Loading...
HomeMy WebLinkAboutA601 - 100_BID AND PERMIT (08-27-20)MILLWORK LEGEND XX" XX" XX" EXTRA SHELF 300MCABINET WIDTH CABINET HEIGHT FEATURE DESCRIPTION CABINET DEPTH CABINET TYPE CABINET TAG A. MILLWORK IS BASED ON AWI ARCHITECTURAL WOODWORK STANDARDS 2009 EDITION. B. DESIGN DRAWINGS ARE BASED ON CDS (CABINET DESIGN SERIES) NUMBERS. REFER TO CABINET TAG BELOW FOR DESCRIPTION. C. REFER TO TYPICAL CASEWORK DETAILS ON THIS SHEET FOR PROJECT SPECIFIC CONSTRUCTION REQUIREMENTS. THESE MAY BE DEVIATIONS FROM AWI STANDARD. D. REFER TO PROJECT MANUAL/SPECIFICATIONS FOR ADDITIONAL INFORMATION ON PLASTIC LAMINATE AND STAINLESS STEEL CABINETS. E. IF DRAWINGS OR SPECIFICATIONS ARE IN CONFLICT, PROVIDE MORE STRICT OR MORE EXPENSIVE OPTION. A. REFER TO A201 FOR EXTERIOR MATERIAL SCHEDULE. B. REFER TO A505 FOR WINDOW/STOREFRONT ELEVATIONS. C. PAINT ALL EXPOSED MISC. STEEL LINTELS, PLATES, ANGLES, ETC. PX UNLESS NOTED OTHERWISE. D. ALL BASE TO BE B1 UNLESS NOTED OTHERWISE. E. COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS AND CEILINGS. F. ALL RESTROOM ACCESSORIES WILL BE NEW. G. PROVIDE FILLERS AS REQUIRED. FILLERS ARE TO MACH MILLWORK ADJACENT. H. ALL WALLS TO BE PAINTED P1 UNLESS NOTED OTHERWISE. GENERAL INTERIOR ELEVATION NOTES 4 2 T3 T2 4 1 2 3 T4 T5 T2 T3 T1 T2 4 1 T5 T4 T1 1' - 8" 1' - 8" 3' - 4"1' - 8" 1' - 8" 2" 15' - 11 1/2"2' - 10" 2' - 10" 2" 3' - 4" 3' - 4" 3' - 4" 5 6 7 8 9 6 8 10 5' - 9 1/2" 3' - 4"5' - 9 1/2"9' - 0"10' - 2"4" 1' - 8" 2" 8"9"DANDR ID GE DRE W WHITEHI T AR-19400087 ARC TEC STATE OF No. DND I NAA AII R EG I STERE DNDI NA AI HI TARC TECDANDRID GE DRE W WHITEREVISIONS: DRAWN BY DATE ISSUED CHECKED BY Scope Drawings These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of work. PROJECT NUMBER: 618 East Market Street Indianapolis, Indiana 46202 phone 317/264.8162 a x i s a r c h . c o m CLIENT GSD DDW 08/17/2020 A601 INTERIOR ELEVATIONS 19045CARMELExtra Space Storage155 CARMEL DRIVE, CARMEL, INWeihe Engineers 10505 N. College Avenue Brad Schoeff - Sr. Project Manager PH: 317-846-6611 Innovative Structural Solutions, P.A. 5279 Kyler Avenue, NE PH: 763-425-9960 Gooderum & Associates Engineering 874 Cheltenham Way PH: 317-506-8151 Indianapolis, IN 46280 Albertville, MN 55301 Avon, IN 46123 Extra Space Storage 9000 Keystone Crossing, Ste. 660 Jim Adams Indianapolis, IN 46240 PH: 317-663-8648 CIVIL ENGINEER STRUCTURAL ENGINEER MEP ENGINEER INTERIOR ELEVATION KEYNOTES 1 WALL HUNG SINK - ADA COMPLIANT. REFER TO PLUMBING DWGS. 2 FLOOR MOUNTED PLUMBING FIXTURE. REFER TO PLUMBING DWGS. 3 STAINLESS STEEL TERMINATION CAP. 4 GYPSUM BOARD - PAINT. 5 PLASTIC LAMINATE TOE KICK - PL1 6 PLASTIC LAMINATE FILLER STRIP - TYPICAL AT EACH SIDE OF UPPER AND LOWER CABNETS. 7 PLASTIC LAMINATE BASE CABINETS - PL1. 8 CABINETS HARDWARE 9 PLASTIC LAMINATE COUNTERTOP AND BACKSPLASH - PL2 10 SINK - ADA COMPLIANT. REFER TO PLUMBING DWGS. 1 2 3 4 5 6 7 SCALE: ELEVATION 1/2" = 1'-0" 01 RESTROOM EAST WALL SCALE: ELEVATION 1/2" = 1'-0" 02RESTROOM NORTH WALL SCALE: ELEVATION 1/2" = 1'-0"03 RESTROOM WEST WALL SCALE: ELEVATION 1/2" = 1'-0"04BREAKROOM NORTH WALL #DESCRIPTION DATE 07/14/21