HomeMy WebLinkAboutA305 - 100_BID AND PERMIT (08-27-20)FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
C.1D
ROOF - AREA A
134' - 8"
A310
07
A310
08
8' - 0" 5' - 4" 8' - 0" 2' - 8" 8' - 0" 2' - 8"A311
04 Sim
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
1/2" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A1]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]?
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
E1
E1
E1
A310
03
A310
04
INSULATION TYPE 5 - SPRAY
APPLIED CELLULOSE INSULATION.
FILL MISCELLANEOUS VOIDS [07 21
00-A5]
SPRAY UNDERSIDE OF DECK IN
ALL SOFFIT LOCATIONS - R30 MIN
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
A
ROOF - AREA A
134' - 8"2' - 0" 11' - 4" 10' - 8" 10' - 8"A311
06
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
FORMED METAL WALL PANELS -
PREFINISHED [07 41 14-A1]
AIR SPACE [04 00 00-D7]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
CIP CONCRETE SLAB ON GRADE -
REFER TO STRUCTURAL DRAWINGS
[03 30 00-A1]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
E3
E2
A310
11
FIRST FLOOR
100' - 0"
THIRD FLOOR
124' - 0"
SECOND FLOOR
113' - 4"
C.1 D
ROOF - AREA A
134' - 8"
A310
09
12' - 11 3/4" 11' - 0 1/4" 8' - 0"3 5/8"
A311
02 Sim
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
6" METAL STUD [05 41 00-A4]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
AIR SPACE [04 00 00-D7]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
5/8" TYPE "X" GYPSUM
WALLBOARD [09 29 00-A8]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
4" X 8" X 16" GROUND FACE CMU
[04 22 00-D1]
[04 21 13-A1]
STANDARD BRICK - 3/8" JOINT [04
20 00-A1]
AIR SPACE [04 00 00-D7]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A3]
SPECIFIED ROOFING INSULATION
[07 53 23-A3]
6" METAL STUD [05 41 00-A4]
5/8" GLASS-MAT GYPSUM
SHEATHING - TAPE ALL SEAMS [06
16 00-A2]
INSULATION TYPE 2 - STUD CAVITY
WALL: EXTRUDED-POLYSTYTRENE
BOARD INSULATION, 1-1/2" THICK,
R7.5 MINIMUM. TAPE ALL SEAMS
[07 21 00-A2]
METAL ROOF DECK - REFER TO
STRUCTURAL DRAWINGS [05 13
00-A1]
E2
E2
E2
A310
04
INSULATION TYPE 5 - SPRAY
APPLIED CELLULOSE INSULATION.
FILL MISCELLANEOUS VOIDS [07 21
00-A5]
SPRAY UNDERSIDE OF DECK IN
ALL SOFFIT LOCATIONS - R30 MIN
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DND
I NAA AII
R EG I STERE
DNDI NA AI
HI TARC TECDANDRID GE DRE
W
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
GSD
DDW
08/17/2020
A305
WALL SECTIONS
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
SCALE: 1/2" = 1'-0" 01 WALL SECTION
SCALE: 1/2" = 1'-0" 02WALL SECTION
SCALE: 1/2" = 1'-0" 03 WALL SECTION
#DESCRIPTION DATE
07/14/21