Loading...
HomeMy WebLinkAboutS001.0-S099.9 - HAM 39 - Slab FoundationTHICKENED EDGETHICKEN SLABUC REFRIG W.D. UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL UNEXCAVATED - 4" MIN. CONCRETE SLAB - GRAVEL FILL 60'-41 2" 24'-212" 84'-7" 712" 712"13'-212" 1'-912"16'-3"2'-8" 20'-812"33'-11"12'-0" 96'-7"5'-5"3'-0" 11'-1112"712"712"712"712" 6'-8" 7'-11" 6'-8" 21'-3" 8" 21'-5" 2'-8"7'-112" 2'-812"12'-6"34'-7116"2'-0"2'-1"1'-2" 6'-0" 1'-2" 712"7" 1'-11 2" 1'-11 2"712"3'-10" 4'-2" 10'-7" 6'-0" 52'-7" 712" 94'-7"6'-8"7" 3'-0" 7"3'-0"3'-0"6'-8"15'-0"10'-1114"912" 912"712"6"912" 912"91 2" 712" 2'-1112" 23'-7"712"NO ANCHORSTRAPSNO ANCHOR STRAPS 912" 20'-914" 534" 712"712"712"71 2" 712"712"712"912"THICKEN SLAB15'-134" 1'-4"4'-1134"20'-1014" 14'-934"1'-4" 6'-412"4'-0"412"MASTER SHOWER DROP 4" R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION R-10 RIGID INSULATION 30"x30"x12" Pad footingNO ANCHOR STRAPS12"x18" ANCHOR BOLTS 48" O.C. AIR SPACE BRICK VENEER FD5 FOUNDATION DETAIL7"534"12"X22" DEEP CONCRETE FOOTING @ 2500 PSI R-10 RIGIDINSULATION 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"X22" DEEP CONCRETE FOOTING @ 2500 PSI 12"x18" ANCHOR BOLTS 48" O.C. HOUSE SLABHOUSE SLAB GARAGE SLAB TOP OF MAIN LEVELSUB FLOOR 12" EDGE FD1 FOUNDATION DETAIL FD2 FOUNDATION DETAIL FD3 FOUNDATION DETAIL FD4 FOUNDATION DETAIL SCALE: 1/4"=1'-0" FOUNDATION PLAN 312"X312"X14" STL. COLUMN w/ 34"x12"x12" BASE PL. w/ (4) 34" HEADED ANCHOR ASTM A325 F1554 GRADE 36 FTG. SIZEN0. REINFORCEMENT INTERIOR COLUMN FOOTING SCHEDULE * HVAC CONTRACTOR TO PROVIDE CONTINUOUSLY OPERATED MECHANICAL VENTILATION AT A RATE OF 1.0 CFM FOR EACH 50 SQ.FT. OF CRAWL SPACE * VERIFY MECHANICAL ACCESSES THROUGH FOUNDATION WALL W/ CONTRACTOR & MECHANICAL CONTRACTOR A 54"X54"X12" (5)#4's E.W. B 48"X48"X12" (4)#4's E.W. C 42"X42"X12" (4)#4's E.W. D 36"X36"X12" (3)#4's E.W. E 30"X30"X12" (3)#4's E.W. BASED ON A SAFE ALLOWABLE BEARING PRESSURE OF 2000 psf ( TO BE FIELD VERIFIED ) SEE SCHEDULED FOR SIZE & REINFORCEMENT 3" CLEAR 3" CLEAR3" CLEAR1'-0"1. FOUNDATION DETAIL LEGEND INTERIOR COLUMN FOOTING DETAIL TYPICAL DETAIL INTERIOR COLUMN FOOTING INTERIOR COLUMN FOOTING TYPICAL DETAIL SEE SCHEDULED FOR SIZE & REINFORCEMENT 3" CLEAR3" CLEAR 4 PLY BLOCKING ANCHORED TO FOUNDATION w/1 2" X 8" ANCHOR BOLTS DRILLED & EPOXY 48" o.c.Make yourself at homeGrosmont Hamlet Lot 39 Radlick Townhouse3 REF.MICRO/ OVEN 42"x42"x12" Pad footing 05.27.2021 7'-6"5'-712" 3'-1113 16" 12'-712"6'-1118" 8'-6"42"x42"x12" Pad footing THICKEN SLABTHICKEN SLAB24"x24"x12" Pad footings 24"x24"x12" Pad Footing3'-618"3'-6"2'-8316"2'-6"12'-0" 3'-01116"4'-412"2'-0" 3'-0" 2'-0"15'-214"THICKEN SLABTHICKEN SLAB12'-9" 1'-4"12'-012"1'-4"7'-813 16" 07/12/21