HomeMy WebLinkAboutA130 - 100_BID AND PERMIT (08-27-20)4' - 0"4' - 0"6" 1' - 0"5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
6" METAL STUD [05 41 00-A4]
STRUCTURAL STEEL COLUMN [05
12 00-A2]
COLUMN PLACEMENT VARIES,
REFERENCE
OVERALL DRAWINGS AND
STRUCTURAL.
4' - 0"3' - 11 1/4"8"4 1/2"5 1/2"8"
4 1/2" 5 1/2"1' - 0"6" 1' - 0" 6"
2X EXTERIOR GRADE
PRESERVATIVE-TREATED WOOD
BLOCKING (061053) [06 10 00-A3]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
STOREFRONT SYSTEM, CENTER
GLAZED [08 41 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]4' - 0"8"4 1/2"5 1/2" 1' - 0"6" STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
SCREW-ATTACHED MASONRY
VENEER ANCHOR, THERMAL (HB
THERMAL 2-SEAL WING NUT AND
2X-HOOK TIE OR EQUAL) [04 00
00-C8]
FLUID-APPLIED MEMBRANE AIR
BARRIER SHOWN DASHED [07 27
26-A1]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
2X EXTERIOR GRADE
PRESERVATIVE-TREATED WOOD
BLOCKING (061053) [06 10 00-A3]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4] STOREFRONT SYSTEM, CENTER
GLAZED [08 41 00-A2]
SEALANT AND BACKER ROD [07
92 00-A3]
A. REFER TO A001-A002 FOR GENERAL NOTES, WALL TYPES, SYMBOLS AND TYPICAL
CONSTRUCTION DETAILS.
B. PROVIDE BULLNOSE CMU AT ALL EXPOSED CMU CORNERS.
C. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT THE
APPARATUS BAY AND ALL ROOMS DIRECTLY OFF OF IT.
D. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM WALLBOARD AT ALL WET
WALLS IN KITCHENS, AND ALL WALLS AND CEILINGS IN BATHROOMS AND
JANITOR CLOSETS.
E. PROVIDE HIGH-IMPACT GYPSUM WALLBOARD AT ALL CORRIDORS, STAIRCASES
AND THE LOBBY.
F. PLAN KEYNOTES APPLY TO SHEETS A101, A102 AND A110.
GENERAL PLAN NOTES
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A130
PLAN DETAILS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
KIT OF PARTS
04 00 00-C8 SCREW-ATTACHED MASONRY VENEER ANCHOR, THERMAL (HB THERMAL
2-SEAL WING NUT AND 2X-HOOK TIE OR EQUAL)
04 20 00-A1 STANDARD BRICK - 3/8" JOINT
05 12 00-A2 STRUCTURAL STEEL COLUMN
05 41 00-A4 6" METAL STUD
06 10 00-A3 2X EXTERIOR GRADE PRESERVATIVE-TREATED WOOD BLOCKING (061053)
06 16 00-A2 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS
07 21 00-A2 INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD
INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS
07 27 26-A1 FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED
07 92 00-A3 SEALANT AND BACKER ROD
08 41 00-A2 STOREFRONT SYSTEM, CENTER GLAZED
09 29 00-A8 5/8" TYPE "X" GYPSUM WALLBOARD
SCALE: 1" = 1'-0"01 TYP. COLUMN DETAIL
SCALE: 1" = 1'-0" 03 TYP. CORNER DETAIL
SCALE: 1" = 1'-0" 02TYP. PILASTER DETAIL
#DESCRIPTION DATE
07/14/21