HomeMy WebLinkAboutC603 - 100_BID AND PERMIT (08-27-20)E
OHU OHU OHUOHU OHU OHU OHU OHU
OHU
OH U
OHU
OHU
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
G
W
W W
G
G
W
WEST C
A
R
M
E
L
D
R
I
V
E
GGG
PROPOSED BUILDING
20,121SF± PER FLOOR
F.F.E. = 829.85CSTM STM STM STM STM STMSTM STM STM STM STM STM STMESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS W W W W W W W W W W W W W WW W W WEE E E E E E E E EDRY POND
C603OVERFLOW ROUTING PLANW190582-C601 OVERFLOW ROUTING PLANREVISIONS AND ISSUES Part of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR: 147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JSDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATE BY08.17.2020SSRDATE:RLWKnow what'sbelow.
before you dig.Call
R
EXTRA SPACE STORAGE - CARMELISSUED FOR CITY REVIEW 01.13.2020 BJSISSUED FOR TAC REVISIONS 05.12.2020 BJS
W
S
N
E E N GI N E E R S317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil Engi neeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with conf idence. SMSTEVEN SCOTT RUCKER, PE No. 11300279
08/17/2020TAC REVISIONS 03.30.2020 BJSISSUED FOR TAC REVISIONS 06.08.2020ISSUED FOR TAC REVISIONS 07.16.2020 BJSWALL GRADING CLARIFICATION 07.23.2020 BJS100% BID AND PERMIT PLANS 08.17.2020 BJS
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
PARKING LOT LIGHT (1 HEAD)
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E. DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
TOC TOP OF CASTING
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
DRAINAGE PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
FLOW LINE
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E(A) E(A)
E E E
C C C
C(A) C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A) FO(A)
UNDERGROUND FIBER OPTICFO FO
EMERGENCY FLOOD ROUTE
SANITARY SEWER LATERALSAN SAN
ROOF DRAINSTM STM
SUB SURFACE DRAIN
FLOW DIRECTION AND SLOPE
D D LIMITS OF DISTURBANCE
100 YEAR CLOGGED INLET PONDING LIMITS
GENERAL NOTES
THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD
AREA AS ESTABLISHED BY THE FEDERAL
EMERGENCY MANAGEMENT AGENCY - NATIONAL
FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY
SCALE ON FLOOD INSURANCE RATE MAP
#18057C0209 G, DATED NOVEMBER 19, 2014.
BENCHMARK DATA
BM G 54 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5 FT. OUT OF THE GROUND ALONG
U.S. 31, 1.4 MILES NORTH OF I-465, 0.4 MILES SOUTH OF 116TH STREET, 100 FT. WEST OF
CENTERLINE OF SOUTH BOUND LANE OF U.S. 31, AND 2 FT. EAST OF R/W FENCE.
BM G 55 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5 FT. OUT OF THE GROUND ALONG
U.S. 31, 2.6 MILES NORTH OF I-465, 0.7 MILES SOUTH OF 131ST STREET, 83 FT. WEST OF
CENTERLINE OF SOUTH BOUND LANE OF U.S. 31.
BM Y 42 -
CGS DISK IN CONCRETE SLAB ON THE EAST SIDE OF THE MONON TRAIL 218 FT. SOUTH OF 111TH
STREET.
M.F.P.G. = 828.90
M.L.A.G. = 828.85
07/14/21