUAL ONLY RELATIVE TO OTHER EQUAL CALLOUTS ON THE SAME DIMENSION STRING IN WHICH IT APPEARS. DIMENSIONS CALLED OUT AS EQUAL ON TWO DIFFERENT DIMENSION STRINGS ARE NOT NECESSARILY EQUAL TO EACH OTHER. 6. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE BUILDING ELEMENTS. CONTACT THE ARCHITECT WITH CONFLICTS, DISCREPANCIES, AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. WRITTEN DOCUMENTATION SHALL BE PROVIDED BY THE CONTRACTOR REGARDING SUCH ITEMS. 7. STRUCTURAL, MECHANICAL, ELECTRICAL, LOW VOLTAGE ARE SHOWN FOR REFERENCE ONLY. VERIFY EACH ELEMENT WITH THE ASSOCIATED ENGINEER'S DRAWINGS. COORDINATE CONFLICTS WITH THE ARCHITECT. 8. REFER TO SPECIFICATIONS FOR EACH ITEM REPRESENTED WITHIN THE DRAWING SET. 9. NOT ALL LIGHT FIXTURES ARE REPRESENTED ON THE ARCHITECTURAL DRAWINGS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL LIGHT FIXTURE TYPES AND LOCATIONS. CONFIRM ANY DESCREPANCIES BETWEEN DRAWINGS WITH THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. 10. WHERE GYP. BD. CEILINGS ARE INDICATED TO BE LOWER THAN ADJACENT ACT CEILINGS THE CONTRACTOR IS TO PROVIDE A FINISHED VERTICAL GYP. BD. BULKHEAD RETURN FROM THE LOWER FINISHED GYP. BD. CEILING TO A MINIMIMUM OF 6" ABOVE THE ADJACENT ACT CEILING UNLESS NOTED OTHERWISE. SEE FLOOR PLANS AND LIFE SAFETY PLANS. 11. WHERE GYP. BD. CEILINGS ARE INDICATED TO BE LOWER THAN ADJACENT GYP. DB. CEILINGS THE CONTRACTOR IS TO PROVIDE A CONTINUOUS FINISHED VERTICAL GYP. BD. BULKHEAD RETURN TO THE ADJACENT FINISHED GYP. BD. CEILING. CODED NOTES OF VARYING TYPES: SEE SCHEDULES ON THIS SHEET SYMBOL LEGEND MATERIAL FINISH NOTE. SEE FINISH PLANS AND SPECIFICATIONSP-X 1 CEIL NOT F O R CON S T R U C TI O N See Drawing CERTIFICATION 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.browningday.com Checked By: Scale: Issue Date: Drawn By: Project No.: Owner 6/16/2021 4:19:00 PM \\bdmd.local\UEM\UserShare\kthompson\Documents\FORUM_Carmel Reno_kthompson.rvtA1.01-C1 Reflected Ceiling Plan 21I010 Author Checker 6/15/21 FORUM Credit Union Branch Renovation 2259 E 116th Street, Carmel, IN 46032 Construction Documents 11313 USA Parkway Fishers, IN 46038 Phone: (317) 558-6000 Website: www.forumcu.com FORUM Credit Union 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 Phone: (317) 781-6200 Website: www.circledesigngroup.com Circle Design Group MEP Engineer A1.01-C1 1/4" = 1'-0" Reflected Ceiling Plan1 1st Floor RCP REVISION SCHEDULE Rev. # Revision Description Issue Date 07/06/21