Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A502 - 100_BID AND PERMIT (08-27-20)
SEALANT JOINT AT FRAME PERIMETER TYP. CFMF HEADER. DESIGN PER OPENING WIDTH MESH WEEP/VENT [04 00 00-D4] COPPER -LAMINATED THROUGH-WALL FLASHING WITH STAINLESS STEEL DRIP EDGE. HEM EXPOSED EDGE [04 00 00-D2] CAVITY DRAINAGE MATERIAL [04 00 00-D5] FLASHING TERMINATION BAR [04 00 00-D3] STEEL LINTEL. REFER STRUCT. LINTEL SCHEDULE 5/8" 6" 1/2" 3 7/8" 3 5/8" CONTINUE FLUID-APPLIED AIR BARRIER INTO FRAMED OPENING REFER TO ELEVATIONS FOR MASONRY HEADER CONDITION - LIMESTONE, SOLDIER OR BAND COURSE STOREFRONT SYSTEM, THERMALLY BROKEN, FRONT GLAZED [08 41 00-A1] 7 1/8" 4 1/2" 3" 2x4 2x4 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] INSULATION TYPE 4 - KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN. [07 21 00-A4] 6" METAL STUD [05 41 00-A4] 1/2" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A1] FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] [04 21 13-A1] AIR SPACE [04 00 00-D7] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] SEALANT JOINT AT FRAME PERIMETER TYP. MESH WEEP/VENT [04 00 00-D4] COPPER-LAMINATED THROUGH-WALL FLASHING WITH STAINLESS STEEL DRIP EDGE. HEM EXPOSED EDGE [04 00 00-D2] CAVITY DRAINAGE MATERIAL [04 00 00-D5] FLASHING TERMINATION BAR [04 00 00-D3] STEEL LINTEL. REFER STRUCT. LINTEL SCHEDULE CONTINUE FLUID-APPLIED AIR BARRIER INTO FRAMED OPENING REFER TO ELEVATIONS FOR MASONRY HEADER CONDITION - SOLDIER OR BAND COURSE. QUEEN BRICK - 3/8" JOINT [04 20 00-A3] [04 20 00-E1] 1 1/2" 2x4 2x4 7 5/8" 4 3/4" 3 5/8" STOREFRONT SYSTEM, THERMALLY BROKEN, FRONT GLAZED [08 41 00-A1] FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] AIR SPACE [04 00 00-D7] [04 21 13-A1] 8 1/2" 3 7/8" 5/8" STRUCTRUAL STEEL BEAM. REFER TO STRUCTRUAL DRAWINGS [04 20 00-E1] [06 2023-01] [04 21 13-A1] STOREFRONT SYSTEM, THERMALLY BROKEN, FRONT GLAZED [08 41 00-A1] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] INSULATION TYPE 4 - KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN. [07 21 00-A4] GLAZING - REFER TO ELEVATION FOR TYPE. SOLID SURFACE WINDOW SILL - REFER TO FINISH PLAN (123662) [12 36 62-A1]5/8"6" 8" CONTINUE SELF ADHERING SHEET AIR BARRIER INTO FRAMED OPENING 2x4 2x4 7 1/8"4 1/2" 3" 1/2" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A1] AIR SPACE [04 00 00-D7] SCREW-ATTACHED MASONRY VENEER ANCHOR, THERMAL (HB THERMAL 2-SEAL WING NUT AND 2X-HOOK TIE OR EQUAL) [04 00 00-C8] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2]3" 4 1/2" 8 1/2"CONTINUE SELF ADHERING SHEET AIR BARRIER INTO FRAMED OPENING QUEEN BRICK - 3/8" JOINT [04 20 00-A3] SOLID SURFACE WINDOW SILL - REFER TO FINISH PLAN (123662) [12 36 62-A1] STOREFRONT SYSTEM, THERMALLY BROKEN, FRONT GLAZED [08 41 00-A1] GLAZING - REFER TO ELEVATION FOR TYPE.1' - 4"1 1/2"2x4 2x4 SOLID SOLDIER WITH 3/8" JOINT [04 20 00-B4] FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] AIR SPACE [04 00 00-D7] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] [06 2023-01] [04 00 00-C11] SEALANT JOINT AT FRAME PERIMETER TYP. FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] CONTINUE SELF ADHERING SHEET AIR BARRIER INTO FRAMED OPENING 1/2" [04 21 13 -A1] SOLID SURFACE WINDOW SILL - REFER TO FINISH PLAN (123662) [12 36 62-A1]2"3 1/2" 2x42x4 INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] STOREFRONT SYSTEM, THERMALLY