HomeMy WebLinkAboutA305 - 100_BID AND PERMIT (08-27-20)FIRST FLOOR 100' - 0" THIRD FLOOR 124' - 0" SECOND FLOOR 113' - 4" C.1D ROOF - AREA A 134' - 8" A310 07 A310 08 8' - 0" 5' - 4" 8' - 0" 2' - 8" 8' - 0" 2' - 8"A311 04 Sim 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] 1/2" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A1] [04 21 13-A1] STANDARD BRICK - 3/8" JOINT [04 20 00-A1] AIR SPACE [04 00 00-D7] STANDARD BRICK - 3/8" JOINT [04 20 00-A1] 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] 6" METAL STUD [05 41 00-A4] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] [04 21 13-A1] STANDARD BRICK - 3/8" JOINT [04 20 00-A1] AIR SPACE [04 00 00-D7]? 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A3] SPECIFIED ROOFING INSULATION [07 53 23-A3] E1 E1 E1 A310 03 A310 04 INSULATION TYPE 5 - SPRAY APPLIED CELLULOSE INSULATION. FILL MISCELLANEOUS VOIDS [07 21 00-A5] SPRAY UNDERSIDE OF DECK IN ALL SOFFIT LOCATIONS - R30 MIN FIRST FLOOR 100' - 0" THIRD FLOOR 124' - 0" SECOND FLOOR 113' - 4" A ROOF - AREA A 134' - 8"2' - 0" 11' - 4" 10' - 8" 10' - 8"A311 06 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] AIR SPACE [04 00 00-D7] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] FORMED METAL WALL PANELS - PREFINISHED [07 41 14-A1] AIR SPACE [04 00 00-D7] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] 6" METAL STUD [05 41 00-A4] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] SPECIFIED ROOFING INSULATION [07 53 23-A3] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A3] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] CIP CONCRETE SLAB ON GRADE - REFER TO STRUCTURAL DRAWINGS [03 30 00-A1] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] E3 E2 A310 11 FIRST FLOOR 100' - 0" THIRD FLOOR 124' - 0" SECOND FLOOR 113' - 4" C.1 D ROOF - AREA A 134' - 8" A310 09 12' - 11 3/4" 11' - 0 1/4" 8' - 0"3 5/8" A311 02 Sim 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] AIR SPACE [04 00 00-D7] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] 6" METAL STUD [05 41 00-A4] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] AIR SPACE [04 00 00-D7] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] 4" X 8" X 16" GROUND FACE CMU [04 22 00-D1] [04 21 13-A1] STANDARD BRICK - 3/8" JOINT [04 20 00-A1] AIR SPACE [04 00 00-D7] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A3] SPECIFIED ROOFING INSULATION [07 53 23-A3] 6" METAL STUD [05 41 00-A4] 5/8" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A2] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] METAL ROOF DECK - REFER TO STRUCTURAL DRAWINGS [05 13 00-A1] E2 E2 E2 A310 04 INSULATION TYPE 5 - SPRAY APPLIED CELLULOSE INSULATION. FILL MISCELLANEOUS VOIDS [07 21 00-A5] SPRAY UNDERSIDE OF DECK IN ALL SOFFIT LOCATIONS - R30 MIN DANDR ID GE DRE W WHITEHI T AR-19400087 ARC TEC STATE OF No. DND I NAA AII R EG I STERE DNDI NA AI HI TARC TECDANDRID GE DRE W WHITEREVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT GSD DDW 08/17/2020 A305 WALL SECTIONS 19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE PH: 763-425-9960 Gooderum & Associates Engineering 874 Cheltenham Way PH: 317-506-8151 Indianapolis, IN 46280 Albertville, MN 55301 Avon, IN 46123 Extra Space Storage 9000 Keystone Crossing, Ste. 660 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER MEP ENGINEER SCALE: 1/2" = 1'-0" 01 WALL SECTION SCALE: 1/2" = 1'-0" 02WALL SECTION SCALE: 1/2" = 1'-0" 03 WALL SECTION #DESCRIPTION DATE 07/14/21