HomeMy WebLinkAboutA401 - 100_BID AND PERMIT (08-27-20)A.REFER TO CEILING PLAN FOR ALL CEILING HEIGHTS.
B.ALL GRIDS ARE CENTERED IN ROOMS EACH DIRECTION UNLESS NOTED
OTHERWISE.
C.LOCATE CEILING GRIDS WITHIN ROOMS SUCH THAT BORDERS CONTAIN NOT LESS
THAN 1/2 TILE WIDTH, UNLESS OTHERWISE INDICATED.
D.CENTER PENETRATIONS IN ACOUSTICAL CEILING SYSTEMS WITHIN INDIVIDUAL
CEILING PANELS, SUCH AS SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES, ETC.,
UNLESS OTHERWISE INDICATED.
E.PAINT ALL EXPOSED GYPSUM WALLBOARD SURFACES UNLESS NOTED
OTHERWISE. REFER TO FINISH PLAN FOR COLORS.
F. ALL EXPOSED DUCTWORK, PIPING, CONDUITS ETC. SHALL BE PAINTED. COLOR
TO MATCH CEILING OR EXPOSED STRUCTURE UNLESS OTHERWISE NOTED.
G.PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD CEILINGS AT 20'
MAXIMUM. VERIFY LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION.
H.COORDINATE REFLECTED CEILING PLAN WITH MECHANICAL, PLUMBING,
ELECTRICAL, AND LIFE SAFETY PLANS. PROVIDE COORDINATION DRAWINGS FOR
REVIEW PRIOR TO CEILING INSTALLATION.
I. LIGHT FIXTURES, SPRINKLER HEADS, HVAC SUPPLY AND RETURN GRILLES ARE
SHOWN FOR LOCATION ONLY. REFER TO MEP DRAWINGS FOR ADDITIONAL
INFORMATION
J. PROVIDE ACOUSTICAL CEILING HOLD-DOWN CLIPS IN VESTIBULES. IN ROOMS
WITH EXTERIOR ENTRANCE DOORS PROVIDE HOLD-DOWN CLIPS FOR 10' IN ALL
DIRECTION OF DOORWAY.
K.CEILING ACCESS PANELS INDICATED ARE NOT INTENDED TO LIMIT NUMBER OF
PANELS REQUIRED. PANEL QUANTITY SHALL BE SUFFICIENT TO PROVIDE REQUIRED
ACCESS WHETHER OR NOT INDICATED ON THE DRAWINGS. VERIFY LOCATIONS
WITH ARCHITECT PRIOR TO INSTALLATION.
GENERAL CEILING PLAN NOTES
CEILING LEGEND
2x2 LAY-IN CEILING GRID
4x4 LAY-IN CEILING GRID
GYPSUM BOARD CEILING OR
GYPSUM BOARD BULKHEAD
EXPOSED STRUCTURE
CEILING TAG
CEILING TYPE
CEILING HEIGHT
X
X
B
8' - 0"
B
11' - 4"
B
12' - 10"
1
1
1
2
2
2
DANDR ID GE DRE
W
WHITEHI T
AR-19400087
ARC TEC
STATE OF
No.
DNDI NAA AII
R E G I STERE
DNDI NA AI
HI TARC TECDANDRID GE DREW
WHITEREVISIONS:
DRAWN BY
DATE ISSUED
CHECKED BY
Scope Drawings
These drawings indicate the general scope of the project in terms of
architectural design concept, the dimensions of the building, the major
architectural elements and the type of structural, mechanical and
electrical systems. The drawings do not necessarily indicate or describe
all work required for full performance and completion of the requirements
of the contract. On the basis of the general scope indicated or
described, the trade contractors shall furnish all items required for the
proper execution and completion of work.
PROJECT NUMBER:
618 East Market Street
Indianapolis, Indiana 46202
phone 317/264.8162
a x i s a r c h . c o m
CLIENT
MA
GSD
8.27.2020
A401
SOFFIT REFLECTED CEILING
PLAN
19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers
10505 N. College Avenue
Brad Schoeff - Sr. Project Manager
PH: 317-846-6611
Innovative Structural Solutions, P.A.
5279 Kyler Avenue, NE
PH: 763-425-9960
Gooderum & Associates Engineering
874 Cheltenham Way
PH: 317-506-8151
Indianapolis, IN 46280
Albertville, MN 55301
Avon, IN 46123
Extra Space Storage
9000 Keystone Crossing, Ste. 660
Jim Adams
Indianapolis, IN 46240
PH: 317-663-8648
CIVIL ENGINEER
STRUCTURAL ENGINEER
MEP ENGINEER
CEILING TYPES
TYPE DESCRIPTION
GYPSUM WALLBOARD BULKHEAD ON 3-5/8" INTERIOR METAL FRAMING.
RETURN FACE OF DRYWALL TO CEILING OR STRUCTURE ABOVE.
REFER TO FINISH PLANS FOR PAINTING.
A ACOUSTICAL PANEL TYPE A IN GRID TYPE A. 24" X 24" ACOUSTICAL
CEILING TO BE ARMSTRONG OPTIMA 3355 SQUARE TEGULAR
INSTALLED IN 9/16" SILHOUETTE XL BOLT SLOT 1/8"
REVEAL SUSPENSION GRID.
B EIFS SOFFIT ON 5/8" GLASS-MAT GYPSUM WALLBOARD AND 6" METAL STUDS,
TYPICAL.
G GYPSUM WALLBOARD BULKHEAD ON 3-5/8" INTERIOR METAL FRAMING.
RETURN FACE OF DRYWALL TO CEILING OR STRUCTURE ABOVE.
REFER TO FINISH PLANS FOR PAINTING.
REFLECTED CEILING KEYNOTES
1 FIRE PROTECTION CONTRACTOR TO PROVIDE ADEQUETE SPRINKLER HEAD
COVERAGE UNDER SOFFIT AREAS. PROVIDE EXTERIOR DRY SPRINKLER HEADS
LOW-VOLTAGE ACUATORS.
SCALE: 1/8" = 1'-0" 01 SOFFIT REFLECTED CEILING PLAN -AREA A
SCALE: 1/8" = 1'-0"02FIRST FLOOR REFLECTED CEILING PLAN
#DESCRIPTION DATE
07/14/21