BROKEN, FRONT GLAZED [08 41 00-A1] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] INSULATION TYPE 4 - KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN. [07 21 00-A4] 6" METAL STUD [05 41 00-A4] 5/8" 6" 1/2" 3 7/8" 3 5/8" 7 1/8" 4 1/2" 3" AIR SPACE [04 00 00 -D7] 1/2" GLASS-MAT GYPSUM SHEATHING - TAPE ALL SEAMS [06 16 00-A1] [04 21 13 -B2] GLAZING - REFER TO ELEVATION FOR TYPE SILL FLASHING SELF ADHERING SHEET AIR BARRIER SHOWN DASHED [07 27 13-A1] WRAP AROUND BLOCKING SEALANT JOINT AT FRAME PERIMETER TYP. FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] CONTINUE SELF ADHERING SHEET AIR BARRIER INTO FRAMED OPENING 1/2"3 1/2"[04 21 13 -A1] 7 1/8" 4 1/2" 3" SOLID SURFACE WINDOW SILL - REFER TO FINISH PLAN (123662) [12 36 62-A1] STOREFRONT SYSTEM, THERMALLY BROKEN, FRONT GLAZED [08 41 00-A1] 2x4 2x4 7 5/8" 4 3/4" 3 5/8" SOLID BRICK SILL [04 20 00-B2] QUEEN BRICK - 3/8" JOINT [04 20 00-A3] INSULATION TYPE 2 - STUD CAVITY WALL: EXTRUDED-POLYSTYTRENE BOARD INSULATION, 1-1/2" THICK, R7.5 MINIMUM. TAPE ALL SEAMS [07 21 00-A2] [04 21 13-B2] SILL FLASHING AIR SPACE [04 00 00-D7] SELF ADHERING SHEET AIR BARRIER SHOWN DASHED [07 27 13-A1] WRAP AROUND BLOCKING PRE FINISHED ALUM. DOOR ALUM. THRESHOLD SET IN BED OF SEALANT EXPANSION JOINT FLOOR FINISH - SEE FLOOR FINISH CONCRETE SLAB / FOUNDATION - REFER STRUCTURAL DWG'S EXTERIOR EXTERIOR PAVING - REFER LANDSCAPE / CIVIL DWG'S REFER TO ELEVATIONS FOR GLAZING TYPE INTERIOR [04 21 13-A1] 5/8" TYPE "X" GYPSUM WALLBOARD [09 29 00-A8] 6" METAL STUD [05 41 00-A4] INSULATION TYPE 4 - KRAFT FACED FIBERGLASS BATT INSULATION, R19 MIN. [07 21 00-A4] FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] 5/8"6" 8" CONTINUE FLUID-APPLIED AIR BARRIER INTO FRAMED OPENING 2x4 2x4 6"3" SEALANT AT PERIMETER TYP. HOLLOW METAL DOOR FRAME - REFER SCHEDULE HM JAMB ANCHOR HOLLOW METAL FRAME - REFER SCHEDULE SEALANT JOINT AT FRAME PERIMETER TYP. METAL STUD HEADER. SIZE PER OPENING WIDTH 5 5/8" 6" 3" MESH WEEP/VENT [04 00 00-D4]COPPER-LAMINATED THROUGH-WALL FLASHING WITH STAINLESS STEEL DRIP EDGE. HEM EXPOSED EDGE [04 00 00-D2] CAVITY DRAINAGE MATERIAL [04 00 00-D5] FLASHING TERMINATION BAR [04 00 00-D3] FLUID-APPLIED MEMBRANE AIR BARRIER SHOWN DASHED [07 27 26-A1] STEEL LINTEL. REFER STRUCT. LINTEL SCHEDULE 5/8" 6" 1/2" 7 1/2"DANDR ID GE DRE W WHITEHI T AR-19400087 ARC TEC STATE OF No. DND I NAA AII R EG I STERE DNDI NA AI HI TARC TECDANDRID GE DRE W WHITEREVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT GSD DDW 08/17/2020 A502 EXTERIOR DOOR AND STOREFRONT DETAILS 19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE PH: 763-425-9960 Gooderum & Associates Engineering 874 Cheltenham Way PH: 317-506-8151 Indianapolis, IN 46280 Albertville, MN 55301 Avon, IN 46123 Extra Space Storage 9000 Keystone Crossing, Ste. 660 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER MEP ENGINEER SCALE: 3" = 1'-0"03STOREFRONT EXTERIOR -HEAD DETAIL BRICK SCALE: 3" = 1'-0"06STOREFRONT EXTERIOR -HEAD DETAIL CMU SCALE: 3" = 1'-0"02STOREFRONT EXTERIOR -JAMB DETAIL BRICK SCALE: 3" = 1'-0" 05 STOREFRONT EXTERIOR -JAMB DETAIL CMU SCALE: 3" = 1'-0" 01STOREFRONT EXTERIOR -SILL DETAIL BRICK SCALE: 3" = 1'-0"04STOREFRONT EXTERIOR -SILL DETAIL CMU #DESCRIPTION DATE SCALE: 3" = 1'-0"07STOREFRONT EXTERIOR -SILL DETAIL SCALE: 3" = 1'-0"08HM DOOR JAMB DETAIL BRICK SCALE: 3" = 1'-0" 09HM HEAD DEATIL BRICK 07/14/21