Loading...
HomeMy WebLinkAboutA303 - 100_BID AND PERMIT (08-27-20)FIRST FLOOR 100' - 0" THIRD FLOOR 124' - 0" SECOND FLOOR 113' - 4" 1 ROOF - AREA A 134' - 8" A310 01 A310 02 A310 03 A310 04 ES6 T/O OPENING 121' - 4"8' - 0" 2' - 8" 8' - 0" 5' - 4" 8' - 0" T/O FRAMING 140' - 8"2' - 8" 6' - 0"A311 04 ES6 STOREFRONT SYSTEM, CENTER GLAZED [08 41 00-A2] STOREFRONT SYSTEM, CENTER GLAZED [08 41 00-A2] STOREFRONT ENTRANCE DOOR [08 41 00-A3] REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION DETAILS. AIR SPACE [04 00 00-D7] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] AIR SPACE [04 00 00-D7] ? [04 21 13 -A1] STANDARD BRICK - 3/8" JOINT [04 20 00-A1] AIR SPACE [04 00 00-D7] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] 6" METAL STUD [05 41 00-A4] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] ? SPECIFIED ROOFING INSULATION [07 53 23-A3] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A3] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] E1 E1 INSULATION TYPE 5 - SPRAY APPLIED CELLULOSE INSULATION. FILL MISCELLANEOUS VOIDS [07 21 00-A5] SPRAY UNDERSIDE OF DECK IN ALL SOFFIT LOCATIONS - R30 MIN FIRST FLOOR 100' - 0" THIRD FLOOR 124' - 0" SECOND FLOOR 113' - 4" 11 A310 05 ?10' - 8"4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] NON-STRUCTURAL METAL FRAMING [09 22 16] NON-STRUCTURAL METAL FRAMING [09 22 16] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] NON-STRUCTURAL METAL FRAMING [09 22 16] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] E1 INSULATION TYPE 5 - SPRAY APPLIED CELLULOSE INSULATION. FILL MISCELLANEOUS VOIDS [07 21 00-A5] SPRAY UNDERSIDE OF DECK IN ALL SOFFIT LOCATIONS - R30 MIN FIRST FLOOR 100' - 0" SECOND FLOOR 113' - 4" 17 12' - 10"A311 02 REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION DETAILS. 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] AIR SPACE [04 00 00-D7] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] 6" METAL STUD [05 41 00-A4] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] E2 INSULATION TYPE 5 - SPRAY APPLIED CELLULOSE INSULATION. FILL MISCELLANEOUS VOIDS [07 21 00-A5] FIRST FLOOR 100' - 0" THIRD FLOOR 124' - 0" SECOND FLOOR 113' - 4" A ROOF - AREA A 134' - 8" A310 10 ES68' - 0"2' - 0" 6' - 0" 5' - 4" 10' - 8" A310 04 A311 03 A310 01 A310 03 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] AIR SPACE [04 00 00-D7] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] 6" METAL STUD [05 41 00-A4] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] AIR SPACE [04 00 00-D7] STANDARD BRICK - 3/8" JOINT [04 20 00-A1] 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] [04 21 13-A1] AIR SPACE [04 00 00-D7] STANDARD BRICK - 3/8" JOINT [04 20 00-A1] [04 21 13-A1] SPECIFIED ROOFING INSULATION [07 53 23-A3] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A3] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] E1 E1 DANDR ID GE DRE W WHITEHI T AR-19400087 ARC TEC STATE OF No. DND I NAA AII R EG I STERE DNDI NA AI HI TARC TECDANDRID GE DRE W WHITEREVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT GSD DDW 08/17/2020 A303 WALL SECTIONS 19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE PH: 763-425-9960 Gooderum & Associates Engineering 874 Cheltenham Way PH: 317-506-8151 Indianapolis, IN 46280 Albertville, MN 55301 Avon, IN 46123 Extra Space Storage 9000 Keystone Crossing, Ste. 660 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER MEP ENGINEER KIT OF PARTS 04 00 00-D7 AIR SPACE 04 20 00-A1 STANDARD BRICK - 3/8" JOINT 04 21 13-A1 04 22 00-D1 4" X 8" X 16" GROUND FACE CMU 05 13 00-A3 METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS 05 41 00-A4 6" METAL STUD 06 16 00-A2 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS 07 21 00-A2 INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS 07 21 00-A5 INSULATION TYPE 5 - SPRAY APPLIED CELLULOSE INSULATION. FILL MISCELLANEOUS VOIDS 07 53 23-A3 SPECIFIED ROOFING INSULATION 08 41 00-A2 STOREFRONT SYSTEM, CENTER GLAZED 08 41 00-A3 STOREFRONT ENTRANCE DOOR 09 29 00-A8 5/8" TYPE "X" GYPSUM WALLBOARD SCALE: 1/2" = 1'-0" 02WALL SECTION SCALE: 1/2" = 1'-0" 01 WALL SECTION SCALE: 1/2" = 1'-0"03 WALL SECTION SCALE: 1/2" = 1'-0"04WALL SECTION #DESCRIPTION DATE 07/14/21