Loading...
HomeMy WebLinkAboutA110 - 100_BID AND PERMIT (08-27-20)154SF153SFUP A. REFER TO A001-A002 FOR GENERAL NOTES, WALL TYPES, SYMBOLS AND TYPICAL CONSTRUCTION DETAILS. B. PROVIDE BULLNOSE CMU AT ALL EXPOSED CMU CORNERS. C. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT THE APPARATUS BAY AND ALL ROOMS DIRECTLY OFF OF IT. D. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT ALL WET WALLS IN KITCHENS, AND ALL WALLS AND CEILINGS IN BATHROOMS AND JANITOR CLOSETS. E. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD AT ALL CORRIDORS, STAIRCASES AND THE LOBBY. F. PLAN KEYNOTES APPLY TO SHEETS A101, A102 AND A110. GENERAL PLAN NOTES A 1 A.1 B B.1 C C.1 2 3 S1 S2 S3 02/ A601 01/ A601OFFICE 101 WF1 PT1 WB1 TELECOM 103 C1 PT1 WB1S1 S5S6C S6C S6C S6C S6C S6C7' - 8 3/4"9' - 3 5/8" 9' - 11 7/8"22' - 5 5/8" 27' - 6 5/8" 15' - 11 1/2" 5' - 10 7/8" 12' - 6 5/8" 6' - 0 3/4"4' - 0"15' - 9" 03/ A6011' - 5"04/ A601 4' - 0" 15' - 9" 4' - 0" 16' - 0" 4' - 0" 8' - 9 5/8"EX101AEX101B 101105104103 10243' - 0 7/8"12' - 3 3/4" BREAKROOM 102 WF1 PT1 WB1 JANITOR 104 C1 PT1 WB1 WC 105 C1 PT1 WB1 12' - 4 1/4"40' - 11 5/8"OFFICE 101 WF1 PT1 WB1 TELECOM 103 C1 PT1 WB1 BREAKROOM 102 WF1 PT1 WB1 JANITOR 104 C1 PT1 WB1 WC 105 C1 PT1 WB1 B.1 C C.1 9 10 11 12 A120 01 ELEC. 106 C1 SPRINKLER 107 C1 STAIR 108 C1 PT2 ELEV. 109 C1 CORRIDOR 110 EX1081082 HR M8C 2 HR M8C ES6 2 HR M8C 2 HR M8C M8A M8A M8A ES6 ES6 6' - 11 3/8" 11' - 5" 7' - 9 7/8" 19' - 10 1/2"9' - 4 3/8"8' - 1 7/8" 9' - 2 7/8" 12' - 11 1/8" EX106 B B.1 C C.1 D 32 28 29 30 31 A121 01 LOADING BAY 112 C1 PT2 STAIR 111 C1 PT2 112B EX112 2 HR M8C 2 HR M8C M8A ES6 M8A 112A 111DANDR ID GE DRE W WHITEHI T AR-19400087 ARC TEC STATE OF No. DNDI NAA AII R E G I STERE DNDI NA AI HI TARC TECDANDRID GE DRE W WHITEREVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT GSD DDW 08/17/2020 A110 ENLARGED PLANS 19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE PH: 763-425-9960 Gooderum & Associates Engineering 874 Cheltenham Way PH: 317-506-8151 Indianapolis, IN 46280 Albertville, MN 55301 Avon, IN 46123 Extra Space Storage 9000 Keystone Crossing, Ste. 660 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER MEP ENGINEER ENLARGED PLAN KEYNOTES 1 CLOUMN - REFER TO STRUCTURAL 2 CLEANING DRAIN 3 BREAK ROOM SINK 4 BREAK ROOM COUNTER 5 OVER COUNTER CABNETS SCALE: 1/4" = 1'-0"01 ENLARGED PLAN -OFFICE SCALE: 1/4" = 1'-0"02REFLECTED CEILING PLAN -OFFICE SCALE: 1/4" = 1'-0"03 ENLARGED PLAN -CIRCULATION SCALE: 1/4" = 1'-0"04ENLARGED PLAN -LOADING BAY #DESCRIPTION DATE 1 1 2 3 45 07/14/21