HomeMy WebLinkAbout061421 PlansGRADING NOTES:
CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING UTILITIES.
PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING.
RR
R R
17'-8"18'-0"9'-0"2'-10"6'-8 1/2"6'-8"
LINE OF SLOPED CEILING
TRANSITION TO FLAT CEILING
LINE OF SLOPED CEILING
TRANSITION TO FLAT CEILING
GRILL STATION TO ENCLOSE
HOMEOWNER-PROVIDED GRILL
RAISED HEARTH WITH LIMESTONE CAP
VENTLESS FIREPLACE
4x4 POST WRAPPED WITH CEDAR -
COORDINATE WRAP WITH OPERABLE
SCREEN RECESSED TRACK
5'-6"6'-9"6'-9"
1'-9 1/4"5'-7 1/2"1'-9 1/4"1'-0"1'-0"8"8"17'-8"18'-0"7'-6" 7'-6" 1'-4" 1'-5"1'-4" 8'-3"8'-3" BRICK LEDGE
OUTLINE OF DECK ABOVE
DOUBLE 2x8 BEAM (P.T. PINE)
BEARING ON 4x4 POSTS
(TYPICAL OF 3)
18" DIA CONCRETE PIER
TO 36" BELOW GRADE
(TYPICAL OF 8)
CONCRETE BLOCK FOUNDATION
WALL ON CONRETE FOOTING 2x8 JOISTS (P.T. PINE)AT 16" ON CENTERFLUSH BEAM
LINE OF EXISTING
FOUNDATION WALL
VALLEY
EXISTING
RIDGESLOPE SLOPESLOPE 2:12
MANUFACTURER'S
MINIMUM SLOPE
LINE OF EXISTING
WALL BELOW
LINE OF POST AND BEAM
STRUCTURE BELOW
GUTTER
LINE OF
EXISTING SOFFIT C2021 SURROUNDINGSTHIS PLAN IS PROPERTY OFSURROUNDINGS.ANY UNAUTHORIZED USE ORREPRODUCTION OF THIS PLAN, INWHOLE OR IN PART ISPROHIBITED. SURROUNDINGSWILL USE ALL LEGAL MEANSAVAILABLE TO PURSUE THEUNAUTHORIZED USE OF THISPLAN OR ANY DESIGN ELEMENTSCONTAINED THEREIN.Meisner ResidenceCovered PorchGrandin Hall - Section 1 - Lot 1385361 Grandin Hall Circle South Carmel, Indiana 46033Date
06.14.21 Indiana Design Centert200 S. Rangeline Road Suite 120A Carmel, Indiana 46032Description
Foundation,
Floor, and
Roof Plan
Sheet Number
A-02
Foundation Plan
SCALE: 1/4" = 1'-0"
Floor Plan
SCALE: 1/4" = 1'-0"
Roof Plan
SCALE: 3/16" = 1'-0"
FOUNDATION NOTES:
ALL FOOTINGS TO REST ON CLEAN, FIRM UNDISTURBED SOIL. STEP
FOOTINGS A REQUIRED TO MAINTAIN REQUIRED DEPTH BELOW
FINISH GRADES.
CONCRETE STRENGTH,
3,000 PSI AT 28 DAYS FOR ALL SLABS. (FOUNDATION DESIGN BASED
ON 2,500 PSI).
3,000 PSI AT 28 DAYS FOR ALL OTHER CONDITION.
MAXIMUM SLUMP, 4"
07/12/21