Loading...
HomeMy WebLinkAboutA011.5A1.01-A2 A1.01-A2 6 4 7 A1.01-A2 5 OFFICE 115 CPT-1 P-2/P-3 B-1 OFFICE 105 CPT-1 P-2/P-3 B-1 OFFICE 106 CPT-1 P-2/P-3 B-1 FLEX OFFICE 108 CPT-1 P-2/P-3 B-1 MECH 107 BREAK 109 RFT-1 - B-1 RESTROOM 110 RFT-1 - B-1 WORK 111 CPT-1 P-2 B-1 VAULT 112 CPT-1 - B-1 OFFICE 104 CPT-1 P-2/P-3 B-1 VESTIBULE 100 CPT-2 P-2 B-1 TELLERS 113 CPT-1 P-2/P-3 B-1 LOBBY 101 CPT-1 P-2/P-3 B-1 A1.01-A28 PL-2 TELLER COUNTER TBD - CABINET FINISH P-3 GENERAL FINISH NOTES 1. REFER TO FINISH PLAN, ROOM FINISH SCHEDULE, INTERIOR ELEVATIONS, AND REFLECTED CEILING PLANS FOR FINISH INFORMATION. 2. MATERIAL INFORMATION IS GIVEN WHEREVER POSSIBLE ON THE INTERIOR SHEETS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BRING ANY DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT SO THAT THE CORRECT MATERIAL IS INSTALLED. 3. REFER TO THE SPECIFICATIONS FOR EACH MATERIAL SELECTION. 4. ALL MATERIALS ARE TO BE INSTALLED USING THE MANUFACTURER'S RECOMMENDED ADHESIVES. 5. GYP. BD. WALLS AND SOFFITS TO RECEIVE A LEVEL FOUR (4) FINISH UNLESS NOTED OTHERWISE. 6. WALLS ARE TO BE PAINTED P-2UNLESS NOTED OTHERWISE. 7. GYP. BD. BULKHEADS AND CEILINGS ARE TO BE PAINTED P-1 UNLESS NOTED OTHERWISE. 8. BULKHEADS, SOFFITS, AND FUR-DOWNS ARE TO BE FINISHED WITH THE SAME MATERIAL AND/OR COLOR ON ALL FACES AS SPECIFIED UNLESS NOTED OTHERWISE. 9. THERE SHALL NOT BE PAINT CONDITIONS THAT OCCUR CAUSING FINISH OR COLOR TO CHANGE ON AN OUTSIDE CORNER UNLESS NOTED OTHERWISE. IF THIS CONDITION OCCURS BRING THIS TO THE ARCHITECT'S ATTENTION IMMEDIATELY. 10. WALL GRILLES, CEILING DIFFUSERS, AND FIRE EXTINGUISHER CABINETS ARE TO BE FINISHED IN THE SAME MATERIAL AS THE ADJACENT WALL MATERIAL. 11. TRANSITIONS, REDUCER STRIPS, AND THRESHOLDS TO BE LOCATED AT CENTERLINE OF DOOR WHEN IN CLOSED POSITION. 12. ALIGN FLOORING TRANSITIONS WITH FINISH BASE EXCEPT AT DOORS UNLESS NOTED OTHERWISE. 13. FLOORING MATERIAL SHALL BE CENTERED UNDER THE DOOR IN THE CLOSED POSITION. TRANSITIONS, IF NEEDED, ARE ALSO TO BE CENTERED UNDER THE DOOR IN THE CLOSED POSITION. 14. CARPET SEAMS TO BE LOCATED AT CENTERLINE OF DOOR IN CLOSED POSITION. 15. CARPET TILE TO BE QUARTER TURNED UNLESS NOTED OTHERWISE. 16. FLOORING TO BE INSTALLED PERPENDICULAR TO ROOM WALLS UNLESS NOTED OTHERWISE. 17. RUBBER TRANSITIONS AND METAL TRANSITIONS TO OCCUR BETWEEN DIFFERENT MATERIALS AND ARE TO BE SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE OF PRODUCTS. 18. REQUIRED FLOORING UNDERLAYMENTS ARE TO BE PROVIDED AND INSTALLED BY THE FLOORING CONTRACTOR. SYMBOL LEGEND MATERIAL FINISH NOTE. SEE SHEET A5-SERIES OF DRAWINGS AND SPECIFICATIONSP-1 NOT F O R CON S T R U C TI O N See Drawing CERTIFICATION 626 North Illinois Street Indianapolis, Indiana 46204 Phone: (317) 635-5030 Website: www.browningday.com Checked By: Scale: Issue Date: Drawn By: Project No.: Owner 6/16/2021 4:19:03 PM \\bdmd.local\UEM\UserShare\kthompson\Documents\FORUM_Carmel Reno_kthompson.rvtA1.01-F 1st Floor, Finish Plan 21I010 Author Checker 6/15/21 FORUM Credit Union Branch Renovation 2259 E 116th Street, Carmel, IN 46032 Construction Documents 11313 USA Parkway Fishers, IN 46038 Phone: (317) 558-6000 Website: www.forumcu.com FORUM Credit Union 9229 Delegates Row, Suite 150 Indianapolis, IN 46240 Phone: (317) 781-6200 Website: www.circledesigngroup.com Circle Design Group MEP Engineer A1.01-F 1/4" = 1'-0" Floor Plan1 1st Floor Finish Plan REVISION SCHEDULE Rev. # Revision Description Issue Date 07/06/21